Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹90.0 CrAdmitted-Finance | ₹90.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹90.2 Cr+₹28.4 L (0.32%)Admitted-Finance PLOT NO 101 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA 134113 | PANCHKULA | HARYANA | 134113 | ₹90.2 Cr+₹28.4 L (0.32%) | L2 | Admitted-Finance |
| 3 | L3₹117.9 Cr+₹28.0 Cr (31.1%)Admitted-Finance PLOT NO 1080 LEVEL 21 AND 22 BIRLA AURORA DR ANNIE BEASANT ROAD MUMBAI MUMBAI MAHARASHTRA 400030 | MUMBAI | MAHARASHTRA | 400030 | ₹117.9 Cr+₹28.0 Cr (31.1%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | powertech electroinfra pvt ltd L1 | DESOLPOWER & SAFETY PRIVATE LIMITED L2 | Siemens Energy India Limited L3 |
|---|---|---|---|---|---|---|
| 1.00 | GIS SYSTEM:
Note: The GIS offered in the tender shall be of single make for each respective voltage level (make of GIS can’t be varied for a single voltage level).
220kV GIS :
The 245kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 gas insulated switch gear rated for 220kV, 3-phase, and 50 HZ 50kA/1 Sec. fault level shall be of the indoor metal-enclosed type, comprising of following items.
(Presently Seimens Make at substation):
245kV, 2000A, single 3–ph or three 1 –ph, SF6 gas insulated, metal enclosed Bus bar arrangement, consisting of 2000A single 3 – I or three 1 –I SF6 gas insulated switchgears, each Bus Bar comprising of
(Presently Siemens Make GIS at substation) :-
i) Bus bar enclosures running the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system.
ii) 2000A,One 3– or three 1 –ph, single pole, group operated isolator/disconnector with one, 3 – I or three 1 –I, single pole, group operated earthing switch with manual and motor driven operating mechanisms.
iii) 2000A, One high speed 3 – ph or three 1–ph, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
iv) GIS Bus Duct with gas monitoring device,pressure switch etc. as required.
v) Terminal boxes/Local Control Cubicle.
vi) Interconnecting wiring/ piping.
vii) Grounding, support structures and platforms. | 10 | Set | 100 ₹1,18,118 Lowest | 10,44,03,375 ₹12,68,23,153.82 | 70,62,655.6 ₹83,33,933.61 |
| 2.00 | 245kV, 1250A, single 3 –I or three 1 –I, Transformer feeder circuit breaker bay module, consisting of 1250A single 3 – I or three 1 – I SF6 gas insulated switchgears, for transformer, each comprising of:
i) 1250A, One 3 – I or three 1 –I, SF6 gas insulated circuit breaker, complete with operating Mechanism.
ii) Three, 5-core, single phase current transformers
(450-300/0.577-1-1-1-1A)
iii) 1250A, One 3 – ph or three 1 –ph, single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
iv) 1250A, One 3 – ph or three 1 –ph, single pole, group operated isolator/disconnector with one 3 – I or three 1 –I, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
v) 1250A, One 3 – ph or three 1 –ph, single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ph or three 1 – ph, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.
vi) GIS Bus Duct with gas monitoring device,pressure switch etc. as required.
vii) Terminal boxes/Local Control Cubicle.
viii) Interconnecting wiring/ piping.
ix) Grounding,support structures and platforms. | 2 | Set | 9,00,00,000 ₹10,62,18,880 | 4,24,96,000 ₹5,16,30,055.8 Lowest | 5,69,01,352.34 ₹6,87,91,536.35 |
| 3.00 | 245kV, 1250A, single 3 – f or three 1 –f, Transmission line feeder circuit breaker bay modules, consisting of 1250A single 3 – f or three 1 –f SF6 gas insulated switchgears, each comprising of:-
1250A, One 3 – f or three 1 – f, SF6 insulated circuit breaker, complete with operating mechanism.
Three, 5- core, single phase current transformers
(1200-800-400/1-1-1-1-1A)
1250A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
1250A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector with one, 3 – f or three 1 – f, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
1250A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – f or three 1 – f, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
Each GIS compartment with gas monitoring device, pressure switch etc. as required.
Terminal boxes/ Local Control Cubicle.
Interconnecting wiring/ piping.
Grounding, support structures and platforms. | 6 | Set | 27,00,00,000 ₹31,86,56,640 | 13,56,30,000.06 ₹16,47,82,202.38 Lowest | 18,61,62,927.36 ₹22,46,16,076.05 |
| 4.00 | 132kV GIS :
The 145kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 gas insulated switch gear rated for 132kV, 3-phase, and 50 HZ 50kA/1 Sec. fault level shall be of the indoor metal-enclosed type, comprising of following items.
(Presently Seimens Make at every required substation):
145kV, 1250A, single 3 – or three 1 –, SF6 gas insulated, metal enclosed bus bars arrangement, consisting of single 3 – or three 1 – SF6 gas insulated switchgears, each Bus Bar comprising of :-:-
i) Bus bar enclosures running through the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system..
ii) GIS Bus Duct with gas monitoring device, pressure switch etc. as required
iii) Terminal boxes/ Local Control Cubicle.
iv) Interconnecting wiring/ piping.
v) Grounding, support structures and platforms. | 2 | Set | 20 ₹11,823.6 Lowest | 2,08,80,675 ₹2,53,68,750.36 | 14,12,531.12 ₹16,66,786.72 |
| 5.00 | The 145kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 gas insulated switch gear rated for 132kV, 3-phase, and 50 HZ 50kA/1 Sec. fault level shall be of the indoor metal-enclosed type, comprising of following items.
(Presently Seimens Make at every required substation):
145kV, 2000A, single 3– or three 1-, SF6 gas insulated, metal enclosed Bus bar arrangement, consisting of 2000A single 3- or three 1- SF6 gas insulated switchgears, each Bus Bar comprising of
(Presently Siemens Make GIS at substation) :-
i) Bus bar enclosures running the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system.
ii) Jointing plugs/ adapters etc. as per site condition
iii) Each GIS compartment with gas monitoring device, pressure switch etc. as required..
iv) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.
v) Interconnecting wiring/ piping.
vii) Grounding, support structures and platforms. | 2 | Set | 20 ₹11,823.6 Lowest | 2,08,80,675 ₹2,53,68,750.36 | 14,12,531.12 ₹16,66,786.72 |
| 6.00 | 145kV, 1250A, single 3 –ph or three 1 – ph , Transformer feeder circuit breaker bay module, consisting of single 3 – or three 1 – SF6 gas insulated switchgears for 132/11KV transformer each comprising of:-
i) 1250A , One 3 – ph or three 1 – ph , SF6 gas insulated circuit breaker, complete with operating Mechanism. ii)Three, 4-core, single phase current transformers (250-150-100/0.577-1-1-1A)
iii) 1250A , One 3 – ph or three 1 – ph , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
iv) 1250A , One 3 – ph or three 1 – ph , single pole, group operated isolator/disconnector with one 3 – I or three 1 –I, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
v) 1250A , One 3 – ph or three 1 – ph , single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – I or three 1 – I, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.
vi) GIS Bus Duct with gas monitoring device, pressure switch etc. as required.
viiTerminal boxes/Local Control Cubicle.
viii) Interconnecting wiring/ piping.
ix) Grounding, support structures and platforms. | 1 | Set | 3,00,00,000 ₹3,54,05,900 | 2,12,48,000 ₹2,58,15,027.9 Lowest | 2,14,64,356.01 ₹2,58,97,706.79 |
| 7.00 | 145kV, 800A, single 3 – f or three 1 –f, Transmission line feeder circuit breaker bay modules, consisting of single 3 – f or three 1 –f SF6 gas insulated switchgears, each comprising of:-
800A, One 3 – f or three 1 –f, SF6 gas insulated circuit breaker, complete with operating mechanism for outgoing feeder.
Three, 3-core, single phase current transformers (600-300-150/1-1-1A).
800A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
800A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector with one, 3 – f or three 1 – f, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
800A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – f or three 1 – f, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
Each GIS compartment with gas monitoring device, pressure switch etc. as required.
Terminal boxes/ Local Control Cubicle.
Interconnecting wiring/ pi
Grounding, support structures and platforms | 2 | Set | 6,00,00,000 ₹7,08,11,800 | 4,52,10,000.02 ₹5,49,27,400.79 | 4,15,01,168.1 ₹5,01,10,911.74 Lowest |
| 8.00 | 66kV GIS:
The 72.5 kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement with one line feeder bay to be connected with existing GIS System along with bus bar and jointing plugs/ adapter etc. The SF6 gas insulated switch gear rated for 66kV, 3-phase, 50 HZ, 31.5KA fault level shall be of the indoor metal-enclosed type, comprising of following items (presently Sieyuan make at substation).
72.5kV, 3150A, single 3 – or three 1 –, SF6 gas insulated, metal enclosed Bus bar arrangement, consisting of 2000A single 3 – or three 1 – SF6 gas insulated switchgears, each Bus Bar comprising of:-
i. Bus bar enclosures running the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system.
ii. Jointing plugs/ adapters etc. as per site condition.
iii. Each GIS compartment with gas monitoring device, pressure switch etc. as required.
iv. Terminal boxes/ Local Control Cubicle.
v. Interconnecting wiring/ piping.
vi. Grounding, support structures and platforms. | 2 | set | 20 ₹7,103.6 Lowest | 2,08,80,675 ₹2,53,68,750.36 | 14,12,531.12 ₹16,66,786.72 |
| 9.00 | 72.5kV, 2000A, single 3 – or three 1 –, Transmission line feeder circuit breaker bay modules, consisting of 2000A single 3 – or three 1 – SF6 gas insulated switchgears, each comprising of:-
i. 2000A, One 3 – or three 1 – , SF6 insulated circuit breaker, complete with operating mechanism.
ii. Three, 3- core, single phase current transformers (600-300-150/1-1-1A)
iii. 2000A, One 3 – or three 1 – , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
iv. 2000A, One 3 – or three 1 – , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
v. 2000A, One 3 – or three 1 – , single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – or three 1 – , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
vi. Each GIS compartment with gas monitoring device, pressure switch etc. as required.
vii. Terminal boxes/ Local Control Cubicle.
viii. Interconnecting wiring/ piping.
ix. Grounding, support structures and platforms. | 1 | set | 3,00,00,000 ₹3,54,03,540 | 2,26,05,000.01 ₹2,74,63,700.4 Lowest | 3,23,63,176.72 ₹3,87,58,315.22 |
| 10.00 | 220kV XLPE Copper cables (4x1CX1000mm2) to connect 220kV Transmission Line feeders with GIS. | 2,200 | Metres | 4,95,00,000 ₹5,85,39,800 | 3,74,47,872 ₹4,62,57,890.36 Lowest | 6,33,51,222 ₹8,03,46,926.88 |
Tender Value
Refer Docs
EMD Value
₹1.3 Cr
Closing Date
16 Feb 2026, 5:00 pmClosed
SE/Contracts
Shakti Bhawan, Sector-6, HVPNL, Panchkula
Execution of approved/ planned additional (bay) works at various 220/132/66 kV level GIS S/Stns in Haryana.
2025_HBC_479751_1
202563A9EE03 8A47 4C6D 9DF7 0486B3D7DC1D821HVP
Open Tender
Electrical Works
Works
365 days
Gurugram Sonepat Faridabad (MC) Panipat
4 documents required · 4 mandatory
₹11,800
₹1.3 Cr
Yes
20 Apr 2026
27 Oct 2025
24 Feb 2026
27 Oct 2025
16 Feb 2026
27 Oct 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | GIS SYSTEM:
Note: The GIS offered in the tender shall be of single make for each respective voltage level (make of GIS can’t be varied for a single voltage level).
220kV GIS :
The 245kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 gas insulated switch gear rated for 220kV, 3-phase, and 50 HZ 50kA/1 Sec. fault level shall be of the indoor metal-enclosed type, comprising of following items.
(Presently Seimens Make at substation):
245kV, 2000A, single 3–ph or three 1 –ph, SF6 gas insulated, metal enclosed Bus bar arrangement, consisting of 2000A single 3 – I or three 1 –I SF6 gas insulated switchgears, each Bus Bar comprising of
(Presently Siemens Make GIS at substation) :-
i) Bus bar enclosures running the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system.
ii) 2000A,One 3– or three 1 –ph, single pole, group operated isolator/disconnector with one, 3 – I or three 1 –I, single pole, group operated earthing switch with manual and motor driven operating mechanisms.
iii) 2000A, One high speed 3 – ph or three 1–ph, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
iv) GIS Bus Duct with gas monitoring device,pressure switch etc. as required.
v) Terminal boxes/Local Control Cubicle.
vi) Interconnecting wiring/ piping.
vii) Grounding, support structures and platforms. | 10 | Set | - | - |
| 2 | 245kV, 1250A, single 3 –I or three 1 –I, Transformer feeder circuit breaker bay module, consisting of 1250A single 3 – I or three 1 – I SF6 gas insulated switchgears, for transformer, each comprising of:
i) 1250A, One 3 – I or three 1 –I, SF6 gas insulated circuit breaker, complete with operating Mechanism.
ii) Three, 5-core, single phase current transformers
(450-300/0.577-1-1-1-1A)
iii) 1250A, One 3 – ph or three 1 –ph, single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
iv) 1250A, One 3 – ph or three 1 –ph, single pole, group operated isolator/disconnector with one 3 – I or three 1 –I, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
v) 1250A, One 3 – ph or three 1 –ph, single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – ph or three 1 – ph, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.
vi) GIS Bus Duct with gas monitoring device,pressure switch etc. as required.
vii) Terminal boxes/Local Control Cubicle.
viii) Interconnecting wiring/ piping.
ix) Grounding,support structures and platforms. | 2 | Set | - | - |
| 3 | 245kV, 1250A, single 3 – f or three 1 –f, Transmission line feeder circuit breaker bay modules, consisting of 1250A single 3 – f or three 1 –f SF6 gas insulated switchgears, each comprising of:-
1250A, One 3 – f or three 1 – f, SF6 insulated circuit breaker, complete with operating mechanism.
Three, 5- core, single phase current transformers
(1200-800-400/1-1-1-1-1A)
1250A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
1250A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector with one, 3 – f or three 1 – f, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
1250A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – f or three 1 – f, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
Each GIS compartment with gas monitoring device, pressure switch etc. as required.
Terminal boxes/ Local Control Cubicle.
Interconnecting wiring/ piping.
Grounding, support structures and platforms. | 6 | Set | - | - |
| 4 | 132kV GIS :
The 145kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 gas insulated switch gear rated for 132kV, 3-phase, and 50 HZ 50kA/1 Sec. fault level shall be of the indoor metal-enclosed type, comprising of following items.
(Presently Seimens Make at every required substation):
145kV, 1250A, single 3 – or three 1 –, SF6 gas insulated, metal enclosed bus bars arrangement, consisting of single 3 – or three 1 – SF6 gas insulated switchgears, each Bus Bar comprising of :-:-
i) Bus bar enclosures running through the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system..
ii) GIS Bus Duct with gas monitoring device, pressure switch etc. as required
iii) Terminal boxes/ Local Control Cubicle.
iv) Interconnecting wiring/ piping.
v) Grounding, support structures and platforms. | 2 | Set | - | - |
| 5 | The 145kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement shall be kept in GIS hall for adding future bays and jointing plugs required for connecting GIS of different makes. The SF6 gas insulated switch gear rated for 132kV, 3-phase, and 50 HZ 50kA/1 Sec. fault level shall be of the indoor metal-enclosed type, comprising of following items.
(Presently Seimens Make at every required substation):
145kV, 2000A, single 3– or three 1-, SF6 gas insulated, metal enclosed Bus bar arrangement, consisting of 2000A single 3- or three 1- SF6 gas insulated switchgears, each Bus Bar comprising of
(Presently Siemens Make GIS at substation) :-
i) Bus bar enclosures running the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system.
ii) Jointing plugs/ adapters etc. as per site condition
iii) Each GIS compartment with gas monitoring device, pressure switch etc. as required..
iv) Terminal boxes/ Local Control Cubicle consisting of all protection relays, mechanism control system, indication system etc.
v) Interconnecting wiring/ piping.
vii) Grounding, support structures and platforms. | 2 | Set | - | - |
| 6 | 145kV, 1250A, single 3 –ph or three 1 – ph , Transformer feeder circuit breaker bay module, consisting of single 3 – or three 1 – SF6 gas insulated switchgears for 132/11KV transformer each comprising of:-
i) 1250A , One 3 – ph or three 1 – ph , SF6 gas insulated circuit breaker, complete with operating Mechanism. ii)Three, 4-core, single phase current transformers (250-150-100/0.577-1-1-1A)
iii) 1250A , One 3 – ph or three 1 – ph , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
iv) 1250A , One 3 – ph or three 1 – ph , single pole, group operated isolator/disconnector with one 3 – I or three 1 –I, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
v) 1250A , One 3 – ph or three 1 – ph , single pole, group operated isolator/disconnector with two earthing switches each comprising of one 3 – I or three 1 – I, single pole, group operated earthing switches complete with manual and motor driven operating mechanisms.
vi) GIS Bus Duct with gas monitoring device, pressure switch etc. as required.
viiTerminal boxes/Local Control Cubicle.
viii) Interconnecting wiring/ piping.
ix) Grounding, support structures and platforms. | 1 | Set | - | - |
| 7 | 145kV, 800A, single 3 – f or three 1 –f, Transmission line feeder circuit breaker bay modules, consisting of single 3 – f or three 1 –f SF6 gas insulated switchgears, each comprising of:-
800A, One 3 – f or three 1 –f, SF6 gas insulated circuit breaker, complete with operating mechanism for outgoing feeder.
Three, 3-core, single phase current transformers (600-300-150/1-1-1A).
800A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
800A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector with one, 3 – f or three 1 – f, single pole, group operated earthing switch, complete with manual and motor driven operating mechanisms.
800A, One 3 – f or three 1 – f, single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – f or three 1 – f, single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
Each GIS compartment with gas monitoring device, pressure switch etc. as required.
Terminal boxes/ Local Control Cubicle.
Interconnecting wiring/ pi
Grounding, support structures and platforms | 2 | Set | - | - |
| 8 | 66kV GIS:
The 72.5 kV SF6 gas insulated switch gear for three phase system shall have double bus bar arrangement with one line feeder bay to be connected with existing GIS System along with bus bar and jointing plugs/ adapter etc. The SF6 gas insulated switch gear rated for 66kV, 3-phase, 50 HZ, 31.5KA fault level shall be of the indoor metal-enclosed type, comprising of following items (presently Sieyuan make at substation).
72.5kV, 3150A, single 3 – or three 1 –, SF6 gas insulated, metal enclosed Bus bar arrangement, consisting of 2000A single 3 – or three 1 – SF6 gas insulated switchgears, each Bus Bar comprising of:-
i. Bus bar enclosures running the length of the switchgear to interconnect each of the circuit breaker bay modules in double main bus system.
ii. Jointing plugs/ adapters etc. as per site condition.
iii. Each GIS compartment with gas monitoring device, pressure switch etc. as required.
iv. Terminal boxes/ Local Control Cubicle.
v. Interconnecting wiring/ piping.
vi. Grounding, support structures and platforms. | 2 | set | - | - |
| 9 | 72.5kV, 2000A, single 3 – or three 1 –, Transmission line feeder circuit breaker bay modules, consisting of 2000A single 3 – or three 1 – SF6 gas insulated switchgears, each comprising of:-
i. 2000A, One 3 – or three 1 – , SF6 insulated circuit breaker, complete with operating mechanism.
ii. Three, 3- core, single phase current transformers (600-300-150/1-1-1A)
iii. 2000A, One 3 – or three 1 – , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
iv. 2000A, One 3 – or three 1 – , single pole, group operated isolator/disconnector without earthing switch, complete with manual and motor driven operating mechanisms.
v. 2000A, One 3 – or three 1 – , single pole, group operated isolator/disconnector with one normal and one high speed fault make 3 – or three 1 – , single pole, group operated earthing switches, complete with manual and motor driven operating mechanisms.
vi. Each GIS compartment with gas monitoring device, pressure switch etc. as required.
vii. Terminal boxes/ Local Control Cubicle.
viii. Interconnecting wiring/ piping.
ix. Grounding, support structures and platforms. | 1 | set | - | - |
| 10 | 220kV XLPE Copper cables (4x1CX1000mm2) to connect 220kV Transmission Line feeders with GIS. | 2,200 | Metres | - | - |
stage.html
html • 0.03 MB
technical_557715.pdf
techsummary_557715.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.89 MB
BOQ_557715.xls
BOQ • 0.78 MB
AD0138857.pdf
Additional Documents • 6.76 MB
OT0138857.pdf
Other Document • 25.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .