Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC | ₹30.1 L Quoted ₹32.8 L | L1 | Accepted-AOC L1 bidder lowest |
| 2 | L2₹33.7 L+₹83,000 (2.53%)Rejected-Finance | ₹33.7 L+₹83,000 (2.53%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹46.5 L+₹13.7 L (41.7%)Rejected-Finance | ₹46.5 L+₹13.7 L (41.7%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹54.5 L+₹21.6 L (65.8%)Rejected-Finance | ₹54.5 L+₹21.6 L (65.8%) | L4 | Rejected-Finance Other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
24 Aug 2022, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR AND MAINTAIN OF CEILING FAN EXHAUST FAN WALL AMOUNTED FAN REPAIR/REPLACEMENT OF DBS MCBS SUBMAIN WIRING AND CERTAIN MISC WORK UNDER GE (WEST) JABALPUR
2022_MES_530044_2
8479/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹96,000
3 Sept 2022
3 Aug 2022
26 Aug 2022
3 Aug 2022
24 Aug 2022
10 Aug 2022
4 Aug 2022 - 9 Aug 2022
Amount
M&L for Rewinding of ceiling fans including opening of fan, Removing the burnt copper winding of ceiling fan after testing and cutting the rotor coil complete and making clean the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, over-hauling, lubricating with fresh grease including assembling with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete for the following .
(a). 1200mm sweep .
(b) 1400mm sweep
M&L for Rewinding of Exhaust fans including opening of fan,Removing the burnt copperwinding of ceiling fan after testing and cutting the rotor coil complete and making clean the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, over-hauling,lubricating with fresh grease including assembling with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete for the following
(a). 450mm sweep .
(b) 375/300 mm sweep
M&L for Rewinding of Tablet/Bracket fans including opening of fan, removing the burnt copper winding of ceiling fan after testing and cutting the rotor coil complete any make cleaning the rotor & the stator and rewinding with and including super enamelled copper wire of approved quality of existing gauge, over-hauling, lubricating with fresh grease including assembling with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete for 400mm sweep.Note for item No 1 to 3: Contractor shall to collect fans from AGE E/M Electric store yard & deposit the repaired fans in AGE E/M Store yard
M & L for Opening of ceiling fan of any make and any sweep for over-hauling complete including providing fresh clean lubricating Oil/ grease, reassembling for proper functioning , with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete for the following .
(a). 1200mm sweep .
(b) 1400mm sweep
M & L for Opening of Exhaust fan of any make and any sweep for over-hauling complete including providing fresh clean lubricating Oil/ grease, reassembling for proper tunning, with replacement of unserviceable parts (to be measured & paid seperately) and testing for satisfatory operation complete for the following :
(a). 450mm sweep .
(b) 375/300 mm sweep
Supply only in replacement of ball bearing of 6201/120 for ceiling fan/ exhaust fan of any size and make complete. Make : NBC, SKF, TATA
All as per Item No. 14 above but 6202/115 complete. Make : NBC, SKF, TATA
All as per Item No. 14 above but 6203/117 complete. Make : NBC, SKF, TATA
All as per Item No. 14 above but 6204/118 complete. Make : NBC, SKF, TATA
Supply only in replacement of condenser 2.5 MFD of apporved make forceiling fan complete. Make : EDcos, Scimanse, Unic
All as per Item No. 18 above but 4.0 MFD for exhaust fan complete. Make : EDcos, Scimanse, Unic
Supply & fixing in replacement of self lubricating bush of gun metal of same make for ceiling fan/exhaust fan complete.
Supply & Fixing in replacement of shaft of approved quality for ceiling fan/Exhaust fan any make and type & size complete.
S&F in replacement of split pin suitable for ceiling fan/ exhaust fan any make and type & size complete.
S&F in replacement of PVC flexible 3 core cable with copper con-ductor of size 16/0.20 mm from ceiling rose to fan including connection complete.-
M&L for painting of ceiling fan including preparing the surface of body/blades of ceiling fan of any sweep and make and painting with 2 coats of synthetic enamel white paint and writing the MES No. with black paint 2.5 cm height letters comlete.
M&L for painting of exhaust fan including preparing the surface of body/blades/frame of of exhaust fan of any sweep and make and painting with 2 coats of synthetic enamel Grey paint and writing the MES No. with black paint 2.5 cm height letters comlete.
M&L for Hanging only ceiling fan and connecting up with point wiring complete for satisfactory functioning complete with PVC flexible 3 core copper conductor cable. Note: (i) Ceiling fans for hanging in the buildings with regulator shall be issued by Engineer-in-charge on proper issue voucher & receipt voucher after repair.
S&F in repairs rubber reel suitable for ceiling fan of any make and size.
S&F in repairs GI pipe medium grade with all fitting and fixed complete for ceiling fan as down rod of 15 mm bore.
S&F in replacement GI pipe 40mm medium grade with all fitting and fixed complete for hanging of ceiling fan .
M&L in replacement for clamps and back plates fabricated from steel section conforming to Gde Fe 410-0 or Fe 310-0 includingnuts, bolts, washers, drilling holes for bolts in any shape or size for fixing ceiling fan complete weighing not more than 2Kg.
M& L for comprehensive maintenance and overhauling of ceiling fans at site of any make and size including following works (a) Checking proper working of ceiling fans. (b) Checking of safety pin/sockets/clamps including replacement of unseviceable part (c) Replacement of unserviceable condenser/bearings. (d) Cleaning of ceilingfan/overhauling with fresh grease. ( e). Note : 1.Contractor has to depute Two electricians daily who will report to JE /Fan incharge. Incase of absence of electrician without without prior permission of Engr-in-charge, Rs 500 per day penalty shall be imposed by department. 2 Unserviceable parts to be measured & paid seperately under relevant item of Sch A. 3. All T & P and ladder provide to electrician at site by contractor.
M&L for making opening by cutting/chasing existing PCC/Masonary wall for fixing of exhaust fan of 300mm/450 mm sweep capacity including grouting of foundation bolts complete plastering and making good distrubed surface good complete all as specified and directed.
Opening the UPS of any capacity and testing the online UPS after disconnecting the supply and making the arrangement for stand by supply alll as required and directed at site
Shifting the UPS upto 30 KVA from site to workshop and reshifting after repair and installed and making connection all as requirede and directed at site
S&F the battery 12 volts 6 AH maintenance free complete with connecting all as required and directed at site
S&F the cared IGBT card with fixing all as required
S&F the driver card complete
S&F control card for the ups of cap upto 30 KVA
S&F the Transformer complete for the ups of cap upto 30 KVA
Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed by Engineer-in-Charge.
S&F in repair Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire including making good disturbed surface to match existing complete all as specified & directed. Note : - Two run of 4 Sqmm & one run of 4.0 Sqmm cable shall be measured as one unit run.
S&F in repair Sub main wiring with two single core FRLSH PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 6.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Two run of 6 Sqmm & one run of 6 Sqmm cable shall be measured as one unit run.
S&F in repair Sub main wiring with two single core FRLSH PVC Insulated cable two run of size 10.0 Sqmm multi-strand copper conductor FRLSH cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 10.0 Sqmm multi-strand copper conductor FRLSH cable as continuous earth wire complete all as specified and directed. Note : - Two run of 10 Sqmm & one run of 10 Sqmm cable shall be measured as one unit run.
Material & Labour for point wiring with three layer FRLSH PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into and concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for One light Point /Fan/ Exhaust fan/ Bell point controlled by one switch..
Ditto all as per above item but for one socket point 5 Amp controlled by one switch on same board.
Ditto all as per above item but for one socket point 5 Amp controlled by one switch on Independent board.
Ditto all as per above item but for one light point controlled by two way switch.
Ditto all as per above item but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLSH cable 1100 Volts grade drawn into the existing conduits including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge for one light/ Fan / Bell Point controlled by one switch.
Ditto all as per above item but for one socket point 5 Amp controlled by one switch on same board.
Ditto all as per above item but for one socket point 5 Amp controlled by one switch on Independent board.
Ditto all as per above item but for one light point controlled by two way switch.
Ditto all as per above item but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
M&L for drawing the wire in with casing caping complete with point wiring with FRLSH PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover or inner outer plates for modular switches with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed for one light/ Fan / Bell Point controlled by one switch.
Ditto all as per above item but for one socket point 5 Amp controlled by one switch on same board.
Ditto all as per above item but for one socket point 5 Amp controlled by one switch on Independent board.
Ditto all as per above item but for one light point controlled by two way switch.
Ditto all as per above item but drawing in with casing caping point wiring using 2.5 Sqmm (Nominal area)triple layer FRLSH PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 6/16 amps on “independent board”.with 2.5 sqmm with one single run copper wire as continuous earth wire to common earth dolly complete.
S&F call bell ding dong sound type suitable for AC 230 volt single pole complete all as specified & directed. Make:Anchor/plaza/leader
S&F switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed.Make:Anchor/plaza/leader
S&F switch piano flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed.Make:Anchor/plaza/leader
S&F socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified & directed. Make:Anchor/plaza/leader
S&F Switch socket combination 2 in 1, 3 pin / 5 Amp and 15 Amps flush type universal of polycabonate body complete all as specified & directed.
S&F lamp holder / batten or angle holder Insulated body incl 9 w LED bulb with back plate suitable for batten fittings complete all as specified & directed
S&F Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified & directed.Make:Anchor/plaza/leader
S&F Ceiling Fan regulator electronic type 280 Watt capacity of polycarbonate body ISI marked complete all as specified & directed.
Supply & Fixing in repair Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification Make : Philips Cat part BN 021 LED 22S 6500 PSU GR SI / Halonix Cat part No HLB-03-24-CW-AL-SQ or equivalent Lukar/CG/Orient
S & F in repair LED Mirror light fitting 2 ft TL 5 12 watt complete with fixing arrangements on wall all as specified and directed.Make- PHILIPS Cat part no:BN 021 LED 12S 6500/4000 PSU GR SI / Halonix Cat part No HLB-03-12-CW-AL-SQ or equivalent jaquar/luker
S&F in repair decorative wall light fitting made up of Polycarbonate ,Cylindrical shape ,with LED lamp 9 Watt complete with fixing arrangements on wall all as specified and directed. Make: CITY 1 OF HAVELLS or equivalent in Bajaj/Philips/ Halonix
S&F in repair Bulk head endura LED light fitting complete 10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suitable size and accessories & length complete all as specified & directed. Make :Havells Cat Part No. RUGBYGENXFTS10WLED865SSYMBOPC/ Halonix Cat part No HLBH-02-10-CW or Equivalent make Philips / LUKER
S&F in repair LED light fitting square 57x57 CM Not less than 40 watt along with fixture Surface / Recessed /Pendent mounting LED luminaries with diffuser channel Luminaires ers, connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge. Make: Philips cat part no: RC375B LED 36S/840 PSU W60 L660 S2 WH/ Halonix Cat part No HLCR22-BO01-CW or equiv in LUKER/Havells
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make: Legrand cat no :5076 21 or eq in SEIMENS /GE/Schneider
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 4 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make : Legrand / SEIMENS /GE/ Schneider
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 12 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make: Legrand /SEIMENS /GE/Schneider
S&F in replacement sheet metal enclosure MCB DB double door [Acrylic], Triple pole and neutral, 440 volts, 4 way with 200 Amp, 10 KA breaking capacity rated copper bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make:Legrand Cat no :5077 80 or Eq in SEIMENS/GE/Schneider
S&F in replacement MCB Triple Pole and Neutral 63 Amps,415 V ,10KA breaking capacity complete all as specified & directed.Make: Legrand cat no :4086 83 or eq in SEIMENS /GE/ Schneider
S&F in replacement MCB Single Pole and Neutral 240Volt, 40 Amps,10KA breaking capacity complete all as specified & directed.Make: Legrand cat no :4086 18 or eq in SEIMENS /GE/Schneider
S&F in replacement MCB Single Pole and Neutral 240Volt, 63 Amps,10KA breaking capacity complete all as specified & directed.Make: Legrand /SEIMENS /GE /Schneider
S&F in replacement MCB Single Pole 240Volt, upto 40Amps,10KA breaking capacity complete all as specified & directed..Make: Legrand cat no :4086 90/92/93/94/95/96 or eq in SEIMENS /GE /Schneider
Supply & fix in replacement of LED Security Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint. complete all as specified and as directed.Make: Havells cat part no: ENDURASUNDOWNSL25WLED765PASYBOTGIHD / Halonix Cat part No HLSLD-09H-25-CWLR or equivalent in philips or LUKER/Wipro/ Bajaj/ Crompton
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed.Make: Legrand cat no :5078 11 or eq in SEIMENS /GE/Schneider/ Crompton
S&F switch piano type switch two way AC 230 volts 6 Amps as per on existing switch board
S&F in replacement PVC casing caping 25mm as required at site complete with fixing nails and making good the disturbed surfaces etc complete all as specified.
S&F in replacement PVC conduit 25mm medium gradeas required at site for passing through submains complete with all fittings such as tee, bends,elbow, saddle etc and making good the disturbed surfaces etc (Cutting , chasing,finishing shall be included in this Item complete all as specified.
S&F in replacement of frame plate for modular switch 3/4 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F in replacement of frame plate for modular switch 6/8 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
S&F in replacement insulation deteriorated PVC insulated flexible copper conductor cable twin twisted of Size 24/0.20mm 1100 volts grade complete all as specified and as directed.
S&F in replacement MS Housing box 3/4 module suitable for modular switch as per existing switch box and making good to the disturb surface complete all as specified and as directed.
S&F in replacement ceiling fan regulator, electronic Socket type, single phase, 230 volts complete all as specified and as directed.
S&F in replacement MS sunken box suitable for switches/ Socket/ FR as per existing site switch box and making good to the disturb surface by PCC complete all as specified and as directed.
S&F in replacement MS Housing box 5/6 module suitable for modular switch as per switch box and making good to the disturb surface by pcc complete all as specified and as directed.
S&F in replacement of modular switch 6-10 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F in replacement of modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F in replacement of modular socket, 6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed.
S&F in replacement of modular socket, 6/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed .
S&F in replacement modular fan regulator, 2 Module 4 step 180w heavy duty 230 volts as per existing model/make complete all as specified and as directed.
S&F in replacement of 3mm thick hylam sheet of any size including brass screws and washers etc as per required at site complete all as specified and as directed.
S&F in replacement modular bell push switch piano, flush type, 6 Amps complete all as specified and as directed.
S&F in repairs LED Bulb 230V AC 9/10 watt cool day light 6500K complete all as specified and directed by Engineer-in -charge. Make :- Havells/Philips/Bajaj/Wirpo/ CG /Halonix
S&F in repairs LED Bulb 230V AC 7 watt cool day light 6500K complete all as specified and directed by Engineer-in -charge. Make :- Havells/Philips/Bajaj/Wirpo/CG /Halonix
Supply & Fixing in repairs RCBO four Pole 240Volt, 63 Amp,100 MA protection for earth over load and short circuit complete all as specified & directed. Make : Legrand 411374 / Siemens / GE
S&F in replacement of single core wire 10 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed Make :- Havells/ polycab/ plaza
S&F in replacement of single core wire 6 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. Make :- Havells/ polycab/ plaza
S&F in replacement of single core wire 4 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. Make :- Havells/ polycab/ plaza
S&F in replacement of single core wire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. Make :- Havells/ polycab/ plaza
S&F in replacement of single core wire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. Make :- Havells/ polycab/ plaza
S&F in replacement of sheet steel enclouser distribution boards, double door factory made VTPN 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB 100 amps and MCB TP 63 A -02 Nos,MCB SP -04 Nos circuits comprising of 3 phase 4 wire of suitable rating all as specified and directed.Make of Distribution Board Legrand cat no:5077 50 or equivalent in seimens /GE and Make of MCBs :Legrand/Seimens/GE/ Schneider
Material & Labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete. Note:- If earth resistance of earthing is not found satisfactory it will be redone by the contractor without any extra cost to Govt.
Taking down carefully light fitting any type and re fixing the same after cleaning, reconnection using 1.5 sqmm copper conductor FRLS cable 1100 volt grade complete all as required and as directed by Engineer-in-Charge
Supply & Fixing in repairs RCBO double Pole 240Volt, 32 Amp,100 MA protection for earth over load and short circuit complete all as specified & directed. Make : Legrand 411333 / Siemens / GE
kiran electrical and hardware centre
mandeka constructions
VEENUS ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .