| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC H NO 283 PHASE 3 KRISHNAPURAM MISROD HOSHANGABAD ROAD BHOPAL MP PIN 462046 | BHOPAL | BHOPAL | MADHYA PRADESH | 462046 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹22.0 L+₹1.5 L (7.58%)Rejected-Finance 00 00 BAIRIYA NEAR KALI MAA MANDIR BALLIA UTTAR PRADESH 277502 | BALLIA | UTTAR PRADESH | 277502 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹22.0 L+₹1.6 L (7.61%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹22.3 L+₹1.9 L (9.11%)Rejected-Finance 44 CHUNABHATTI CHATTRAPATI SHIVAJI COLONY KOLAR ROAD CHUNABHATTI VILLAGE TOWN CITY BHOPAL BHOPAL MADHYA PRADESH 462016 INDIA | BHOPAL | MADHYA PRADESH | 462016 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹23.3 L+₹2.9 L (14.2%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | Aditya Sales Corporation L4 | M/s logitech solution L1 | Neha Enterprises L2 | MODI CORPORATION L3 | PRAGATI ELECTRICALS AND ELECTRONICS L5 | City buildcom builders & devlopers L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | |||||||||
| 1.10 | S&F of automatic star delta starter in sheet metal enclosure, wall mounted suitable for centrifugal pump/ submercible pump/ monoblock pump of capacity upto 17.5 HP, 3 phase, 415 volt, 50 Hz with suitable relay range of 9-15 Amps, MN-16 contactor etc including single phase preventer and taking out old starter single phase preventer fittings complete all as specified and directed. | 2 | Each | 13,500 ₹27,000 Lowest | 24,915 ₹49,830 | 23,800 ₹47,600 | 18,900 ₹37,800 | 22,000 ₹44,000 | 35,000 ₹70,000 |
| 2.00 | S&F in replacement of MCCB, 4 pole, 63 Amp, 25 KA breaking capacity, adjustable overload setting: 0.8 - 1.0 x In, adjustable short-circuit settings: 6 - 10 x In, Ics = 100% of Icu including spreader links and making connections with suitable size copper lugs and fittings complete all as specified and directed. | 2 | Each | 5,250 ₹10,500 | 2,752 ₹5,504 | 2,800 ₹5,600 | 2,400 ₹4,800 Lowest | 2,500 ₹5,000 | 6,000 ₹12,000 |
| 3.00 | S&F in replacement of MCCB, 4 pole, 100 Amp, 25 KA breaking capacity, adjustable overload setting: 0.8 - 1.0 x In, adjustable short-circuit settings: 6 - 10 x In, Ics = 100% of Icu including spreader links and making connections with suitable size copper lugs and fittings complete all as specified and directed. | 1 | Each | 5,500 ₹5,500 Lowest | 8,376 ₹8,376 | 6,000 ₹6,000 | 6,000 ₹6,000 | 8,500 ₹8,500 | 9,500 ₹9,500 |
| 4.00 | S&F in replacement power contactor, type ML-4 AC3 rating, 3 pole, 415 Volts, 50 Hz, 3 Phase with auxilary contacts 2 NO + 2 NC as per existing complete all as specified and directed. | 3 | Each | 18,500 ₹55,500 | 2,737 ₹8,211 | 1,900 ₹5,700 Lowest | 4,900 ₹14,700 | 2,500 ₹7,500 | 2,700 ₹8,100 |
| 5.00 | S&F in replacement power contactor, type ML-6 AC3 rating, 3 pole, 415 Volts, 50 Hz, 3 Phase with auxilary contacts 2 NO + 2 NC as per existing complete all as specified and directed. | 3 | Each | 28,750 ₹86,250 | 2,734 ₹8,202 | 2,000 ₹6,000 Lowest | 8,900 ₹26,700 | 8,000 ₹24,000 | 3,000 ₹9,000 |
| 6.00 | S&F in replacement power contactor, type ML-2 AC3 rating, 3 pole, 415 Volts, 50 Hz, 3 Phase with auxilary contacts 2 NO + 2 NC as per existing complete all as specified and directed. | 2 | Each | 7,250 ₹14,500 | 1,348 ₹2,696 Lowest | 1,500 ₹3,000 | 2,450 ₹4,900 | 2,500 ₹5,000 | 1,500 ₹3,000 |
| 7.00 | S&F in replacement electronic timer for Star Delta Starter of time range 3-30 sec, 415 Volts, 50 Hz complete all as specified and directed. | 4 | Each | 1,200 ₹4,800 | 1,488 ₹5,952 | 1,400 ₹5,600 | 1,150 ₹4,600 Lowest | 1,200 ₹4,800 | 1,200 ₹4,800 |
| 8.00 | S&F in replacement thermal over load relay for Star Delta Starter of range 9-15 Amp, MN-2, 415 Volts, 50 Hz including built-in single phasing protection, manual and auto reset mode & conforms IS/IEC 60947-4-1 & IEC 60947-4-1 complete all as specified and directed. | 5 | Each | 1,360 ₹6,800 | 1,504 ₹7,520 | 1,300 ₹6,500 | 1,250 ₹6,250 | 1,200 ₹6,000 Lowest | 2,100 ₹10,500 |
| 9.00 | S&F in replacement thermal over load relay for Star Delta Starter of range 66-110 Amp, MN-5, 415 Volts, 50 Hz complete including built-in single phasing protection, manual and auto reset mode & conforms IS/IEC 60947-4-1 & IEC 60947-4-1 complete all as specified and directed. | 2 | Each | 4,000 ₹8,000 | 5,160 ₹10,320 | 3,500 ₹7,000 | 3,450 ₹6,900 Lowest | 4,500 ₹9,000 | 6,000 ₹12,000 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Jul 2025, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT OF VERTICAL TURBINE PUMPS CENTRIFUGAL PUMPS SUBMERSIBLE PUMPS DG SETS INCLUDING COMPREHENSIVE MAINT OF WATER SUPPLY SCADA SYSTEM AND CONNECTED WORKS AT BAIRAGARH UNDER GE BHOPAL
2025_MES_696247_2
8352/E8
Open Tender
Civil Works - Water Works
Item Rate
335 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹50,000
Yes
26 Sept 2025
14 Jun 2025
10 Jul 2025
14 Jun 2025
8 Jul 2025
26 Jun 2025
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
S&F of automatic star delta starter in sheet metal enclosure, wall mounted suitable for centrifugal pump/ submercible pump/ monoblock pump of capacity upto 17.5 HP, 3 phase, 415 volt, 50 Hz with suitable relay range of 9-15 Amps, MN-16 contactor etc including single phase preventer and taking out old starter single phase preventer fittings complete all as specified and directed.
S&F in replacement of MCCB, 4 pole, 63 Amp, 25 KA breaking capacity, adjustable overload setting: 0.8 - 1.0 x In, adjustable short-circuit settings: 6 - 10 x In, Ics = 100% of Icu including spreader links and making connections with suitable size copper lugs and fittings complete all as specified and directed.
S&F in replacement of MCCB, 4 pole, 100 Amp, 25 KA breaking capacity, adjustable overload setting: 0.8 - 1.0 x In, adjustable short-circuit settings: 6 - 10 x In, Ics = 100% of Icu including spreader links and making connections with suitable size copper lugs and fittings complete all as specified and directed.
S&F in replacement power contactor, type ML-4 AC3 rating, 3 pole, 415 Volts, 50 Hz, 3 Phase with auxilary contacts 2 NO + 2 NC as per existing complete all as specified and directed.
S&F in replacement power contactor, type ML-6 AC3 rating, 3 pole, 415 Volts, 50 Hz, 3 Phase with auxilary contacts 2 NO + 2 NC as per existing complete all as specified and directed.
S&F in replacement power contactor, type ML-2 AC3 rating, 3 pole, 415 Volts, 50 Hz, 3 Phase with auxilary contacts 2 NO + 2 NC as per existing complete all as specified and directed.
S&F in replacement electronic timer for Star Delta Starter of time range 3-30 sec, 415 Volts, 50 Hz complete all as specified and directed.
S&F in replacement thermal over load relay for Star Delta Starter of range 9-15 Amp, MN-2, 415 Volts, 50 Hz including built-in single phasing protection, manual and auto reset mode & conforms IS/IEC 60947-4-1 & IEC 60947-4-1 complete all as specified and directed.
S&F in replacement thermal over load relay for Star Delta Starter of range 66-110 Amp, MN-5, 415 Volts, 50 Hz complete including built-in single phasing protection, manual and auto reset mode & conforms IS/IEC 60947-4-1 & IEC 60947-4-1 complete all as specified and directed.
S&F in replacement automatic star delta starter in sheet metal enclosure, wall mounted suitable for centrifugal pump of capacity upto 60 HP, 3 phase, 415 volt, 50 hz, relay range 28-42 Amp, ML-3 contactor, including single phase preventer fittings complete all as specified and directed.
S&F in replacement submersible flat copper cable XLPE insulated and PVC sheathed industrial 3 core flat submersible cable with bare bunched copper conductor of size 6 sqmm x 3 core, 415/220 Volts, 50 Hz and making necessary connections complete all as specified and directed.
S&F in replacement submersible flat copper cable XLPE insulated and PVC sheathed industrial 3 core flat submersible cable with bare bunched copper conductor of size 4 sqmm x 3 core, 415/220 Volts, 50 Hz and making necessary connections complete all as specified and directed.
S&F in replacement DOL starter upto 10 HP of relay range 9 to 15 Amps in sheet metal enclosure, wall mounted type suitable for 3 phase, 415 volts, 50 Hz, MN-16 complete all as specified and directed.
S&F in replacement automatic star delta starter in sheet metal enclosure, wall mounted type suitable for centrifugal pump/ submercible pump/ monoblock pump/ vertical turbine pump of capacity 75 HP, 3 phase, 415 volt, 50 hz, suitable relay range in 45 to 75 Amp, ML-4 contactor, complete all as specified and directed.
Supply only in replacement chlorine testing kit of range 0.1 PPM to 5 PPM including chlorine testing liquid complete all as specified and directed.
S&F in repairs round copper lugs of 25 Sqmm of cross section area of cable complete all as specified and directed.
S&F in repairs round copper lugs of 35 Sqmm of cross section area of cable complete all as specified and directed.
S&F in repairs round copper lugs of 50 Sqmm of cross section area of cable complete all as specified and directed.
S&F in repairs round copper lugs of 16 Sqmm of cross section area of cable complete all as specified and directed.
Supply, fabrication and fixing mild steel channel/ pipe fitting/ barrel piece/ lateral pipe as per site requirement including nuts, bolts, washers or necessary welding work etc. and fibre board gasket and making joint leak proof including dismantling old structure complete all as specified and directed.
M&L for running welding work, thickness of metal to be welded exc 9 mm but n exc 20 mm including cutting, jointing etc complete all as specified and directed.
S&F in replacement thermal overload relay with setting range 14-23 Amp, MN-2, 415 Vols, 50 Hz for 3 Phase including built-in single phasing protection, manual and auto reset mode & conforms IS/IEC 60947-4-1 & IEC 60947-4-1 complete all as specified and directed.
S&F in replacement electronic timer for Star Delta Starter of time range 12-120 sec, 220 Volt, 50 Hz complete all as specified and directed.
S&F in replacement single phase preventor suitable for equipments of caacity upto 75 HP, 440 volt, 50 Hz complete all as specified and directed.
M&L for taking out submersible pumping set complete with column pipe of any capacity and any type from existing bore well carefully without damaging the pump set including connecting parts and lowering the same after carrying necessary repair work including providing suitable size of nuts & bolts with washer and suitable packing for column pipes and making connection of submersible cable complete all as specified and directed. Note: (1) Chain pully block and clamps etc shall be provided by the contractor. (2) Spares parts required will be measured and paid seperately under respective item.
Disconnecting/ Dismentling of submersible/ centrigual/ Monoblock/ Pressure Pump/ Non Clog motor Pump/ VT Pump/ open well pump set assembly from its foundation at various locations at Bairagarh pump house and transporting to civil workshop for repair includes dismentling and opening of pump assy for checking out defects, taking out shaft from pump and carrying out lathe work for checking and making straightness, taking out of old worn out brass impeller and M&L for filling material on worn out part, grinding, poilshing and carrying out complete lathe work, refixing on shaft and check for its smooth functioning and balancing complete and transporting back after repairing, fixing to its existing position and making all connections complete all as specified and directed of following capacities:- Note: Spare parts required will be measured and paid under relevent item.
240 HP motor
60 HP to 75 HP motor
10 HP to 25 HP motor
5 HP to 7.5 HP motor
1 HP to 3 HP motor
Taking out unserviceable spares and burnt copper binding wire complete and M&L for rewinding of submersible motor/ open well motor of 1 to 30 HP capacity with best quality insulated copper winding wire including sleeves and replacement of worn out parts including grinding & polishing of rotor sleeves includin refixing, testing & transport charges complete all as specified and directed. Note: Spare parts will be measured and paid seperately under relevent item except binding wire.
S&F of the following parts of the submersible /open well pump and motor of capacity between 5 HP to 10 HP of existing make complete all as specified and directed:-
Bowl bush
Impeller
Neck ring
Shaft sleeve
Pump shaft
Coupling
Coupling key
Impeller key
Stud with nuts
Thrust bearing
Lower housing bush
Upper housing bush
Rotor shaft sleave
Drain plug
Water seal
CI Bowl
Bearing Suitable for pump set
Rotor Shaft
S&F of the following parts of the submersible /open well pump and motor for capacity between 11 HP to 20 HP of existing make complete all as specified and directed:-
Bowl bush
Impeller
Neck ring
Shaft sleeve
Pump shaft
Coupling
Coupling key
Impeller key
Stud with nuts
Thrust bearing
Lower housing bush
Upper housing bush
Rotor shaft sleave
Drain plug
Water seal
CI Bowl
Rotor Shaft
Bearing Suitable for Existing Pump
Taking out unserviceable spares and burnt copper binding wire complete and M&L for rewinding of centrifugal/ monoblock/ pressure pump/ Non clog motor pump set of 1 to 240 HP capacity with best quality insulated copper winding wire including sleeves and replacement of worn out parts including grinding & polishing of rotor sleeves includin refixing, testing & transport charges complete all as specified and directed. Note: Spare parts will be measured and paid seperately under relevent item except binding wire.
S&F of the following parts of the centrigual Pump and motor for capacity 240 HP of existing make complete all as specified and directed:-
Bowl bush
Impeller
Neck ring
Shaft sleeve
Pump shaft
Coupling
Coupling key
Impeller key
Stud with nuts
Thrust bearing
Lower housing bush
Upper housing bush
Rotor shaft sleave
Drain plug
Water seal
CI Bowl
Rotor Shaft
Bearing Suitable for Existing Pump
S&F of the following parts of the centrigual /Monoblock / Pressure Pump/Non clog pumpset and motor for capacity between 50 HP to 65 HP of existing make complete all as specified and directed.
Bowl bush
Impeller
Neck ring
Shaft sleeve
Pump shaft
Coupling
Coupling key
Impeller key
Stud with nuts
Thrust bearing
Lower housing bush
Upper housing bush
Rotor shaft sleave
Drain plug
Water seal
CI Bowl
Rotor Shaft
Bearing Suitable for Existing Pump
S&F of the following parts of the centrigual /Monoblock / Pressure Pump/Non clog pumpset and motor for capacity between 10 HP to 25 HP of existing make complete all as specified and directed:-
Bowl bush
Impeller
Neck ring
Shaft sleeve
Pump shaft
Coupling
Coupling key
Impeller key
Stud with nuts
Thrust bearing
Lower housing bush
Upper housing bush
Rotor shaft sleave
Drain plug
Water seal
CI Bowl
Rotor Shaft
Bearing Suitable for Existing Pump
S&F of the following parts of the centrigual /Monoblock / Pressure Pump /vaccum pump and motor for capacity between 1 HP to 10 HP of existing Make complete all as specified and directed:-
Bowl bush
Impeller
Neck ring
Shaft sleeve
Pump shaft
Coupling
Coupling key
Impeller key
Stud with nuts
Thrust bearing
Lower housing bush
Upper housing bush
Rotor shaft sleave
Drain plug
Water seal
CI Bowl
Rotor Shaft
Taking out unserviceable spares and burnt copper binding wire complete and M&L for rewinding of vertical turbine motor of 75 HP capacity with best quality insulated copper winding wire including sleeves and replacement of worn out parts including grinding & polishing of rotor sleeves includin refixing, testing & transport charges complete all as specified and directed. Note: Spare parts will be measured and paid seperately under relevent item except binding wire.
S&F of the following parts of the VT Pump and motor for capacity between 75 HP of original company complete all as specified and directed:-
Bearing
Impuller
Ishpenter Bush
Neck Ring (04 Nos)
Shaft Turning (04 Nos)
Bush (04 Nos)
Rotor Seal
Bowl bush
Neck ring
Shaft sleeve
Pump shaft
Coupling
Coupling key
Impeller key
Stud with nuts
Thrust bearing
Lower housing bush
Upper housing bush
Rotor shaft sleave
Drain plug
Water seal
CI Bowl
Rotor Shaft
S&F for SWR rope of size 10 mm outer dia for tie/anchoring with submersible pump set complete all as specified and directed.
S&F in replacement MCCB, 4 pole, 250 Amps, 25 KA, breaking capacity, adjustable overload setting: 0.8 - 1.0 x In, adjustable short-circuit settings: 6 - 10 x In, Ics = 100% of Icu including spreader links and making connections with suitable size copper lugs & connected fittngs complete all as specified and directed.
S&F in replacement MCCB, 4 pole, 200 Amps, 25 KA, breaking capacity, adjustable overload setting: 0.8 - 1.0 x In, adjustable short-circuit settings: 6 - 10 x In, Ics = 100% of Icu including spreader links and making connections with suitable size copper lugs & connected fittngs complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth: for foundation etc or for manholes, laying of pipe lines, cables, pipes etc in any type of soil and getting out complete all as specified and directed.
Returning filling in, including spreading, leveling watering & well rammng in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for brick work with sub class B bricks, straight or curved on plain, exc 6 m mean radious built in cement mortar 1:4 complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in copping/support and similar work including necessary form work etc complete all as specified and directed.
M&L for rendering 15mm thick on fair face of brick work in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Periodical maintenance of exisitng Air pressure Machine of pressure rating of 7.0 kg/sq cm for backwash of filter bed at main filter pump house such as checking of compressure & all sericeable parts,cleaning,greasing of all moving parts including minor repairs of 7.5HP motor complete all as specfied and directed. Model-ET5-7.5 Motor Cap-7.5 HP Rated Pressure-7.0 kg/cm2
S&F in replacement LED type indicating lamp for indication of RYB-01 Set complete all as specified and directed.
S&F in replacement aluminium bus bar rating 200 Amps, 50 KA, 25/6 mm including making holes suitable for panel with tape insulation of suitable colour in phase RYB & neutral in black colour complete all as specified and directed.
S&F of PVC body first aid box kit of size 11'' x 9'' x 3'' with locking arrangement with key complete all as specfied and directed.
Supply, laying and testing cables XLPE insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes:-
50 Sqmm 3.5 core
70 Sqmm 3.5 core
Supply and laying local clean dry sand as filling in trenches around under ground cable and similar work complete all as specified and directed.
M&L for provinding of new type-I flat LV cable cover of size 250 x 150 x 40 mm as per IS -5820 for protection of under ground cable complete all as specfied and directed.
Comprehensive maintenance including monitoring, management and operation of SCADA based water supply pumping and distribution system for smooth working of system with and including carrying out repairs, maintenance and servicing of all PLC panels and all connected circuit and accessories as required for water supply system as described below at Bairagarh under GE Bhopal complete all as specified and directed. The scope of work shall be comprising of the following activities:- (a) Servicing and maintenace/repairs and replacement of defective components/ spare parts of PLC based control panels including all accessories modem, antenna etc. installed at various pump houses, OHT and master control station, mimic panel. (b) Repair/maintenance by disconnecting, cleaning, greasing for wear and tear components complete with servicing, refixing, lathing, installing and commissioning of all motorised valves, pressure switch, ultrasonic level sensor. (c) Any changes to the programmable logic controller (PLC) e.g. changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of items covered under this AMC) (d) Any changes to the SCADA software, e.g. cchanges in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of items covered under this AMC) (e) SCADA reports related to all the systems to be mailed to AGE/JE on every week. (f) To attend break down maintenance immediately and replacement of unservicable spare parts as required at site as directed by AGE/JE.
Item No 53 contd.... Notes:- (i) All components/spare parts replaced shall be measured and paid seperatly as supply only item mentioned in schedule and fixing charges shall deemed to be include in the unit rate quoted in item. (ii) All the calls related to unservicability/ break down of the system should be attend with in the day immediately, failing which a penalty of Rs 500.00 will be imposed for each day untill the system gets repaired. (iii) The quoted rate shall also inclusive of all the charges for the communications, i.e. 01 No. BSNL broad band connection with static IP at Pump House and GPRS enabled data cards used in all PLC based panel related to this scope of work. (iv) The quoted rate shall also include cleaning and maintaining the surrounding of the installation building in such manner like model installation (v) Minor repair for leakage by providing gland packing, replacement of flange gasket and maintenance of control panel/ pumping set including replacement of rewireable fuses, piece of wire of any guage or size, tightening loose connections etc. of pump house shall deemed to be included in unit rate quoted by the contractor.
Item No 53 contd.. General notes for execution of work:- (a) Servicing of motorised valve, PLC base control panels, mimic panels shall be done by authorized representative of the manufacturer or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field only. The technician shall submit a letter from the Manufacturer or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field as proof of his being a authorised representative of the Manufacturer or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field. The technician shall also submit a signed report on original letter head of the manufacturer or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field that servicing has been carried out by him. (b) Any changes to the Programmable Logic Controller (PLC), e.g. changes in ladder logic of programme, changes in operational timing, etc. (limited to the scope of work covered under this AMC) shall be carried out by well experience representative of the manufacturer of PLC based panels or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field only. The programmer shall submit a letter from the manufacturer or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field as proof of his being an authorized representative of the Manufacturer or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field. The programmer shall also submit a signed report on original letter head of the Manufacturer or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field that servicing has been carried out by him. (c) Any changes to the SCADA software, e.g. changes in report format, changes in operational screens, creation of soft keys etc. (limited to the scope of work covered under this AMC) shall be carried out by authorized manufacturer of PLC based panels or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field only. The technician shall submit a letter from the manufacturer or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field as proof of his being a authorized representative of the manufacturer or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field. The technician shall also submit a signed report on original letterhead of the manufacturer or any other agency dealing with the installation and maintenance of SCADA system having vast experience in the relevant field that servicing has been carried out by him.
Taking out unserviceable burnt copper binding wire of electric motor of Actuator complete and M&L for rewinding the same with best quality insulated copper winding wire including sleeves complete all as specified and directed of following sizes:-
50/80 mm dia
100 mm dia
150 mm dia
200/250 mm dia
Supply of Single Phase Preventor with Under and Overvoltage Protection for SCADA system complete all as specified and directed. Make : Minilec / L&T / GIC
Supply only Relay Card Single C/O, 24 V DC for SCADA system complete all as specified and directed. Make : Omron / UL / TTPL / Phoenix Contact
Supply only Relay with Base 2 C/O, 240 V AC for SCADA system complete all as specified and directed. Make : Omron / Salzer / IDEC / Phoenix Contact
Supply only Relay with Base 2 C/O, 24 V DC for SCADA system complete all as specified and directed. Make : Omron / Salzer / IDEC / Phoenix Contact
Supply only 22 mm LED Indicator Colour-Red/ Yellow/ Green for SCADA system complete all as specified and directed. Make : ESBEE / Schneider / Siemens / ABB
Supply only 10 mm LED Indicator Colour-Red/ Yellow/ Green for SCADA system complete all as specified and directed. Make : ESBEE / Schneider / Siemens / ABB
Supply only push button with LED Indicator - 24 V DC Colour-Red/ Yellow/ Green for SCADA system complete all as specified and directed. Make : ESBEE / Schneider / Siemens / ABB
Supply only SMPS input, 5 Amp, 230 V AC & output 24 V DC for SCADA system complete all as specified and directed. Make : Omron / Schneider / TTPL / Phoenix Contact
S&F in replacement of float type point level sensor for over head tank, magnetic type, ring type magnet, reed switch and 2 core teflon connecting cable complete all as specified and directed. Make: Universal Switch Gear Control or equivalent as approved by GE.
S&F in replacement of ultrasonic level transmitter at sump and overhead tank for measurement of level with following specifications;- Range : 0-8 meters Accuracy : 0.5 % minimum Supply Voltage : 24 V DC Output : 4-20 mA , 0-10 V DC Make: Pepperl+ Fuchs / Nivelco / Siemens/ Banner
S&F in replacement of solenoid valve, 12 mm dia, 230 V, AC, brass or stainless steel body, direct acting / diaphragm type, pilot operated solenoid valve for air release with manual bypass arrangement along with all necessary installation accessories like gate valve, barrel piece, double nipple, elbows/bends etc complete all as specified and directed with following specification:- (a) Size:- 12mm (b) Designed line pressure:- 0.5 to 10 bar (c) Body Material:- Stainless Steel / Brass (d) Coil Power:- 6 W Make : Samson SED / SD Tork / Rotex/ Avcon
S&F in replacement of power contactor 9 Amps, 3 poles complete all as specified and directed. Make: L&T / Schneider / Havells
S&F in replacement of limit switch for Actuator of size 50/ 80/ 100/ 150/ 200 mm size valves complete all as specified and directed.
Supply, installation, testing and commissioning of Cat6 - 4 pair unshielded twisted pair UTP lan armoured cable for Sensors complete all as specified and directed. Make : D Link/ Havells / Polycab/ KEI
Supply only 1 Sqmm, single core PVC sheathed PVC insulated copper cable complete all as specified and directed.
Supply only 1.5 sqmm 4 core PVC sheathed PVC insulated copper armoured cable complete all as specified and directed.
Supply only 1.5 sqmm 6 core PVC sheathed PVC insulated copper armoured cable complete all as specified and directed.
Maintanance and servicing of Diesel Generator sets of 320 KVA capacity installed at MFPH of Make: Cummins by carrying out routine 'B' check of the engine for smooth functioning complete all as per manufacturer's instructions and as directed.
Maintanance and servicing of Diesel Generator sets of 50 KVA capacity installed at GE office of Make: Kirloskar by carrying out routine 'B' check of the engine for smooth functioning complete all as per manufacturer's instructions and as directed.
Maintanance and servicing of Diesel Generator sets of 30 KVA capacity installed at MH pump house of Make: Kirloskar by carrying out routine 'B' check of the engine for smooth functioning complete all as per manufacturer's instructions and as directed.
Maintanance and servicing of Diesel Generator sets of 20 KVA capacity installed at 21 CGSR of Make: Mahindra by carrying out routine 'B' check of the engine for smooth functioning complete all as per manufacturer's instructions and as directed.
Note for item No. 73 to 76:- (i) Control switches , MCCB's, contactors, multi display meters, engine control unit are exlusive for servicing/ maintenance from above item of work. (ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set alongwith connected alternator and panel board as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG Set for a period of 30 days from the date of service and shall also attend all the maintenance / breakdown repairs as and when required in that period except in case of major repairs. (iii) Spare parts, engine oil and radiator coolant oil required during the maintenance period shall be measured and paid seperatly at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item. (iv) List of checks to be carriedout under 'B' check is attached to the Particular specifications.
Supply only fuel filter pre and secondary including rubber gasket for DG sets of capacity 320 KVA complete all as specified and directed.
Supply only fuel filter pre and secondary including rubber gasket for DG sets of capacity 20 to 50 KVA complete all as specified and directed.
Supply only lube oil filter including rubber gasket for DG sets of capacity 320 KVA complete all as specified and directed.
Supply only lube oil filter including rubber gasket for DG sets of capacity 20 to 50 KVA complete all as specified and directed.
Supply only air filter element including rubber gasket for DG sets of capacity 320 KVA complete all as specified and directed.
Supply only air filter element including rubber gasket for DG sets of capacity 20 to 50 KVA complete all as specified and directed.
Supply only fan belt of existing size for DG sets of capacity 320 KVA complete all as specified and directed.
Supply only fan belt of existing size for DG sets of capacity 20 to 50 KVA complete all as specified and directed.
Supply only radiator hose with clip of existing size for DG sets of capacity 320 KVA complete all as specified and directed.
Supply only radiator hose with clip of existing size for DG sets of capacity 20 to 50 KVA complete all as specified and directed.
Supply only rubber coupling of existing size for DG sets of capacity 320 KVA complete all as specified and directed.
Supply only rubber coupling of existing size for DG sets of capacity 20 to 50 KVA complete all as specified and directed.
Supply only the following items for incorporation in the DG sets as directed:-
Engine oil 20 W 40
Distilled water
Coolant
Benzo bolt with washer
Jubilee clamp for fuel pipe
Fuel Flexible pipe with brass or GM adaptor
Oil Flexible pipe with brass or GM adaptor
Flexible reinforced pressure pipe 3/8" dia.
Flexible reinforced pressure pipe 1/2" dia.
Flexible reinforced pressure pipe 1" dia.
S&F in replacement of expansion bellows, stainless steel for exhaust manifold for DG Set of capacity 320 KVA complete all as specified and directed.
S&F in replacement of expansion bellows, stainless steel for exhaust manifold for DG Set of capacity 20 to 50 KVA complete all as specified and directed.
Dismantling the fuel pump from the engine of DG set of capacity 320 KVA, transporting to the service center for complete servicing and overhauling of the pump with and including M&L for replacement of service kit, element, delivery valve, plunger, copper washer etc. as required and re-calibration, refixing and testing complete all as specified and directed.
Dismantling the fuel pump from the engine of DG set of capacity 20 to 50 KVA, transporting to the service center for complete servicing and overhauling of the pump with and including M&L for replacement of service kit, element, delivery valve, plunger, copper washer etc. as required and re-calibration, refixing and testing complete all as specified and directed.
S&F in replacement new water pump of existing size suitable for DG Set of capacity 320 KVA and testing complete all as specified and directed.
S&F in replacement new water pump of existing size suitable for DG Set of capacity 20 to 50 KVA and testing complete all as specified and directed.
S&F in replacement new fuel AC pump of existing size suitable for DG Set of capacity 320 KVA and testing complete all as specified and directed.
S&F in replacement new fuel AC pump of existing size suitable for DG Set of capacity 20 to 50 KVA and testing complete all as specified and directed.
Draining out the diesel tank and cleaning/ washing out the sludge and re-filling with retrieved diesel in the tank for DG set of capacity 320 KVA complete all as specified and directed.
Draining out the diesel tank and cleaning/ washing out the sludge and re-filling with retrieved diesel in the tank for DG set of capacity 20 to 50 KVA complete all as specified and directed.
Taking down radiator of DG set of capacity 320 KVA including servicing, cleaning of with suitable reagent, washing thoroughly, arresting leakage by welding / brazing and refixing the same in its original position complete all as specified and directed. Note: Necessary coolant and distilled water required will be measured and paid seperately under respective item of Schedule.
Taking down radiator of DG set of capacity 20 to 50 KVA including servicing, cleaning of with suitable reagent, washing thoroughly, arresting leakage by welding / brazing and refixing the same in its original position complete all as specified and directed. Note: Necessary coolant and distilled water required will be measured and paid seperately under respective item of Schedule.
S&F in replacement of fuel injector pipe of existing size suitable for DG Set of capacity 320 KVA and testing complete all as specified and directed.
S&F in replacement of fuel injector pipe of existing size suitable for DG Set of capacity 20 to 50 KVA and testing complete all as specified and directed.
S&F in replacement of following parts / items for DG set of any capacity as directed:-
Oil pressure gauge.
Battery terminal socket GM including soldering.
Battery terminal leads complete with brass connector
Radiator Cap
Fuel Tank Cap with Lock
Door lock of any type and size complete Set.
Door gasket of any type and size complete set.
Carbon brushes for charging alternator
PT Pump repair Kit
AVR suitable for 320 KVA Alternators
AVR suitable for 25 to 40 KVA Alternators
S&F in replacement of the following parts / items for DG set control panel of any capacity as directed:-
AC Ammeter digital type
AC Volt meter digital type 0 to 500 volt.
Frequency meter
DC Volt meter 0 to 24 V
lgnition switch with key for on, off and run.
DIN rail for fixing MCB
Indicator lamp for panel board as per existing size.
No Volt coil suitable for 3 phase power contactor 160-200 Amps ratings
Dash board pilot lamp.
Control cable 2.5 sqmm copper Multistranded.
Control cable 4 sqmm copper Multistranded.
Toggle switch 15 Amps
AMF relay 12 Volt DC
Battery charging alternator 12 Volt
Temperature gauge with sensor
RPM Meter
Door hinges
Oil pressure sensor
AMF panel relay
Battery charger AC to DC
Electro timer with NO/NC
ON/OFF delay timer, 240 V
Push button type start/ stop switch
Auto/manual switch,
Fuel gauge as per existing
Removing dismantling and overhauling of 12 volt starter motor, replacement of armature coil, field coil, bush bearing etc to make the starter motor serviceable complete all as specified and as directed.
M&L for replacement of old unserviceable lead acid battery of size 12 Volts, 100 AH of reputed make including charging and shifting & depositing old battery to MES complete all as specified and directed. Make: Amaron/ Exide/ Tata Green
M&L for replacement of old unserviceable lead acid battery of size 12 Volts, 180 AH of reputed make including charging and shifting & depositing old battery to MES complete all as specified and directed. Make: Amaron/ Exide/ Tata Green
S&F in replacement MCCB, 03 Poles, 415 V, rating 200 Amps of 25 KA Breaking capacity, adjustable overload setting: 0.8 - 1.0 x In, adjustable short-circuit settings: 6 - 10 x In, Ics = 100% of Icu including spreader links, 50 Hz with thermal magnetic release complete all as specified and directed.
S&F in replacement MCCB, 03 Poles, 415 V, rating 63 Amps of 25 KA Breaking capacity, adjustable overload setting: 0.8 - 1.0 x In, adjustable short-circuit settings: 6 - 10 x In, Ics = 100% of Icu including spreader links, 50 Hz with thermal magnetic release complete all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earthing strip of dimension 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including testing complete all as specified and as directed. Note: Necessary excavation to be measured under corresponding item of schedule.
Testing of earth resistance test with well calibrated suitable earth resistance tester after opening the test points and recording the result in presence of MES representative complete all as per IS 3043 of 1966. Note: - (i) The result should be recorded in the result sheet and on building at place directed. (ii) Testing equipment & ladder has to be arranged by the contractor on his own and the rate quoted by the is deemed to be inclusive of this provision.
S&F in replacement factory made precast 1:2:4. type B-0 (using 12.5mm graded stone aggregate) of internal size 400 x 400 x 300 mm & 65 mm thick earth pit chamber box with cover including provision of earthing strip/ GI pipe entry glands complete all as specified and directed.
S&F in replacement of ON load changeover switch, rotory type, 100 Amp, 415 Volt, TPN, front operated without sheet metal enclosure suitable for mounting on existing panel as per site requirement complete all as specified and directed.
S&F in replacement of ON load changeover switch, rotory type, 200 Amp, 415 Volt, TPN, front operated without sheet metal enclosure suitable for mounting on existing panel as per site requirement complete all as specified and directed.
S&F in replacement of ON load changeover switch, rotory type, 63 Amp, 415 Volt, TPN, front operated without sheet metal enclosure suitable for mounting on existing panel as per site requirement complete all as specified and directed.
Deduct amount of Rs. 99787.00 for Schedule of credit (calculation will be done off line)
Neha Enterprises (BID ID -3351417)
MODI CORPORATION (BID ID -3342939)
Aditya Sales Corporation (BID ID -3339245)
PRAGATI ELECTRICALS AND ELECTRONICS (BID ID -3343342)
City buildcom builders & devlopers (BID ID -3342842)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .