Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹33.8 L+₹1.7 L (5.26%)Rejected-Finance BORBHETA JAIL ROAD NEW CHRISTIAN PATTY JAIL ROAD JORHAT ASSAM 785001 | JORHAT | ASSAM | 785001 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹33.9 L+₹1.9 L (5.82%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹34.8 L+₹2.7 L (8.37%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
10 Apr 2023, 6:00 pmClosed
GE (AF) JORHAT
GE (AF) JORHAT PIN-785005
REPAIR/ MAINT AND SERVICING OF TRANSFORMER, VCB, HT SWITCH GEARS, PROTECTION SYSTEM AND CONNECTED ALLIED WORKS AT VARIOUS LOCATIONS AT AFH AND LT PANELS, CABLES AND CONNECTED ITEMS FOR PUMP HOUSES 5, 6, 8 AND 10 UNDER GE (AF) JORHAT
2023_MES_585667_1
8527/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (AF) JORHAT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹60,000
Yes
20 Jun 2023
14 Mar 2023
12 Apr 2023
14 Mar 2023
10 Apr 2023
27 Mar 2023
Amount
M&L for dismantling of unserviceable air breaker (switch) and supply new air break switch, gang operated for 11 KV grade, triple pole vertically mounted on 09 insulator and fitted on steel frame , current rating 400 Amps, mechanically operated mechanism from ground level consisting of operating rod of GI pipe 25mm bore ‘light grade’ of suitable length worked from ground level and with locking arrangement mild steel flat iron clamp 50x6mm including drop out type fuses, dismantling old unserviceable switch air break of any description, complete all as specified and as directed.
S&F as in replacement HT lightning arrester expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable, for working pressure 11000 Volts including dismantling of old unserviceable and connection to earth with GI strip 32x6mm complete all as specified and as directed.
S&F as in replacement HT expulsion fuse, single pole, channel type/drop out type suitable as per Site requirement with working pressure 11 KV grade of capacity 50 to 100 Amps including taking down unserviceable fuses complete all as specified and as directed.
S&F as in replacement HT disc type insulator porcelain, vitreous,145mm high and 255mm dia ball and socket type white, brown or green insulator single disc assembly with tension clamps for working pressure 11000 Volts complete all as specified and as directed.
S&F HT loop type insulator vitreous white, brown or green, large size with overall dimensions 90x140mm, clearance of hole 25.50mm dia complete all as specified and as directed.
S&F in replacement aluminium conductor steel reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc., fixing on electric poles and binding to insulators with aluminium Binding wire as in OH conductors including stringing, tightening, etc., complete all as specified and as directed. Note : Cost of binding wire is deemed to be included in the quoted unit rate.
S&F in replacement pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia suitable for working pressure 11 KV complete all as specified and as directed.
M&L for servicing , overhauling greasing, replacing mini parts i.e. lugs, male / female contacts, dropout fuse assembly , nuts, bolts, washers, of suitable sizes and re-fixing as per the original position of Air Break Gang Operated Switches HT 11 KV, 3 Phase, any capacity ( 200/400 ) Amps vertical / horizontal mounted including Insulators and operating mechanism. Note :- (a) Parts needed to be replaced shall be measured and paid separately. (b) Any minor repairs involved to make the GOD functional even if notified by Engineer-in-charge shall be carried out by the contractor without any extra cost to the department.
Supply only male contact/ moving contact blade suitable for air break gang operated switches, 11KV complete all as specified and as directed.
Supply only female contact/ fix contact jaw suitable for air break gang operated switches, 11KV, complete all as specified and as directed.
Supply only tinned copper flexible jumper 200/400 amps, suitable for air break gang operated switches, 11KV complete all as specified and as directed.
Supply only MS jumper carrier, suitable for air break gang operated switches, 11KV, complete all as specified and as directed
Supply only back connector plate, suitable for air break gang operated switches, 11KV complete all as specified and as directed
Dismantling cross-arms of mild steel channel or angle sections, etc of any size, including mild steel bolts, nuts, washers, etc complete all as specified and as directed
M&L for cross-arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated/ directed and inclusive of two coats of aluminium paint over a coat primer complete all as specified and as directed
M&F for painting to steel tubular pole 8.5 to 11m long with two coats of synthetic enamel paint up to 1.50m height from ground level in 30cm alternative black and yellow strips and remaining portion with aluminium paint including numbering of pole no by stencil and MS frames like channel, clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified and directed.
M&L for painting of HT feeder pillar any size after cleaning the body surface by rubbing with emery Paper to remove rust, dust etc and applying two coats of synthetic enamel paint internally and externally, including numbering, indication of feeder Volt etc complete all as specified and as directed.
M&L for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanise iron strip 32 x 6 mm as earthing lead means of nuts, bolts and washers made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to test point or as directed including Pit in plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC Cover of size 450X450X50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, galvanised Iron wire mesh, funnel, galvanised Iron watering pipe 20mm bore medium grade, including necessary excavation in soft/ loose soil, returning, filling in and removal of surplus soil upto a distance of 50.00 mtr and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on completion, including taking down old unserviceable earthing complete all as specified and as directed.
M&L for earthing with copper plate electrode 600mm x 600mm x 3.15mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip 20 x 3 mm as earthing lead means of nuts, bolts and washers made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to test point or as directed including Pit in plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) and RCC Cover of size 450x450x50mm in RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, galvanised Iron wire mesh, funnel, galvanised Iron watering pipe 20mm bore medium grade, including necessary excavation and earth work in soft/ loose soil, returning, filling in and removal of surplus soil upto a distance of 50m and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing on completion, including taking down old unserviceable earthing complete all as specified and as directed.
S&F as in repairs 32mm x 6mm galvanized iron strip as earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etccomplete all as specified and directed..
S&F as in repairs 20mm x 3mm copper strip as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and as directed.
S&F as in repairs cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sq.mm complete all as specified and as directed.
S&F as in replacement of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sq.mm complete all as specified and as directed.
S&F as in replacement of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sq.mm to 185sq.mm complete all as specified and as directed.
S&F as in replacement of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sq.mm to 185sq.mm complete all as specified and as directed.
S&F as in replacement of cable jointing kit for 11KV(Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95sq.mm and testing complete all as specified and as directed.
S&F as in repairs cable jointing kit for 11KV(Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sq.mm to 185sq.mm and testing complete all as specified and as directed.
S&F galvanised iron pipe 80mm bore ‘light grade’ for protection of UG cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc. after taking down old unserviceable pipe complete all as specified and as directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying HDPE pipe of 150mm dia suitable for 0.4 Mpa working pressure complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation for pole etc complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20 mm graded aggregate) as in coping for pole including form work and finishing the surfaces even and smooth, etc complete all as specified and as directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size after taking down old/ damaged danger notice plate complete all as specified and as directed.
Supply, laying, testing and connecting cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade of size 3 core 95sq.mm ( earth grade) ISI marked with valid CML No complete all as specified and as directed.
Supply, laying, testing and connecting cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade of size 3.5 core 500sq.mm ( earth grade) ISI marked with valid CML No complete all as specified and as directed.
Supply, laying, testing and connecting cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade of size 3.5 core 400sq.mm ( earth grade) ISI marked with valid CML No complete all as specified and as directed.
Supply, laying, testing and connecting cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade of size 3.5 core 185sq.mm ( earth grade) ISI marked with valid CML No complete all as specified and as directed.
M&L for re-laying and re-routing of serviceable HT/LT UG cable of any size and any type of cable up to 120 sqmm , 3 core & 3.5 core size including brass compression cable gland, terminal lug, etc. complete all as specified and as directed. Note : Excavation, sand, bricks and connected items shall measured and paid separately.
Excavation in trenches not exc. 1.50m wide and not exc. 1.50m in depth and getting out in soft / loose soil complete all as specified and as directed.
Excavation in trenches not exc. 1.50m wide and beyond 1.50m in depth and getting out in soft / loose soil complete all as specified and as directed.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of payment, punning thickness of sand cushioning shall only be measured and paid.
S&F sub-class 'B' brick, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated materials not exc. 50m and depositing where directed at a level not exc. 1.50m above the starting point complete all as specified and as directed.
Re-laying only old brick in trenches for under ground cable over the sand cushioning for cable protection (serviceable bricks obtained from Item here-in-before) complete all as specified and as directed.
Disconnecting and taking out existing 11 KV HT VCBs of any make from housing and cleaning, rubbing and overhauling the mechanical parts and Servicing of 11 KV in door VCB, checking of quality of vacuum interrupter, insulation resistances, static contact resistance, Testing ( IR value, Ratio test, Polarity test) and connection verification of 6.6 KV Current transformer( Set of three) by PRIMARY INJECTION KIT ,and Testing and calibration of relay (set of two Over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. setting right the mechanism and reassembling, testing and commissioning etc as required complete all as specified and directed.
(a) Taking out trolley unit from metal clad housing and dismantling complete, carrying out inspection cleaning, mechanical spring complete all as specified and directed. (b) Opening of bus bar chambers, carrying out inspection, cleaning of complete unit and refixing of the bus bar complete all as specified and directed. (c) Carrying out testing of all metering instruments replacement of worn out spares, meter, wiring cable etc and testing complete. (d) Inspection and checking of all protection devices, relays, complete all as specified and directed. (e) Carrying out inspection and testing of auxiliary power system, complete all as specified and directed. (f) Assembling of complete HT switch gear unit, proper greasing oiling / for easy operation and connection of incoming and outgoing cable and make all necessary adjustment and testing complete all as specified and directed.
Note : Replacement of spares such as Gasket set, ht trolley bushes, plug insulators, busbar insulator for HT VCB , PT Bush for HT VCB, PT housing bush for HT VCB, interrupter of HT VCB HT HBC fuse link IDMTL relay, power pack 230 V/110 V DC 20A and CT ratio 100-50/5A etc shall be paid separately under relevant item here-in-before
Supply only of CT ratio 100-50/5-5A. 15 VA, class 1 accuracy for metering and protection resin cast current transformer as per existing make complete all as specified and directed. Make : ECS/Pragati/JSL/Gemini /Schneider/L&T
Supply only breaker control cam switch for 11KV VCB as per existing make complete all as specified and as directed Make : ECS/Pragati/JSL/Gemini /Schneider/L&T
Supply only indicating lamp LED type as per sample suitable for existing VCB indicating lamp complete all as specified and as directed
Supply only HT 11KV PT in VCB as per existing make complete all as specified and as directed Make : ECS/Pragati/JSL/Gemini /Schneider/L&T
Supply only HRC fuse link of capacity 12A, BCNA 3-15/B1, 11 KV breaker PT high voltage complete all as specified and as directed.
Supply only 3 phase earth fault and over current digital type control relay of HT 11 KV VCB including connecting and setting up of parameters / calibration/ testing as per the site conditions complete all as specified and as directed. Make : ECS/Pragati/JSL/Gemini /Schneider/L&T
Supply only digital voltmeter for measurement of voltage of HT 11 KV VCB as per existing make complete all as specified and as directed. Make : AE/Rishav/Elmeasure/Secure/L&T
Supply only digital ammeter for measurement of current of HT 11 KV VCB as per existing make complete all as specified and as directed. Make : AE/Rishav/Elmeasure/Secure/L&T
Supply only spring charge motor including gear asembally for 11 KV VCB as per existing make complete all as specified and as directed. Make : ECS/Pragati/JSL/Gemini /Schneider/L&T
Supply only 11 KV Vacuum Interrupter with TC suitable for 11 KV VCB Panel as per existing make complete all as specified and directed. Make : Schneider Model VG2 / ABB / Siemens
Supply only multifunction meter square type digital of size 96Sq.mm of capacity 0 to 15 KV PT ratio 11 KV/110 volt for panel complete all as specified and as directed Make : AE/Rishav/Elmeasure/Secure/L&T/Conzerv
Dehydration/filtration of transformer oil by means of centrifugal filtration plant to achieve the specified di-electric strength of 35 KV to 40 KV at 2.5mm gap in existing position of transformer of any capacity and transformer oil for topping up at various sub-station complete all as specified and as directed. Note : Transformer oil to be used for top up shall be measured and paid separately.
Supply & pouring of new transformer oil, conforming to IS:335-1983 to achieve a di-electric strength upto 60 KV with oil testing Kit 4.0mm thick to top up of the transformer complete all as specified and directed.
Disconnecting HV/LV Connections of Transformer, including disconnecting of earthing lead, unscrewing nuts, bolts and washers, testing their un-serviceability (Open and Closed circuit test) with the help of composite unit of Transformer 100 to 630 KVA 11000/433, and isolation transformer of any capacity complete all as specified and as directed.
M&L for servicing , testing of transformer of 100 to 630 KVA , 11000/433 volt indoor/outdoor, disconnecting all Internal connections of HT/LT side for periodical maintenance such as cleaning of core and winding by means of washing by hosing down with clean dry oil to removed dust/sludge on core and coil, cleaning of oil tank to removed sludge deposited, replacement of rusted gasket set, burnt spindle, broken/ unserviceable HV/LV ceramic bushing, broken arc horn, surge arrestor, replacement of silica gel, etc. and then after assembling to all complete all as specified and directed. Note : (a) Cost of transformer oil for cleaning by hosing down shall deem to be included in the quoted unit rate. (b) Replacement of spares parts will paid separately.
Supply only breather assembly filled with silica gel for transformer of 100 to 630 KVA , 11000/433 volt indoor/outdoor as approved complete all as specified and as directed.
Supply only brass spindle for terminal on HT side threaded complete with nut, washers, etc. of dia as ordered, as approved and suitable for transformer 100 to 630KVA 11000/433 volt, complete all as specified and as directed.
Supply only brass spindle for terminal on LT side threaded complete with nut, washers, etc. of dia as ordered, as approved and suitable for transformer 100 to 630KVA 11000/433 volt, complete all as specified and as directed.
Supply only ceramic bushing and gasket on LT side of transformer 100 KVA to 630KVA 11000/433 volt complete all as specified and as directed. Make : MYSORE POTTERIES/BHELL or equivalent model from make as approved by GE.
Supply only ceramic bushing and gasket on HT side of transformer 100 KVA to 630KVA 11000/433 volt complete all as specified and as directed. Make : MYSORE POTTERIES/BHELL or equivalent model from make as approved by GE.
Supply only gasket (cock sheet) 6mm thick with conical rubber bush complete as approved and suitable for transformer 100KVA to 630 KVA 11000/433 Volt including taking down/ out unserviceable gasket complete all as specified and directed.
M&L for apply one coat of synthetic enamel paint by spray painting including preparation of body of transformer 100KVA & 630 KVA 11000/433 and writing SM No./MES No., capacity of transformer complete all as specified and as directed.
S&F in replacement 75mm dia HDPE pipe, PN-10 for cable protection on pole/wall/floor or in trenches and drain /culvert etc. complete with necessary clamp, nuts, bolts, washers, sockets complete all as specified and as directed.
Taking down / out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, etc. of any descriptions, laid in trenches and /or fixing with walls /poles including segregating of serviceable materials viz bricks, cables, etc. and kept in Safe custody for re-use, complete all as specified and directed. (NOTE : Earth Work shall be measured and paid separately under relevant Items here-in-before.)
S&F in replacement silica gel grains in breather assembally of transformer complete all as specified and directed.
S&F in replacement On load changeover switch with sheet steel enclosure of capacity 630 amps, 415 volts AC 4 pole suitable for wall mounting complete all as specified and as directed. Make : L&T, Cat No. CO46300OSOO or its equivalent model from make Havells / Legrand / ABB.
Supply, installation, testing and commissioning as in repairs of Indoor type, floor mounted, totally enclosed LT panel board of size 1.80m (H) x 1.80m (W) x 0.60m (D) with suitable compartmentalized design, dust & vermin proof suitable for 440 Volts, 3 phase, 4 wire system made out of 2.0 mm thick CRCA MS sheet and built upon rigid frame work having front hinged doors with neoprene rubber gasket including danger plate, earthing strip point and ventilation louvers at both sides, detachable gland plate at bottom complete with suitable size of zinc/chromium plated nuts, bolts and washers, having 04 No’s extended aluminium bus bars, for termination of incoming and outgoing cables, duly mounted on DMC/FRP insulators and fabricated in a CPRI approved factory having modern fabrication and testing facility which included eight (08) tank pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 micron) with approved shade of RAL 7032 and shall be with IP-43 grade protection. The panel shall be grouted with 50 x 6mm thick mild steel angle iron frame and control wiring shall be with colour coded solid copper conductor 1.5sq.mm cable for easy identification and comprising of the following accessories :-
BUS BAR :- (i) Electrolytic aluminium bus bar, 400 Amps capacity, supported with suitable size of heavy duty PVC stand lock with suitable size of brass nuts, bolts & washer with heat shrinkable PVC sleeving, duly colour coded (red, yellow & blue) for three phases & black for neutral – 04 Nos. INCOMING :- (i) MCCB, 3 pole, 415 Volts, 160 Amps, breaking capacity 36 KA, adjustable thermal magnetic release - 01 No Make : Legrand, Cat No: 420047 / L&T, Cat No: CM92109OON1OG or its equivalent model from make ABB / C&S / Schneider
OUTGOING :- (i) MCCB, 3 pole, 415 Volts, 100 Amps, breaking capacity 25 KA, adjustable thermal magnetic release - 03 No Make : Legrand, Cat No: 4200 03 / L&T, Cat No: CM90642OOL0 or equivalent model from make ABB / C&S / Schneider (ii) MCB, TPN, 415 Volts, 40-100 Amps, breaking capacity 10 KA, C series - 04 No (iii) DOL starter for Air compressor/Blower to be mounted inside panel board duly flushed to facilitate operations with push button with over load relay and single phase protection feature - 04 No’s Make : L&T, Cat No: SS94362 or its equivalent model from make Havells / Indo asian / HPL / C&S / BCH ) (iv) Star delta starter suitable for centrifugal/Submersible pump for 20 HP set - 03 No’s
Taking out unserviceable/burnt starter including electrical connection, supply & fixing fully star delta starter (18-22 Amps relay range) suitable for centrifugal pump sets up to 15 HP, 415 volt, 3 phase in the LT panel board with suitable size of copper lugs/wire complete all as specified and as directed.
Taking out unserviceable/burnt starter including electrical connection, supply & fixing fully star delta starter (20-25 Amps relay range) suitable for centrifugal pump sets up to 20 HP, 415 volt, 3 phase in the LT panel board with suitable size of copper lugs/wire complete all as specified and as directed.
Taking out unserviceable/brunt contactor including electrical connection, supply & fixing power contactor ML 2 type 415 volt, 3 phase suitable for star delta starter in the LT panel board with suitable size of copper wire complete all as specified and as directed.
Taking out unserviceable/brunt contactor, supply & fixing power contactor ML 3 type 415 volt, 3 phase suitable for star delta starter in the LT panel board with suitable size of copper wire complete all as specified and as directed.
Taking out unserviceable/brunt contactor including electrical connection, supply & fixing power contactor MNX 18 type 415 volt, 3 phase suitable for star delta starter in the LT panel board with suitable size of copper wire complete all as specified and as directed.
Taking out unserviceable burnt relay, supply & fixing bimetal overload relay, relay range 20-32 Amps/ 28-42 Amps, 415 volt, 3 phase suitable for star delta starter in the LT panel board with suitable size of copper wire complete all as specified and as directed.
Taking out unserviceable/defective push button unit, supply & fixing push button unit for star delta starter complete all as specified and as directed.
Taking out unserviceable burnt single phase preventer, supply & fixing single phase preventer with accessories suitable for motor 12.5-20HP capacity with necessary electrical connection by using proper size of single core copper wire complete all as specified and as directed. Make : Minilec, Cat No. VSP1 AST or its equivalent model from make L&T / Siemens.
Taking out unserviceable/brunt voltmeter, supply & fixing Digital voltmeter 0-600volt rage of size 4x4", 3 phase, 415 volt suitable for the LT panel board with suitable size of copper wire complete all as specified and as directed. Make : L&T / AE / HPL
Taking out unserviceable/brunt ammeter, supply & fixing digital Ammeter 0-150 Amps of size 4x4", capacity ,3 phase, 415 volt, suitable for the LT panel board including electrical connection with suitable size of copper wire complete all as specified and as directed. Make : L&T / AE / HPL
Taking out unserviceable/brunt indicator assy. supply and fixing Indicator LED assembly 3 pcs per set suitable for 230 volt matching with existing one for the LT Panel board where directed including taking out old U/S indicator assembly including electrical connection with suitable size of copper wire complete all as specified and as directed.
Taking out unserviceable/brunt MCCB, supply & fixing MCCB 160 Amp, 415 volt, 36kA, 3 pole suitable for 415 volt matching with existing one for the LT panel board with suitable size of copper Lugs/wire complete all as specified and as directed.
Taking out unserviceable/brunt MCCB, supply & fixing MCCB 125 Amp, 415 volt, 16kA, 3 pole suitable for 415 volt matching with existing one for the LT panel board with suitable size of copper Lugs/wire complete all as specified and as directed.
Taking out unserviceable/brunt MCCB, supply & fixing MCCB 63-100 Amp, 415 volt, 16kA, 3 pole suitable for 415 volt matching with existing one for the LT panel board with suitable size of copper Lugs/wire complete all as specified and as directed.
Taking out unserviceable/brunt MCB ,supply & fixing MCB TPN 40-100 Amp, 415 volt, 10 KA C series suitable for 415 volt matching with existing one for the LT Panel board with suitable size of copper Lugs/wire complete all as specified and as directed.
Taking out unserviceable/brunt wire, supply & fixing single core PVC insulated unsheathed multi stranded 1100 volt grade FRLS copper cable of size 10 Sq.mm for electrical connection from starter to electric motor cutting into pieces as required length and making connection by using suitable size of copper lugs on both ends complete all as specified and as directed. Make : Payal/ Plaza/ Havells or Equiv
M&L for preparation of steel external surface of LT panel board of average size 2x1.5x.6 (approx.) Installed at various E/M installations for spray painting on external surface on old painted surfaces by using one coat of synthetic enamelled paint of approved colour after cleaning properly the external surface including cutting the detonated portion/ fabrication works to LT panel board including making good the disturbed surface complete all as specified and as directed.
All as per serial Item No. 20 here-in-after but of size 0.75X0.5X0.45mm LT FEEDER PILLAR BOX located at Various Pump Houses and Sewage Pump Installation.
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 95 sq.mm 3 core complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 20mm graded stone aggregate) as in fixing the pipe, cutting the road / hard standing and making good distrubed surfaces complete all as specified and as directed.
S&F galvanised iron pipe 50mm bore ‘light grade’ for protection of UG cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc. complete all as specified and as directed.
S&F as in repairs changer over switch (SS Enclosure) complete with of capacity 125 Amp, 415 Volt, 4 pole, 50 HZ complete all as specified and as directed. Make : Havells, Cat No IHCNFE0400 or its equivalent model from make Legrand/L&T/ABB
S&F connecting up testing and commissioning security light fittings 60W LED type complete with standard fittings/accessories (as applicable to the fitting) including provision and fixing by 40mm bore light grade galvanised iron pipe 1.5m long bend to shape and 40mmx6mm thick mild steel flat irons clamps, nuts bolts and connecting up from ceiling rose by means of 3 run of 1.5 sq.mm PVC insulated unsheathed weather proofing, multi stranded copper conductor cable including taking down old unserviceable fitting a bracket from OH tank complete all as specified and as directed.
S&F connecting up testing and commissioning LED Aviation obstruction light comprising of aluminium housing with polycarbonate enclosure, 302 no’s clear thick glass and accessories complete with standard fittings/accessories (as applicable to the fitting) including provision and fixing on over head tank at various pump house connecting up from ceiling rose by means of 3 run of 1.5 sq.mm PVC insulated unsheathed weather proofing, multi stranded copper conductor cable including taking down old unserviceable fitting from OH tank complete all as specified and directed. Note:- The contract sum shall be calculated by deducting the amount shown in schedule of credit attached to this tender, from total amount of Schedule 'A'/BOQ
ANIL RAI AND COMPANY
M/S SANTOSHI TRADERS
satyabhama and co
Bidder Name
satyabhama and co
M D Constructions Co
M/S SANTOSHI TRADERS
ANIL RAI AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .