| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹25.9 L+₹51,651.30 (2.04%)Rejected-Finance GALI MODI THEKEDAR AMLOH ROAD KHANNA DISTT LUDHIANA | KHANNA | LUDHIANA | PUNJAB | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹27.1 L+₹1.7 L (6.79%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹28.6 L+₹3.2 L (12.8%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹30.8 L+₹5.4 L (21.3%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹53,000
Closing Date
23 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
ADDN / ALTN TO MOs ROOM AND TOILETS INCLUDING ADJOINING AREA AT LGJ MIL STN
2021_MES_462162_1
8932-22/21-22
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
Class D cat a(i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹53,000
Yes
9 Sept 2021
23 Jul 2021
26 Aug 2021
23 Jul 2021
23 Aug 2021
7 Aug 2021
60 days
Amount
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engr-in-charge.
M&L for rendering, 10 mm thick on brick work or concrete surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement complete all as specified and directed by Engr-in-charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 on wall, finished even and fair including mixing of WPC in mortar complete all as specified and directed by Engr-in-charge. Note :- WPC shall be mearured and paid separately
Supply only integrated water proofing compound complete all as directed by Engr-in-charge. Make:- Dr Fixit/Fosroc/BASF/STP
Taking down existing shutter of any description exc 1.0 Sqm but not exc 2.0 Sqm each and refixing in same opening complete all as specified and directed by Engr-in-charge. Note:- 'Refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.)
M&L providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear meter including drilling and plugging holes etc. in apron complete all as specified and directed by Engr-in-charge.
M&L providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with CM 1:2 to match the existing floors complete all as specified and directed by Engr-in-charge.
M&L for Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and directed by Engr-in-charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge.
Excavating in post holes in soft soil (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed by Engr-in-charge.
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in post hole, foundation filling and mass concrete complete all as specified and directed by Engr-in-charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer-in-Charge.
M&L for glazed ceramic coloured tiles of size 450 x 300 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engineer-in-Charge.
M&L for 25 mm thick PCC (1:2:4) type B2 using 40mm graded stone aggregate as in sub-base complete all as specified and directed by Engineer-in-Charge.
M&L for brickwork with fly ash bricks, old size bricks, straight or curved on plan exc. 6 m mean radius built in cm 1:6 complete all as specified and directed by Engineer-in-Charge.
S&F steel ventilator with top hung shutter including hinges steel peg stay, complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of oil bound distemper over 3 mm thick wall care putty on plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment and two coats of oil bound distemper over 3 mm thick wall care putty on plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of white wash on old plastered surfaces of wall incl preparation etc. complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of cement base paint on old untreated plastered surfaces of wall including preparation etc. complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of cement base paint on New plastered surfaces of wall including preparation etc. complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long butt hinge, extruded aluminium alloy with galvanised mild steel hinge pin, anosied and fixed type B-21 complete all as specified and directed by Engineer-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections complete all as specified and directed by Engineer-in-Charge.
S&F 125 mm long aluminium anodised handle, cast type complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm long extruded aluminium alloy handle, fabricated type anodised complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel complete all as specified and directed by Engineer-in-Charge.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple platecomplete all as specified and directed by Engineer-in-Charge.
S&F for 300mm long aluminium alloy, anodised, sliding door bolt type not less than 16mm dia complete all as specified and directed by Engineer-in-Charge.
S&F 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed by Engineer-in-Charge.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
S&F drapery stainless steel rods, standrad quality, not less than 25mm dia with heads at both ends and middle support, rings, etc. complete all as specified and directed by Engineer-in-Charge.
S&F in repair bib tap, fancy type, cast copper alloy, chromium plated, with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferrule & fixed suitable for 15mm bore iron pipe complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS.
S&F in repair vitreous china wash hand basin coloured Flat back of size 550x400mm, long screwed shank fly nut flange end including cutting for and pinning in ends of brackets in 1:3 CM including 32mm dia chromium plated waste coupling/trap complete all as specified and directed by Engineer-in-Charge.
S&F in repair angle valve/stop cock/stop valve fancy type, cast copper alloy, chromium plated screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union, size 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS.
S&F in repair brass chromium plated Liquid soap dispenser including fixing to 15mm bore pipe complete all as specified and as directed by Engineer-in-charge.
S&F in repair corner glass shelf 200mm with Abs brackets complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass chromium plated PEG SET 6 including fixing to 15mm bore pipe complete all as specified and as directed by Engineer-in-charge.
S&F in repair chromium plated fancy type soap dish complete all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel Trap with grating round or square 150mm size (minimum weight 100gms) complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair tubular towel rail, Brass chromium plated 20 mm dia, 'D' type, 60cm long between flanges complete all as specified and as directed by Engineer-in-Charge.
S&F rotational moulded polythene water storage tank 1000 Ltr capacity, vertical with closed top hoisted and fixed in position including dismentling of water tanks of capacity exc 500 and n.exc 1000 ltrs and removing from site all as specified in SSR part-I. all as directed.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed in repair all as specified and as approved by GE/Engineer-in-Charge.
S&F in repair ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball scewed for iron pipe and fixed, (Minimum weight 20 mm-210 gms) complete, fixed in 20mm dia bore pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in 15mm dia bore pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair Self-closing flush taps for urinal, cast copper alloy, chromium plated, screwed for iron pipe and fixed 15mm bore pipe complete all as specified and directed by Engineer-in-Charge.
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe complete all as specified and directed by Engineer-in-Charge.
,---ditto-- all as per item No 51 above but 20mm dia pipe complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
,---ditto--- all as per item No 53 above but fixing only complete all as specified and directed by Engineer-in-Charge.
,---ditto--- all as per item No 53 above but 20mm dia pipe complete all as specified and directed by Engineer-in-Charge..
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge..
Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm any type of soil complete all as specified and directed by Engineer-in-Charge..
Removing excavated material n.exc 50m and depositing where direcrted at a level n.exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge..
M&L for plain cement concrete, type B1 1:2:4 using 20 mm graded stone aggregates in lintels upto 1.5m span, cills steps, seismic and other similar bands, plinth courses, copings, bed plates, and the like including weathering, slightly rounded or chamfered angles and throating, incl formworks complete all as specified and directed by Engineer-in-Charge..
M&L for PCC 1:2:4 type B2 using 40mm graded aggregates as in benching / haunchig of manholes including forming channels including necessary formwork etc. complete all as specified and directed by Engineer-in-Charge..
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:6 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engineer-in-Charge..
Material and labour for moorum bed to drain pipes, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
Supply and laying DWCPE (SN8) 180 (OD)/163 (ID) mm diameter drain pipes as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all accessories/fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge
Cutting into existing manholes for connection of new drain making pipes and rendering cutting out existing benching & forming branch channel in PCC 1:2:4 type B1 smooth finished & forming benches as reqd etc for 150 mm bore complete all as specified and directed by Engineer-in-Charge..
Providing and Applying rising damp proof coating system with single component ready to use damp proof coating Roff Hydamp 1. Preparation :- Throughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc all large voids and hallow portions must be removed and re-plastered non moving cracks having width upto 5mm must be filled with polymer based crack filler. 2. Application :- Apply the first coat of Dr. fixit dampguard classic with a paint brush directly on the prepared surfaces by mixing (1 part base : 1 part hardner : 1 part of water), allow to dry for a minimum 2-3 hrs. apply one part of Dampguard mixed chemical and 2 parts of OPC white cement / Birla putty and make the putty, apply putty on the entire surface area, allow to dry for at least 3-4 hrs, apply the final coat of air cure 48 hrs proceeds for paints.
S&F in repair arm strong mineral fibre accoustical suspended ceiling system with ANF (Micro look) EGE tiles with arm strong silhouette exposed grid. The tiles should have humidity resistance (RH) of 90% NRC 0.5% Light reflectance shall be more than 85% thermal conductivity K=0.052 - 0.057 W/mk. Colour shall lbe white, fire performance class 0/class 1 (BS 476) in module size of 600mm x 600mm x 15mm with bioblock coating on the face of tiles. Suitable for green building application with recycle content of 63%. The tiles shall be laid on arm strong silhouette profile grid system with 15mm with flanges incorporating 6mm central revel in white / black colour and with a web height of 45mm and and load carrying capacity of minimum 15.68 kg/Sqm. Silhouette, main runner and cross runner shall have mitred end and birdsmouth notches to provides mitred juction. The Tee section have a galvanised of 125 gms/Sqm complete all as specified and directed by Engr-in-Charge.
Surface excavation n.exc. (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge..
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in kerb stones size 300mm x 300mm x 100mm with plain fair faces, including chamfers, weathering, throating etc setting in CM 1:4 complete all as specified and directed by Engineer-in-Charge..
M&L for hard core of broken stone or boulders of gauge not exc 63mm deposited, spread & levelled in layers not exc 15cm thick, including watering and ramming to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.
M&L Machined pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 80mm thickness M-80 grade with over 25mm thick Fazilka sand cushion all as specified and directed. Note : Sand will be measured and paid seperatly
Suply only 25mm thick Fine aggregate (sand) for Cushioning (Fazilka sand) complete all as specified and directed by Engineer-in-Charge..
M& L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors complete all as specified and directed by Engineer-in-Charge..
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
AJAY CONSTRUCTION COMPANY
M/s Karan Builders
Aggarwal brothers and company
PAREEK AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .