Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹5.4 CrAccepted-AOC | ₹5.4 Cr | L 1 | Accepted-AOC As per recommendation of Tender Committee. |
Tender Value
₹4.5 Cr
EMD Value
₹9.1 L
Closing Date
29 Jul 2019, 11:00 amClosed
Director Town and Country Planning
Office of the Director Town and Country Planning Assam Dispur Guwahati 6
Development of Vegetable Market at Tinsukia under CIDF
2019_UDD_13632_1
TP/CIDF/06/2019/190 Dtd 17/07/2019
Open Tender
Civil Works
Works
450 days
Tinsukia Assam
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
Yes
Director Town and Country Planning
₹9.1 L
Yes
Guwahati
12 Feb 2021
19 Jul 2019
29 Jul 2019
19 Jul 2019
29 Jul 2019
20 Jul 2019
25 Jul 2019
Amount
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Dismantling wood work in frames, trusses, purlins and rafters including stacking the materials as directed by the department for all levels.
Dismantling steel work in built up sections in joists, angles, channels, tees, flats etc. including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking the materials as directed by the Department for all levels
Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
Dismantling and removing the existing door and window frame (chowkath) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. (i) Area of door/window up to 3.00 m2
Earth work in excavation for foundation trenches of walls, retain -ing walls, footings of columns, steps, septic tanks etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all leads and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. ( I) Upto a depth of 2m below the existing ground level . a) In ordinary soil
Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, complete as directed and specified (measurement to be taken in the face area timbered) (b) Above 1.5 m upto 3.00 m depth
Earth/Sand filling in plinth in layers not more than 150 mm thk. including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensati -on, Forest Roalty, Sales Tax and other duties and taxes as may be necessary (I) With silt (Predominantly non plastic ) by truck carriage including loading and unloading .
Plain cement concrete work with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, steps, walls, brick work etc. as directed and specifoed including dewatering if be measured and paid separately) a) In Prop. 1 cement : 3 Sand : 6 Coarse agg. by volume
Providing and laying plain/reinforced cement concrete work with coarse sand & 20 mm down graded stone aggregate including dewatering if necessary and curing complete supply of materials but excluding cost of form work and reinfircement ( form work and rein-forcement will be measured and paid separately ) Using mixture machine
i) In sub-structure upto plinth level. I) Foundations, footings, columns with base tie and plinth beam, grade beam ,pile cap ,base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not less than 100mm thick upto plinth level. b) M 20 or Prop 1:1.5:3
ii) In super structure from plinth level. I) Foundations, footings, columns with base tie and plinth beam, grade beam ,pile cap ,base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not less than 100mm thick upto plinth level. b) M 20 or Prop 1:1.5:3
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st. floor level to 2nd. floor level.
iii) Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band. a) M15 grade concrete or Prop. 1:2:4
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st. floor level to 2nd. floor level.
Providing and laying 25 mm thick damp proof course with cement concrete in prop. 1:1.5:4 with graded stone aggregate of 10mm down nominal size including providing approved damp proff mixture in prop. as recomended by the manufacturer including curing etc. complete as directed.
Providing brick soling in foundation and under floor with stone/ best quality picked jhama bricks, sand packed and laid to level and in panels after preparing the surface as directed including all labour and materials and if necessary dewatering complete . a) Brick on flat soling
Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub structure upto plinth level.
(I) In Sub-structure upto plinth level including dewatering if necessary a) In prop 1:4
(II) In superstructure above plinth level up to 1st floor level. a) In prop 1:4
Extra over item Nos. 4.1.4 above for each subsequent floor or part thereof above the 1st floor level. a) In prop 1:4
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall a) In cement morter in proportion 1:4
Extra over item Nos. 4.1.8 above for each subsequent floor or part thereof above the 1st floor level to 2nd. floor level.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to ceiling not exceeding 4 m and removal of the same for insitu reinforced cement concrete and plain concrete work in
a) Foundation, footing, base of columns, pile cap, raft and mass concrtete works etc. I) Using 38 mm thick plank
Sides of tie beams, plinth beams, grade beams etc.at or below ground level I) Using 38 mm thick plank
Columns, pillars ,posts & strut.. a) Square, Rectangular, polygonal in plan or any shape like Tee/ L etc having plane vertical face. I) Using 38 mm thick plank
Extra for each subsequent floor or part thereof above the First Floor level to 2nd. floor level as mentioned in item no. 3.1.1.3
Sides and soffits of beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties a) For depth not exceeding 1.0M. I) Using 38 mm thick plank
Extra for each subsequent floor or part thereof above the First Floor level to 2nd. floor level as mentioned in item no. 3.1.1.4
Flat surface such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas balconies and the like. a) Floors etc. upto 200 mm in thickness I) Using 38 mm thick plank
Extra for each subsequent floor or part thereof above the First Floor level to 2nd. floor level as mentioned in item no. 3.1.1.5
Vertical ties, fins, sun breaker, louvers, bands, dropwalls etc. I) Using 38 mm thick plank
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
Extra for each subsequent floor or part thereof above the First Floor level to 2nd. floor level as mentioned in item no. 3.1.1.10
Providing form work of ordinary timber planking and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first floor level. (a) Thickness not exceeding 200mm.
Providing form work of 12mm thick Plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first floor level. (a) Thickness not exceeding 200mm.
Extra for each subsequent floor or part thereof above the First Floor level to 2nd. floor level as mentioned in item no. 3.2.3
Cement concrete works in topping 1:1:2 (1cement :1sand :2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg.of cement per sq. m. of floor to be laid in panels including curing complete as directed. (b) 20 mm thick
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side a) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. (1st Floor level to 2nd. floor level)
B) On fair side a) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. (1st Floor level to 2nd. floor level)
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) c) In cement mortar 1:5
15 mm thick plain cement mortar bands in cement mortar 1:4 in width including curing complete as directed.
A) Up to 300 mm width
a) Flush band
b) Sunk band
B) Above 300 mm width
a) Flush band
b) Sunk band
c) Raised band
Cement plaster skirting with cement mortar ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement including rounding of juctions with floor. a) 20 mm thick .
65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. VITRIFIED i)Normal range (Sizes 300 mm x 300mm and above) Somany made- Durastone (Unpolished heavy duty Vitrified Tiles) a). Premium
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (i) Normal Quality (i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)
Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (a)Normal range Somany/ Orient/Nitco /Asian Make i)Of size 300mmx300mm and above Orient made
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls) a) Normal range Somany/ Orient/Nitco/Asian Make i) Of size 200mmx200mm and above
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With sal wood
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. a) Decorative type face panel and block board core. (i) 40 mm thick
Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (b) 3 Track sliding window (i) 6mm clear glass
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii)Super Ductile (SD) TMT reinforcement bars
Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level. (1st Floor level to 2nd. floor level)
b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. .
c) ISI approved Mild steel reinforcement bar(M.S.Bar)
Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level. (1st Floor level to 2nd. floor level)
Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire lenth and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters.
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. II Ornamental grill (c) Fixed to Brickwork/P.C.C/R.C.C.
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
c) Applying one coat of distemper primer of approved brand and manufacture on wall surface after throughly brushing the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
a) Applying one coat of cement primer ( on ext. wall) of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Finishing old/ new wall with water proofing weather coat smooth anti-fungal premium textured exterior finish of Sandex Matt brand of Snowcem India Ltd. of required shade after clering and clearing the surfaces etc.including scaffolding complete as directed at all levels (two coats).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) (a)TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50 mm thick
Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50 mm thick
Providing & fixing Stainless Steel(Grade 304) Railing made of Hollow Tubes Channels,plates etc,including welding,grinding,buffing,polishing and making curvature(wherever required) and fittingthe same with necessary stainless steel,nuts & bolt complete,ie, fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc,of required size,on the top of the floor or the side of waist slab with suiteble arrengement as per approval of Engineer Incharge (For payment,only weight of steel member is to be considered.No extra payment for fixing accessories such as nuts,bolts, fasteners, etc. will be considered)
Supplying, providing, mixing and laying over waterproofing layers/ coatings with concrete screed of average 30mm thick or as per drawings/ requirements in proportion 1:2:4 (1cement : 2fine aggregate : 4coarse aggregate) (by volume) with 10mm and down well graded aggregates and admixed with a normal plasticizer like Master Plast PL-1 of Choksey Chemicals /Dr. Sealkit Normal Plast (Asian Chemicals)/Rheomac 707 of BASF @ 0.3% by weight of cement and thereafter scoring the top surface of the concrete screed @ 200mm c/c as specified and directed by the Department.
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
a) Sliding door bolts i) 300mm x 16mm
b) Tower bolts ii) 250mm x 12mm
b) Tower bolts iv) 150mm x 10mm
c) Door handles ii) 100mm
e) Butt hinge v) 100mm x 75mm x 4mm
Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 440 mm b) Coloured ii) Hindware make
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) b) Coloured ii) Hindware make (v) Water closet UNIVERSAL "P (Cat.No.20012) (inclusive of seat cover)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (a) White ii) Hindware make (iii) FB 610 x 410 x 380 (Cat. No.60002)
Supplying, fiting and fixing automatic flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) (a) White ii) Hindware make Auto Cister 10 litre (Cat. No.C61002)
Under Counter Basin (a) White ii) Hindware make (i) Lara (Cat. No.10095)
Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (b) Size 600mm x 450mm
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (A) Parryware Make (ii) Wall Soap tray (Cat. No.C9951)
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 300mm for wash basin (Cat.No. ACN-1101N)
Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified. (a) Jaquar make (ii) Continental toilet paper holder with flap (Cat.No. ACN-1153N)
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (a) Jaquar make (i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia
b) Concealed by chiselling or breaking brick wall/ C.C./ R.C.C and making good to the damages. (ii) 110mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia
b) Concealed by chiselling or breaking brick wall/ C.C./ R.C.C and making good to the damages. (ii) 110mm dia
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia
b) Concealed by chiselling or breaking brick wall/ C.C./ R.C.C and making good to the damages. (ii) 110mm dia
Supplying fiting and fixing PVC plain single tee of (Supreme /Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.. a) In exposed surfaces or in trenches. (ii) 110mm dia
b) Concealed by chiselling or breaking brick wall/ C.C./ R.C.C and making good to the damages. (ii) 110mm dia
Providing fitting and fixing 100 mm dia PVC Cowel with ISI make complete as directed and specified.
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. b) 100 mm dia
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified.
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified.
(A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)
a) 50 mm dia
b) 40 mm dia
c) 32 mm dia
(B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)
d) 25 mm dia
e) 20 mm dia
f) 15 mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) II) Jaquar make a) Continental/ Clarion I) Standard
Supplying fitting and fixing Chrome plated (C.P.) stop -cock of approved brand and size as mentioned below as directed and specified ( G.I. & C.P. pipes will be measured and paid separately) II) Jaquar make a) Continental/ Clarion (ii) 15 mm dia ( Angular stop cock)
Supplying and fitting fixing C.P. pillar cock of 15 mm dia of approved brand as specified and directed. II) Jaquar make (b)Long neck with areator
Supplying and fitting fixing C.P. pillar cock of 15 mm dia of approved brand as specified and directed. II) Jaquar make (b)Long neck with areator
Supplying and fitting gun metal country pit valve ( full way valve) I.S.I Make as specified and directed
b) 40 mm dia
Supplying fitting and fixing gun metal check valve include necessary threads to pipes
b) 40 mm dia( Heavy Type)
Labour for sinking tube well with 40 mm ( internal) dia G.I. Pipes up to strata, having potable water including fitting and fixing strainer , hand pump and other accessories as directed complete as in any soil
Supplying, fitting and fixing suction pipes ( plain/ bevel ended) , conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casting pipes complete as directed ( I) G.I. Pipe (a) TATA/SAIL (medium)( sockets should be welded to the pipes) iii) 40 mm diameter
Supplying fitting and fixing brass Tez filter 2.00 meter long.
Supplying fitting and fixing check valve ( non return valve ) including threads to pipes c) 40 mm dia
Supplying, fitting and fixing Maya Hand pump No 6 for 40 mm dia tube well with all accessories complete as directed
Flushing , clearing, washing and watering of the tube well
Supplying fitting and placing plastic cylindrical vertical closed top ( PCVC) tank of Sintex/ Polycon/ Patton make over the stagging with manhole cover with locking arrangement and cleaning arrangement including providing pads of sizes as required for inlet and outlet piped complete as directed with labour charge
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete
b)Medium point upto 6.00mtr length
c)Long point upto 10.00mtr length
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. b)Medium point upto 6.00mtr length
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Extra long point up to 25.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 6 way TPN (4+18) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 63A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 100A
Supplying including fitting and fixing of high speed AC Ceiling fan complete with all accessories like , down rod, canopy etc.of following sweeps with making necessary connection etc.as reqd complete and directed by the deptt.(Without regulator) a) 1400mm sweep
Installation ,testing and commissioning of ceiling fan including the regulator, down rod of standard size(up to 300mm length) and connection etc complete as specified and directed by the department.
Supplying including fitting fixing of AC Exhaust fan in the existing hole on the wall of following sweeps and making necessary connection etc.as reqd complete ans as directed by the deptt. b) Heavy duty 450MM sweep 900 RPM Single phase (Orient make)
Supplying and fixing Call bell(Buzer) including 5 Amps capacity flush type bell push switch including connections as approved by the Deptt as required
Supplying fitting and fixing of single wall brackets model 37712 (or equivalent as approved by the Deptt.) on the wall in GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover with all accessories including connection as required complete. Without lamp.
Supplying including installation, connection as approved by the Deptt., testing and commissioning of JET MONOBLOCK PUMP SET complete as directed and specified by the deptt. 2 HP single Phase jet monoblock pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 120.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25x4 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid Copper tube having 85 mm dia. single prong at top and 3 mm thick base plate at bottom complete with fitting & fixing with Brass nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
Supply, installation, testing & commissioning of Air cooled Ceiling Suspended Duct able Split type Air conditioners of following capacities suitable for refrigerant R22/R407C with outdoor unit consisting of hermetically sealed imported power efficient Scroll compressors, condenser coil and condenser fan and indoor unit consisting of evaporating coil, blower fan, motor & filter. Both cooling coil & condenser coil will be made up of copper-internally grooved with slit fins, anti corrosion blue fins along. The control system shall be microprocessor bases with following safety inbuilt: HP/LP cut-out, SPPR (protection against single phasing & reverse polarity) In-built thermal/temperature protection. Microprocessor controller is provided with following features: Auto switch on or off of compressors memory back up of settings Auto restart after power failure Runtime equalisation of the compressors Built-in time delay to protect compressors Fault diagnostics to facility speedy correction The cost of the machines will also include 20G hard drawn copper refrigerant piping properly saddles using wall spacers CPVC condensate drain piping including U Trap properly saddled, ( Fire Retardant Canvas Cloth duct connection as approved by the Deptt., ( Electrical interconnection between IDU & ODU using ISI marked cables in 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit properly saddled, ( Nitrogen pressure testing of refrigerant circuit, ( Refrigerant Gas Charging ensuring optimum performance, etc complete in all respects "make)s Approved Bluestar, Voltas, Carrier, Hitachi, Daikin, Mitsubishi. 5.5 Tr
Supplying including installation, testing and commissioning of Solar power plant as per following specification and as directed by the Department. 1.92 KWp STANDALONE SOLAR POWER PLANT Load: 1000 Watts for 4 Hrs/Day Back up Or, Load: 500 Watts for 8 Hrs/Day Back up Crystalline Solar PV Module - TBP1280M/ TBP1280 with RDSO Part-I Approval (as per IRS S: 84/92 or latest Amdt.) & IEC: 61215 Certification. 24 nos Crystalline Solar PV Module - TBP1280M/ TBP1280 with RDSO Part-I Approval (as per IRS S: 84/92 or latest Amdt.) & IEC: 61215 Certification. 24 nos 2 4 Module mounting structure with theft proof frame 6 nos 3 Array Junction Box (AJ 2 nos 4 Main Junction Box (MJ 1 no 5 Power Conditioning Unit (PCU) – 48V DC- 2KVA- 230V AC, 50Hz 1 no 6 Battery Bank-Tubular Plate LMLA Battery Bank of 48V, 300Ah @ C10 1 set 7 2C X 2.5 Sq.mm. P.V.C Cu.cable 100 metres 8 2C X 6.0 Sq.mm. P.V.C Cu.cable 50 metres 9 2C X 10 Sq.mm. P.V.C Cu.cable 30 metres 10 1C X 25 Sq.mm. P.V.C Cu.cable 20 metres 11 Earthing kit 6 nos 12 Installation kit 1 set Note: All cable lengths are estimated. Extra cables, if any, shall be charged extra at actual. All cable Lengths are calculated from the Solar Array to input of the Power Conditioning Unit (PCU). Loads & Load cables are not included in the Bill of Materials. SUGGESTED UNIT PRICE
Unit Cost Without Installation & Commissioning)
Installation & Commissioning Charges
Supplying and installation and commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m ×1.00 m ×0.50 m made of 16 SWG1.66mm) thick CR sheet and 35 mm × 35 mm × 6 mm size angle and 35 mm ×6 mm flat iron having 4 nos legs at the bottom and G.I. Sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coats of enameled paint. The panel board is to be erected in 1:3:6 RCC pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items. 1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer - 1 no 2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos 3. 25 mm × 5 mm size 4 strip copper Bus-Bar- 1 set 4. 40 Amp 4 pole ON-OFF poser contactor - 1 No. 5. Surface mounting timer switch - 1 No. 6. 63 Amp bakelite HBC fuse kit-kat - 3 Nos 7. 0-40 Amp electro-mechanical counter display 3 Phase 4 wire electronic hybrid energy meter
Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding of the pole shaft. The welding of the pole shaft shall be done by Submerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make)Pole Type BOP or equivalent-7030 Height 7m The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO , Base Plate Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections :- The Octagonal Poles shall be in single piece with single longitudinal welding join, Galvanization :- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening :- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia. (A/ 70mm Bottom Dia. (A/ 130mm , Sheet Thickness 3mm , Base Plate dimensions :- (L x B x 220 x 220 x 12, Foundation Bolt , Bolt Size :- (no. x dia.) 4 x 20 Dia, Pitch Circle Dia. (PC 205 Bolt Length 750, Projected Bolt Length 100mm, Anchor plate thickness:- 4 mm , Pole Foundation :- The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation:- The foundation shall be done with ( Earth work:- 2.04 cubic Meters.RCC :- 1:1.5 : 3 proportion 0.65 cubic metres. Steel :- 22.43 Kg. Shuttering :- 4.32 square metres. = 22.43 Kg.
Supplying with fitting & fixing of the following integral type street light luminaries complete and consisting of single piece integral epoxy gray powder coated dia cast aluminium housing gasket, pot optic reflector, cast aluminium frame from heat resistance toughened clear glass cover and accessories such as Condenser, lamp Holder, Ballast, lamp etc. in the existing pole including making necessary connection as approved by the Deptt.)with 2× 2.50 sq.mm F.R. multistrand and P.V.C. insulated single core copper cable as specified and directed by the department. Philips make) Cat No.SRX086 1xSON150W For Lamp 1xSON/SONT150W/ / Havells make): LHYW00115099 For lamp 1x150W SON-T.
Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries. Header with top cap 300 mm long pipe of thickness 3 with arrangement to fix on pole top with 3 Nos. of bolts. i Armed of required length size 48.3mm out side dia x 3.25mm thick (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) Stiffener plate from arm of the following types : Single arm bracket 1000mm long for 3m to 10 metre. Poles.
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 315 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department.
Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised channel of 75 mm x 40 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department.
Supplying and erection of 11 KV Pin insulator (Poly) with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
Supplying including installation of 4' dia. C.I. earth pipe complete as required and as directed by the department.
Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying and erection of 11 KV Disc insulator (Poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
Supplying & laying of 8 SWG Copper earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
MS Bolt & nuts
HT Stay set erection with boulder packing
Supplying and fitting fixing of galvanised L.T. T cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supply including fitting and fixing of Resin Cast type outdoor end cable Termination Kit for 3 Core/1.1 KV PILC cable (MS - SE For the following sizes including testing and commissioning as specified and directed by the Deptt. 50.00,70.00 & 95.00 Sq.mm., 3 Core cable.
Supply including fitting and fixing of Resin Cast type outdoor end cable Termination Kit for 3 Core/1.1 KV XLPE cable for the following sizes including testing and commissioning as specified and directed by the Deptt. 50.00,70.00 & 95.00 Sq.mm., 3 Core cable.
ASEB LOAD SECURITY
Construction of Sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts & leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 (including compensation of earth ). (Including cost of testing of materials at site and laboratory as directed by the deptt.)
(a) from Private Land .
(c) Extra lead beyond initial lead of 3.OO Km(23-3=20,20X8.46=169.20)
Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause 401 of MoRTH specifications (with an initial lead of 5 km) (including cost of testing of materials at site and laboratory as directed by the deptt.) (B)Using Grading II material
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate,watering and compacting to the reqd. density ( with an initial lead of 5.0 km. ) (A) By Manual Means (ii) 'Grading- II (a)Using Screening Crushable type such as Moorum or Gravel
Loading and unloading by mechanical means (Placing tipper at loading point, loading with front end loader, dumping, turning for return trip, excluding time for haulage and return trip) 'B) Stone aggregates
Providing and laying Interlocking Concrete Block Pavement (ICBP) conforming to IS:15658-2006 including all lead and lift complete as per technical specification and as directed. 80mm thick interlocking precast blocks having compressive strength of 40N/sq.mm.
Preparing of site for placement of drilling rig including excavation of mud pit, circulation drain,collection chamber etc.all complete as directed
Movement of rig to drilling site including cost of P.O.L .all complete as directed.
Transportation of ancilary equipment,camp materials,welding set,rig accessories etc. including cost of POL all complete as directed (b) Beyond 100.00m
Transportation of all store materials like pipe strainer, cone,socket,clamp,bentonite etc. including cost of POL all complete as directed (b) Beyond 100.00m
Transportation of air compressior of Kirloskar make 540 CFM ,10.5 kg./sq cm.with all accessories including the cost of P.O.L all complete as directed. (b) Beyond 100.00m
Transportation of P.O.L all complete as directed
Construction of temporary accomodation and low cost sanitary facility for drilling staff including cost of camp materials viz.cot,table, chairs, umbrellas,dresses, safety halmets etc. and dismentling the accomodation after completion the work all complete as directed
Providing water suplly facilities at drilling all complete as directed. (a) By installing 1N0. of Singur Hand Pump.
Boring in soft soil/normal clay/sandy soil by bit of size either 5 5/8" or 6 7/8" or 7 7/8" and collecting sample of soil at every 3.0m depth or wherever there is a change of strata in sample boxes with the distinguishing marks including arranging and carriage of necessary boring materials /tools etc. and withdrawing the drill pipe for lowering well assembly etc. all complete as directed.
Extraction of drilling pipe/ bits against screen friction at the end of each day and after completion of the operation including washing of the bore hole all complete as directed.
Lowering/ sinking of well assembly including of pipe joints for 100 mm dia. G.I./M.S. casing pipe ,strainer all complete asdirected.
Developing of DTW with air compressor,make Kirloskar/Cumins all complete asdirected.
Supplying and packing pea gravel around the periphery of casing including screening, washing etc. all complete as directed.
Supplying fitting and fixing MS Clamp of sizes 15mm thick and 150 mm wide having projection of 300 mm and three holes of 20mm dia for clamping the plates by 16mm dia hexagon bolts of length 75mm and nuts on both sides encircling the column pipe for 150 mm dia including painting.
Salwood wooden block of size 150mmx150mmx1.2m for supporting of MS Clamp
GI end plug of size 150mm dia of approved brand
Supply of UPVC end cap 160mm dia
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 2 HP STAGE 6 to 30 with MCB controlled Submersible motor pump set control panel.
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe) x) 160mm (ID) diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed A ) G.I. Pipe a) TATA/SAIL (Medium) socket should be weded to the pipes vi) 100 mm diameter
Supplying fitting and fixing brass Tez filter 2.00 metre long.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .