Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC 227 2 5TH B MAIN ROAD 2ND BLOCK HRBR LAYOUT KALYAN NAGAR BANASAWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹28.8 L Quoted ₹29.4 L | L1 | Accepted-AOC Lowest Bid Value. |
| 2 | L2₹29.5 L+₹12,383.20 (0.42%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹29.5 L+₹12,383.20 (0.42%) | L2 | Rejected-AOC Higher Bid Value. |
| 3 | L3₹29.9 L+₹51,043.20 (1.74%)Rejected-AOC NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | ₹29.9 L+₹51,043.20 (1.74%) | L3 | Rejected-AOC Higher Bid Value. |
| 4 | L4₹30.0 L+₹57,903.20 (1.97%)Rejected-AOC | ₹30.0 L+₹57,903.20 (1.97%) | L4 | Rejected-AOC Higher Bid Value. |
| 5 | L5₹37.1 L+₹7.8 L (26.4%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | ₹37.1 L+₹7.8 L (26.4%) | L5 | Rejected-AOC Higher Bid Value. |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
22 Dec 2020, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE HQ TC AIR FORCE BANGALORE 560006
REPAIR/REPLACEMENT OF FEEDER PILLAR BOX/BUSHER/ CHAMBER/ LT PANEL/EARTHING AND LT UG CABLE/LT OUTDOOR PANELS/ E/M INSTALLATION DG SET INSTALLATION AND CONNECTED WORKS AT HQ TC BANGALORE
2020_MES_397875_1
8724/GE-57
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) BANGALORE
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE (AF) BANGALORE
₹78,000
Yes
22 Jan 2021
24 Nov 2020
24 Dec 2020
24 Nov 2020
22 Dec 2020
8 Dec 2020
25 Nov 2020 - 1 Dec 2020
Amount
Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in hard/dense soil for laying of cable trenches all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm all as specified.
Removal of surplus soil (excavated soil) to distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point and all specified.
Taking out old underground cable of any size and any core including all fittings all as speciifed and as directed. Note : good conditioned bricks , PCC covers will be kept aside and duly stacked for reuse and will be measured under respective item of schedule.
Supply and Laying of cable XLPE insulated screened PVC bedded, galavanised steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following sizes :-
(a) 300 sqmm 3.5 core.
(b) 240 sqmm 3.5 core.
(c) 185 sqmm 3.5 core.
(d) 120 sqmm 3.5 core.
(e) 95 sqmm 3.5 core.
(f) 70 sqmm 3.5 core.
(g) 50 sqmm 3.5 core.
(h) 35 sqmm 3.5 core.
(j) 25 sqmm 4 core.
(k) 16 sqmm 4 core.
(l) 10 Sqmm 2 core
Supply and spread dry clean river sand in trenches for cable cushioning all as directed and specified.
Supplying and laying un-reinforced precast concrets cable cover class LV Type 1 flat size 250x150x40 MM
Laying only bricks , PCC covers removed from srl item No 4 above for protection of UG cables all as directed .
Supply & lay common burnt clay building bricks for UG cable protection sub-class'B' of designation 75 of standard size modular bricks laid dry in trenches as directed and specified.
M & L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 110mm dia suitable for 0.4mpa working pressure.
M & L for GI tubing 'Light' grade for cable protection fixed in poles/walls/laid under roads/crossing etc incl taking out the rusted pipes of following sizes and all as specified and directed :-.
(a) 100mm bore
(b) 80mm bore
(c) 50mm bore
(d) 40mm bore
Labour for taking out the unserviceable / faulty cable after meggering , finding the fault , cutting the cable , jointing with jointing kit using extra cable if required ,relaying of of cables of any size & core,connecting complete all as specified and as directed. Note : Excavation , earthwork , sand for cushioning , PCC covers , GI pipe ,cable , cable joints will be measured and paid seperatly under respectrive item of schedule.
Supply and fixing of Straight through joints (Heat Shrink Kits) for LT underground cable complete for Armoured ,PVC sheathed Aluminium conductor cables by excavating earth, identifying the fault, making proper joint of cable after rectification & returning soil back to earth all as specified and as directed for the following sizes:-
(a) 3.5 core cable 25 to 50 Sq mm.
(b) 3.5 core cable 70 to 150 Sq mm
(c) 3.5 core cable 150 to 300 Sq mm
Supply and fixing of End termination indoor / outdoor joints (Heat Shrink Kits) for LT underground cable complete for Armoured ,PVC sheathed Aluminium conductor cables including takingout damaged joints, connecting and testing all as specified and as directed for the following sizes:-
(a) 3.5 core cable 150 to 185 Sq mm
(b) 3.5 core cable 240 Sq mm
(c )3.5 core cable 400 Sq mm
Supply & Fix MCB TPN 63A "C" curve, 415V,10KA breaking capacity incl taking down unserviceable MCB all as directed.
S & F MCCBs Triple pole 16KA, fixed type incl taking out unserviceable MCCB's and connecting complete all as speciifed and as directed of following capacities :-
(a) 25 to 100 Amps
(b)125 Amps
S & F MCCBs Triple pole 36KA, adjustable type incl taking out unserviceable MCCB's and connecting complete all as speciifed and as directed of following capacities :-
(a) 160 Amps
(b) 200 Amps
(c) 250 Amps
Supply & Fix MCCB 4 pole adjustable type 63-100 Amps, 25 kA ,including taking down old MCCB all as directed.
Supply & Fix busbar chamber (Al busbar-4 Nos)63 Amps , 8 way , 415 volts including taking down old busbar complete all as directed. Make : Standard, Cat No ISBC006308 or equivalent.
Material & Labour for servicing, cleaning, dusting of indoor LT Panel board incl carrying out necessary repair to the existing panel , replaceing the unserviceable spares , welding the damage doors, replacing the old rusted frames incl painting the panel withone coat of approved colour over a coat of red oxide primer also connecting up the cables all as specified & directed
--All--- as srl item No 20 above but for outdoor LT feeder pillar box of any sizes all as specified and as directed.
Weather proof busbar chamber 600x450x300MM made out of 2 MM thick CRCA steel sheet & 40x5 MM angle iron frame suitable for mounting 1 mtr above ground level with locking arrangements incl. Provn of 4 Nos aluminium busbar of 200 Amps rating mounted on insulated frames 2 Nos incl. connecting up incoming & outgoing cables complete with glands,llugs incl.painted with two coats of powder coated paint over a coat of red oxide primer, including neessary earthwork , mass PCC all as specified & directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S.clamps, bolts and nuts of approved size, for LT, 20x15cm size.
Supply only Digital type Frequency meter , class 0.2 all as speciifed and as directed.
Supply only Curent transformer 200/5A , accuracy class 1.0 , burden 10 VA burden, resin cast wound type all as speciifed and as directed.
-all-- as per srl item No 26 above but 100/5A , 5 VA burden all as specifed and as directed.
Supply only indicator lamps (LED Type) including taking down unserviceable indicator lampsall as speciifed and as directed.
Supply and fixing of ON LOAD Change Over switch front handle operated 415V 50hz four pole all open execution type in replacement of old unserviceable switches all as directed.
(a)125 Amps
(b) 200 Amps
(c ) 400 Amps
Material and labour for Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground ( earth pit not less than 2.25mtrs deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level, connected to galvanised iron strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indiacted including testing on completion.
Scraping the peeled out paint of the LT panels , feeder pillar boxs , preparing the outer surfacse ,applying metal paste on the voids to make the surface even, spray painting with one coat of synetic enamel paint of existing shade and sign writing of locations / feeders etc all as directed.
Supply and fix capacitors metalized poly propylene heavy duty (MPP-H) for 3 phase 440V , 50 Hz system for permissible non-linear load of 5 to 15 kVAr rating including taking down unserviceable capacitor all as directed.
Supply and fix capacitors metalized poly propylene heavy duty (MPP-H) for 3 phase 440V , 50 Hz system for permissible non-linear load of 20 to 25 kVAr rating including taking down unserviceable capacitor all as directed.
Supply and Fix power contactor 3 pole MNX 25, 415 volts , 50HZ including dismantling the unserviceable contactor all as directed.
All as srl item No 34 above but MNX 45 kVAr all as directed.
All as srl item No 34 above but MNX 70 kVAr all as directed.
Supply and Fix in replacement Add on auxulary contact block suitable for MNX type existing contactors all as directed.
S & F LT cubical, floor mounted pedestal indoor type made out of steel sheet enclosure 3mm thick CRCA sheet factorymade dust ,vermin proof floor mounting type suitable to operating on 3 phase 415 volts 50Hz AC supply duly painted with powder coated paint including the following :- (i) MCCB 4 pole 400 Amps , 35 kA -01 No Incoming ii) MCCB 3 pole 200 Amps 25kA - 04 No out going . (iii) MCB TPN 32 Amps-02 Nos (iv) MCB SPN 16 Amps -04 Nos (v) Aluminium bus bars 3 phase and neutral 600 Amps capacity -01 set (iv) 3 phase Digital voltmeter -01 No (vii) 3 p-hase Digital ammeter with CT's 200/5 Amps - 01 Nos (viii) phase indication lamps LED-01 set (ix) On LOad Change Over Switch 4 pole, 200 Amps -01 No (x) provision for Incoming & outgoing cables with gland plates as required.
Supply and Fix power contactor 3 pole Type ML-3, AC3 rating 40A, 50HZ including dismantling the unserviceable contactor all as specified and as directed.
Supply and Fix power contactor 3 pole Type MO-18, AC3 rating 18A, 50HZ including dismantling the unserviceable contactor all as specified and as directed.
Supply and Fix digital time switch programmable, current capacity 16A mps DIN type with 1 changeover incl takingout the unserviceable time switches connecting & testing complete all as speciifed and as directed. Make Legrand / L&T / Indo asian.
S & F Digital type Volt meter , 3 ph , class 1 including taking down unserviceable voltmeter all as specifed and as directed.
S & F Digital type Ammeter 3 ph , 5 Amps , class 1 including taking down unserviceable ammeter all as speciifed and as directed.
devan enterprises
Shanthi Construction
SREE VARU ELECTRICALS
RRK PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .