Loading…
Loading…
Tender Value
₹2.4 Cr
EMD Value
₹2.7 L
Closing Date
16 Apr 2026, 12:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER SEC
17 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less ; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfillment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference. (Ref:- GM/Engg. letter no. CE/G/Arb & Cont. Mgt./Tender Circular/Pt. I/317 dtd. 11.03.2025)
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Similar nature of work means- "Any work of supply, installation, testing and commissioning of Railnet Network or any networking system using switches / Router/Wi-Fi/ IP based CCTV in govt. Sector/ Semi Govt. / Govt. undertaking / PSU - Indoor/Outdoor"
Tenderer should submit relevant document regarding completion and execution of any of the work mentioned in para 1.1 above for fulfilling Technical Eligibility Criteria of Similar Nature of Work.
30 conditions · 3 needing a document upload
GST Registration details should be attached
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017(CGST)/ Integrated Goods and Services Tax Act, 2017(IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also,as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding.Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under GST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/ UTGST/ SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority.
In case the successful tenderer is not liable to be registered under GST/IGST/UTGST/ SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
JPO to prevent the damages of underground utilities :- The contractor shall conform to JOINT PROCEDURE ORDER in connection to procedure for undertaking digging work in vicinity of underground utility of various departments viz Signalling, Telecom and Electrical cables - preventive and post cable cut measures (Ref:- RB Letter No. 2021/Tele/5(2)/3-Part (1) (3425647) dtd. 12.06.2023 ). The biddder is requested to go through the same (copy attached) before quoting their offer. The stipulations of the JOINT PROCEDURE ORDER in connection to procedure for undertaking digging work in vicinity of underground utility of various departments viz Signalling, Telecom and Electrical cables - preventive and post cable cut measures are to be strictly followed till the currency of the contract.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfillment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference. (Ref:- GM/Engg. letter no. CE/G/Arb & Cont. Mgt./Tender Circular/Pt. I/317 dtd. 11.03.2025)
Before execution of contract agreement, the contractor must submit tender specific authorization issued by OEM for Schedule B item no. 1 and 2 clearly specifying that,1) Technical support for supply, testing and commissioning of the above equipment and/or software. 2) Technical support during the warranty period as and when required.
Supply, Installation, Testing and Commissioning of Yard CCTV surveillance system in Phase I over 9 Stations in Kharagpur Division.
ST-OT-Yard-CCTV-KGP-Ph_I
ST-OT-Yard-CCTV-KGP-Ph_I
Open
Works - General
15 Months
Paschim Medinipur, West Bengal
₹0
₹2.7 L
16 Apr 2026
23 Mar 2026
2 Apr 2026
54 items across 2 schedules · ₹2,35,98,949.63 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of 3 KVA online UPS with 120 minutes battery backup. The detailed specification is as under, I/P - single phase 160-260 volt, O/P voltage single phase 230+-1%, output frequency 50+- 0.5% Hz , Technology - IGBT-PWM or better, Overall Efficiency (%)- >/=90% & <94% without Inbuilt isolation transformer, Power Factor Load Supported - 0.8 or better, Trolley Material - CRCA Steel, Degree of protection - minimum IP 20, Thickness of sheet for trolley minimum - 1.2 mm. Battery type - SMF/VRLA conforming to JISC:8702(Pt. I, II & III), Stationary Lead Acid Batteries (with tubular positive plates) in monobloc container conforming to IS:13369:1992 latest or better. Minimum Guaranteed VAH - 9600 & other accessories - 6 m cables, rack for batteries etc. Make- Luminous/V-Guard/Exide/Microtek or better. | Numbers | 9.00 | 1,15,107 | 10,35,963 |
| 2 | Depth 1.0 meter, Width 0.3 meter. | Kilometre | 18.00 | 79,869 | 14,37,642 |
| 3 | Excavation of trenches including clearing of roots of trees etc. in hard/rocky soil by chiselling up to a depth of 0.5 meter to 0.8 meter and width 0.3 meter at the bottom. Supply & placing split RCC pipes with collar (for jointing pipes) of 100 mm nominal diameter to Spec. No. IS: 10262- 2019 or latest and IS-456-2000 as per SEM Drawing No. 15- D3 (Sheet-2) on sieved soil of 30 mm over cable and concreting(1:2:3) throughout the length upto a layer of 75mm approximately, then back filling the trench by digging and carrying earth from a distance of maximum 30 meters and then ramming of soil after cable laying. This also includes supply of collar and all the materials for concreting by the contractor. | Metre | 1200.00 | 589 | 7,06,800 |
| 4 | Excavation of trench in all kinds of soils including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 mtr. Track/ Pucca road/Platform crossing/ Level crossing as per SEM Drawing No.15-D5 including supply, transportation and laying of DWC pipes (full) with collar(for jointing pipes) Inner diameter/Outer diameter:103mm/120mm to Specification No.14830 (Part-2):2001 as per SEM Drawing No. 15-D4 and drawing of cable through DWC pipes with collar(for jointing pipes) including back filling and ramming after cable laying as specified in Tech. Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables or any latest guidelines. This includes repairing and plastering of Platform/Pucca road after cable laying. | Metre | 500.00 | 691 | 3,45,500 |
| 5 | Cutting and smoothening of inside surface of sizes 80 mm deep and 170 mm width for single/multiple cable chase in concrete or hard rocks or platform or cemented floor. This work includes laying and covering of cable laid in the chase with standard sizes Second class/Fly Ash brick placed and embedded longitudinally and plastered on the top of the bricks and curing 72 hrs. as per Drawing No. Con/SK/T/1 Note: Sundries materials such as Bricks, sand, cement etc., shall be supplied by the contractor at site and to be inspected by Railway Site Engineer before placing in the chase. Note: In case, chase cutting & smoothening are other than prescribed depth & width, Proportionate payment shall be released. | Metre | 300.00 | 256 | 76,800 |
| 6 | 1 HDPE pipe | Metre | 1940.00 | 1,376 | 26,69,440 |
| 7 | Supply, transportation and fixing of Galvanised Iron Pipe (make: TATA/Jindal or better) with threaded collars (for jointing pipe) of 80 mm nominal bore Specification No. IS: 1239, Pt-1, 2004 thickness 3.2 mm medium grade, on bridges, culverts, drain or at places as per instruction of the site Engineer including supply and transportation of materials required for fixing the pipe as per SEM Drawing No.15-D7 on culverts and others including drawing of cables inside the pipe with masonry work at bridge entry and exit of the culvert and curing for 72 hours and pipes are to be clamped at max. 2 meter apart with drilling of holes on the pipe at 10 cm apart for S&T Cables. Note:- This also includes dismantling of released GI Pipe/Trough and released material should be returned at concerned store. | Metre | 90.00 | 1,018 | 91,620 |
| 8 | Supply of HDPE pipe as per Specification No. RDSO/SPN/TC/45/2013 Rev-2.0 or latest with OD/ID of size 40mm/33mm with suitable couplers, plugs, end caps, spacer, T band etc. as required during execution at the site. | Kilometre | 40.00 | 56,520 | 22,60,800 |
| 9 | Transportation of cables in rolls with or without wooden drums (S&T Cables) from concerned store to the site of works. Note: The unit Drum-KM indicates Drum X length of cable in that drum. It doesn't have any significance over the distance it has to be carried for execution of the work. | Drum-Km | 20.00 | 2,328 | 46,560 |
| 10 | Laying of S&T Cables (Signal/Quad/Power) in the excavated trench to Drawing No. CON/SK/T/5 or latest. Supply and transportation of 'U' clamps, anchoring of cable at every 10 metres interval with 'U' clamp on trench to Drawing No. CSTE/CON /CABLES/81 or latest. Supply, transportation, and placing of cable demarcating led belt to Drawing No. CON/SK/T/6 or latest punched at an interval of 30 metres and wrapped round each cable throughout the cable route and also at every track/Road/ platform crossing as above specified in Technical Circular No. 2/1988 & 01/2010 issued by CSTE/SER or as per latest guidelines and guarding the cables. Collecting empty drums with left over cable and to be returned to the stores of stock holder. Note: Cables will be meggered before & after its laying by contractor under supervision of Railway representative & Contractor will submit their reports. | Kilometre | 19.40 | 20,239 | 3,92,636.6 |
| 11 | Blowing/Drawing/Pulling of OFC cable through already laid HDPE duct /GI pipe /DWC pipe etc. | Metre | 19400.00 | 16 | 3,10,400 |
| 12 | Laying of HDPE duct in trench and its protective work as per direction of site engineer. | Metre | 40000.00 | 6 | 2,40,000 |
| 13 | Supply of Steel Apparatus case Full height as per Drawing No. SK/Drg./OL/SER /198 or latest with E type lock . E-type lock & their key ward No. will be decided by site engineer as per Specification No. IRS: S-10/78 with Rev. 8 or latest. Supply of Hylam sheets is not covered under this scope. This includes supply of one key & handle for each four Apparatus Case or minimum one. | Numbers | 5.00 | 17,430 | 87,150 |
| 14 | Execution of Full Apparatus Case with earth excavation for pit, concrete foundation, surrounding earth work, erection and installation as per Drawing No. Con/SK/T/8 or latest and wiring to be done as per SEM Drawing No.19-D8 or as per direction of site engineer. Supply and fixing of Hylam sheet strip of appropriate size of 3 mm or 6 mm as required with hole for fixing of terminals, fuse blocks, relay and other accessories for signal/track circuit, termination of cable with number embossed ferrules, bunching of cables with PVC tape, proper soldering of cable armour with earth catenary wire, earthing of cable armour as required. Writing & terminal description including Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anticorrosive paint and subsequent two coats of Aluminium paint outside and red oxide inside and lettering etc. This also includes transportation of 25 mm/12mm Hylam sheet for shelf or as required and also includes minor modification in L/Boxes as per site requirement. The contractor shall supply 4 no. of foundation nuts & bolts of size 22 mm dia. x 450 mm long with 2 flat spring washers, with each nut & bolts, sand for filling up cable pit inside the apparatus case including plaster and bolts, nuts, screws, MS Clamps for fixing equipment/cable. Note: - Part payment shall be released after completion of- (i) Foundation- 40%, (ii) Erection - 10%, (iii) Wiring, earthing, testing - 20%, (iv) Painting, writings - 10%, (v) Plastering, sand filling & etc. - 10%, (vi) Commissioning - 10%. | Numbers | 5.00 | 9,147 | 45,735 |
| 15 | Supply of 6 Core Armoured Mono mode OFC cable as per latest TEC Specification or latest. | Kilometre | 20.00 | 22,614 | 4,52,280 |
| 16 | Supply of PVC insulated 3 Core 2.5 sq.mm Single core Multi-strands copper conductor with ISI marked conforming to IS:694/2010 or latest. | Metre | 19400.00 | 104 | 20,17,600 |
| 17 | Supply of DC-DC converter 110/(40 - 60 V , 5A) as per Specification No. RDSO/SPN/165/2023 Ver. 4.0, Amdt.1 or latest. It should be compatible with existing system as specified by Railway in charge. | Numbers | 36.00 | 13,978 | 5,03,208 |
| 18 | Supply of basic material to construct unit Maintenance Free Earth for Single Earth consisting as per Spec. No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/ RDSO/E&B/002 or latest are as under, (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 No. (c ) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1 No.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 No. (e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 No. It also includes supply of (i) 35 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.-10 meter (ii) 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 meter (iii) 10 Sq. mm Multi- strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipment to SEEB- 10 meter. | Set | 9.00 | 17,719 | 1,59,471 |
| 19 | Installation of Single Maintenance Free Earth pit as per RDSO Drawing No. SDO / RDSO/ E&B/001 which includes the following, a) Digging/Auguring/Boring of single earth pit of 100mm to 125mm dia. to the depth of approx. 3 meter. b) Insertion of 3.0 meter electrode and penetrating it minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 200 x 25 x 6 mm. (e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders etc. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish, Inspection chamber should be as per IEC 62561-5 or latest. The top RCC cover size shall be 400 mm X 400 mm X 50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint or as per instruction of site engineer. | Set | 9.00 | 6,098 | 54,882 |
| 20 | Supply of Class B & C Surge protection Device (SPD) -Type I & II with Visual Indication and Potential free contact to remote monitoring as per Specification No. RDSO/SPN/165/2023 Ver 4.0 or latest and IEC standard 61643 or latest and IEC 62304-5 or latest for Single phase 230V AC application with handling Lightning surges of 10/350 microseconds and Switching surges of 8/20 microseconds .One Set consists of 3 nos. of SPD (2 No. of B Class (L-N, N-E) and one no. of C Class (L-N) all enclosed in a Box with KEMA or VDE certified as per latest IEC 61643-11-2011 Standard or latest. Class B & C Surge protection device required with Three modules only. | Set | 86.00 | 6,007 | 5,16,602 |
| 21 | Installation of Class B & C Surge protection Device (SPD) -Type I & II. All fitting material to be provided by the contractor. | Set | 86.00 | 443 | 38,098 |
| 22 | Supply of Fibre Distribution Management system (FDMS)/LIU for 12 Fiber complete with all accessories such as patch cord & pigtail as per TEC Spec. GR/FDM/01/02 April'2007 or latest. This includes supply of installation accessories as per technical specification. | Numbers | 36.00 | 2,604 | 93,744 |
| 23 | Installation, splicing and commissioning of Fibre Distribution Management system (FDMS) for 12 Fiber complete with all accessories with patch cord & pigtail as per TEC Spec. with latest amendment. The sundry material if required any to be supplied by contractor. | Numbers | 36.00 | 2,086 | 75,096 |
| 24 | Supply, transportation and installation of joint enclosure for 6/12 fibres optical fibre cable complete with all accessories including sealing with mechanical clamp facility for splicing of Optical Fibre cable. | Numbers | 104.00 | 1,502 | 1,56,208 |
| 25 | Splicing of Optical Fiber Core and routing in joint closure/FDMS as per instruction of site Engineer. | CORE | 408.00 | 152 | 62,016 |
| 26 | Supply of 24U Rack with 19 inch standard dimension, wall mounting, front glass door with lock and two key, with rack fixing Multi point AC power strip, cable organiser with wall fixing screws. Make: CP Plus, D-Link, or better | Numbers | 9.00 | 21,437 | 1,92,933 |
| 27 | Installation, testing & commissioning of 24U/42U rack with 19 inch standard dimension as per instruction of Engineer in charge. It includes all the accessories for fixing of the same. | Numbers | 9.00 | 1,955 | 17,595 |
| 28 | Supply of STP (Shielded Twisted Pair) CAT-6 Cable compliant with TIA/EIA-568- B2-1 or latest. | Metre | 1220.00 | 40 | 48,800 |
| 29 | Supply of RJ-45 connector. Make: D-link or better. | Numbers | 300.00 | 6 | 1,800 |
| 30 | Supply and installation of 32 channel NVR as per specs No. 10.2 of RDSO specs No. RDSO/SPN/TC/65/2021 Version 6.0 or latest. | Numbers | 9.00 | 37,617 | 3,38,553 |
| 31 | Supply of 10 meter length 4K High speed HDMI Cable. | Numbers | 27.00 | 961 | 25,947 |
| 32 | Supply of 1G SFP module for 20 KM transmission working on single/dual fibre and should support all the software features, environmental standards and security features as mentioned in RDSO technical document no STT/TAN/IP- MPLS/2020 Ver2.0 or latest. | Numbers | 104.00 | 3,794 | 3,94,576 |
| 33 | Cement Concrete of proportion 1:3:6 (Cement: Sand: Stone chips of 25mm nominal size) for miscellaneous works. It includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). Note: All materials required for foundation are to be supplied by the contractor. | cum | 5.00 | 3,647 | 18,235 |
| 34 | Supply of 32 mm PVC casing capping in rectangular shape with separate Casing & Capping, double lock, heavy duty & ISI mark with IS:14927 or latest with minimum 1 mm thickness. | Metre | 900.00 | 47 | 42,300 |
| 35 | Supply of 25 mm (1 inch) PVC conduit pipe rigid plain ended conduit size IS:9537 (part-3) or latest and 9537 (Part- 1) 1980 with latest amendment ISI marked with minimum 1.2 mm wall thickness & minimum one socket at every 3 meter pipe. | Metre | 900.00 | 27 | 24,300 |
| 36 | Chase cutting in floor/wall and restoring of floor/wall with plaster for concealing of 50 mm./25mm conduit pipe (covered separately) in floor/wall then painting with matching colour as per existing colour of the floor/wall. | Metre | 1940.00 | 68 | 1,31,920 |
| 37 | Transportation and fixing of PVC Conduit pipe/channel/casing caping on wall or structure with drawls of Telecom/Power/Data cable with proper finishing. This includes supply of fixing materials including flexible pipe/bend etc. as required during course of execution. | Metre | 1800.00 | 15 | 27,000 |
| Schedule total | ₹1,51,40,210.6 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IRGCC April 2022
ATTACHMENT
BankMandateForm.pdf
ATTACHMENT
BankGuarantee-converted.pdf
ATTACHMENT
LCform.pdf
ATTACHMENT
EngagementofretiredRlyEmpCertificate.pdf Engagement of Retired Rly Employee
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
AnnexureVA.pdf
ATTACHMENT
DetailsofInspectionAuthority_1.pdf
ATTACHMENT
UDINinNITs.pdf
ATTACHMENT
JPOCableCut19FEB2024.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
EngagementofretiredRlyEmpCertificate.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .