Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹16.8 L+₹28,876 (1.75%)Rejected-Finance | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹17.5 L+₹98,746 (5.97%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest bidder | |
| 4 | L4₹18.0 L+₹1.5 L (8.96%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L4 | Rejected-Finance Rejected being not lowest bidder | |
| 5 | L5₹20.7 L+₹4.1 L (25.0%)Rejected-Finance | L5 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹25.7 L
EMD Value
₹51,500
Closing Date
12 Dec 2019, 5:00 pmClosed
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
SPL REPAIRS TO FLOORING- TILING- INTERNAL ELECTRIC FITTING TO BARRACK NO 2 ME LINE UNDER AGE BR-I OF GE CENTRAL KIRKEE.
2019_MES_296938_1
CWE/KKE/39 OF 2019-20
Open Tender
Civil Works - Others
Item Rate
180 days
GE Central Kirkee
Class D cat a(i)
5 documents required · 5 mandatory
₹500
Yes
GE Central Kirkee
₹51,500
Yes
15 Jan 2020
11 Nov 2019
13 Dec 2019
11 Nov 2019
12 Dec 2019
27 Nov 2019
11 Nov 2019 - 21 Nov 2019
Amount
Dismantling floor hearth or wall tiling incl cement mortar bedding (but not backing) removing servicable tiles to store and rubbish off the permises.
M & L for 25 mm thick PCC 1:2:4 type B-1 using 20mm crushed stone aggregate as in leveling course complete.
M & L for non skid ceramic coloured tiles, 7 to 8 mm thick (square or rectangular) area of each tile exe 0.11 Sqm but n.exe 0.18 Sqm, laid in floors set and jointed with neat cement slurry including screed bed or bedding layer of mortar 15 mm thick average thickness for laying floor finishes in cement mortar (1:4) and pointing in white cement with pigment to match the shade of tiles, complete all as specified.
Taking down chowkhats or frames of any description exceeding 1.5 Sqm but not exceeding 4.0 Sqm and resecuring, easing , adjusting and re-fixing in same opening complete all as specified and as directed by engr-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe/electric cables and getting out in soft loose soil complete all as specified.
Returning filling in including spreading levelling watering & well ramming in layers n.exc. 25 cm thick in soil
Removal of excavated material n. exc. 50 m and deposited where directed at a leveln. exc 1.5 m above the starting point all as directed by Engr-in-Charge
Supply and lay LT UG cable 2 core 6 sqmm XLPE insulated sheathed armoured 1100 volts grade laid in trenches complete incl indoor/ out door joint all as directed and specified.
Supply and lay LT UG cable 3.5 core 35 sqmm XLPE insulated sheathed armoured 1100 volts grade laid in trenches complete incl indoor/ out door joint all as directed and specified.
Material and labour for dry sand cushioning to underground cables in trenches including spreading, levelling, hand punning and consolidating, complete all as specified and directed. Note : Punned thickness of sand shall be measured and paid.
M & L for reinforced precast concrete cable cover class LV type -1 flat of size 250mm x 150mm x 40 mm for cable protection all as specified and directed by Engr-in-Charge.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismantling and taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket incl dismantling and taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16 amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket incl dismantling and taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismantling and taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismantling and taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
S&F 5 Amp switch piano type single pole one way incl dismantling and taking down unsv one all as specified and as directed
S&F socket flush type 6 amps, 5 pin, 230v incl dismantling and taking down unsv one all as specified and as directed
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismantling and taking down unsv one all as specified and as directed
S&F ceiling rose surface Bakelite three terminal all incl dismantling and taking down unsv one as specified and as directed
S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz incl dismantling and taking down unsv one all as specified and as directed
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismantling and taking down unsv one all as specified and directed. MAKE- Cat Part No- 6077 11 of Legrand or equivalent of Schneider/ABB
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismantling and taking down unsv one all as specified and directed. MAKE- Cat Part No- 6077 15 of Legrand or equivalent of Schneider/ABB
S&F MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismantling and taking down unsv one all as specified and directed. MAKE- Cat Part No- A9N4P40C to A9N4P63C of Schneider or equivalent of Legrand/ABB
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling and taking down unsv one all as specified and directed. MAKE- Cat Part No- A9N1P06C to A9N1P32C of Schneider or equivalent of Legrand/ABB
S&F MCB, Double Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling and taking down unsv one all as specified and directed. MAKE- Cat Part No- A9N2P06C to A9N2P32C of Schneider or equivalent of Legrand/ABB
S&F in repairs ceiling fan of 1200 mm sweep complete incl fan suitable fan road with suitable clamp, nut, bolt & washers all as specified and directed
S&F in repairs Exhaust fan Metal body light duty 300 mm sweep complete with grill, Make- Havells, cat Part No-Vent air-DS 9.9 (New Provision)/USHA/CG/BAJAJ.
S&F LED Tube light fitting, 18 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos any type incl dismantling and taking down unsv one all as specified and directed. Make-HPL, Cat Part No Pheonix Plus HPLLEDT1818 (CW) or equivalemt in Havells/Bajaj/Philips/CG
S&F LED Tube light fitting, 9 watt, CDL, 230 Volts, 2 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos any type incl dismantling and taking down unsv one all as specified and directed. Make-HPL, Cat Part No Pheonix Plus HPLLEDT0909 (CW) or equivalemt in Havells/Bajaj/Philips/CG/HPL
S&F LED building security light 15 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener all as specified and directed. Make-HPL, Cat Part No HPLLEDST1560N or equivalent in Philips/Bajaj/CG
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
Supply only PVC insulated, PVC sheathed twin flat core 1100 volts grade, 2.5 sqmm aluminium stranded conductor from junction box to street/security/post top luminaries all as specified and directed.
Supply and Supply and fixing service bracket including fixing arrangement complete all as directed and specified.
S&F LED street light fitting 45 watt, CDL, pressure die-cast aluminium alloy for housing (heat sink) with exposy powder coated with high efficiency long life LED chip inbuilt with electronic driver with APFC including connection from OH line. Make-CG , Cat No- LSTP-45-CDL, or equivelent of Philips/ Wipro/Bajaj/Osram (NOTE: CONNECTION WIRE MEASURED SEPARATELY)
S&F SMC pole mounted box of size 10"x8"x4" with hinged door product code GSJB-2520 Make Synthectic or equivqlent of Hansal / Presfit complete with following acessories (a) Din rail mounting of MCB DP - 01 no (b) Connector block 3 phase 4 wire minimum 16 amps cable -01 No including complete fixing arrangement.
greenstone construction
Om Construction
JP ENTERPRISES
V.R.PRAJAPATI AND CO.
C J Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .