Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 15 BAGHE ISLAM NEAR NH BY PASS BRIDGE LAL NAGAR CHANAPORA SRINAGAR JAMMU KASHMIR 190015 | SRINAGAR | JAMMU AND KASHMIR | 190015 | Admitted-Finance |
Tender Value
₹26.4 L
EMD Value
₹53,000
Closing Date
12 Feb 2021, 6:00 pmClosed
GE 970 EWS
GE 970 EWS C/o 56 APO
REPAIR AND MAINT OF INTERNAL WIRING INCL ELECTRIC FITTING AND FIXTURE IN OTM/MD ACCN AT HAFT CHINAR TATOO GROUND AND SONAMARG UNDER GE 970 EWS
2021_MES_415343_1
GE 970 EWS-66/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Haft chinar, tattoo ground
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹53,000
Yes
9 Apr 2021
22 Jan 2021
15 Feb 2021
22 Jan 2021
12 Feb 2021
5 Feb 2021
Amount
Taking down old and unserviceable submain wiring/ service cable any size of two core including earth wire complete including batten/ conduit and make good the disturbed surface to match the existing surface, all as directed by Engr-in-charge.
Taking down carefully existing point wiring aluminum/ copper conductor for light or fan or socket or power etc on wooden batten or in conduit including fittings and accessories like switches, sockets, wooden board and making good disturbed portion to match with existing complete all as specified and directed.
Taking down old and unserviceable, distribution board any type including fuses, MCBs etc after removing all connections and making good the disturbed surface all as directed by Engr-in-charge
Material & labour for point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLS) drawn through and including PVC concealed conduit 25 mm bore (ISI marked) and accessories (concealed in wall & surface in ceiling complete including cutting ,chases & making good disturbed surfaces), terminated in and including pressed steel terminal boxes with plastic laminated backlite sheet top cover 3 mm thick (hylum) fixed with nickel polished screws with washers, earth continuity PVC cable(FRLS), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly One light point / fan point / bell push point controlled by one way switch 5 Amprs and/or through regulator complete all as specified and directed. complete all as specified.
All as per description of srl item No 4 here-in-before but socket out let 3 pin, 5 Amp on same board with other switch.
All as per description of srl item No 4 here-in-before but socket out let 3 pin, 5 Amp on independent board with other switch.
All as per description of srl item No 4 here in before but using 4 sqmm (nominal area) PVC stranded copper conductor cable with 1.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin socket out let 15 Amps on independent board.
All as per description of srl item No 4 here-in-before but one light point controlled by two way switches..
Supply and fix sheet metal enclosures for DB's with 200 Amp rated bus bar double door class IP-43 epoxy coated inside and outside 4 way TPN 415 volts complete all as specified and directed.
Supply and fix sheet metal enclosures for DB's with 200 Amp rated bus bar double door class IP-43 epoxy coated inside and outside 8 way SPN 240 volts complete all as specified and directed.
Supply and fix sheet metal enclosures for DB's with 200 Amp rated bus bar double door class IP-43 epoxy coated inside and outside 12 way SPN 240 volts complete all as specified and directed.
Supply and fix in repair MCB TPN 63 Amp, 240 volts,10 KA, complete all as specified and directed. Make: Havells DHMCDFP063 in 'D' Series/ L&T/SCHNIDER
Supply and fix in repair MCB SPN 63 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. Make: Havells Cat No DHMGCSNF040 IN "C' Series/ L&T/SCHNIDER
Supply and fix in repair MCB SPN 40 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. Make: Havells Cat No DHMGCSNF040 IN "C' Series/ L&T/SCHNIDER
Supply and fix in repair MCB SP 6 to 32 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. Make: Havells Cat No DHMGCSNF6-32 IN "C' Series/ L&T/SCHNIDER
Supply and fix in repairs switch piano flush type, 5 Amps, 240V AC, single pole, one way complete all as specified and directed .
Supply and fix in repair Socket outlet 3 pin, 5 Amp, 230 V AC complete all as specified and directed.
Supply and fix in repair Switch socket combination 2 in 1, 5 Amps 240 V AC flush type universal, complete all as specified and directed.
Supply and fix in repair Switch socket combination 5 in 1, 3 pin 5/15 Amps 240 V AC flush type universal, complete all as specified and directed.
Supply and fix in repair switch piano flush type, 5 Amps, 240V AC, single pole, two way complete all as specified and directed.
Supply and fix in repair Ceiling rose 2/3 terminals all as specified and directed
Supply and fix in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as directed and specified by Engr-in-Charge.
Supply and fix in repair Lamp holder batten/angular type complete including 1x7W LED lamp all as specified and directed.
Supply and fix in repair of 1X5 Watt lamp LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, extruded plastic and decorative end cap body heat shrink, provided for efficient dissipation and integraded electronic driver complete all as specified and directed .
Supply and fix in repair of 1X10 Watt lamp LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, extruded plastic and decorative end cap body heat shrink, provided for efficient dissipation and integraded electronic driver complete all as specified and directed .
Supply and fix in repair of 1X15 Watt lamp LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, extruded plastic and decorative end cap body heat shrink, provided for efficient dissipation and integraded electronic driver complete all as specified and directed .
Supply and fix in repair 1X18 watt 4 ft long LED Batten housing made of extruded alluminium with milky white diffuser and inbuilt electronic driver system lumen output should be at least 1800 lumen with a CCT of 6000 K, power factor should be greater than 0.95 with all accessories and connecting up with 3 core flexible cable white of size 23/0.0076 complete all as specified and directed. make : Havells Cat part No : LHEXBQP6IN1W018 or equivalent in : BAJAJ /Philips/CG. Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. (ii) Contractor shall produce LM-79 & LM-80 report of NABL accedited labortory from manufaturers.
Supply and fix in repair Fluorescent tube light fitting, LED batten with aluminium housing provided for efficient heat dissipation wirh polycarbonate diffuser and integrated electronic driver, 1x 9 watts 2 feet light fitting with white acrylic cover along with LED lamp white colour complete and connecteing electrically to ceiling rose using PVC insulated and overall sheated flexible copper conductor of size 0.75 Sqmm 3 core fixed complete all as specified and directed. make : Havells Cat part No : LHEXBTP7UN1W09 or equivalent in : BAJAJ /Philips/CG Note (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. (ii) Contractor shall produce LM-79 & LM-80 report of NABL accedited labortory from manufaturers.
Material and labour for sub main wiring with two runs of single core PVC insulated (FRLS) unsheathed copper conductor multistranded cable of size 4 sqmm 1100 volts grade drawn through in & including PVC conduit 25mm dia & 2.5 sqmm single core copper conductor multistranded PVC insulated (FRLS) unsheathed cableas earth wire continuity conductor complete all as specified and directed by Engineer in charge. Note : (i) Two run of cable 4 sqmm and one run of 2.5 sqmm earth wire shall be measured and paid as one unit only. (ii)Phase should be Red / Yellow / Blue, neutral should be black and earthing wire should be green in colour
Material and labour for sub main wiring with two runs of single core PVC insulated (FRLS) unsheathed copper conductor multistranded cable of size 6 sqmm 1100 volts grade drawn through in & including PVC conduit 25mm dia & 4 sqmm single core copper conductor multistranded PVC insulated (FRLS) unsheathed cableas earth wire continuity conductor complete all as specified and directed by Engineer in charge. Note : (i) Two run of cable 6 sqmm and one run of 4 sqmm earth wire shall be measured and paid as one unit only. (ii)Phase should be Red / Yellow / Blue, neutral should be black and earthing wire should be green in colour
Material and labour for sub main wiring with two runs of single core PVC insulated (FRLS) unsheathed copper conductor multistranded cable of size 10 sqmm 1100 volts grade drawn through in & including PVC conduit 25mm dia & 6 sqmm single core copper conductor multistranded PVC insulated (FRLS) unsheathed cableas earth wire continuity conductor complete all as specified and directed by Engineer in charge. Note : (i) Two run of cable 10 sqmm and one run of 6 sqmm earth wire shall be measured and paid as one unit only. (ii)Phase should be Red / Yellow / Blue, neutral should be black and earthing wire should be green in colour
Supply and fix in repair switch bell push flush type, 5 Amps, 240V AC, single pole, one way complete all as specified and directed
Supply and fix in repair call bell, multi music type AC single phase, 230 volts including wooden/ PVC board of suitable size, connecting & testing complete all as specified and directed.
Material and labour in repair for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of theplate not less 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continuous earth wire on pole, testing the earthing after completion complete all as specified and directed. Note :- (I) Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit (II) PCC chamber shall be (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways complete all as specified and directed.
Javeed And Co
M/S RAFIQ AHMAD SOFI AND SONS
M/S B A Traders
M/S U.K. ENTERPRISES
M/S Manzoor and Co
M/S M.Y Enterprises
SOFI CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .