Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹39.2 LSame as L1Rejected-Finance 1308 MAIN ROAD BABINACANTT DIST JHANSI 284 401 | BABINA | JHANSI | UTTAR PRADESH | 284401 | L2 | Rejected-Finance Please refer
para 3.17 on
page No 48 of
Manual on Contracts 2007 (Reprint 2012) | |
| 3 | L3₹39.3 L+₹4,969.40 (0.13%)Rejected-Finance VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L3 | Rejected-Finance Not being a
lowest
tender | |
| 4 | L4₹41.4 L+₹2.2 L (5.53%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | BABINA | JHANSI | UTTAR PRADESH | 284401 | L4 | Rejected-Finance Not being a
lowest
tender | |
| 5 | L5₹43.6 L+₹4.4 L (11.1%)Rejected-Finance | L5 | Rejected-Finance Not being a
lowest
tender |
Tender Value
Refer Docs
EMD Value
₹96,900
Closing Date
19 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BABINA
GE BABINA CANTT 284401
OUT SOURCING OF SERVICES FOR MAINT AND OPERATION OF MAIN RECEIVING SUBSTATION , TKD AND BUNDELA CAMP ELECTRIC SUPPLY INSTALLATIONS AND CONNECTED REPAIR WORKS UNDER GE BABINA
2020_MES_397201_1
GE/BAB/TOKEN /58 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
330 days
GE BABINA
AS PER TENDER DOCUMETNS
8 documents required · 8 mandatory
₹500
GE BABINA
₹96,900
Yes
31 Dec 2020
21 Nov 2020
21 Dec 2020
21 Nov 2020
19 Dec 2020
5 Dec 2020
60 days
Amount
(PART-A) In case quoted amount of part-A are less than minimum wages including statutory provisions mentioned here in below the tender will be treated as NON BONAFIDE and will not be considered for acceptance.
Manning and operation of MES electric installations/ receiving cum distribution 33 KV Sub Station by deploying of 01 electrician ( Skilled Electrician ) in 3 continuous shift of 08 hours each { One electrician in each shift of 08 hours (Total No of electrician = 03 Nos for one day)} including Sundays & holidays for successfully running/ functioning of complete HT/LT installations etc at 33 KV MRS power house consisting of following electrical equipments complete all as specified and directed. Power house consisting of the followings :- (a) Power transformer step down 33KV/11KV ,capacity 5 MVA and 2 MVA each including marshal boxes complete- 2Nos (b) Out door type 33 KV grdae VCB with control panels - 2 Nos (c) HT VCB Incomer 11 KV -2 Nos (d) HT VCB Bus coupler 11 KV - 01 No (e) HT VCB Out going -16 Nos ( f) Control panel 33 KV -02 No (g) On load remote tap charger panel for 20 MVA transformer (h) Battery charger with battery bank 30 volts DC - 03 Nos & 110 volts DC-1 No (j) Out door type transformer step down ,11 KV /433 volts , capacity -200 KVA - 02 Nos (k) All other accessories of 33 KV tard and 11 KV yard like overhead line conductor, jumpers , lightening arrestor , shunt capicitor bank ,earthing HT/LT UG cables insulator ,Kiosk terminal boxes PT/CT etc complete (l) Capicitor bank complete with control panel VCB -11 KV -01 Set (m) Battery charger with battery bank for 11 KV VCBs (n) Stand by DG set 200 KVA -01 No Note : (i) 1st shift from 0600 hrs to 1400 hrs one electrician. (ii) 2nd shift from 1401 hrs to 2200 hrs one electrician. (iii) 3rd shift from 2201 hrs to 0600 hrs one electrician.
Manning and operation of MES electric installations/ receiving cum distribution 11 KV Sub Station at location of Tankodrome area by deploying of 01 electrician ( Skilled Electrician ) in 3 continuous shift of 08 hours each { One electrician in each shift of 08 hours (Total No of electrician = 03 Nos for one day)} including Sundays & holidays for successfully running/ functioning of complete HT/LT installations etc complete all as specified and directed. Note : (i) 1st shift from 0600 hrs to 1400 hrs one electrician. (ii) 2nd shift from 1401 hrs to 2200 hrs one electrician. (iii) 3rd shift from 2201 hrs to 0600 hrs one electrician.
Manning and operation of MES electric installations/ receiving cum distribution 11 KV Sub Station at location SAF Camp Budela area by deploying of 01 electrician ( Skilled Electrician ) in 3 continuous shift of 08 hours each { One electrician in each shift of 08 hours (Total No of electrician = 03 Nos for one day)} including Sundays & holidays for successfully running/ functioning of complete HT/LT installations etc complete all as specified and directed. Note : (i) 1st shift from 0600 hrs to 1400 hrs one electrician. (ii) 2nd shift from 1401 hrs to 2200 hrs one electrician. (iii) 3rd shift from 2201 hrs to 0600 hrs one electrician.
Manning and operation of MES electric installations/ receiving cum distribution 11 KV Sub Station at location of new FAD area by deploying of 01 electrician ( Skilled Electrician ) in 3 continuous shift of 08 hours each { One electrician in each shift of 08 hours (Total No of electrician = 03 Nos for one day)} including Sundays & holidays for successfully running/ functioning of complete HT/LT installations etc complete all as specified and directed. Note : (i) 1st shift from 0600 hrs to 1400 hrs one electrician. (ii) 2nd shift from 1401 hrs to 2200 hrs one electrician. (iii) 3rd shift from 2201 hrs to 0600 hrs one electrician.
Rate required to be quoted for execution of the work as described in 2 to 5 here-in-before for the following :-
01 Skilled Electrician (Per shift) wages as per Minimum wages as per as latest notification issued by Government of India/ State Government/ Local body whichever is higher as on bid submission end date.
ESI (Insurance cover) @ 3.25% on minimum wage. If monthly minimum wages are exceeding Rupees twenty one thousand (Rs 21,000/-), ESI shall be exempted on minimum wages at Ser No 6.02.
EPF (Employee provident found) @ 13.00% on minimum wage. If monthly minimum wage are exceeding Rupees fifteen thousand (Rs 15,000/-). EPF shall be calculated for amount Rupees fifteen thousand (Rs 15,000/-) only on minimum wages at Ser No 6.02.
Contribution of bonus @ 8.33% on minimum wage at Ser No 6.02.
Over head & Contractor's profit.
Labour cess @ 1% on totoal amount of Ser No 6.02 to 6.06.
GST @ 18% on total amount of Ser No 6.02 to 6.07.
(Part-B)
S&F in replacement kiosk box for luminaires ,weather proof made out of PVC/HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of copper bus bar 4 nos of 16 Amps with 6 Amp MCB single pole , of minimum size 300x200x125mm, IP 66 fixed on pole with MS, clamps 30x5mm with necessary nuts, washer and incl. applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed. The quoted rate also includes cost for material & repalcement of 4 sqmm multistranded twincore aluminium cable ISI marked from overhead conductor to junction box and replacement of 3 core copper cable of 1.5 Sqmm ISI marked from junction box to security light length as per required at site.
S&F of cable jointing Kit 11 KV (earthed) grade cable for indoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 to 120 sqmm complete all as specified and as directed.
S&F of cable jointing Kit 11 KV (earthed) grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed.
S&F of cable jointing Kit 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and as directed.
Description all as per item no 12 of here above but of size 120 sqmm 3 core
Description all as per item no 12 of here above but of size 185 sqmm 3 core
S & F in replacement of vacuum interrupter , suitable for 11 KV HT V.C.B 11 KV 630 /800 Amps capacity cat No. 520/SP of Make CG or equvalent in C&S/Areva/L&T .
S & F in replacement fixed contact block of V.C.B 11 KV 630/800 Amps capacity cat No. 522/SP Make CG or equvalent in C&S/Areva .
S & F in replacement moving contact block of V.C.B 11 KV 630 /800 Amps capacity cat No. 524/SP Make CG /L&T
S & F in replacement motor & gear assembly 220 Volt AC motorised mechanism of V.C.B 11 KV 630/800 Amps capacity including testing & puting on load cat No. 537/SP Make CG/C&S/Areva .
S & F in replacement closing coil assembly 24/ 110 volts DC for HTV.C.B 11 KV 630/800 Amps capacity cat No. 594/SP Make CG /C&S/Areva/L&T
S & F in replacement tripping coil assembly 24 / 110 volts DC for HT V.C.B 11 KV 630/800 Amps capacity cat No. 599/SP Make CG /C&S/Areva/L&T .
S & F in replacement of Post insulator with hardware fittings 33 KV Grade make :- BHEL/JAYSHREE/ABB/PACTIL.
S & F in replacement of Disc insulators with hardware fittings 33 KV Grade Make:-BHEL/JAYSHREE/ABB/PACTIL.
S & F in replacement auxillary switch (6 No + 6NC) for HT V.C.B 11 KV 630/800 Amps capacity cat No. 562/SP Make CG/L&T/C&S
M & L for disconnecting & taking out old/defective Current Transformer from 11 KV VCB panel, S & F installation & testing of Current transformer, indoor, comprising of 3 Nos single phase resin cast CTs of 300-150 / 5+5 Amps ratio, PS class, dual core with suitable VA burden and accuracy suitable for protection & metering incl making suitable arrangement for fixing in existing VCB panel and connection complete all as specified and directed. Make :- L&T /Crompton/ABB/C&S
M & L for disconnecting & taking out old/defective PT from 11 KV VCB panel, S & F installation & testing of PT, indoor, comprising of 3 Nos single phase resin cast PTs of 11KV/110 Voltage ratio, 50 Hz PS class, with suitable VA burden and accuracy suitable for protection & metering incl making suitable arrangement for fixing in existing VCB panel and connection complete all as specified and directed. Make :- L&T /Crompton/ABB/C&S
S & F in replacement of 11 KV Silicon polymeric composite Disc insulator B&S type incl galvanised mild steel strap 38 mm X 5 mm, insulator bolts 20 mm dia with suitable washers and nut, suitable for working pressure upto 12 KV as per IS 731/1971 or latest amendment complete all as specified and directed Make :- BHEL/JAYSHREE/AREVA/ABB/PACTIL.
S & F in replacement of 11 kv silicon polymeric pin insulator, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut,11000 volt grade suitable for working pressure 12 KV as per IS 731/1971 or latest amendment complete all as specified and directed . Make :- BHEL/JAYSHREE/AREVA/ABB/PACTIL.
S & F in replacement of ACB with microprocessor release 4 pole, LT 415 Volts, 50 Hz AC grade of 630 Amps rating 50 KA rupturing capacity with over current and short circuit release conforming to IEC: 60947-2/IS : 13947-2 fixed type (U power) in the existing panel with suitable connecting copper terminals at site complete all specified and directed. Make :- C&S/Havells/L&T
M/S RAJ KUMAR SINGH
M/S Kharya Associates
m/s gupta trading
M/s Ravi Traders
Bal Singh and Sons
DIAMOND ELECTRICALS
anand enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .