| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹36.6 L+₹1.2 L (3.42%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹40.6 L+₹5.3 L (15.0%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
16 Mar 2020, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
CERTAIN SPECIAL REPAIRS, ADDITION/ALTERNATIONS AND MINOR WORKS AT DRDO AND DRDL AREAS UNDER GE(I) RND KANCHANBAGH HYDERABAD
2020_MES_327586_1
GE I KBAGH TOKEN 86 OF 2019 2020
Open Tender
Civil Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹92,000
Yes
27 Mar 2020
21 Feb 2020
18 Mar 2020
21 Feb 2020
16 Mar 2020
3 Mar 2020
22 Feb 2020 - 25 Feb 2020
Amount
Excavating in trenches n.exc 1.5m wide and not exc 1.50m deep and getting out in hard/dense soil for foundations, manholes/ laying of cables etc complete all as directed.
All as per srl item No.1 here-in-before but depth exc 1.5m and n.exc 3.0m complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick using soil complete all as directed.
S & F salt glazed stoneware drain pipe of 100mm internal bore of grade 'A' laid in trenches and jointed in cement mortar (1:2) including demolition of old unserviceable pipe complete all as directed.
S & F Reinforced concrete pipes 150mm dia, class NP3, laid and jointed with collars in cement mortar and laid over concrete bed in PCC 1:3:6, type C2 (using 40mm graded stone aggregate) including packing under, and haunching against the sides of pipes after they are laid and tested, in trenches including demolition of old unserviceable pipe complete all as directed. Note:- Collars required deemed to be included in the quoted rate.
S & F reinforced concrete pipes 150mm dia, class NP3, laid and jointed with collars in cement mortar and laid over concrete bed in PCC 1:3:6, type C2 (using 40mm graded stone aggregate) including packing under and haunching against the sides of pipes after they are laid and tested, in trenches complete all as directed. Note:- Collars required deemed included in the quoted rate.
S&F in repairs 150x150mm Salt-glazed stoneware gully traps, square or round mouthed, type 'P' complete all as directed.
S & F 150mm dia Cast iron pipes with spigot and socket ends centrifugally cast, class LA, in any length, laid in trenches complete all as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as directed
Demolition of plain cement concrete in ground floors/pavings n.exc 15cm thick below or above ground level in patches (repairs) complete all as directed
Demolition of RCC in ground floors/pavings n.exc 15cm thick below or above ground level complete all as directed.
M & L for plain cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation complete all as directed.
M & L for Brick work with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:4) complete all as directed.
M & L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement complete all as directed.
M & L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping, benching finished including necessary form work complete all as directed.
TMT bars 8mm dia cut to length, bent to shape required including cranking, bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as directed.
M & L for pre-cast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate) as in cover slabs including necessary form work etc,and placement of cover where required complete all as directed. Note:- Reinforcement shall be measured & paid separately.
Construction of brick masonry septic tank for 150 users capacity complete all a specified and as shown on drawing No.TD/AR/33/95 Sheet No.1/3 to 3/3 dated 17/07/95
Construction of Soakage wells of 1.80m dia and 3m effective depth complete all as specificed and as shown on drawing No.TD/100/2012 Sheet No.1/1 dated 28/05/12
M & L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in 100mm thick Path / PCC floor/sub base finished even and fair complete all as directed.
M&L for coloured chequered cement concrete tiles 30mm thick of approved shape and size not less than 0.09 sqm each, set and jointed , pointed in neat cement slurry in floors with grey cement and pigment over 15mm thick screed bed in cement mortar (1:6) including dismantiling of existing tiles alongwith screed bed complete all as directed.
Cleaning of man hole of any size and any depth (sludge materials) and placing back the manhole cover in Position and removing the sludge outside MD land complete all as directed.
S & F Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as directed,
S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm complete all as directed
S & F 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately) complete all as directed.
M&L for preparing untreated surface of ceiling board and applying two coats of OBD over alkali resistant primer complete all as directed.
Surface dressing n exc 15 cm deep and getting out in hard/dense soil complete all as directed.
M&L for Machine pressed pre cast concrete interlocking paver block of approved shape and size, with grey cement and pigment conforming to IS 15658-2006 of 60mm thick M-35 grade complete all as directed.
M&L for boulder pitching, laid dry, hand packed tightly and grouted with cement and sand mortar 1:6 complete all as directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as directed.
S&F aluminium frame powder coated any colour (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as directed.
M & L for complete removal of existing surface of walls and making good to surface and applying two coats of OBD over a coat of primer over a coat of 1.50mm thick smooth finished wall care putty complete all as directed.
M & L for complete removal of existing finish of ceiling and preparation of ceiling and applying two coats of OBD paint over a coat of primer over 1.50mm thick smooth finished wall care putty complete all as directed.
M & L for rendering 15mm thick in CM 1:6 on fair faces of brickwork finishing the surface even and smooth (without using extra cement) complete all as directed.
M & L for preparation of new plastered surface of walls and applying two coats of OBD over a coat of alkali resistant primer over two coats of wall care putty of 1.50mm thickness finished even and smooth complete all as directed.
M&L Non skid ceramic glazed tile 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed in CM 1:6 complete all as directed.
S & F Anodised aluminium snap grid frame work for false ceiling all as per SSR Part I 2009 complete all as directed.
S & F PVC insulation panels with EPS stuck to 1mm thick plain PVC sheet suitably placed in false ceiling grid all as per manufacturer's instruction complete all as directed.
M&L for excavation in post holes (or similar holes) each n exc 0.5 cum getting out in hard/dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25 cm, watering and removing surplus soil to a distance n exc 50 m and making good surface complete all as directed.
M&L for PCC 1:3:6, type C2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as directed.
S&F Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections confirming Fe 410 -W (Gde- E- 250) quality- A complete all as directed.
S&F steel/work in tubular trusses and similar work including special shaped washers complete using ERW or induction butt welded tubes conforming to IS-1161-1979, grade St-240 complete all as directed.
S&F prepainted galvalume aluminum zinc coating GI based corrugated/ style pattern steel sheet 0.50mm thick of any colour having tensile strength 550Mpa as in roof covering / cladding fixed with self tapping screws complete all as directed.
M&L for preparation of steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer, complete all as directed.
Surface excavation not exc 30cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as directed.
M&L for sand filling under floor including ramming and consolidating as required complete all as directed.
M&L for factory made pre-cast cement concrete kerb stone of PCC 1:2:4(using 20mm graded stone aggregate ) approved shape and size including chamfered angles weathering or slightly round throating etc including setting and jointing in CM 1:4 complete all as directed.
M&L for preparation of new plastered surfaces and applying two coats of synthetic enamel paint over a coat of primer complete all as directed.
Forming dovetailed 5 cm deep cavities, n exc 10cm x 10cm at top and 20cm x 20cm at bottom in concrete cast-in-situ (plain or reinforced) for holding down bolts, etc. for machinery, stanchions, etc. including temporary forms or moulds and carefully grouting round bolts (after fixing) with cement concrete 1:2:4, type B1, (20mm graded stone aggregate) or cement mortar 1:3, complete all as directed.
M&L for PCC (1:3:6) type C-1 (using 20mm graded stone aggregated) as in cill, step and for inserting hold fast of doors and windows complete all as directed.
S & F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as directed.
S&F factory made 18mm(+0.7mm) thick celuka PVC Ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company. One side prelam and other side plain 18mm thick Celuka PVC ply for cabinet shutter and also manufacturer's test report and test certificate is mandatory with each and every supply of the materail complete as per directions of Engineer-in-charge, manufacturer's specifications and drawing complete all as directed.
S&F factory made 18mm(+0.7mm) thick celuka PVC Ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company. Plain 18mm thick Celuka PVC Ply for Shelf/Partitions/ Drawer and also manufacturer's test report and test certificate is mandatory with each and every supply of the materail complete as per directions of Engineer-in-charge, manufecturer's specifications and drawing.
S&F 500mm designer handle stainless steel matt/glossy finish complete all as directed
S&F for 50mm magnetic catches and fixed complete all as directed.
S&F cabinet concealed hinges auto close openable angle 110 Degree for fixing wardrobe shutter complete all as directed.
S&F lift adherence HF (inside cross height 440-550mm with gas spring set for advance lift up (HF) overhead telescopic friction stay 380 - 550 mm, adjustable length:380 - 550 mm , suits door width:500 - 700mm rod diameter:15 mm for fixing wardrobe shutter complete all as directed.
S & F Godrej Locks 32 mm curvo wardrobe lock (standard size, silver) complete all as directed.
S & F push to open (P 2 O) opening system screw for all auto closing non slides hinges with long stroke 37mm complete all as directed.
M & L for rendering 10mm thick in CM 1:3 on ceiling surfaces and finishing the surface even and smooth (without using extra cement) including taking down cement plaster complete all as directed.
M & L for rendering 10mm thick in CM 1:6 on brick work /concrete surfaces and finishing the surface even and smooth (without using extra cement) including taking down cement plaster complete all as directed.
M&L for 10 mm thick light shade vitrified ceramic tiles , area of each tile n exc 0.36 sqm as in floors, joint free, set in neat cement slurry and pointed in cloured cement to match laid over and including 15mm thick screed bed in CM (1:6) including demolition of old existing tiles alongwith existing bedding, complete all as directed.
All as per srl item No.63 here-in-before but as in vertical surface over 10mm thick backing coat in CM 1:4 complete all as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to exisiting finish without any extra cost to Govt.), complete all as directed.
S & F Second class HW plain solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as directed.
S & F Flush shutter 40mm thick, solid core construction with block board core and plywood face panels commercial type on both sides, complete all as directed.
S& F 0.9mm thick Decorative laminates type I, of Surface finish, colour and pattern as approved and fixed with approved adhesive as per manufacturer's instruction complete all as directed.
M & L for Brick work with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as directed.
Cutting openings, through brick walls for door, window and other opnings or enalarging exisiting openings. Converting window into door openings,etc. or cutting out defective brick work for under -pinning, including providing, fixing and cleaning complete all as directed.
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as directed.
S&F GI water tubing of 15mm dia medium grade, with necessary fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete all as directed
S&F GI water tubing of 20mm dia medium grade, with necessary fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete all as directed
M & L for hard core of broken stone boulders of guage n. exc 63mm, deposited, spread and leveled in layers not exc 15 cm thick watered and rammed to a true surface complete all as directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate), 40mm thick as in floors finishes, even and smooth (without using extra cement) complete all as directed.
Removing excavated material (Soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as directed.
S&F door closer hydraulically regulated, aluminum body (Die cast), designation No 3, universal type, suitable for door shutter of size 851 to 1000mm in width and weight between 61 to 80 Kg complete all as directed.
Supply and fix venetian blinds, (vertical type) of 100mm wide of approved, fabric blinds including all necessary fittings of approved colour to match with the existing, complete all as directed.
S & F WHB vitreous china, Flat back or angle back type of size 600x480mm, white including cutting for & pinning in ends of brackets or existing stand including PVC waste pipe and fitting 32mm dia complete all as directed
S&F towel rail 600mm long of PTMT fixed with and including chromium plated brass screw and wooden/ plastic cleats (Min wt 190gms), complete all as directed.
S & F stop valve of 15mm dia cast copper alloy, screwed down high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions, complete all as directed.
S & F 15 mm dia, Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure with or without lettered ‘Hot’ or ‘Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as directed.
S & F PVC connection pipe 15mm dia, 450mm long with PTMT check nuts and washer on both ends complete all as directed
S & F PVC (SWR) pipes 110mm bore, single socketed in any length with rubber ring joints fixed to wall or laid in floors complete all as directed.
S & F PVC (SWR) pipes 75mm bore, single socketed in any length with rubber ring joints fixed to wall or laid in floors complete all as directed.
S & F PVC (SWR) bends (any radius) suitable for 110 mm bore pipe complete all as directed.
S & F PVC (SWR) bends (any radius) suitable for 75 mm bore pipe complete all as directed.
S&F PVC (SWR) junction single T equal or unequal of 75 mm bore with access door , complete all as specified and as directed.
S&F PVC (SWR) junction single T equal or unequal of 110 mm bore with access door,complete all as specified and as directed.
S&F low density polyethyene pipes 100 mm dia (LDPE) of pressure rating 6 Kg /Sqcm laid in floor, fixed to walls or ceiling, complete all as directed.
S & F grating doom 100mm dia of PTMT (minimum weight 25gms) complete all as directed.
S&F 100mm dia outlet PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as directed.
S&F aluminium anodized, barrel tower bolt of extruded section, 125mm long complete all as directed
S & F Aluminium alloy, anodised sliding door bolt 250mm long, with hasp, staple (Bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, complete all as directed.
S&F 150 mm size aluminum handles, cast type, anodised complete all as directed
S&F Butt hinges 100mm size extruded brass with mild steel hinge pin, bright polished type C12 complete all as directed.
S&F Floor door stopper 150mm long of Brass body and tongue with hard drawn steel spring fixed in floor complete all as directed.
S&F false ceiling with pre-coated standard GI angle, Tee and grid suspended with 2 mm dia GI wire at 600mm c/c, Angle of size 25x25x0.7mm fixed around, main Tee and Cross Tee of the section 38x25x0.7mm with soffits clips, holding and level clips, Gypsum board of 12.5 mm thick with white paper layer on face side of size of size 600x600 mm or any size as directed and applying two coats of acrylic emulsion over a coat of primer including dismantling of existing old false ceiling complete all as directed
Supply and install 5 star Inverter type hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality Inverter type, of capacity 1 TR with CFC free Refrigerant gas like R-410 suitable to operate on 230V single phase supply, including Refrigerant, copper tube of suitable dia. from indoor to outdoor unit, Insulation felt to copper tubing, power cable/controll wiring from indoor to outdoor units,supply power cable & connection through Stabilizer to indoor unit, provision of rigid UPVC condesate drain piping from indoor unit to ground level etc., complete all as directed. Make : LG/Voltas/Bluestar
Supply and install 5 star Inverter type hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality Inverter type, of capacity 2 TR with CFC free Refrigerant gas like R-32 suitable to operate on 230V single phase supply, including Refrigerant, copper tube of suitable dia. from indoor to outdoor unit, Insulation felt to copper tubing, power cable/controll wiring from indoor to outdoor units,supply power cable & connection through Stabilizer to indoor unit, provision of rigid UPVC condesate drain piping from indoor unit to ground level etc., complete all as directed. Make : LG/Voltas/Hitachi/Daikin
Supply and install testing and commissioning Voltage Stabilizer of capacity 4 KVA for autoatic correction and operation single phase neutral air cooled split type and designed for input various between 170 to 250V with output stabilier at 230V with necessary +/- 2.5% complete all as directed.
S&F MCCB 100 Amps, 10 KA, 4 pole, 415 volts, 50 Hz alongwith MCCB enclosure including necessary fixing arrangement for fixing of MCCB to the existing panel connecting cable connections complete all as directed by Engr-in-Charge. Make : STANDARD/HAVELLS /L&T
M&L for XLPE insulated , armoured heavy duty electric cable with aluminium conductor , 1100 volts grade of cross- sectional area 16 sq mm 4.0 core including taking down existing cable complete all as directed.
Supply and spreading of dry clean natural river sand in trenches/ transformer yard / two pole structure yard for cable protection complete all as directed. Note:- Punned thickness only shall be measured for payment purpose.
M&L for laying common burnt bricks, sub class 'B', of size 230 x 115 x 75 mm in trenches for cable protection complete all as directed.
S&F Galvanised iron tubing 100 mm dia, light grade, laid in trenches/floors/walls for eath lead protection and cables at road crossing etc complete all as directed.
Supply, connect and testing voltage stabiliser of capacity 5 KVA single phase 230 volts 50 cycles wall mounting type suitable for 2 TR split AC with low/high voltage cut off and intelligent time delay 3 minutes + - 20% seconds of working range 170 volts to 270 volts complete all as specified and directed.
Material and Labour for sub main wiring with 2 runs of 6 Sqmm single core PVC insulated unsheathed cable 1100 Volts grade multistranded with copper conductor drawn through and including rigid PVC conduit medium grade of 25 mm dia and conduit accessories such as bends,tees,junction boxes concealed/surface type on walls, roof, floors etc including 1 run of 6 Sqmm PVC insulated copper conductor cable as earth continuity wire including taking down unserviceable sub main wiring and conduit complete all as directed. Note: 2 Runs of 6 sqmm cable, 1 run of 6 sqmm earth continuity conductor and 1 run of PVC conduit shall be measured as one unit.
Material and Labour for sub main wiring with 2 runs of 4 Sqmm single core PVC insulated FRLS unsheathed cable 1100 Volts grade multistranded with copper conductor drawn through and including rigid PVC conduit medium grade of 25 mm dia and conduit accessories such as bends,tees,junction boxes concealed/surface type on walls, roof, floors etc including 1 run of 4 Sqmm PVC insulated copper conductor cable as earth continuity wire including taking down unserviceable sub main wiring and conduit all as directed. Note: 2 Runs of 4 sqmm cable, 1 run of 4 sqmm earth continuity conductor and 1 run of PVC conduit shall be measured as one unit.
Supplying and Fixing single pole sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 10 KA 'C' series, 240 Volts and removing the unserviceable sheet metal enclosures complete all as directed.
Taking down old unserviceable aluminium point wiring (Light, Fan, Socket or power) complete including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc and making good to the disturbed surfaces of walls,ceilings and floor etc.
Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated unsheathed multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit not less than 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including sunk type galvanised terminal boxes fabricated out of 1.60 mm thick suitable for switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified for the following:- Note- Rates include the cost of modular plate and covers of suitable modules as required at site.
One light/ fan point controlled by one switch
One 5 Amps socket point on independent board.
One 5 Amps socket point on same board with other switches
All as per item No. 114 here-in-before, but wiring with 4 Sqmm for 15/5 Amps switch socket combination /two pin earth plug and socket including providing 4sqmm PVC insulated multi stranded unsheathed copper earth continuity conductor and connected to common earth dolly.
All as per item No. 115 here-inbefore but same board
M&L for point wiring complete with 2.5 Sqmm PVC insulated FRLS unsheathed single core multistranded copper conductor 1100 V grade drawn through and including 20 mm dia PVC conduit concealed/surface and terminated to sunken box of modular type including white cover plates suitable for fixing modular switches,modular sockets,modular regulators etc including 2.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly and taking down old point wiring complete all as directed. Make for item No. 115 to 118:Cable : Finolex/Havells/Gloster PVC Conduit: Sudhakar/ Diamond/Avon
Supply and Fixing Modular switch single pole, one way 6 Amps one module complete all as specified and directed.
Supply and Fixing Modular switch single pole, one way 16 Amps one module complete all as specified and directed.
Supply and Fixing Modular socket 6 Amps multipurpose 2 in 1- 2/3 pin combined 2 module complete all as directed.
Supply and Fixing Modular socket 6/16 Amps multipurpose 2 in 1 -2/3 combined 2 module complete all as specified and directed. Make for item No. 118 to 121 :- Legrand/L&T/ Schneider/ Crabtree
Supply & Fix modular step type fan regulator 120 W, 2 module complete all as directed.
Supply and Fixing ceiling rose three terminals Poly carbonated isolated body complete all as directed. Make : Anchor/Cona/GM
Supply and Fix MCCB Distribution board, TPN 8 way, sheet metal enclosure double door, factory made, fixed on wall /semi-flushed in the wall,415 Volts with 200 Amps rated bus bars, neutral link and earth bar suitable for MCCB incoming and MCB SP/TP out goings including taking down unserviceable distribution board and making good to the disturbed surfaces of wall all as specified and directed.
Supply and Fix MCB Distribution board, SPN 12 way sheet metal enclosure double door, factory made, fixed on wall /semi-flushed in the wall, 240 Volts with 200 Amps rated bus bar, neutral link and earth bar suitable for mounting MCB SP/DP including taking down unserviceable distribution board and making good to the disturbed surfaces to match with existing surfaces of wall complete all as directed.
Supply & Fix MCB TPN 63 Amps, 10 KA, 'C' curve complete all as directed
MCCB 100Amps, 415V, 4 pole with 25KA, thermal magnetic adjustable at overload & short circuit release as per IS-13947 and the Ics should be 100% of Icu & should be provided with suitable spreader links and phase barriers for each terminals with all accessories complete all as directed. Make:Legrand/Schneider/L&T
Supply and Fix MCB SP 6 to 32A, 'C' curve, 10 KA complete all as directed.
Supply and Fix MCB SPN 32 A, 10KA, 'C' curve complete all as directed.
Supply and Fix MCB 240Volts 32 Amps complete all as directed. Make for srl item No. 124 to 130 : L&T/Legrand/Schneider
Supply and Fix GI tubing 25 mm dia light grade for protection of earth conductor complete all as directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m deep below normal ground level with top edge of earth plate, not less than 1.5 m below normal ground level connected to galvanised iron earth lead of size 4.0 mm dia by means of bolts, nuts/check nuts and washers etc of galvanised iron, protected by galvanised iron pipe light grade 15 mm dia upto a length of 7.5 m away from earth electrode and connected to main switch/control board including necessary excavation earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40 mm thick RCC cover slab 1:2:4 type B1 with 8mm dia TMT Bars at 140 mm c/c both ways, GI watering pipe 20 mm dia medium grade, funnel, wire mesh, lugs, charcoal and salt etc complete all as shown in Electrical plate No. 3 SSR Part I and testing complete including removing unserviceable items all as specified and directed. Note: Quoted rate is deemed to include the cost of terminal boxes
S&F GI strip 25x4 mm with saddles and fixing screws on epoxy insulators along the wall above 30 cm of the floor
Supply & Fix recessed mounted energy efficient LED luminaire 34W, 840 direct-indirect soft line designed color temp 6500 K, including constant current electronic driver suitable for false ceiling complete with all accessories prewired and connecting up with three core flexible copper conductor cable of suitable size removing unserviceable fittings complete as all directed. Make : Havells cat part No.PLUTONEO2X2PLR34WLED857S or equivelent of Philips/Wipro
Supply and fix indoor industrial batten type energy efficient LED luminaire 18/20W, 230 volts surface/wall mounted LED batten including one no. 18/20W LED polycarbonate tube (single side connection) with integrated alluminium heat sink complete with all accessories prewired including connecting up with twin core flexible copper conductor cable suitable size complete as directed. Make : Havells Cat No. of batten REGAL BATTENT8UPTO1X22WSSBSWH & Cat No. of LED tube TITANIANEO1213T8SSTL18WLED865SPC or equivalent of Philips/Crompton/Wipro
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95sqmm 3.5 core in existing trenches/ fixing to wall using necessary saddles and lugs for terminations complete all as directed.
S&F AC metal clad plug and socket enclousure single pole and neutral with a two pin and earth plug and socket with MCB SP of 20Amps rating complete all as directed Make:- C&S/Legrand/Schneider
S&F DB with metal clad plug and socket controled by MCB 5-20Amps capacity operating on 230 volts AC 50 Hz electrical supply complete all as directed.
S&F sheet metal enclosure MCB DB SPN 8 way double door, single phase, 240 Volts 200 Amps rated busbar capacity complete all as directed. Make :L&T/ Legrand/ Schnieder/ Havells
Indu Electricals
M/s ANUSHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .