Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC 73 42 NONADANGA ROAD SHEORAPHULI HOOGHLY PIN 712223 | HOOGHLY | WEST BENGAL | 712223 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹6.1 L+₹48,839.96 (8.72%)Rejected-Finance F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | L2 | Rejected-Finance Being L2 Bidder | |
| 3 | L3₹6.4 L+₹75,595.87 (13.5%)Rejected-Finance | L3 | Rejected-Finance Being L3 Bidder |
| Sl No | Description | Qty | Unit | Snow Falls L1 | P. M. COOLING AND ENGINEERING CO L2 | M.S. COOLING & ENGINEERING CO. L3 |
|---|---|---|---|---|---|---|
| 1.00 | SITC of 2.2 ton capacity Hi-wall mount fixed speed split Air-conditioner machine fitted with tropical Rotary compressors suitable for Refrigerant-R32 cooling capacity-26400 Btr/hr, air flow-880of rated power supply 230 V-1 Ph- 50 Hz along with all accessories (Make-Daikin model no FTKL71UV16T or Hitachi or equivalent make approved by EIC). incl. Supply & fixing required Angle Iron Structure on wall & mending works as per direction of E.I.C. (Executive chamber.) (one existing old 2T at EE chamber will be refixed at top fl accounts and cash sec.) | 1 | Item | 55,000 ₹55,000 Lowest | 62,500 ₹62,500 | 65,300 ₹65,300 |
| 2.00 | SITC of 2.0 ton capacity Hi-wall mount fixed speed split Air-conditioner machine fitted with tropical Rotary compressors suitable for Refrigerant-R32 cooling capacity-24000 Btr/hr, air flow-800of rated power supply 230 V-1 Ph- 50 Hz along with all accessories (Make-Hitachi model no Shizen RMRG324HFEOZ1 or Daikin or equivalent make approved by EIC). incl. Supply & fixing required Angle Iron Structure on wall & mending works as per direction of E.I.C. (one existing old 2T will be refixed at top fl accounts and cash sec.) | 2 | Item | 45,000 ₹90,000 Lowest | 50,500 ₹1,01,000 | 52,300 ₹1,04,600 |
| 3.00 | SITC of 1.5 ton capacity Hi-wall mount fixed speed split Air-conditioner machine fitted with Rotary compressors suitable for Refrigerant-R32A cooling capacity-18000 Btr/hr, air flow-600 having PCB in metal enclosure on wall using angle iron frame incl. charging the refregerent as per direction of EIC. (Make-Hitachi model Shizen RSQG318HFEOF or Daikin or equivalent model of as approve by the E.I.C.) General section, Estimating section, Accountant chamber | 4 | Item | 35,000 ₹1,40,000 Lowest | 37,000 ₹1,48,000 | 38,000 ₹1,52,000 |
| 4.00 | SITC of 1.0 ton capacity Hi-wall mount fixed speed split Air-conditioner machine fitted with Rotary compressors suitable for Refrigerant-R32A cooling capacity-12000 Btr/hr, air flow-400 having PCB in metal enclosure on wall using angle iron frame incl. charging the refregerent as per direction of EIC. (Make- HITACHI Shizen RAPG312HFEOZ1 or Daikin or equivalent modelc as approve by the E.I.C.) (H/C chamber) | 5 | Item | 27,000 ₹1,35,000 Lowest | 33,000 ₹1,65,000 | 34,500 ₹1,72,500 |
| 5.00 | Supply & Laying Extra Add-on items- 5/8" (for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation, 4 core x 2.5 sq.mm. copper cable incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for 1.5 TR / 2 TR A.C. Machine. and Supply & laying PVC Drain Pipe 25mm dia by shaddling on wall incl. PVC "T", elbow, bend etc as per direction of E.I.C | 60 | Mtr. | 300 ₹18,000 | 250 ₹15,000 Lowest | 350 ₹21,000 |
| 6.00 | Supplying, fabrication & fixing 2 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m length for making Base frame for installation of AC ODU incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm of 1.5m length as per direction of E.I.C incl. Platforn. | 6 | nos | 4,020 ₹24,120 | 1,800 ₹10,800 | 1,500 ₹9,000 Lowest |
| 7.00 | S&F of 25mm Dia UPVC pipe for AC drain pipe on wall, ceiling with saddles and other accessories as required and mending good damages to building works | 80 | Mtr. | 50 ₹4,000 Lowest | 50 ₹4,000 Lowest | 65 ₹5,200 |
| 8.00 | Dismantling indoor and outdoor unit, cu pipe of the existing 2T A/C from EE chamber with care | 1 | Item | 1,200 ₹1,200 | 1,000 ₹1,000 | 850 ₹850 Lowest |
| 9.00 | Refixing the dismantled 2T A/C at Accounts section | 1 | Item | 2,500 ₹2,500 Lowest | 3,500 ₹3,500 | 2,800 ₹2,800 |
| 10.00 | TERMS AND CONDITION
1. THE AGENCY MUST PROCURE THE MATERIALS FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES. SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT OF THE MANUFACTURER / OEM BECOMES APPLICABLE TO THE PRODUCTS TO BE DELIVERED AND INSTALLED BY THEM.
2. DOCUMENTS THAT AUTHENTICATES SUCH PROCUREMENT FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT SHOULD BE SENT FROM THE e-MALE OF THE MANUFACTURER/OEM / AUTHORIZES SALES CHANNEL TO THE e-MALE OF ENGINEER-IN-CHARGE AND HARD COPY OF IT TO BE SUBMITTED DURING EXECUTION OF WORK/ SUBMISSION OF BILL.
3. IF ANY REFURBISHED MATERIAL IS SIPPLIED ABD INSTALLED, PENAL ACTION WILL BE TAKEN AS PER EXISTING RULES. | - | - | - | - | - |
Tender Value
Refer Docs
EMD Value
₹12,500
Closing Date
23 Oct 2023, 2:00 pmClosed
The Executive Engineer, PWD, Hooghly Ele
Office of The Executive Engineer, PWD, Hooghly Electrical Division,PWD
Upgradation of Haripal Rural Hospital in the district of Hooghly...installation of AC machine at Hooghly Construction Division P.W.Dte.
2023_WBPWD_587350_1
WBPWD/EE/ HED / NIeT-22/of 2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
HOOGHLY
Please refer Tender documents.
4 documents required · 4 mandatory
₹12,500
Office of The Executive Engineer, PWD, Hooghly Ele
10 Sept 2026
6 Oct 2023
30 Oct 2023
6 Oct 2023
23 Oct 2023
6 Oct 2023
10 Oct 2023
Amount
SITC of 2.2 ton capacity Hi-wall mount fixed speed split Air-conditioner machine fitted with tropical Rotary compressors suitable for Refrigerant-R32 cooling capacity-26400 Btr/hr, air flow-880of rated power supply 230 V-1 Ph- 50 Hz along with all accessories (Make-Daikin model no FTKL71UV16T or Hitachi or equivalent make approved by EIC). incl. Supply & fixing required Angle Iron Structure on wall & mending works as per direction of E.I.C. (Executive chamber.) (one existing old 2T at EE chamber will be refixed at top fl accounts and cash sec.)
SITC of 2.0 ton capacity Hi-wall mount fixed speed split Air-conditioner machine fitted with tropical Rotary compressors suitable for Refrigerant-R32 cooling capacity-24000 Btr/hr, air flow-800of rated power supply 230 V-1 Ph- 50 Hz along with all accessories (Make-Hitachi model no Shizen RMRG324HFEOZ1 or Daikin or equivalent make approved by EIC). incl. Supply & fixing required Angle Iron Structure on wall & mending works as per direction of E.I.C. (one existing old 2T will be refixed at top fl accounts and cash sec.)
SITC of 1.5 ton capacity Hi-wall mount fixed speed split Air-conditioner machine fitted with Rotary compressors suitable for Refrigerant-R32A cooling capacity-18000 Btr/hr, air flow-600 having PCB in metal enclosure on wall using angle iron frame incl. charging the refregerent as per direction of EIC. (Make-Hitachi model Shizen RSQG318HFEOF or Daikin or equivalent model of as approve by the E.I.C.) General section, Estimating section, Accountant chamber
SITC of 1.0 ton capacity Hi-wall mount fixed speed split Air-conditioner machine fitted with Rotary compressors suitable for Refrigerant-R32A cooling capacity-12000 Btr/hr, air flow-400 having PCB in metal enclosure on wall using angle iron frame incl. charging the refregerent as per direction of EIC. (Make- HITACHI Shizen RAPG312HFEOZ1 or Daikin or equivalent modelc as approve by the E.I.C.) (H/C chamber)
Supply & Laying Extra Add-on items- 5/8" (for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation, 4 core x 2.5 sq.mm. copper cable incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for 1.5 TR / 2 TR A.C. Machine. and Supply & laying PVC Drain Pipe 25mm dia by shaddling on wall incl. PVC "T", elbow, bend etc as per direction of E.I.C
Supplying, fabrication & fixing 2 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m length for making Base frame for installation of AC ODU incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm of 1.5m length as per direction of E.I.C incl. Platforn.
S&F of 25mm Dia UPVC pipe for AC drain pipe on wall, ceiling with saddles and other accessories as required and mending good damages to building works
Dismantling indoor and outdoor unit, cu pipe of the existing 2T A/C from EE chamber with care
Refixing the dismantled 2T A/C at Accounts section
TERMS AND CONDITION 1. THE AGENCY MUST PROCURE THE MATERIALS FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES. SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT OF THE MANUFACTURER / OEM BECOMES APPLICABLE TO THE PRODUCTS TO BE DELIVERED AND INSTALLED BY THEM. 2. DOCUMENTS THAT AUTHENTICATES SUCH PROCUREMENT FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT SHOULD BE SENT FROM THE e-MALE OF THE MANUFACTURER/OEM / AUTHORIZES SALES CHANNEL TO THE e-MALE OF ENGINEER-IN-CHARGE AND HARD COPY OF IT TO BE SUBMITTED DURING EXECUTION OF WORK/ SUBMISSION OF BILL. 3. IF ANY REFURBISHED MATERIAL IS SIPPLIED ABD INSTALLED, PENAL ACTION WILL BE TAKEN AS PER EXISTING RULES.
Add GST @18% Rs.
Add LWC @1% Rs.
P. M. COOLING AND ENGINEERING CO
M.S. COOLING & ENGINEERING CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .