Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC 10TH MILE RISHI ROAD KALIMPONG DISTRICT DARJEELING PIN 734301 | KALIMPONG | DARJEELING | WEST BENGAL | 734301 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.9 L+₹29,597.50 (3.87%)Rejected-Finance | L2 | Rejected-Finance L1 Being Accepted | |
| 3 | L3₹8.1 L+₹42,697.50 (5.59%)Rejected-Finance | L3 | Rejected-Finance L1 Being Accepted | |
| 4 | L4₹8.1 L+₹50,135.61 (6.56%)Rejected-Finance | L4 | Rejected-Finance L1 Being Accepted | |
| 5 | L5₹8.3 L+₹65,459 (8.57%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L5 | Rejected-Finance L1 Being Accepted |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
23 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
REPAIRS TO LT DISTRIBUTION SYSTEM AND ALLIED WORKS IN ZONE A AND ZONE B AREA AT KALIMPONG UNDER GE 867 EWS
2021_MES_451156_3
CA NO GE / 867 / TOKEN / 24 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kalimpong
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹14,000
Yes
18 Sept 2021
10 Aug 2021
24 Aug 2021
10 Aug 2021
23 Aug 2021
18 Aug 2021
10 Aug 2021 - 14 Aug 2021
60 days
Amount
Material and labour for disconnection of electric cable from pole and bringing it to ground for cutting of damaged part of cable and putting insulation tape and reconnecting the same on exising pole after taking out additional cable from loop of the cable after excavation complete all as directed by Engr-in-Charge. Note:- Earth work and excavation shall be measured and paid seperately under respective items.
Material and labour for Load balancing of LT panel in all three phases of all outgoings complete with all as specified under:- (a) Taking of load of LT panel out going cables with the help of tong testing three times in a day to assess maximum unbalance of load. (b) To disconnect the LT cables/ TC wires and reconnect the same as per the load of the MCCB to balance the circuit. (c) Take the building wise load on the panel and make the load balance at bldg end.
Material and labour for cleaning of panel busbars and cable termination with the help of CRC spray, dismantling the cables from connections and reconnecting the same after cutting of damaged cable and relugging complete, tapping if required, cleaning the complete panel after disconnection from main supply and taking out of loop complete all as directed by Engr-in-Charge. Notes:- i) Contractor shall take proper shut down of panel from Power house before starting the work. ii) Earth work and excavation of cable shall be measured under respective items.
Laying only in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core/16 Sqmm 2 core/ 16 Sqmm 4 core / 25 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Laying only in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core / 50 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Laying only in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core / 95 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Laying only in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120/150 sqmm 3.5 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note for Item No. 4 to 7:- Cable shall be issued under sch 'B' free for laying. Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately.
Cutting and trimming tree branches any girth and any size and any number, touching to over head line and clearing the distance 2.5 mtrs both side of LT/HT over head conductors of span not exceeding 60m between poles and removing cut branches to a distance not exceeding 50m complete all as specified and directed by Engineer-in-Charge.
Supplying & erecting of steel tubular swaged pole conforming to IS, specification complete with MS base plate, finial taper plug, bolts, nuts, type 410 SP-31, 9.00 mtr long and painted internally two coats of bituminous paint through out and externally upto planting depth and painting external exposed surfaces with two coats of alluminium paint over one coat of redoxide primer including provision of black and yellow paint strips of 05 Nos of 30 cm wide strips or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of poles with writing letters or figures ( Block ), height minimum 10 cm & letters or figures n'exc 10 Nos for electric LT/HT/SL including clamp including taking out existing pole complete all as specified and directed by Engineer-in-Charge.
Taking out existing steel tubular swaged poles of any length including cross arms and shifing upto 2 Km and erecting truly in vertical position complete all as specified and directed by Engineer-in-Charge. Note for Item No. 9&10:Earth work, excavation, PCC foundation, PCC coping shall be measured and paid seperately.
Earhing complete with galvanized steel earth plate electrode 600X600X6 mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to GI earth strip of size 32x6mm, by means of galvanized iron or steel bolts, nuts, check nuts and washers, and conneced to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh charcoal or coke and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and suitable handle of 10 mm dia round bar, 40 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, 15 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
Restringing of existing LT overhead line for removing exessive sag including removing the existing binding wire and rebinding with new binding wire after tightning of overhead lines including disconnecting existing jumper and connections and reconnecting after tightning of conductor incl replacement of all jumpers all as directed by Engr -incharge. Notes: - (a) Single wire run of conductor in LT lines shall be measured as one lenght for payment purpose. (b) ACSR conductor shall be measured and paid separately.
M&L for Plain cement concrete 1:3:6 mix type C2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete etc., all as specified and directed by Engineer-in-Charge.
M & L Plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping including necessary formwork, weathering, slightly rounded or chamfered andgles, finishing of exposed surfaces of concrete to even and smooth without using extra cement all as specified and directed by Engr-in-charge.
Supply and fix 32 x 6mm galvanised iron strip as earth continuity conductor or main earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit pipe or fixed to poles or any other indicated situation for loop earthing etc., as required including taking down existing earth strip complete all as specified and directed by Engineer-in-Charge.
M&L for applying one coat aluminium paint on 9 mtr long steel tubler pole in position after prepretion of surface of steel tubler pole including all fitted cross arms, clamps and nut, bolts etc., including painting of black and yellow paint strips of 05 Nos of 30 cm wide strips or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level including numbering of size 70mmx40mm by using stencil to the pole with black synthetic enamel paint ( 1st grade ) 1.5 mtr above the ground level all as specified and as directed by Engineer-in-Charge.
Repairing of LT panel by means of replacing the hinge and locking arrangement of the existing panel, tightening the cable with bus bar by means of suitable lugs all as specified and as directed by Engr-in-charge.
Material and labour for spray painting to outdoor/Indoor type double door LT panels/Fedder pillar box incl angle iron stand with synthetic enamel paint after cleaning the surface thouroughly with scrapper including protecting/cleaning of cables, wiring and other non painted parts complete all as specified and as directed by Engr-in-charge.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from pole/panel/trench) indoor/outdoor termination end joint kit complete with jointing materials and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 4 Sqmm to 16 Sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from pole/panel/trench) indoor/outdoor termination end joint kit complete with jointing materials and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 Sqmm to 50 Sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from pole/panel/trench) indoor/outdoor termination end joint kit complete with jointing materials and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 Sqmm to 150 Sqmm complete all as specified and as directed by Engr-in-charge.
Supply and fix cable jointing kit in repairs of existing LT 1.1 KV grade cable disconnecting from site (by means of disconnecting from pole/panel/trench) Straight through termination kit complete with jointing materials and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 Sqmm to 16 Sqmm complete all as specified and as directed by Engr-in-charge. Make item No. 20 to 23: RAYCHEM/ 3M / M-SEAL
Material and labour for Stringing of existing stays after dismantling from pole and refixing the same after properly straightning of conductor complete all as specified and as directed by Engr-in-charge.
Material and labour for replacement of old unserviceable voltmeter/ Ammeter with Panel mounted multi function three phase digital energy meter of accuracy Cl-1.0 for measuring Voltage, Current, KW, KVAR, KWH, KVAH and power factor and making the disturbed surface good by welding/riveting in MS sheet 1.6 mm thick on the hollow portion duly painted and replacement of wiring if required complete all as directed by Engr-in-Charge. Make: Schneider EM6400 with RS 485 Port or equivalent in Siemens/L&T.
Material and labour for replacement of old unserviceable indicators any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same complete all as directed by Engr-in-Charge. Make: Legrand/ABB/Siemens
Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of 100/5A ratio, 5 VA incl connecting, disconnecting and testing complete all as directed by Engr-in-Charge.
Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of 160/5A ratio, 5 VA incl connecting, disconnecting and testing complete all as directed by Engr-in-Charge.
Supply, install, testing and commissioning in replacement LT Busbar Panel board Outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars (size 90 cmX90 cm X 45cm) duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X6 mm duly embedded in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and cable gland to incoming and outgoing cable with 2 hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5 in depth for taking out /laying of cable etc., and getting out in soft/loose soil.complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m and not exceeding 3m in depth for taking out /laying of cable etc., and getting out in hard/dense soil.complete all as specified and directed by Engineer-in-Charge.
Returning, filling in soil, including spreading leveling, watering and wall ramming in laying not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exe 50m and depositing where directed at alevel n.exe 1.5m above the starting point complete all as directed by Engineer - in -Charge.
Supply and spreading of dry sand in trenches for cable coushioning and punned down complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.
M&L for common burnt bricks, sub class 'B', of size 250 x 125 x 75 mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 4 core and connecting with necessary lugs including taking out exising unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note for Item No. 36 & 37:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Material and labour for 40 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge.
Material and labour for 25 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge. Make for iItem No. 38 & 39: OSWAL/BST/PRAKASH/JINDAL or equivalent as approved by GE.
S & F pin type insulator, porcelain, vitreous white/ brown or green including one galvanised mild steel spindle two GI washer and one GI nut 100mm height, 65mm dia for 1100 Volt grade including taking down existing insulator complete all as specified and directed by Engineer-in-Charge.
S & F Schakle type insulator, porcelain, vitreous white/ brown or green including galvanised mild steel straps of size 31 x 5 mm, washers insulator bolt of 14 mm dia and nuts complete of size 100 mm hight and 115mm dia of working pressure 1100 volts grade including taking down existing insulator complete all as specified and directed by Engineer-in-Charge. Make for iItem No. 40 & 41: (i) Jaipuria (ii) Jayshree (iii) Maysore Electric Industries (iv) Oblum
M&L for cross arms , bracings, supports, clamps and back plate fabricated from structural sections including nuts, bolts, and washer bending hot or cold , drilling holes for bolts of any size and painting with two coats of aluminum paint over one coat of red oxide primer including preparation of surfaces, including taking down existing cross arms etc., complete all as specified and directed by the Enginee-in-Charge.
M&L for Stay assembly with 20mm dia rod complete with accessories as shown in electrical plate No. 1 including taking out existing stay assembly, insulator complete all as specified and directed by the Enginee-in-Charge. Note: Loop type insulator, stay clamps, stay wire, excavation and concrete shall be measured and paid separately.
S & F loop type insulator, porcelain, vitreous white/ brown or green of size 90 x 140mm with clearence of hole 25.5 mm including taking down existing insulator complete all as specified and directed by Engineer-in-Charge.
M&L for galvanised stay strand 7/4mm as stay wire including binding etc., including taking down existing stay wire complete all as specified and directed by Engineer-in-Charge.
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 13,500.00 B/F from Ser page No. 28 NOTE: Bidder shall insert credit amount as rate Rs. 13,500.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
SANJAY SAW MILL
RAJU TAMANG
G K SUTHAR
S K ENTERPRISES
DEEP CHANDRA JOSHI
JAYSHREE CONCERN
Sri Gupta Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .