Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.7 LQualified Make: APCOM
Model: APCOM , BC-1ST 12V 12A 109 SHIVA MARKET PITAMPURA DELHI NORTH WEST DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Make: APCOM
Model: APCOM , BC-1ST 12V 12A | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
23 Jun 2018, 10:00 amClosed
battery chargers Average Turn Over of Last 3 Years 1000000 Lakh (s) Experience with Gov. Required 5 Year (s) Battery Chargers ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology Transformer Based Transformer Based
SMPS Based Compatibility with battery type (User Selectable) Tubular Tubular
Lead acid
VRLA- SMF
Tubular & VRLA-SMF
Lead acid & VRLA- SMF
Tubular & Lead acid
Lead acid & Tubular &VRLA-SMF Number of Independent charging stations (in numbers) 1 1
3
5 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) - AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) - Soft start and Soft stop feature without inrush Yes - 1/4 current Facility for charging deep discharged battery through pulse charging. yes - Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes - Digital display of output voltage and current Yes - LED Indication for Charging Status
Charged condition status and reverse polarity Yes - Cabinet Material CRCA Sheet - Cabinet Thickness (mm) minimum 1.2 mm - Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) - Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station - FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station - Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH - Maximum Charger output current (Amp) 12 Ampere per station - Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt - Efficiency (%) >/= 75% - Ripple (Peak to Peak at Full Load) (millivolts) <100 - Reverse Polarity Protection Yes - Short Circuit Protection Yes - Over Current Protection Yes - Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at - 2/4 270 volt when the voltage is reduced from 280 volt Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt - Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt - Minimum operating temperature (Degree Celsius) -10 - Maximum operating temperature (Degree Celsius) +55 - CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes - Type Test report No. fcbc24v48v25amps - Test report date 24-04-2018 - Name of Lab Premier Sales Corp. - Address of Lab Janak Puri
New Delhi - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sudipto Roy 194101
14 CORPS ENGINEERING SIGNAL REGIMENT
NEAR LEHO OFFICE
SKARA
YOKMA
LEH - LADHAK - 194101 30 15 EMD Required No ePBG Required No
227861
GEM/2018/B/32423
battery chargers
15 days
Ladakh; Leh Ladakh
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| battery chargers Average Turn Over of Last 3 Years 1000000 Lakh (s) Experience with Gov. Required 5 Year (s) Battery Chargers ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology Transformer Based Transformer Based | - | - | - |
| SMPS Based Compatibility with battery type (User Selectable) Tubular Tubular | - | - | - |
| Lead acid | - | - | - |
| VRLA- SMF | - | - | - |
| Tubular & VRLA-SMF | - | - | - |
| Lead acid & VRLA- SMF | - | - | - |
| Tubular & Lead acid | - | - | - |
| Lead acid & Tubular &VRLA-SMF Number of Independent charging stations (in numbers) 1 1 | - | - | - |
| 3 | - | - | - |
| 5 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) - AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) - Soft start and Soft stop feature without inrush Yes - 1/4 current Facility for charging deep discharged battery through pulse charging. yes - Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes - Digital display of output voltage and current Yes - LED Indication for Charging Status | - | - | - |
| Charged condition status and reverse polarity Yes - Cabinet Material CRCA Sheet - Cabinet Thickness (mm) minimum 1.2 mm - Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) - Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station - FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station - Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH - Maximum Charger output current (Amp) 12 Ampere per station - Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt - Efficiency (%) >/= 75% - Ripple (Peak to Peak at Full Load) (millivolts) <100 - Reverse Polarity Protection Yes - Short Circuit Protection Yes - Over Current Protection Yes - Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at - 2/4 270 volt when the voltage is reduced from 280 volt Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt - Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt - Minimum operating temperature (Degree Celsius) -10 - Maximum operating temperature (Degree Celsius) +55 - CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes - Type Test report No. fcbc24v48v25amps - Test report date 24-04-2018 - Name of Lab Premier Sales Corp. - Address of Lab Janak Puri | - | - | - |
| New Delhi - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sudipto Roy 194101 | - | - | - |
| 14 CORPS ENGINEERING SIGNAL REGIMENT | - | - | - |
| NEAR LEHO OFFICE | - | - | - |
| SKARA | - | - | - |
| YOKMA | - | - | - |
| LEH - LADHAK - 194101 30 15 EMD Required No ePBG Required No | - | - | - |
Exempted
24 Jun 2018
19 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_227861.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .