Ex. Engineer RnB Electric Hospital Division Kmr
Rajbagh, Srinagar
Supply, installation, testing and commissioning (SITC) of Firefighting Detection / Alarm System with other Civil and Electrical Works at SKIMS Soura
2026_PWDJK_321256_1
eNIT No. HDE 31 of 2026_27 dated 17_08_2026
Open Tender
Network /Communication Equipments
Percentage
90 days
SKIMS Soura
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Ex. Engineer RnB Electric Hospital Division Kmr
₹5.3 L
Ex. Engineer RnB Electric Hospital Division Sgr
18 Aug 2026
18 Aug 2026
8 Sept 2026
18 Aug 2026
7 Sept 2026
18 Aug 2026
24 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with suitable Loops modules with hot plugabale loop cards and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, redundancy feature at CPU level, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories . EN54 & VDS / UL & FM Certification.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica | - | - | - | - |
| 2 | 2 Loop Panel Expandable upto 4 Loops | 6 | Nos. | 3,93,250 | ₹23,59,500 |
| 3 | 4 Loop Panel Expandable upto 10 Loops | 1 | Nos. | 6,40,200 | ₹6,40,200 |
| 4 | 6 Loop Panel Expandable upto 20 Loops | 1 | Nos. | 8,51,400 | ₹8,51,400 |
| 5 | Supply, Installation, Testing and Commissioning of Active and networkable repeater panel with 4x20 character LCD display complete system function keys for programming and control like system reset, alarm acknowledgement, alarm silence, trouble acknowledgement etc. EN54 & VDS / UL & FM Certification.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica | 11 | Nos. | 1,51,800 | ₹16,69,800 |
| 6 | Supply, Installation, Testing and Commissioning of addressable multisensor smoke/Heat detector including mounting base with LED etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. EN54 & VDS / UL & FM Certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica | 2,286 | Nos. | 5,610 | ₹1,28,24,460 |
| 7 | Supply, Installation, Testing and Commissioning of Addressable Heat Detectors with combination of fixed type and rate of rise of temperature feature. Detetctor should have inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54 & VDS/ UL & FM Certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica | 31 | Nos. | 5,410 | ₹1,67,710 |
| 8 | Supply, Installation, Testing and Commissioning of Intelligent Addressable smoke detector works based on Dual-Ray technology with two integrated light-scattering smoke sensors using 2 LEDs - blue & infrared. (Detector should comply to Test Fire 1). Detetctor should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements and have an option of both soft & hard addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. EN54 &VDS/ UL & FM certification.(Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica | 14 | Nos. | 11,715 | ₹1,64,010 |
| 9 | Supply, Installation, Testing and Commissioning of addressable Flush mounted type Ultra slim Invisible smoke detector including mounting base, auto addressing feauture as required. Detetctor should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements.In addition the detectors are suitable for areas with heightened dust exposure, High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54 & VDS/ UL & FM Certification (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector).Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica | 30 | Nos. | 21,402 | ₹6,42,060 |
| 10 | Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements & with flexible network structures with a maximun switching current of 1A @ 30V DC. EN54 & VDS / UL & FM Certification.Approved makes-Sinteso by Siemens, BOSCH,Simplex by Johnson Controls, Gamewell, Autronica | 36 | Nos. | 5,843 | ₹2,10,348 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.15 MB
BOQ_1072059.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].