Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹23.0 L+₹53,012.25 (2.36%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹23.6 L+₹1.2 L (5.29%)Rejected-Finance 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721305 | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹23.8 L+₹1.3 L (5.97%)Rejected-Finance | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹25.6 L+₹3.1 L (13.8%)Rejected-Finance 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance Being higher bidder |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
13 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TECH AREA AGRA
GE AF TECH AREA AGRA
REPAIR AND MAINT OF HIGH MAST LIGHT TARMAC LIGHT AND CONNECTED ITEM UNDER GE AF TECH AREA AGRA
2023_MES_595909_1
8200-1527/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF TECH AREA AGRA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF TECH AREA AGRA
₹91,000
Yes
3 Aug 2023
16 May 2023
15 Jun 2023
16 May 2023
13 Jun 2023
30 May 2023
17 May 2023 - 23 May 2023
Amount
Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in soil complete all as specified and directed.
Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed.
M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover, laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
Labour only for re-laying of old serviceable bricks retreived from Item No. 1 here-in before for cable protection cover, laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
M&L for local sand coushioning with dry and clean sand over and under the cable for protection of cable , 80 mm thick sand laid before laying the cable 150 mm thick sand after laying the cable complete all as specified and directed. Note : Thickness of sand will be measured after punning for payment purpose.
Taking out old serviceable/ unserviceable LT UG cables of any size of 10 to 70 sq mm, 2/3.5/4 core from trenches, poles/walls and floor includuing taking out old serviceablee bricks from trenches complete all as specified and directed.
Laying only serviceable XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of following sizes laid in trenches or fixed on walls/floor/pole complete all as specified and as directed.
10 sqmm to 70 Sqmm 3.5/4 core
Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of the following sizes laid in trenches or fixed on wall/floor/poles complete all as specified and as directed :-
10 Sq mm 4 core
16 Sq mm 4 core
25 Sq mm 4 core
35 Sq mm 3.5 core
50 Sq mm 3.5 core
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. Note : Cost of equipment, T&P, material required for boring & HDPE pipe deemed to be included in the quoted rate.
Supply and fixing of GI tubing 'light grade' of 40 mm bore for cable protection fixed on pole/wall/floor/or laid in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket complete all as specified and directed.
M&L for jointing kit suitable for LT 1100 volts cable (earthed) for out door straight through joint, heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-
25 to 50 Sqmm 3.5/4 core
70 to 120 Sqmm 3.5 core
M&L for End jointing kit suitable for LT 1100 volts cable (earthed) for out door heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-
10 to 50 Sqmm 3.5 core
70 to 120 Sqmm 3.5 core
Supply and fixing in repair LED flood light fitting 150 watt with and including all fixing arrangement high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete all as specified and directed.
Supply and fixing in repair LED flood light fitting with and including all fixing arrangement high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 200 watt complete all as specified and directed.
Supply and fixing in repair LED flood light fitting with and including all fixing arrangement high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 250 watt complete all as specified and directed.
Taking out lantern carriage of high mast light fitting with the help of integral power tools for repair and maintenance of unserviceable parts of any capacity and type including replacement of defective parts with new parts (items replaced shall be measured and paid seperately as "supply & fixing in repair") and made the fittings serviceable and re-fixing the lantern carriage at the original position complete all as specified and directed.
Supply and fixing in repair LED aviation obstruction light in red colour with 48 W capacity by lowering the lantern removing the old light and refixing the new one and raising the lantern in same position with coonected accesssories complete all as specified and directed.
Supply and fixing in repair copper conductor of size 5core, 2.5 Sqmm rubber insulated and cotton braiding over the laid up cores pvc sheathed flexible type for highmast trailing rubber cable including removal of old cable and reconnecting with proper size of thimble and connected accessories complete all as specified and directed.
Supply and fixing in repair copper conductor of size 1.5 sqmm three core for highmast light connnection including connected accessories complete all as specified and directed.
Supply and fixing in repair stainless steel wire rope grade- AIAI 304, 7/19 construction of dia 6mm with breaking load capacity as per standard norms for highmast including removal of old wire rope and reconnection with proper connected accessories complete all as specified and directed.
S& F in repair Diamond chain B.S (I) 3/8 suitable for highmast motor roatation with connected accessories including taking down old sprocket and replaced with all fixing arrangment complete all as specified and directed.
S& F in repair sprocket 3/8 with Hub TH-14 heavy duty suitable for highmast motor and roatary part with connected accessories including taking down old sprocket and replaced with all fixing arrangment complete all as specified and directed.
Supply & fixing in Replacement of control panel outdoor type size 500x775x250 made of 14 SWG CRCA sheet with, IP-55, stand (made of 40x40x5 mm MS angle) mounted feeder piller with including aluminium busbar-4 nos 63 A internal wiring with 6 Sqmm copper wire for 32A circuit and 2.5 Sqmm for others. Complete for autometic, timely Off/On for operating 6 to 10 Nos) 250 watt LED light fitting and comprising the following:- (i) Incoming 32 A 4pole MCB isolater- 01 no. (ii) 22A TP Contactor- 01 No. (iii) 9A contactor- 02 nos. (iv) Single dial timer switch - 01 no. (v) Push button- 02 No. (vi) Outlet Terminal- 02 nos. (vii) Toggle switch- 01 no (viii) Neutral link- 01 no (ix) Glass fuse- 01 no
M & L for repair of control panel of high mast light fitting complete with checking all electrical wiring and contactor including removing the old burnt control wiring from the panel and re-wiring with new PVC insulated copper cable single core multi strand with existing size and made the panel serviceable including testing after completion of work complete all as specified and directed.
Supply and fixing MCB FP 40 t0 63 Amps, 230 volts, 10 KA with enclosure in existing highmast panel complete all as specified and directed.
Supply and fixing MCB SPN 6 to 32 Amps, 230 volts, 10 KA with enclosure in existing highmast panel complete all as specified and directed.
Supply and fixing MCB SP 6 to 32 Amps, 230 volts, 10 KA with enclosure in existing highmast panel complete all as specified and directed.
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box with 4 aluminium strip bar(25x3 mm) , having protection class IP-65 and of overall size 205mm x 255mm x 112mm having metric knockouts on the wall, having three phase cable connecter, duly fixed with the pole with clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB complete all as specified and directed.
Supply and fixing in repair three phase motor of capacity 1 HP with reverse and forward moving ,6 pole single speed suitable for high mast complete all as specified and directed.
Repair/Maintenance winch/power tool double drum type/350 Kg suitable for lowering and raising the highmast lantern including dismantling of winch/power tool and refixing after repair with connected accessories complete all as specified and directed.
M&L for re-winding of existing highmast three phase motor of capacity upto 1.5 HP with reverse and forward moving ,6 pole single speed suitable for high mast including dismantling of motor and refixing after rewinding in same position with connected accessories complete all as specified and directed.
Repair & maintainenace three phase motor of capacity 1 HP with reverse and forward moving ,6 pole single speed suitable for high mast including dismantling of motor and refixing after repair/servicing in same position with connected accessories complete all as specified and directed.
M & L Painting to existing LT Panels, angle iron support bracings, clamps etc. with two coats of aluminium paint superior quality of approved make on surfaces exposed to view external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
M & L Painting to existing light pillar with two coats of synthetic enamel paint of superior quality of approved make on surfaces exposed to view external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
Demolition of PCC/Black bituminous road of any description and in any position not otherwise specially provided , etc complete all as specified and directed.
M&L for Cement Concrete (1:2:4) type B1 using 20 mm gradded stone aggregate for coping of poles, panel board and filling of road cutting etc complete all as specified and as directed.
S & F in repair cage for protection/housing LED lights made out of 4mm dia GI wire along with suitable size of angle iron frame fixed on foundation with necessary anchor fastner and nut bolts etc complete the size of cage should be 550x450x550 mm including one side with cage opening and locking arrangement and painted with black super enamel paint over a coat of red oxide primer etc complete all as specified and directed.
Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.00mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate shall be at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 25 x 4 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by 40 mm dia GI pipe light grade connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforced with 8mm dia TMT bar at 75 mm c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus soil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 600mm width x 600mm Height (With Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 200 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) type B0 all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation complete all as specified and directed.
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 500mm width x 500mm Height (With Canopy & Base Channel) x 300mm Depth, M.S. Channel Base Frame mounted suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of size 100 Sqmm for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) type B0 all as directed by Engr-in-charge. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation complete all as specified and directed
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar Box of overall size not less than 900mm width x 1000mm Height (Without Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame (to be mounted on the angle iron frame of suitable size gouted with PCC(1:2:4) Type B0 , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 300 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication House who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) Type B0. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 300 amps, . For all internal connections from main bus bars to MCCBS shall be carried out with heat shrink type PVC insulated aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 25 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 160 Amps-01 Nos.
OUTGOINGS :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA and thermal setting from 80% to 100% and of ratings :-63Amps - 01 Nos (ii) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA and thermal setting from 80% to 100% and of ratings :-40 Amps - 02 Nos MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 03 Nos. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED suitable for 230 Volts AC - 01 set of 3 lamps (RED,YELLOW & BLUE) Digital Multifunction meter - 01 N0 C.T having Ratio 250/5, tape wound,BPL, rated burden 5 VA - 03 Nos. Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar Box of overall size not less than 1100mm width x 900mm Height (With Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame (to be mounted on the angle iron frame of suitable size gouted with PCC(1:2:4) type B0) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 300 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication House who posseses test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the angle iron frame of suitable size gouted with PCC(1:2:4) type B0. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 300 amps, . For all internal connections from main bus bars to MCCBS shall be carried out with heat shrink type PVC insulated aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 25 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 200 Amps-01 Nos.
OUTGOINGS :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA and thermal setting from 80% to 100% and of ratings :-63Amps - 04 Nos MISCELLANEOUS ITEMS :- (a) SP MCB 6 Amps 10 KA (For Control Wiring) - 03 Nos. INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED suitable for 230 Volts AC - 01 set of 3 lamps (RED,YELLOW & BLUE) Digital Multifunction meter - 01 N0 C.T having Ratio 250/5, tape wound,BPL, rated burden 5 VA - 03 Nos. Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos
Unnati Engineers
Star Enterprises
Balaji Associate
M/s SCHOLASTIC ENTERPRISES
M/s Sumer Associates
TRIVENI ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .