Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being lowest bid. | |
| 2 | L2₹35.5 L+₹3.9 L (12.5%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid. | |
| 3 | L3₹36.7 L+₹5.1 L (16.2%)Rejected-Finance H NO B III 95 MOHALLA GHARTHOLI MISSION ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than lowest bid. |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
19 Dec 2022, 6:00 pmClosed
GE (SOUTH) MAMUN
GE (SOUTH) MAMUN PATHANKOT-145001
REPAIR AND MAINT OF WATER SUPPLY INSTALLATIONS LT PANELS, MOTOR STARTERS AND ALLIED WORKS, REPAIR AND REPLACEMENT OF SECURITY LIGHTS, LED FLOOD LIGHTS ALONGWITH DAMAGED LT CABLES AND ITS CONNECTED ITEMS AT 1ST HORSE AND GOC AREA AND REPAIR AND MAINT
2022_MES_564494_1
GE(S)/M-49/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (SOUTH) MAMUN
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (SOUTH) MAMUN
₹78,000
Yes
7 Jan 2023
22 Nov 2022
26 Dec 2022
22 Nov 2022
19 Dec 2022
6 Dec 2022
Amount
Supply and fixing in replacement GI bracket for street light fitting made out of 40mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole and street light and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint complete all as specified and directed.
Supply and fixing in replacement GI bracket for street light fitting made out of 25mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole and street light and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint complete all as specified and directed.
Supply and fixing in replacement of 45W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing in replacement of 60W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing in replacement of 70/72W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing and testing of 150W LED Flood light luminaire after taking down UNSV flood light abd deposited to MES yard, shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life with excellent illumination and instant light with low tempreture (-10 degree to +50 degree). The luminaire shall be complete available CCT 5700K IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED flood light should be top maintainable for easy maintenance.LED flood light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Flood Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Flood Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing in replacement of 35W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Supply and fixing in replacement of post top lantern 40 watts 230 volts, 50 Hz mushroom or oval shaped in sothing opal/prismatic finish made up of polycarbonate, suitable for 36/40 Watt LED, including all accessories including fixing arrangement by providing GI pipe of suitable size and length, prewired The LED Street Light shall have power factor more than 0.95 complete all as specified and directed.
Note for srl item No 3 to 8 above 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. 11. CA No. shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintenance required, if any can be carried out from top cover and IP-66 protection certificate issued for manufacture.
M&L in replacement for stay assembly comprising stay 14 mm dia and 40 cm long stay rod 20 mm dia and 1.8 m long threaded ends with nuts, mild steel plate 30 cm X 30 cm X 6 mm thick and two number of thimble etc. complete with accessories as shown in electrical plate No. 1 of SSR Part-I of 2009 including taking down existing stay assembly complete all as specified and directed. Note:- Loop type insulator, stay clamps, excavation & earh work and concrete shall be measured and paid separately.
M&L for galvanized steel stay wire size 7/ 4.0 mm for stay of poles complete all as specified and directed.
M&L for loop type insulator vitreous, poecelain, white/brown/green, large size, with overall dimensions 65 x90 mm, clearance of hole 16 mm complete all as specified and directed.
S&F as in repalcement of industrial switchgear busbar chambers of size 600x600x150mm of 200Amp, 6 way for LT cable any size including necessary PCC/Wall mounting work, cable gland, complete all as specified and directed.
Supply and fixing in replacement of old unserviceable copper conductor cable three core PVC insulated and sheathed copper conductor cable of size 1.5 sqmm down through the existing pole/GI pipe bracket complete all as specified and directed.
S&F as in replacement digital display astronomical time switch to control various lighting loads according to sunrise and sunset time of current cap rating 16 A AC1 with USB key, 1 change over including backup of 6 year and use of USB key for program download and upload daily, weekly, program complete all as specified and directed.
Supply and fixing in replacement contactor four pole 63 Amps with operating coil voltage 230V with manual operation knob in case of coil failure conforming to cat Part No ETC 463, including suitable size and capacity copper cable and making necessary connections using appropriate copper bus bar or PVC insulated cable with copper conductor and lugs as requiared at site complete all as specified and directed.
S&F in replacement optimum adjustable range MCCB FP 415 volts, IEC 60947-II 63 Amps rating with rupturing capacity 25 KA including providing thimble for out going cables and taking out unserviceable MCCB FP of any deccription / type etc. complete from LT Panel, complete all as specified and directed.
S&F in replacement optimum adjustable range MCCB FP 415 volts, 100 Amps rating with rupturing capacity 25 KA including providing thimble for out going cables and taking out unserviceable MCCB FP of any deccription / type etc. complete from LT Panel, complete all as specified and directed.
Supplying, jointing and connecting in replacement cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting in replacement cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting in replacement cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting in replacement cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 95 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
S&F in replacement cable of size 10 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminiun conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspended with galavnised steel wire, complete all as specified and directed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes,for cable and pole, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and exc. 1.5 m but n. exc. 3 m in depth, for foundation, etc. or for shafts, wells for pole, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and getting out complete all as specified and directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. Note:- Volume of pole/strut shall be deducted for the purpose of payment.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in pedestal/coping including necessary weathering and form work etc complete all as specified and directed. Note:- Volume of pole/strut shall be deducted for the purpose of payment.
M&L for dry clean fine river sand as in sand cushioning to underground cable 8cm below and 15cm above the cable including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 16 Sqmm x 2 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
All as per srl item No 30 here-in-before, but cable of size 16 Sqmm x 4 core complete all as specified and directed.
All as per srl item No 30 here-in-before, but cable of size 25 Sqmm x 4.0 core complete all as specified and directed.
All as per srl item No 30 here-in-before, but cable of size 50 Sqmm x 3.5 core complete all as specified and directed.
All as per srl item No 30 here-in-before, but cable of size 70 Sqmm x 3.5 core complete all as specified and directed.
All as per srl item No 30 here-in-before, but cable of size 95 Sqmm x 3.5 core complete all as specified and directed.
Supply and fixing in replacement GI tubing light grade 40 mm bore cut to size and fixed along the pole for cable protection including MS clamp 02 Nos of size 25x4 mm, nut bolts , washers etc complete all as specified and directed.
Supply and fixing in replacement GI tubing light grade 80 mm bore cut to size and fixed along the pole or laid in ground for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc complete all as specified and directed.
Dismantling PCC or steel pole and demolition of PCC, including necessary earth work complete all as specified and directed.
M&L for scraping of old paint from the steel tubular pole 9 Mtr height with out removing accessories, preparation of surfaces repainting the pole with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamel paint. Marking the pole number with black enamel paint over yellow circle of dia 100mm. Repainting the remaining pole and iron parts i.e 'U' clamps, channels etc above 1.5 mtr height by applying one coat of alumnium paint, complete all as specified and directed.
S&F in replacement electronic LED street light driver ISI marked as approved by Engr-in-charge suitable for LED fittings of cap upto 60 watts any type and make and matching make to existing make of street light, after taking down the street light and refixing the same complete all as specified and directed.
S&F in replacement electronic LED security light driver ISI marked as approved suitable for LED fittings of cap 60 to 120 watts any type and make and matching make to existing make of street light and flood light, after taking down the street light and refixing the same complete all as specified and directed.
Supply and fixing in replacement MCB single pole 240 volts, B series, any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
Supply and erecting " in replacement" in true vertical position steel tubular swaged poles of 9 metres long, type 410 SP-31 complete with cast iron base plate, goose neck bracket, finial taper plug , bolt, nuts & screws as specified and painting internal surface with anti-corrosive paint and external surface painting up to 1.5 m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strip 30 cm wide over a coat of red oxide primer and remaing portion with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed. Note:-Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.
Supply and erecting " in replacement" of broken pole with prestressed concrete pole 9m long, of size 102mmx172mm at top and 102mmx279mm at bottom, class 10, including zebra painting to PCC poles up to 1.5m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strips 30cm wide. complete all as specified and directed. Note:- (i) Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately. (ii) Rate quoted shall include for disposing off the broken pole ouside the MoD land.
M&L for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron wire of 4mm dia as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
M&L for earthing with GI earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Trimming up of Bushes/ Tree branches all around overhead lines from AOR of GE(S) Mamun removing cut branches from site complete all as specified and directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches upto 3 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department. (ii) only effected Span at site shall be measured where tree branches are touching nearly HT/LT lines complete all as specified and directed.
S&F as in repalcement danger notice plate factory made of 1.6mm thick mild steel sheet, vitreous enamelled white duly writing, 1100 volt electric line with letters/figures of appropriate size and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
M&L for painting of PCC pole 9 mtr height without removing accessories with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamell paint . marking the pole number with black synthetic enamel paint over yellow circle of dia 100mm. Painting the steel parts i.e clamps, channels etc by applying one coat of alumnium paint all as required at site, complete all as specified and directed.
S&F as in replacement of surge protection device after taking down street light, ISI approved company made as per existing make of street light, suitable for LED fittings of capacity upto 150watts complete all as specified and directed.
S&F in replacement of box type display in cuboid shape made out of acrylic sheet both side framed with stainless steel pipe dia 40mm of size 60x25cm and lenght up to 3mtr incl 20 Watt LED fitting fixed inside for reflection of test incl fixing arrangement on 60mm stainless steel pipe size of text 10 cm to 20 cm fixed on PCC of size 0.6mtrx0.45mtrx0.6mtr complete all as specified and directed. Note :- (i) Text written on the boards in both side will be decided by Engr-in-charge. (ii) Cost of stainless steel pipe should be include in qouted rates. (iii) Cost of PCC 1:2:4 will be deemed to be included in item rates. (iv) Cost of fabrication/jointing of pipe for framing the boards will be deemed to be included in item rates. (v) Bound ground of acrylic sheet colour and letter will be decided by Engr-in-charge.
Supply and fixed as in replacement of pole mounted street light factory fabricated junction box of size 260mm x 160mm x 250 mm of approved make and of appropriate size made out of 3.15 mm thick CRCA powder coated sheet as per IP 65, including 63A ,Three Phase four wire having four no. AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock (both side of plate) having Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed.
M&L for laminated stickers for marking of SM NO /feeder location for Transformer/LT panel etc.,as required at ground, consisting o min 10 letters of length not less than 4 cm height text size and colour on stickers will be decided by engr-in-charge complete all as specified and directed.
S&F as in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required with 32x6mm dia galvanised iron strip complete all as specified and directed.
S&F as in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required with 25x4mm dia galvanised iron strip complete all as specified and directed.
M&L for repairing, servicing and replacement of LT panels unserviceable part i.e lock key, rubber gasket, hinges and door frame including complete broken accessories such as partialy open door, brocken door, unserviceable aluminium bus bar, unserviceable/brocken locking arrangement, repairing of LT panel legs, welding work, necessary PCC work, excavetion and earth work including disconnection and reconnection of cables with suitable size of aluminium lugs in proper engineering practice, for any size of cables in any capacity LT panel also fixing of LT danger notice plate both side of the panel complete all as specified and directed.
M&L for painting of LT panel after removing old dust particles, oily portion by rubbing with sand paper and painting a coat of synthetic enamel paint with spray pump, and writing/digital printing, capacity description, date of installation, etc alongwith fixing LT danger notice plate both side complete all as specified and directed.
Supply, installation, commissioning and testing of totally enclosed outdoor type LT Panel in replacement weldless cubical Kiosk in modular bolted construction type dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size by manufacturer.All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement.all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and control gear compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 400 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,thimble , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size not less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , suitable for and including taking down existing LT panel complete and including the following :-
(i) MCCB 4 pole 415 volts 250 amp rating microprecesser based . Thermal magnetic release with rupturing capacity 36 KA - 01 No. as incomer.
(ii) MCCB 4 pole 415 volts with thermal based release rupturing cap 36 KA, 160 amps -1 Nos. for outgoing.
(iii) MCCB 4 pole 415 volts with thermal based release rupturing cap 36 KA, 100 amps - 2 Nos. for outgoing.
(iv) Load changeover switch 4 pole 415 volts cap 160/200 amps in open execution.
(v) LED Indicator set RYB -01 Set of 3 pcs only
(vi) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio.
(vii) Provision of star delta motor starter with fully automatic Star Delta starter type AC-3 phase 415 V , 50 Hz suitable for 60 HP elect motor.
(viii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as specified and directed.
S&F in insulation mat of size 2 mtr x 1 mtr x 15 mm complete all as specified and directed.
M & L for making serviceable to old UNSV Motor starter of any type after carrying out necessary repair and by replacement of defective minor spare parts such as connector, burnt control copper cable, insulator ,Terminal Block, copper thimbles, etc or if any other required minor spare parts at site for including testing to ensure efficient and smooth functioning of starter complete all as specified and directed. Note:- Defective major components/spares if required to be replaced shall be measured as supply only under respective item 63 to 77 here-in-after and labour element 5 deemed to be included in this item for replacement .
Supply only power contactor 3 pole 40/50 Amps as per existing sample complete including connection & testing complete all as specified and directed.
Supply only power contactor 3 pole 70/80 Amps as per existing sample complete including connection & testing complete all as specified and directed.
Supply only power contactor 3 pole 95/110 Amps as per existing sample complete including connection & testing complete all as specified and directed.
Supply only Add-on aux. contact Block suitable to existing contactor alongwith connecting and testing complete all as specified and directed.
Supply only Ammeter 3 phase of suitable rating to existing CT complete including connection & testing complete all as specified and directed.
Supply only volt meter 3 phase 500 volts 50 Hz squire type suitable size to existing one complete including connection & testing as per existing sample complete all as specified and directed
Supply only HRC fuse 63/100 Amps of suitable size to existing one complete including connection & testing complete all as specified and directed.
Supply only LT CTs of suitable rating & size as per existing one complete including connection & testing complete all as specified and directed.
Supply only timer as per existing sample for fully automatic motor starter complete all as directed.
Supply only single phase preventer as per existing sample for fully automatic motor starter complete all as directed.
Supply only over load relay of range 45 to 120 Amps or as per existing sample complete all as directed.
M & L for replacement of old u/s ON/OFF, Start/ Stop push button suitable size, colour and rating to existing one complete including connection & testing complete all as directed.
M & L for replacement of old u/s indication lamps with LED type indication lamps with showing red, yellow and green colours suitable for 240 Volts AC supply as per existing size complete including connection & testing complete all as specified and directed.
M & L for making serviceable old UNSV Single phase preventer wall mounting 415 volts, 3 phase of any type carrying out repair and replacement of unserviceable minor spare parts such as connector, burn controle cable, insulator ,Terminal Block, copper lugs, etc for making the MPC serviceable and testing at site complete all as specified and as directed.
Repair to oil immersed star delta starter by replacing fixed, moving contact, relay, No volt coil etc required for making starter serviceable of any capacity complete all as specified and directed.
Supply and top up/replacement of electric motor starter oil complete all as specified and directed.
S & F in replacement 3 pole MCCB 63 Amp adjustable type Thermal Release Range with breaking capacity- 25 KA (as per existing sample frame size)complete all as specified and directed.
S & F in replacement 3 pole MCCB 100 Amp adjustable type Thermal Release Range with breaking capacity- 25 KA (as per existing sample capacity & frame size)
S & F in replacement 4 pole MCCB 160 Amp adjustable type Thermal Release Range with breaking capacity- 25/36 KA (as per existing sample capacity & frame size)
S & F in replacement 4 pole MCCB 200-250 Amp adjustable type Thermal Release Range with breaking capacity- 36 KA (as per existing sample capacity & frame size)
Supplying, fixing in replacement for on load changeover switch 4 pole, 415 volts, 100 Amps in Open execution type
Supplying, fixing in replacement for on load changeover switch 4 pole, 415 volts, 160/200 Amps in Open execution type
S & F in replacement of motor protection circuit breaker (MPCB), 415 Volts, 3-ph, 50 Hz, 63 Amp rating having short circuit & over load protection rotary type including taking down old of any capacity complete all as directed.
Supply installation, commissioning and testing of star delta starter suitable for submersible pump 40 HP, fully automatic in sheet metal enclosure type AC-3 phase, 415V, 50 Hz including taking out old unserviceable starter of any type complete all as directed
All as per above item No 88 but suitable for 30 HP electric motor complete all as specified and directed .
All as per above item No 88 but suitable for 25 HP electric motor complete all as specified and directed .
All as per above item No 88 but suitable for 60 HP electric motor complete all as specified and directed .
KULBHUSHAN AGGARWAL
M/S HIMANSHU BUILDERS
Bidder Name
KULBHUSHAN AGGARWAL
M/S HIMANSHU BUILDERS
M/S SHRI RAM BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .