Loading…
Loading…
Tender Value
₹75.4 L
EMD Value
₹1.5 L
Closing Date
3 Jul 2026, 11:00 am
Similar tender results from the same govt authority in the past 3 years.
MYS-Construction of First-floor Building at new OPD Block and Improvements to Circulating area including compound wall of Railway Hospital at Mysuru.
Y-E-29-2026-27-33
Y-E-29-2026-27-33
Open
120 Days
Mysuru, Karnataka
₹0
₹1.5 L
12 Jun 2026
12 Jun 2026
19 Jun 2026
deep, re-fitting of soil and re-plastering of excavated trench with cement on the PF's to bring original shape. NS 100.00 Metre 105.00 10500.00 AT Par 10500.00
terminations at both ends. This work includes Extension of power supply from the nearest power supply source in the excavated cable trench/in trough/on building walls/sheds/shelters etc. NS 150.00 Metre 341.02 51153.00 AT Par 51153.00
terminations at both ends. This work includes Extension of power supply from the nearest power supply source in the excavated cable trench/in trough/on building walls/sheds/shelters etc. NS 250.00 Metre 298.00 74500.00 AT Par 74500.00
grade of above 95 sq mm and Up to 185 sq. mm size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. NS 270.00 Metre 140.00 37800.00 AT Par 37800.00 08 MYSORE DIVISION-ELECTRICAL/SOUTH WESTERN RLY
cables and all the ends should be sealing with bituminous compound. NS 36.00 Metre 808.01 29088.36 AT Par 29088.36
clamping, fixing arrangements and sealing with bituminous compound. NS 250.00 Each 545.00 136250.00 AT Par 136250.00
on surface / recess / concealed, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. / casing & capping as per site requirement. NS 80.00 Each 659.00 52720.00 AT Par 52720.00
on surface / recess / concealed, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. / casing & capping as per site requirement. NS 10.00 Numbers 1751.61 17516.10 AT Par 17516.10
including hardware items as required complete. NS 28.00 Numbers 2392.50 66990.00 AT Par 66990.00
warranty for 5 years suitable to work for 230 V, 50 HZ single phase supply as per specifications complete. NS 28.00 Numbers 111.70 3127.60 AT Par 3127.60
and hardware items as required complete. NS 6.00 Numbers 1726.00 10356.00 AT Par 10356.00
as per site requirements including all necessary fixing arrangements complete all as per detailed specification and as per PCEE/SWR specifications. NS 25.00 Numbers 885.50 22137.50 AT Par 22137.50
similar to corvi surface 8 or similar specifications including all other necessary accessories complete. NS 60.00 Numbers 681.00 40860.00 AT Par 40860.00 Description:- Supply, fixing, testing and commissioning of 18 - 22-watt 6500k batten 4 feet
(Indoor/outdoor)/001-2016 effective from 18.04.2016 or latest. Including all other required accessories complete. NS 12.00 Numbers 2073.64 24883.68 AT Par 24883.68
specification SWR/LED LIGHT FITTING (Indoor/outdoor)/001-2016 effective from 18.04.2016 or latest. NS 300.00 Metre 482.00 144600.00 AT Par 144600.00
sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / casing & capping as required at site. NS 600.00 Metre 373.00 223800.00 AT Par 223800.00
sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / casing & capping as required at site. NS 900.00 Metre 311.00 279900.00 AT Par 279900.00
2.5 sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / casing & capping as required at site. MYSORE DIVISION-ELECTRICAL/SOUTH WESTERN RLY NS 180.00 Point 1704.00 306720.00 AT Par 306720.00 Description:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
PVC conduit / Casing & capping, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSH / HFFR PVC insulated copper conductor single core cable etc. as required. (Group - C). NS 1.00 Set 10127.63 10127.63 AT Par 10127.63 Description:- Design, Supply, fixing and commissioning of 12 Way DP Double Door Distribution
sensitivity 30 mA-1 Nos and outgoing SP MCB 6-32A 10 KA - 10 Nos with required suitable hardware and internal wiring complete. NS 2.00 Set 30553.74 61107.48 AT Par 61107.48 Description:- Design, Supply, fixing and commissioning of 12 Way FP Double Door Distribution
sensitivity 30 mA-1 Nos and outgoing TP MCB 63 A - 2 No., SP MCB 6-32A - 16 No's along with TP+N SPD - 1 No. with required suitable hardware and internal wiring complete. NS 2.00 Set 25277.31 50554.62 AT Par 50554.62 Description:- Design, Supply, fixing and commissioning of 12 Way FP Double Door Distribution
mA-1 Nos, TP MCB 40A - 2 No and SP MCB 6-32A - 16 Nos with required suitable hardware and internal wiring complete. NS 8.00 Set 5436.00 43488.00 AT Par 43488.00 Description:- L.T. Earthing arrangements for hard soil using 50 mm C-Class GI Pipe- 2.7 Mtr length,
paint and stenciling of earth resistance value with date, including supply and laying of 6 SWG G.I. wire and other hardware to connect equipment at site complete. NS 48.00 Numbers 505.02 24240.96 AT Par 24240.96
Roma. NS 16.00 Numbers 499.21 7987.36 AT Par 7987.36 32 Description:- Supply and provision of AC operated call bell for 10-meter range. NS 10.00 Numbers 2571.10 25711.00 AT Par 25711.00 33 Description:- Supply, erection, testing and commissioning of occupancy sensor. NS 9.00 Numbers 1290.71 11616.39 AT Par 11616.39
lighting type suitable to show "ENGAGE" in RED colour. NS 1.00 Numbers 109530.00 109530.00 AT Par 109530.00
inbuilt water cooler. RO + UV + Copper as per Detailed Description/ Specification. NS 2.00 Numbers 6740.00 13480.00 AT Par 13480.00
(Stationary Storage Type Electric Water Heaters), Tank Capacity - 15 Liters as per Detailed description/ Specification with suitable water pipes and all other required hardware items complete. NS 2.00 Job 1712.19 3424.38 AT Par 3424.38 Description:- Additions/alterations of interconnectivity of power supply, LTUG Cables for outgoing
consult and obtain permission from Railway Engineers before commencement of work each step/occasion). NS 1.00 Job 6530.39 6530.39 AT Par 6530.39
Commissioning work exclusive of EB Deposit work. 2097147.0 NS 1.00 Job 2097147.07 AT Par 2097147.07 7 Description:- Supply, installation, testing and commissioning of Compact Pre - fabricated Packaged
incoming and following outgoing MCCB feeders and with enclosure made of Galvanized steel sheet (min 2 mm Thickness) with powder coated finish, Cu bus bar with LT Metering facility 250kVA Al. Wound Transformer, 400A MCCB 50kA 4 pole fixed type microprocessor based for LT incomer and 3 Nos. 250A MCCB 4 pole 36kA TM Based for outgoing including cable duct, suitable RCC plinth and GI strip earth connection complete. NS 1.00 Numbers 223975.09 223975.09 AT Par 223975.09 40 MYSORE DIVISION-ELECTRICAL/SOUTH WESTERN RLY 40 Description:- Supply, installation, testing and commissioning of APFC panel of 100 KVAR rating with all other required accessories complete as per detailed specifications. NS 1.00 Set 19818.06 19818.06 AT Par 19818.06 Description:- Supply, fixing and commissioning of FP 4 Way Double Door Distribution Board with
capacity-1 Nos, FP MCB 63 A-1 Nos, SP MCB 16A-2 Nos, SP MCB 6 A-1 No. with required suitable hardware and internal wiring complete. NS 50.00 Metre 959.30 47965.00 AT Par 47965.00
including accessories like bends, elbows, junction box etc. similar to M/s LEGRAND cat No. 638038. NS 24.00 Metre 171.30 4111.20 AT Par 4111.20
accessories like saddles, clamps, G.I nut, bolt, spring, washer etc. as required to provide earth continuity from earth pit to lift well. NS 50.00 Metre 796.94 39847.00 AT Par 39847.00 Description:- Supplying and installing 100mm width X 50 mm depth X 1.6 mm thickness size of
with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I suspenders including G.I bolts & nuts, etc. as required. NS 4.00 Numbers 7696.98 30787.92 AT Par 30787.92
Amps capacity 4 Way Similar to M/s. Havells, SAP Code-IHBC006304 or similar specifications. NS 2.00 Job 1712.19 3424.38 AT Par 3424.38
feeders at PF LT panel board, fixing and mounting work etc., {The tenderer shall be consult and obtain permission with Rly., Engineers before commencement of work each step/occasion}. NS 50.00 KWp 45019.54 2250977.00 AT Par 2250977.00 Description:- Supply, installation, testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended and as per tender conditions, consisting of Topcon or latest solar PV modules as per site requirement, net metering facility, necessary protections, earthing, mounted on GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/IEC61215, IS/IEC61730- Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than
800VDC Input voltage range and 400VAC, three phase, 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97% total harmonic distortion less than and 3% and suitable for ambient temperature from 0 to 50-degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying &fixing of necessary channel/conduit lugs and other accessories etc. NS 2.00 Numbers 130000.00 260000.00 AT Par 260000.00 Description:- Supply, installation, testing and commissioning of Air Source Heat pump with hot
with Power Input: 2.8 KW, Output: 11.2 KW, 3 Ph, 415 volts, 50 Hz and all other as per detailed specifications complete including all necessary connected accessories. NS 2.00 Numbers 55000.00 110000.00 AT Par 110000.00
Tank, 4 mm Shell and 4 mm Dish Thickness, puff insulated Tank, Max test 5 bar, Max Working pressure 4 bar, Vertical Tank. NS 2.00 Numbers 28000.00 56000.00 AT Par 56000.00
to Tank Inlet / Outlet plumbing materials Charges.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Booklet
ATTACHMENT
GCCApril-2022.pdf
ATTACHMENT
JPOintenderdocumnets.pdf
ATTACHMENT
AdvanceCorrectionSlips1-11toGCC-2022.pdf
ATTACHMENT
TB-NewOPDblockandimprovementstocirculatingareaatRailwayHospita._1.pdf
ATTACHMENT
Download all tender documents and submit your bid