GE (West) Delhi Cantt-10
GE (West) Delhi Cantt-10
Day to day maint of solar water heater, old LED fittings, internal electrification, DBs in AGE B/R-III OTM area of HQ TG EME, AFMSD, AFTC and 629 TPT Coy, CWE NO 2, GE (West), BSO Yard (West) and Ashray Mess under GE(West) Delhi Cantt-10
2026_MES_773520_1
GE/DW/TOKEN/52 OF 26-27
Open Tender
Civil Works
180 days
delhi
Class E and category a(i) or b(i)
9 documents required · 9 mandatory
₹500
GE(West) Delhi Cantt
₹50,000
Yes
23 Jul 2026
19 Jun 2026
25 Jul 2026
19 Jun 2026
23 Jul 2026
17 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and removal from site and making good the disturbed surfaces of (wall/floors/ceiling etc) complete all as specfied & directed. | 290 | Per point | - | - |
| 2M&L for point wiring with PVC FRLS insulated multistranded unsheathed cable 1.5 Sqmm size with stranded copper conductor, 1100 volts grade conforming to IS:694 drawn in an existing conduit or as per site requirement making good the surfaces as per existing surfaces with concealed sunk in pressed steel/GI terminal boxes of 1.6 mm thick factory made fixed with brass screws and cup washers including single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in an existing conduit or as per site requirement completed all as specified for the following:- | |||||
| 2.01 | One light/fan/bell/Exhaust fan/Fresh Air Fan point controlled by one way switch 5 amps. complete all as specfied & directed. | 70 | Per point | - | - |
| 2.02 | One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board. complete all as specfied & directed. | 20 | Per point | - | - |
| 2.03 | One 3 pin 5 Amps socket outlet point controlled by one way switch on same board along with other switches. complete all as specfied & directed. | 10 | Per point | - | - |
| 3 | Ditto- all as per item no. 2.02 but one power point with insulated stranded copper conductor cable 2.5 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 2.5 Sqmm stranded conductor as earth wire connected to dolly complete. Note :- Point wiring drawn in existing conduit or as per site requirement all as specified and directed. | 12 | Per point | - | - |
| 4 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 4.0 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), including PVC insulated multi stranded copper conductor 4.0 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed.(For AC point) | 8 | Per point | - | - |
| 5M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 1.5 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with modular metal flush boxes of size 1.6 mm thick including cover plate with frame of white colour of suitable size as required at site, including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed at site for the following: | |||||
| 5.01 | One light/fan/bell/Exhaust fan/Fresh Air Fan point controlled by one way switch 5 amps. complete all as specfied & directed. | 90 | Per point | - | - |
| 5.02 | One 3 pin 6 Amps socket outlet point controlled by one way switch on independent board. complete all as specfied & directed. | 40 | Per point | - | - |