Loading…
Loading…
Tender Value
₹1.7 Cr
EMD Value
₹2.3 L
Closing Date
28 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Above/Below/Par
ELECT GEN
15 conditions · 4 needing a document upload
Only those firms which in their individual capacity, satisfy Standard Financial Criteria(s) need to quote for this tender. :The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-15, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. The tenderers shall submit Certificates to this effect which may be an attested Certificate from the concerned department / client and/or Audited Balance Sheet duly certified by the Chartered Accountant etc.
The tenderers must submit the copy of valid Electrical contractor license along with their offer. Offer shall be rejected summarily, if tenderer does not have valid Electrical contractor license on the name of an individual / Proprietor / Partner / firm issued by the State / Central government.
As a proof of Technical Eligibility, the Tenderer(s) have to submit details (Technical Eligibility) as per Annexure-13 Tender Document, indicating that Contractor have completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Format of completion certificate to be produced is provided as annexure-18 of tender docuemnts. Work experience certificate from private individual shall not be considered. However, in addition to work experience certificate issued by any Govt. Organization, work experience certificate issue by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated /registered at least 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of Similar Work: Similar work is defined as under: "Wiring, Rewiring in Buildings with associated electrical works or Lighting arrangement in buildings, circulating area, yard streets etc with associated electrical works or Wiring/ Rewiring, Lighting arrangement in buildings with associated electrical works."
30 conditions · 7 needing a document upload
GSTIN number: Bidder shall submit attested or self attested copy of GSTIN certificate.
Following documents shall be submitted by the tenderer: (A)SOLE PROPRIETOR SHIP FIRM: (i)All other documents in terms of clause 1.1.12 of tender document . (B)HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii)All other documents in terms of clause 1.1.12 of tender document. (C)PARTNERSHIP FIRM:(i)A notarised copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii)A notarised or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm.(iii)An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract.(iv)All other documents in terms of clause 1.1.12 of tender document . (D)JOINT VENTURE (JV): APPLICABLE ONLY FOR WORKS COSTING MORE THAN Rs.10.00 Cr. Not applicable for this tender. (E)Company registered under Companies Act- 2013:(i)The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company.(ii)A copy of Certificate of Incorporation.(iii)A copy of Authorization / Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iv)All other documents in terms of clause 1.1.12 of tender document. (F)LLP (Limited Liability Partnership) Firm under LLP Act-2008: (i)A copy of LLP Agreement.(ii)A copy of Certificate of Incorporation.(iii)A copy of Power of Attorney / Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP.(iv)An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (G)Registered Society & Registered Trust: The tenderer shall submit: (i)A copy of the Certificate of Registration.(ii)A copy of Memorandum of Association of Society/Trust Deed.(iii)A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust.(iv)A copy of Rules & Regulations of the Society.(v)All other documents in terms of clause 1.1.12 of tender document .
The tenderer shall submit a copy of certificate (Annexure 19(A)) in case of other than Company/Proprietary firm by each member of a Partnership Firm / Joint Venture (JV) / Hindu Undivided Family (HUF / Limited Liability Partnership (LLP) etc, as the case may be. Non submission of above certificate(s) by the bidder shall result in summarily rejection of his/their bid. It shall be mandatory incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document. Note:- As per railway board letter No. 2022/CE-I/CT/GCC Correspondence Dated: 14.05.2024 "On IREPS Module, a facility has already been created for online submission of Annexure-V. Therefore, the provision of downloading of Annexure-V of GCC & uploading of physically signed Annexure-V by the tenderer had been discontinued on IREPS".
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Payment of Bid-security in respect of E- tendering will be deposited either in cash through e payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure-VIA of GCC Works 2022 and shall be valid for a period of 90 days beyond the bid validity period and any offer without the same will be treated as invalid. Details of bank account no. and technical details have been provided for in the software (IREPS) to which prospective registered tenderers will have access at the time of tendering.
In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: (i) A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. (ii) The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document before closing date for submission of bids (i.e. excluding the last date of submission of bids). (iii) Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. (iv)The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. (v)The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected. (vi)The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right-hand top corner of the envelope. (vii)The envelope shall be addressed to the officer and address as mentioned in the tender document. (viii) If the envelope is not sealed and marked as instructed above, the Authority assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder.
PAN CERTIFICATE : PAN The tenderer shall submit the photocopy of Permanent Account Number (PAN) issued by Income Tax authority attested by Gazetted officer / self attested.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Any typographical error shall not be construed to be benefit of the contractor; in such cases the interpretation and decision of Sr. DEE/G/JAT shall be final and binding upon the tenderer.
The tenderer shall study the Northern Railway General Conditions of Contract Regulations for Tenders & Contracts - 2022 or latest along with tender documents before submission of the tender.
Applicable charges/recoveries/Advance etc. (Deployment of Technical supervisors per attached Annexure XIII) is applicable.
There is an option of payment to contractor through a letter of credit (LC) arrangement (Authority Railway Board's letter no. 2018/CE-I/CT/9 dated 04.06.2018) as given in clause 1.3.14 of tender document.
GCC works 2022(or latest if any) should be the integral part of this tender.
Electrical Work in c/w Repair, improvement & special Maintenance of Electrical Assets for proposed GM Inspection for the section PTK - MCTM under Jammu Division.
251-J-Elect-T-22-2025-26~NR
251-J-Elect-T-22-2025-26
Open
Works - General
6 Months
Jammu, Jammu And Kashmir
₹0
₹2.3 L
28 Jan 2026
6 Jan 2026
14 Jan 2026
171 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,67,88,865.51 | ||
| — | 718.00 | — | — | ||
| Supply of paint and painting of Rail/Tubular poles and brackets with superior quality aluminium paint after scrubbing the old paint on top and green enamel at the bottom of the poles upto 1.5 Mtrs height from ground level. The poles should be painted in two coats of paint. | — | — | — | 77,544 | |
| — | 389.00 | — | — | ||
| Supply of paint and painting of Service poles including clamps and brackets with superior quality aluminium paint after scrubbing the old paint. The poles should be painted with two coats of paint. | — | — | — | 24,324.17 | |
| — | 536.00 | — | — | ||
| Construction of foundation, muffing of Rail/Tubular poles with cement concrete ratio 1:2:4 duly plastered and white washed. The size of the muff should be one ft in dia and 2 ft in height at various locations in the zone. | — | — | — | 1,73,358.48 | |
| — | 670.00 | — | — | ||
| Supply, fixing, testing and commissioning of pole mounted junction box made of SMC base and door having lockable cover with 2x15 Amps kit kat fuse/6A DB MCB with 3 way neutral links for incoming and outgoing cables etc as per technical specification and site conditions, ISS/IE rules. Similar to be approved by Railway representative. The box shall have cable termination for loop in/loop out for 4 core 16/25 sq.mm cable. Make: Sintex model No. GS-JB 2014 or similar. This work includes connection with wire of suitable size an MS conduit pipe for fixing of junction box including earthing. | — | — | — | 4,16,096.8 | |
| — | 119.00 | — | — | ||
| Earthing arrangement by providing earth electrode of GI pipe 50 mm dia (B class) 4.5 meter long with flange including 6 SWG GI earth wire from earth pipe to connecting point on switch board to distribution board/pole etc. as per site requirement including masonry enclosure as per Tech specification at annexure 'A' relevant ISS & IE rules and site requirements. A suitable CI/MS/RCC cover as approved by Rly. Representative, cover with locking arrangement shall be provided. | — | — | — | 2,61,988.02 | |
| — | 1690.00 | — | — | ||
| Supply & recessing/fixing on surface 6 SWG GI wire for loop earthing as required as mentioned in explanatory note. | — | — | — | 16,933.8 | |
| — | 4955.00 | — | — | ||
| Supply of paint and painting of various electrical equipments viz; small panels, water cooler cages, switch boards and fire hose cabinets etc after scrubbing the old paint. | — | — | — | 64,266.35 | |
| — | 48.00 | — | — | ||
| Design, manufacturing of floor mounted MS feeder post made of MS sheet 16 SWG Die pressed of size 550mm x 450mm x 275mm deep complete with 400A Aluminium bus bars four Nos. having cable glands 2 Nos. duly grouted with cement concrete ratio 1:2:4 duly earthed with earthing terminals. | — | — | — | 1,73,062.56 | |
| — | 450.00 | — | — | ||
| Supply and erection of 45 W LED Street light fitting operating voltage single phase 230 volts AC, 50Hz complete with all accessories as per CEE/NR Specification No.CEE/NR/121 Elect/PS/2018 (Rev '3') Dated 28.06.2018 & CEE/NR/121-Elect/PS/2019 (Rev.4) dated 04.11.2019 or latest, including connection with 2x2.5 sq.mm PVC insulated multi stranded FRLS copper conductor cable, testing, commissioning & earthing required as per specification | — | — | — | 15,32,511 | |
| — | 4200.00 | — | — | ||
| Supply and recessing/fixing of 25mm (Medium) PVC conduit pipe conforming to IS 9537/Pt.III/1983 or Latest Version with accessories, junction box, etc including making chase, plastering/clamping etc as per technical specifications. | — | — | — | 1,62,120 | |
| — | 4000.00 | — | — | ||
| Wiring for sub-main with 2x2.5 Sq.mm FRLS PVC insulated multistranded copper conductor s/core cable in the recessed PVC conduit pipe 25 mm dia as required at site. | — | — | — | 1,42,280 | |
| — | 2100.00 | — | — | ||
| Wiring for sub-main with 2x4.0 Sq.mm FRLS PVC insulated multistranded copper conductor s/core cable in the recessed PVC conduit pipe 25 mm dia as required at site. | — | — | — | 80,661 | |
| — | 10600.00 | — | — | ||
| Wiring for light points with supply and laying of FRLS PVC insulated multistranded copper conductor cable 1100 Volt 1x1.5 Sq.mm multi stranded confirming to IS-694 latest in the existing PVC pipe. | — | — | — | 1,49,990 | |
| — | 362.00 | — | — | ||
| Design, Manufacture, supply, fixing, testing and commissioning of double sided LED type signages at platforms of suitable size as CEE/NR specification No. CEE/NR/121-Elect/PS/2018 (Rev'3') Dated 28.06.2018 or latest. and as per site requirement. Note:- Static/Double sided board of different sizes name is required. prior approval of message color and size to be taken from competent authority. | — | — | — | 6,01,419.56 | |
| — | 796.00 | — | — | ||
| Design, Manufacture, supply, fixing, testing and commissioning of single sided LED type signages at platforms of suitable size as CEE/NR specification No. CEE/NR/121-Elect/PS/2018 (Rev'3') Dated 28.06.2018 or latest. and as per site requirement. Note:- Static/single sided board of different sizes name is required. prior approval of message color and size to be taken from competent authority. | — | — | — | 11,44,990.28 | |
| — | 60.00 | — | — | ||
| Provision of cutting & removing of all type pole including dismantling of foundation & pole to be deposited in SSE/P store. | — | — | — | 42,106.8 | |
| — | 246.00 | — | — | ||
| Wiring for 5 pin 5 Amps plug points 5 Amps capacity with 2x1.5 sq.mm FRLS PVC insulated unsheathed multistranded copper conductor s/core cable in recessed PVC conduit pipe 25 mm dia including provision of 3 pin 5 Amps socket outlet with 5 Amps piano type switches and earthing of 3rd pin and MS box with insulated wire as required at site. | — | — | — | 22,818.96 | |
| — | 70.00 | — | — | ||
| Wiring for 3 pin 15 Amps plug points 15 Amps capacity with 2x2.5 sq.mm FRLS PVC insulated unsheathed multistranded copper conductor s/core cable in recessed PVC conduit pipe 25 mm dia including provision of 3 pin 15 Amps socket outlet with 15 Amps piano type switches and earthing of 3rd pin and MS box with insulated wire as required at site | — | — | — | 12,081.3 | |
| — | 21.00 | — | — | ||
| Design, manufacturing, supply, installation, testing and commissioning of wall mounted electric control panel for 15 to 25 HP for operation of submersible pumps complete in all respects as per technical specifications. | — | — | — | 6,76,020.87 | |
| — | 100.00 | — | — | ||
| Supply of 100x100x60 mm deep M.S switch box conforming to IS 5133 ( Part - I ) - 1969(latest version) with white Phenolic laminated sheet cover of approved make on front of box with brass screws & cup washers, recessing as per Tech. Specification including earthing. | — | — | — | 4,934 | |
| — | 100.00 | — | — | ||
| Supply of 180x100x60 mm deep M.S switch box conforming to IS 5133 ( Part - I ) - 1969(latest version) with white Phenolic laminated sheet cover of approved make on front of box with brass screws & cup washers, recessing as per Tech. Specification including earthing. | — | — | — | 7,272 | |
| — | 20.00 | — | — | ||
| Supply of 300x200x100 mm deep M.S switch box conforming to IS 5133 ( Part - I ) - 1969(latest version) with white Phenolic laminated sheet cover of approved make on front of box with brass screws & cup washers, recessing as per Tech. Specification including earthing. | — | — | — | 3,577 | |
| — | 50.00 | — | — | ||
| Supply of Single Phase Propeller Type Ventilating An(Exhaust Fan) Excise Duty --No. Of poles 4 Sweep Size- 380 Mm(15 Inch) Rpm- 1400, Model No. Hd Ef 380/15 Inch Of Make Action Air Or Similar Of Havells/Cg | — | — | — | 1,43,624 | |
| — | 50.00 | — | — | ||
| Installation, connection with twin core PVC insulated flexible cable 14/0.0076 inch testing and commissioning of 12"/ 15"/ 18"sweep A.C. Exhaust Fan including earthing of fan. Note: Exhaust Fan in packed condition will be supplied by the Railway from the store of SSE/P/ | — | — | — | 4,686.5 | |
| — | 3800.00 | — | — | ||
| Transportation, Laying, underground/road/Railway track, recessing in platform /wall along with Rly. Track/in laid RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured, aluminium conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specification including end terminations with Aluminium Clamping socket/lugs, testing and commissioning of Above 25 sq.mm | — | — | — | 2,25,454 | |
| — | 4600.00 | — | — | ||
| Transportation, Laying, underground/road/Railway track, recessing in platform /wall along with Rly. Track/in laid RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured, aluminium conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specification including end terminations with Aluminium Clamping socket/lugs, testing and commissioning of Upto 25 sq.mm | — | — | — | 2,62,660 | |
| — | 6000.00 | — | — | ||
| Supply & erection of 103 mm Inner dia Double Walled Corrugated pipe in ground under Railway track/road as required and as per explanatory note. | — | — | — | 20,77,260 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing and commissioning of GI pipe 50 mm dia B class ISI marked under road/ clamping with erected pole or wall as per technical specifications and drawing for passing cable. | — | — | — | 47,108 | |
| — | 23.00 | — | — | ||
| Supply, installation and commissioning of 1400 VA sinewave inverter with following features of make SUKAM, Luminous or Microteck (or similar) with supply of tubular plate 150 AH batteries of make Exide model IT500 or similar. The complete inverter unit with batteries should be housed in MS /Plastic portable trolley duly paint finished. (i) Input DC voltage 24 Volt DC (ii) Input AC Voltage 135-275 Volt (iii) Output voltage 220 Volt + 8% (iv) Output Waveform Sinewave (v) Output 1400 VA or above (vi) LED display Main ON, Inverter ON, Low Battery, Main ON, Inverter ON, Low Battery, Over Charge, Mains Low and High Input Voltage (vii) Protections: Over Load, Short Circuit, Low Battery Over Charge Mains Low and High Input Voltage. | — | — | — | 9,72,945.54 | |
| — | 10.00 | — | — | ||
| Replacement of 4 POLE 415 V MCCB for LT panel of capacity 200-250 Amps/35 KA with variable adjustment (Test report of all MCCB must be submitted) as per IS/IEC 60947-2 | — | — | — | 1,44,833.3 | |
| — | 15.00 | — | — | ||
| Replacement of 4 POLE 415 V MCCB for LT panel of capacity 100-125 Amps/35 KA with variable adjustment (Test report of all MCCB must be submitted) as per IS/IEC 60947-2 | — | — | — | 1,31,479.95 | |
| — | 4.00 | — | — | ||
| Replacement of 4 POLE 415 V MCCB for LT pannel of capacity 63 Amps/35 KA with variable adjustment (Test report of all MCCB must be submitted) as per IS/IEC 60947-2 | — | — | — | 34,950.16 | |
| — | 1160.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED tube light system wattage 18 Watt to 20 Watt complete with all mounting arrangement & accessories & flexible copper wire for connection from ceiling rose as per ISS/IR rules & site requirement as per CEE/N.Rly. Specification No.CEE/NR/121-Elect/PS/2018 (Rev '3') Dated 28.06.2018. & CEE/NR/121-Elect/PS/2019(Rev-04) dt 04.11.2019 with correction dt.10.02.2020 or latest. | — | — | — | 6,46,874 | |
| — | 25.00 | — | — | ||
| SITC of 35 Ltrs. water heater geyser BEE 5 star rating 2KW glass coated heating element , CFC free high density PUF insulation , inner tank extreme hard water resistance , suitable for high rise building & pressure pump , suitable for 230V 50Hz AC supply Make: Havells model - Monza EC or equivalent model as Racold model Eterno 2 or make AO Smith model HSE-vas-035L or similar model. | — | — | — | 2,01,286.75 | |
| — | 1.00 | — | — | ||
| Supply fixing & commissioning of Automatic Change Over Panel Capacity 150 Amp. For 25 KVA AT as per Latest RDSO Specification No. TI / SPC / PSI / CLS / 0020 With A & C Slip 01 to 04. | — | — | — | 1,30,000 | |
| — | 15.00 | — | — | ||
| Supply, installation and commissioning of light weight wall mounted voltage stabilizer confirming to IS: 8448 suitable with toroidal care transformer having capacity 4 KVA, Input Voltage 135-290V and output voltage 220-240 V, MCB 32 Amps, time delay relay (2-4 min) with soft touch type instant and start switch, under voltage and over voltage cut off with indicators, Digital Voltmeter and Ammeter with soft type selector switch for measuring input & output voltage, indicator for power ON and timer ON. IS 8448 Latest version/Make Microtek, V-Guard or equivalent with RDSO/ISO/BIS/equivalent certification | — | — | — | 88,943.4 | |
| — | 9.00 | — | — | ||
| Installation, Testing & Commissioning of Window AC , complete in all respect as per site requirement. | — | — | — | 7,645.32 | |
| — | 24.00 | — | — | ||
| Supply, fixing, testing and commissioning of surface mounted / flush type 25 Amp power unit complete with modular plate, MCB, starter, plug & socket for AC of make Wipro North West (Model - ACPU6MBT/ ACPU6M-FT) or equivalent as per IS & IE rules. | — | — | — | 14,078.16 | |
| — | 75.00 | — | — | ||
| Supply, installation, testing and commissioning of 150 Watt LED based flood light fitting, operating voltage single phase 230V AC, 50Hz complete with led lamp & all mounting arrangement, accessories & flexible copper wire for connection as per ISS/IR rules & as per CEE/NR Specification No. CEE/NR/121 Elect/PS/2018 (Rev.03) dated 28.06.2018 & CEE/NR/121-Elect/PS /2019 (Rev.4) dated 04.11.2019 respectively or latest | — | — | — | 9,60,709.5 | |
| — | 11.00 | — | — | ||
| Supply fixing testing commissioning of AT Panel for 10 KVA Auxiliary transformer for interlocking of L-Xing gate for color light signaling as per RDSO specification no.ETI/PSI//035-02 or latest | — | — | — | 5,18,410.2 | |
| — | 15.00 | — | — | ||
| Supply and fixing of rain proof MS box of suitable size of housing MCCB with hinged and lockable door on AT mast with suitable MS clamp should be painted and powdered coated: MCCB 63 Amp,3Pole | — | — | — | 51,044.55 | |
| — | 13.00 | — | — | ||
| Supply, replacement, testing & commissioning of controller PCB for Auto changeover panels of capacity 60A/150A including control wiring, buzzer remote and buzzer output, repairing of contractor, replacement of defective indication /MCB etc. As per site requirement and satisfaction to the railway representative. | — | — | — | 1,83,641.25 | |
| — | 15.00 | — | — | ||
| Supply, erection, testing and commissioning of the following Double door wall mounted Pre-fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; (i) Incoming MCB 40 A DP 10 KA B/C - 1 No. (ii) Outgoing MCB 6 to 32 A. SP 10 KA B/C - 4 Nos. | — | — | — | 21,784.8 | |
| — | 9.00 | — | — | ||
| Supply, fixing, testing and commissioning of 11KV 200Amp Gang operated switch to be provided on erected 'H' pole structure complete with GI operating handle with locking arrangements, insulators, droop out type fuses and all other accessories as per relevant specification & explanitory notes | — | — | — | 2,96,430.93 | |
| — | 8.00 | — | — | ||
| Supply, fixing and testing of non-linear resistance, distribution type lightning arrester, suitable to work on AC, three phase, 11KV, 50 Hz system of capacity 9 KV and 5 KA ,conforming to IS No:3070 part-I (1993). The lightning arrester shall be fixed with suitable GI clamps using GI bolts of adequate sizes with nuts and washers. The earth terminals shall be effectively earthed using GI wire / flat of appropriate size as required at site. (Note:One set comprises of 3No's).11KV. | — | — | — | 33,469.12 | |
| — | 25.00 | — | — | ||
| Supply and stringing of stay wire sets complete with stay rods 8 feet long with GI base plate 150x150x60 mm thick duly grouted with cement concrete ratio 1:2:4 including provision of stay clamps made of MS flat 50x8 mm complete with nuts and bolts and washer duly galvanized etc | — | — | — | 26,757.5 | |
| — | 80.00 | — | — | ||
| Replacement of defective indication lamp by LED type indication lamp,30 5mm 240 Volts AC to red, Yellow & Blue Colour) Note Above item are to be fixed on LT panel/Feeder Pillar try addition/alternation in panel as per ISME rules and site requirement. | — | — | — | 8,671.2 | |
| — | 25.00 | — | — | ||
| Supply, fixing, connection, testing commissioning of Ammeter Selector Switch 4 position at 90 degree, with one OFF position, 16 amps, 440 Volts AC, panel mounted type, make Kaycee. Salzer, Switron, Recom, Varshno,(or similar) including disconnection, stripping, releasing of existing defective ASS. Also including the modifications of drill hole on panel to mount the new ASS, If required. | — | — | — | 6,336.5 | |
| — | 25.00 | — | — | ||
| Supply, fixing, connection, testing commissioning of Voltmeter Selector Switch, 4 position at 90 degree, with one OFF position, 16 amps, 440 Volts AC, panel mounted type, make Kaycee, Salzer, Switron, Recom, Vaishno (or similar); including disconnection, stripping, releasing of existing defective VSS. Also including the modifications of drill hole on panel to mount the new ASS, if required. | — | — | — | 5,969.75 | |
| — | 35.00 | — | — | ||
| Supply, fixing, connection, testing commissioning of Current Transformer of Bar Primary, Low Nos tension, tape wound, metering current transformer rated burden 15 VA, Accuracy class 1. CTR 5 Amp., (as per site requirement) voltage class 660 volts, of suitable size for the cables/bus-bar as per site requirement, Make AE, Siemens, Indotech, ICC (or similar); including disconnection, stripping, releasing of existing defective Current Transformer if any Material to be suplied with OEM test Certificate. | — | — | — | 14,062.65 | |
| — | 5.00 | — | — | ||
| Replacement of defective CT Operated AMP Meters on LT Panel, Digital AC Programmable Nos Amp Meters (Accuracy Class 1%) of reputed make. (Test report of all instruments to be provided) | — | — | — | 2,074.15 | |
| — | 5.00 | — | — | ||
| Replacement of defective Volt Meters on LT Panel by Digtal AC Volt Metes Range 0 to 500 No Volts (Accuracy Class+.1%) of reputed make (Test report of all instruments provided must be(Submitted). | — | — | — | 1,234.7 | |
| — | 6.00 | — | — | ||
| Repair of Main Panel (at site) as per Explainatory note including following scope of work : i)Reseting of all ACB/MCCBs ii)Checking of all termination iii) Checking of all busbars & terminations | — | — | — | 17,115 | |
| — | 2.00 | — | — | ||
| Replacement of 800 Amp 4 pole changeover switch as per site requirement. | — | — | — | 1,27,000 | |
| — | 120.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED BED LIGHT 1 WATT WITH COOL WHITE INBUILT DRIVER as per CEE/NR Specification. No. CEE/NR/121- Elect/PS/2018 (Rev '3') Dated 28.06.2018 | — | — | — | 1,62,000 | |
| — | 40.00 | — | — | ||
| Supply & erection of 63 A FP (TPN) MCB 10KA breaking capacity with Metallic enclosure. | — | — | — | 80,770 | |
| — | 360.00 | — | — | ||
| Supply, fixing and commissioning of 1x32 amp DP MCB complete in enclosure with earthing terminals. The MS box should be painted after red oxide primer as per requirement at site. | — | — | — | 2,29,284 | |
| — | 39.00 | — | — | ||
| Supply, fixing and commissioning of 50 watt LED Flood Light for Rolling Hut Lights | — | — | — | 79,950 | |
| — | 5.00 | — | — | ||
| Replacement of defective 400 Amps. On Load Change Over Switch on ET Panel with suitable four pole 400 Amp change over switch of reputed make as per site requirement. | — | — | — | 1,61,984.5 | |
| — | 800.00 | — | — | ||
| Manufacture, Supply, Erection of 4mm dia Gl wire guards, on stringed overhead ACSR No. conductor/Gl wire as per technical specification | — | — | — | 19,200 | |
| — | 200.00 | — | — | ||
| Supply & stringing of 4mm dia Gl wire (parallel to stringed ACSR conductor) binding with ms Mtr nut bolt of 16mm dia including supply as per technical specification. (Note:- Measurement will be done between pole to pole) | — | — | — | 1,400 | |
| — | 5000.00 | — | — | ||
| Sagging and stringing of ACSR conductor (6/1/259 or 6/1/335) on existing rail poles duly binding of conductor on insulators (ACSR conductor will be supplied by Rly) | — | — | — | 25,000 | |
| — | 5.00 | — | — | ||
| Supply, erection, testing and commissioning of 1KVA, Online UPS with isolation transformer & with Technology : IGBT-PWM, Input power: single phase AC, Voltage 160V TO 260V sinewave, 50Hz, Out put power : Single phase AC, Voltage 230 + / - 1% sinewave, 50Hz Minimum VAH-1872 VAH, 20% overload limit minimum 10 minutes yes, Back up time 120 minutes, Battery type:SMFVRLA confirming to JISF: 8702 (Pt. I,II,III ) with Warrantee : 02 years | — | — | — | 2,40,000 | |
| — | 5.00 | — | — | ||
| Supply, erection, testing and commissioning of Anti-theft Protective iron cage for UPS made of min. 5mmx5mm thick iron bars and 35x35x5mm angle with lockable door and with complete base coat & final coat of paint. The fixing should be as per site requirement. | — | — | — | 1,000 | |
| — | 290.00 | — | — | ||
| Supply, fixing, testing and commissioning of 3-pin ceiling rose 5 Amp capacity on existing MS/PVC conduit junction boxes/casing caping Anchor, Cona, Kinjal, SSK or equivalent as per IS, IE rules and site requirement. | — | — | — | 3,703.3 | |
| — | 73.00 | — | — | ||
| Supply and Erection of modular metal boxes concealed boards with white finish single mounting plate and fixing of switches/plug socket and connection wiring. Make Legrand (Myrius), Schneider (Zencelo), Anchor (Ave) or similar. Metal boxes boards are to be concealed in the wall for 12 Module | — | — | — | 28,329.84 | |
| — | 60.00 | — | — | ||
| Supply and Erection of modular metal boxes concealed boards with white finish single mounting plate and fixing of switches/plug socket and connection wiring. Make Legrand (Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 8 Module | — | — | — | 20,815.8 | |
| — | 42.00 | — | — | ||
| Supply and Erection of modular metal boxes concealed boards with white finish single mounting plate and fixing of switches/plug socket and connection wiring. Make Legrand (Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 6 Module | — | — | — | 15,540 | |
| — | 37.00 | — | — | ||
| Supply and Erection of modular metal boxes concealed boards with white finish single mounting plate and fixing of switches/plug socket and connection wiring. Make Legrand (Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 4 Module | — | — | — | 6,453.91 | |
| — | 376.00 | — | — | ||
| Supply, fixing, testing, and commissioning of modular type switch 6/10 Amps as per tech. specification IS/IE rules and site requirment. | — | — | — | 60,893.2 | |
| — | 52.00 | — | — | ||
| Supply, fixing, testing, and commissioning of modular type switch 16 Amps as per tech. specification IS/IE rules and site requirement. | — | — | — | 10,058.88 | |
| — | 52.00 | — | — | ||
| Supply, fixing, testing, and commissioning of modular type 6 pin socket 6/15 Amps as per tech. specification IS/IE rules and site requirement. | — | — | — | 13,733.2 | |
| — | 110.00 | — | — | ||
| Supply, fixing, testing, and commissioning of modular type multi socket 6 Amps 5 pin as per tech. specification IS/IE rules and site requirement. | — | — | — | 16,401 | |
| — | 1920.00 | — | — | ||
| Supplying, laying, testing and commissioning of FRLS 1.0 sq mm PVC insulated multistranded copper conductor s/core cable1100 Volt conforming to IS-694 (latest version), make Finolex, Havells, Polycab, KEI (or similar) in the recessed PVC conduit pipe 25 mm dia as required at site. | — | — | — | 23,692.8 | |
| — | 1000.00 | — | — | ||
| Supply, laying, fixing, testing and commissioning of 2.5sq mm FRLS, PVC insulated multistranded copper conductor single core cable 1100 Volts confirming to IS-694(latest version),make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as per Tech Spec-I attached, IS & IErules. | — | — | — | 18,230 | |
| — | 1000.00 | — | — | ||
| Supply, laying, fixing, testing and commissioning of 4 sq mm FRLS, PVC insulated multistranded copper conductor single core cable 1100 Volts confirming to IS-694(latest version),make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as per Tech Spec-I attached, IS & IErules. | — | — | — | 26,090 | |
| — | 40.00 | — | — | ||
| Supply & erection of 5M pole with double arm bracket hot dip galvanized octagonal pole with top 70 mm and bottom 130 mm around face made of 3 mm thick, steel base plate size 200x200x12 mm complete with appropriate sleeve at the top of the pole for mounting arm bracket 300 mm long suitable for LED street light fittings including casting, muffing with cement concrete foundation (1:2:4) painting, earthing and foundation GI nut, bolts with washer and smart pack junction box with single pole MCB and terminals as per explanatory note. | — | — | — | 4,05,253.2 | |
| — | 20.00 | — | — | ||
| Supply, installation, testing & commissioning of exhaust fan 250 mm sweep heavy duty colour white/blue blade with white dome, light weight& rust proof body and blade with self opening louvers including fixing inbox made by plywood board complete with connections with2x2.5sq.mm PVC insulated multi stranded FRLS copper conductor cable | — | — | — | 42,000 | |
| — | 30.00 | — | — | ||
| Design, manufacturing, supply, erection & commissioning of weather proof, floor mounted, dust & vermin proof as per IS:8623/1993 Pt-I to Pt III (Latest version) as per Drg No.CEE/NR/Elect/AC/311 outdoor type 415 Volt pre cooling cum battery charging box as per explanatory note as under: - a) Pre-cooling point portion of the box complete with 200 A Aluminium bus bar for phases & 160 A for neutral MCCB 100 Amp TPN = 1 No., 415 Volt, 63 A, 5 pin socket for operation on 3 phase 415 Volt AC system b) Battery charging point portion of the box complete with Aluminium bus bar 200 Amp, DP MCB 32 A DC = 1 No., 110 Volt 32 A 3 pin socket = 1 No. for operation on 110 DC system | — | — | — | 5,70,000 | |
| — | 6.00 | — | — | ||
| Supply & fixing of ON LOAD CHANGE OVER SWITCH IN SHEET STEEL ENCLOSURE WITH FRONT OPERATING ROTARY HANDLE & SHAFT AS PER FOLLOWING TECHNICAL DATA. (i) RATED OPERATING CURRENT: 63 AMPS. (ii) RATED OPERATING VOLTAGE: 415V AC. (iii) NO. OF POLE: 4, (iV) SPECIFICATION: IS: 13947 (PART-1 & 3), ( Warranty Period : Upto 30 months from the date of supply) | — | — | — | 13,939.2 | |
| — | 6.00 | — | — | ||
| Supply & fixing of On load change over switch capacity 100 AMPS suitable to operate in 415 V 50 Hz AC supply continuous rating with sheet steel enclosure four pole type confirming to IS 13947 Part I and III Make: Havells, L&T, C&S and SIEMENS or equivalent. ( Warranty Period : Upto 30 months from the date of supply) | — | — | — | 92,640 | |
| — | 10.00 | — | — | ||
| 3 Phase 4 wire ,LCD display, CT/VT operated Energy Meter complete with CT 200/5 & P V C box hinge type for easy operation as per specification enclosed at "Annexure-A" similar to Make: Secure model No. Premier 300 with Warranty of 10 years on meter & 5 years on CT. (Warranty Period : Upto 120 months from the date of delivery.) | — | — | — | 2,59,000 | |
| — | 3.00 | — | — | ||
| Supply, erection, testing and commissioning of the following Double door wall mounted Pre-fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; (i) Incoming MCCB 4Pole 125 A 35 KA B/C - 1 No. (ii). Outgoing MCB 6 to 32 A. SP 10 KA B/C (7 Nos. On each Phase) - 15 Nos. | — | — | — | 48,064.14 | |
| — | 13.00 | — | — | ||
| Supply, erection, testing and commissioning of the following Double door wall mounted Pre-fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; (i) Incoming MCCB 4Pole 63 A 35 KA B/C - 1 No. (ii). Outgoing MCB 6 to 32 A. SP 10 KA B/C (4 Nos. On each Phase) - 12 Nos. | — | — | — | 1,89,305.87 | |
| — | 4.00 | — | — | ||
| Design, Supply, fixing, testing and commissioning of outdoor type feeder pillar panel having IP-65 protection comprising with the following MCCB's fixed in it of make Havells, Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947-2 / IS13947:2008 & IS8623:2008 or latest with digital measuring instrument & bus-bar arrangement and conforming to PCEE/NR's spec. No.PCEE/NR/126-Elect/PS/2019 at Tech Spec-I attached or latest and as per IS, IE rules and site requirement. a) 4P MCCB 250Amps 36kA with adjustable thermal & fixed magnetic release =01 No. (Incoming) b) 4P MCCB 63Amps 36 kA with adjustable thermal & fixed magnetic release =05 Nos. (Outgoing) c) DP MCB 6-32 Amps10kA= 05 Nos. | — | — | — | 7,25,234.84 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CEESpecLED.pdf
ATTACHMENT
RewirngSpec-I.pdf
ATTACHMENT
GCC2022.pdf
ATTACHMENT
ACS1.pdf
ATTACHMENT
ACS2.pdf
ATTACHMENT
ACS3.pdf
ATTACHMENT
ACS4.pdf
ATTACHMENT
ACS5.pdf
ATTACHMENT
ACS6.pdf
ATTACHMENT
2024_05_14ClarificationregardingsubmissionofAnnexure-VofGCC.pdf
ATTACHMENT
GCCACS9.pdf
ATTACHMENT
CorrectionSlipNo7GCCofApr-2022.pdf
ATTACHMENT
CorrectionSlipNo8GCCofApr-2022.pdf
ATTACHMENT
CorrectionSlipNo10GCCofApr-2022.pdf
ATTACHMENT
TechSpecforFeederPIllar.pdf
ATTACHMENT
AnnexureAMeterSpecs.pdf
ATTACHMENT
251-J-Elect-T-22-2025-26.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .