Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC SHAD NO 11 DSIIDC WAZIRPUR INDUSTRIAL AREA DELHI 110052 | DELHI | DELHI | DELHI | 110052 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹38.7 L+₹9,065 (0.23%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹45.6 L+₹7.0 L (18.2%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹47.6 L+₹9.0 L (23.3%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹48.0 L+₹9.4 L (24.3%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
28 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) KOLKATA
D9 COMMISSARIAT ROAD HASTINGS KOLKATA 700022
REPAIR/MAINT OF EXTERNAL LIGHTING WITH CONNECTED WORKS AT OUTSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2021_MES_477432_1
8789/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (FW) Kolkata
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE(FW) KOLKATA
₹84,000
Yes
18 Dec 2021
24 Sept 2021
29 Oct 2021
24 Sept 2021
28 Oct 2021
21 Oct 2021
60 days
Amount
Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables, poles, stay and getting out of excavated material complete all as specified and directed by Engineer-in-Charge
Excavation of trench in road/hardstanding etc, not exc 1.50 m wide and not exc 1.50 m deep and getting out complete all as specified and directed.
M&L for sand cushioning/sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. (NOTE: Punned thickness shall be measured for payment)
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed by Engineer-in-Charge
M&L fly-ash bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Laying only old bricks (retrieved during taking out of cable) in trenches above sand cushioning for cable protection complete all as specified and as directed.
M & L for hardcore of gauge exc 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken stones complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 using 40 mm graded crushed stone aggregate complete all as specified and directed by the Engineer-in-Charge.
Horizontal Boring under road / foot path/hardstanding, for passing pipes up to 100 mm bore (dia), not exc. 20.00 metre in a single length, complete all as specified and directed. (NOTE: Pipes shall be measured and paid seperately)
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 35 Sqmm, 3.5 core
50 Sqmm, 3.5 core
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No 1 above) incl necessary aluminium thimbles, jointing and testing complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 35 Sqmm, 3.5 core
50 Sqmm, 3.5 core
Supply, Laying, jointing and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary thimbles complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 Sqmm, 4 core
16 Sqmm, 4 core
25 Sqmm, 4 core
35 Sqmm, 3.5 core
50 Sqmm, 3.5 core
S&F in repair 100 mm bore galvanized iron pipe (light grade) with all fittings, laid in trenches or under roads/floors/culverts etc complete all as specified and as directed by the Engineer-in-charge.
S&F in repair 80 mm bore galvanized iron pipe (light grade) with all fittings, laid in trenches or under roads/floors/culverts and/or fixing to electric poles with suitable size mild steel flar iron clamps, bolts, nuts & washers etc complete all as specified and as directed by the Engineer-in-charge.
S&F in repair 50 mm bore galvanized iron pipe (light grade) with all fittings, laid in trenches or under roads/floors/culverts and/or fixing to electric poles with suitable size mild steel flar iron clamps, bolts, nuts & washers etc complete all as specified and as directed by the Engineer-in-charge.
S&F in repair cable junction box 205 x 255 x 112 mm in size, made out of thermoplastic sheet having IP 66 protection for outdoor installation including terminals for fixing on street light pole using GI clamps of size 30 x 5 mm (02 Nos each pole) with suitable size of nuts, bolts, washers etc incl dismantling of old unsv box complete all as specified and directed. (MAKE : HENSEL, Cat No: KF 2525B or equivalent model in SPELSBERG / SCHNEIDER / RITTAL)
S&F in repair cable junction box 255 x 355 x 122 mm in size, made out of thermoplastic sheet having IP 66 protection for outdoor installation including terminals for fixing on street light pole using GI clamps of size 30 x 5 mm (02 Nos each pole) with suitable size of nuts, bolts, washers etc incl dismantling of old unsv box complete all as specified and directed. (MAKE : HENSEL, Cat No: KF 5000B or equivalent model in SPELSBERG / SCHNEIDER / RITTAL)
S&F in repair connector cable suitable for fixing of armoured cable of cross sectional area 25 sqmm to 50 sqmm for preventing of short circuiting of cable in junction boxes complete all as specified and directed. (MAKE: HENSEL/SPELSBERG/ SCHNEIDER/ RITTAL)
S&F in repair rigid steel conduit 25 mm dia exclusive of boxed (junction/terminal) but inclusive of all tees, bends elbows, reducers, bell mouth etc and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete all as specified and directed.
Taking out existing unserviceable/ defective light fitting / high bay light fitting of any wattage from poles/walls/ high mast (including taking down of high mast fitting), dismantling the complete fittings of checking out the defects, trace out damage/ unserviceable parts like driver, wire, led lamp etc and clean thoroughly the complete set and re-fixing in its original position after replacing defective parts including testing complete all as specified and as directed by Engr-in-Charge. Note :- (a) Any minor item like nuts, bolts, clamps, washers and wires for connection is required to make the fitting serviceable are deemed to be included in the quoted rate. (b) Defective parts replaced against relevant items shall be paid under supply only item.
M&L for replacement of electronic driver with input voltage 220 to 240 volts and output voltage suitable for different LED of luminaires, complete all as specified and directed for the following types and capacities:-. (NOTE: Make of driver shall be as OEM or any other make as specifically approved by GE)
25 watt street light luminaire
40 watt street light luminaire
45 watt street light luminaire
60 watt street light luminaire
70 - 72 watt street light luminaire
80 watt street light luminaire
90 watt street light luminaire
100 watt street light luminaire
120 watt street light luminaire
10 watt flood light luminaire
30 watt flood light luminaire
50 watt flood light luminaire
60 watt flood light luminaire
80 watt flood light luminaire
100 watt flood light luminaire
120 watt flood light luminaire
150-160 watt flood light luminaire
9-12 watt bollard
25-40 watt post top lantern
M&L for replacement of PCB card suitable for different LED of luminaires, complete all as specified and directed for the following types and capacities:-. (NOTE: Make of PCB Card shall be as OEM or any other make as specifically approved by GE)
25 watt street light luminaire
40 watt street light luminaire
45 watt street light luminaire
60 watt street light luminaire
70 - 72 watt street light luminaire
80 watt street light luminaire
90 watt street light luminaire
100 watt street light luminaire
120 watt street light luminaire
10 watt flood light luminaire
30 watt flood light luminaire
50 watt flood light luminaire
60 watt flood light luminaire
80 watt flood light luminaire
100 watt flood light luminaire
120 watt flood light luminaire
150-160 watt flood light luminaire
9-12 watt bollard
25-40 watt post top lantern
S&F in repairs surge protection device of capacity 10 KV single phase 50 Hz complete all as specified and as directed. (NOTE: Make of surge protection device shall be as OEM or any other make as specifically approved by GE)
S&F in repairs PVC insulated multistranded copper conductor wire, 1.5 sqmm 3 core, round flexible for connection of light fittings complete all as specified and as directed.
S&F in repairs PVC insulated multistranded flat service aluminium conductor cable, 1100 volts grade, heavy duty, served with inner sheathing of PVC tape and overall PVC sheathed of size 16 sqmm 2 core complete all as specified and directed.
S&F in repairs LED Highbay luminaire, circular shape, of 150 watt capacity, in high pressure die cast aluminium housing with lens and toughened glass cover with integrated constant current electronic driver, complete all as specified and directed & complying with the following specifications:-. (a) minimum efficacy 130 lumen/watt (b) CRI not less than 80, (c) THD < 10% (d) Power factor not less than 0.95 (e) having in built short circuit and surge protection upto 5 kV (f) colour temperature not less than 5700 degree K (g) life not less than 50000 hours of operation (h) Weather protection grade: IP66
S&F in repairs LED Street Light fitting, of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver, top opening driver cover, IP66 ingress protection, impact resistance of IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power Factor not less than 0.90 (e) having in built short circuit and surge protection upto 4 kV (f) having 10 KV external surge protection (for 45 watt & above) (g) colour temperature not less than 5700 degree K (h) life not less than 50000 hours of operation
35/36 Watt Street Light Luminaire
60 Watt Street Light Luminaire
90 Watt Street Light Luminaire
100 Watt Street Light Luminaire
S&F in repairs LED Flood Light fitting, of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver and toughened glass cover, IP66 grade ingress protection, impact resistance IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power factor not less than 0.90 (e) having in built short circuit and surge protection upto 4 kV (f) having 10 KV external surge protection (g) colour temperature not less than 5700 degree K (h) life not less than 50000 hours of operation
10 Watt Flood Light Luminaire, with IP 65 grade protection, 100 lumen/watt
70 Watt Flood Light Luminaire
100 Watt Flood Light Luminaire
120 Watt Flood Light Luminaire
180 Watt Flood Light Luminaire
(NOTES FOR ITEM NO. 27 TO 29:- (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Wire for electric connection shall be measured and paid separately)
S&F in repair LED flexi strip of 50 m length, IP 65, 5watt/metre, any colour including suitable driver and connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. (MAKE : MAGIK, Model: Stream LED Strip Light or equivalent model in other makes specified in tender)
S&F in repairs LED pathway luminare, 9/10 watt, in powder coated ERW MS tubular/square sections, with cylindrical diffuser on top complete, IP 65 grade protection, operating voltage 120-280V, with integrated constant current electronic driver incl all fittings and fixtures complete with PCC work incl taking down existing luminaire complete all as specified and directed. (Make : BAJAJ, Cat No: BGBOL 605 9W LED WW / CROMPTON, Cat No: LBLA1-10-CDL / HALONIX, Cat No: HLOB-02-10-CW / SURYA, Cat No: SLE BL 9W-GLZ600/EVEREADY, Model: IRIS or equivalent model in other makes specified in particular specifications) NOTE: Wire for conection of luminaire shall be measured and paid seperately.
-ditto but inverted pyramid tripod type luminaire with soft 360 degree light distribution , with IP 65 grade protection (MAKE: CROMPTON, Model: LIARA / SURYA, Model: BLINK or equivalent model in other makes specified in tender)
S&F in repair LED post top luminiare, 40-45 watt, with die cast amuninium spigot, spun aluminium powder coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver incl taking down existing luminaire complete all as specified an directed. (Make : BAJAJ, Cat No: BGCT W4 LED WW / HALONIX, Cat No: HLPT-04-40-CW / SURYA, Cat No: SLE PT 40W-ETPP / MAGIK, Cat No: APBY040C0875 / EVEREADY, Model: HOLLY / C&S, Cat No: CETUS/40W or equivalent model in other makes specified in particular specifications) NOTE: Wire for conection of luminaire shall be measured and paid seperately.
-ditto but of 20-25 watt capacity (MAKE: BAJAJ, Cat No: BGCTN 25W LED WW / MAGIK, Cat No: APBY020C1259 / HALONIX, Cat No: HLPT-04-25CW / HAVELLS, Model: RUBY / C&S, Cat No: CETUS/20W or equivalent model in other makes specified in tender)
S&F in repairs LED aviation light luminarie integral type comprising aluminium housing with polycarbonate enclosure incl taking down existing luminaire complete all as specified an directed. Make : Bajaj Cat No BGAV 302 LED / HALONIX, Cat No: HAVL 01 S 230 or equivalent model in other makes specified in particular specifications) NOTE: Wire for conection of luminaire shall be measured and paid seperately.
Demolition of broken/damaged PCC copinf of steel tubular/PCC pole and removal of debris from site complete all as specified and directed.
S&F in repair astronomical time switch 2 module 240 Volt AC, DIN mounting type suitable for street light operation complete all as specified and directed. (MAKE: L&T, Cat No: AUTS02AST00 or equivalent model in LEGRAND / HAGER / SCHNEIDER / INDO ASIAN)
S&F in repair contractor 40 Amps, 3 pole, type MO40, DIN mounting type suitable for street light operation complete all as specified and directed. (MAKE: L&T, Cat No: CS94659 or equivalent model in LEGRAND / HAGER / SCHNEIDER / INDO ASIAN)
S&F in repair MCB TPN 63 Amps, 415 Volts, 10 kA, 'C' curve complete all as specified and directed. (MAKE: L&T, Cat No: BB40630C or equivalent model in LEGRAND / HAGER / SCHNEIDER / INDO ASIAN)
S&F in repairs Street light junction box made out of 2 mm thick mild steel sheet including applying two coats of synthetic enamel paint over a coat of zinc chrome primer duly spray painted of size not less than 25 cm x 20 cm x 10 cm with locking arrangements inclusive of 20 x 3 mm thick aluminium bus bar 100 amps - 04 Nos of suitable length incl MCB SP 5 amp - 01 No, fixed on and including insulators for mounting bus bar (with provision of cable entry and exit conduit), fixed with necessary flat iron clamp of size 25mm x3 mm 2 Nos (length as reqd to fix in pole), bent to required shape including painting, at bottom portion of the pole (above coping), fixed with GI bolts, nuts and washers (of suitable size) complete all as specified and as directed by the Engineer-in-charge .
S&F in repair Bracket/Arm suitable for street light fittings, made out of 32 mm bore (light grade) GI pipe length not exceeding 1.5 metre long, fixed with 02 sets of flat iron clamp of size 25mm x 5 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed by the Engr-in-Charge.
Taking down and re-fixing of serviceable street light/security light fitting, any wattage or size, in any position with new bracket incl necessary electrical connection with existing cable complete all as specified and directed. (NOTE: Bracket shall be measured and paid separately)
S&F cable jointing kit for heat shrinkable straight through joint complete with jointing material (epoxy based) and accessories, suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed for the following size of cables :-
upto 16 sqmm, 3.5/4 core
25 sqmm to 50 sqmm, 3.5/4 core
S&F in repair GI tubing 50mm bore (light grade), 70 to 100 cm long with long bends on one end, for incoming and outgoing cables, duly grouted in cement concrete complete all as specified and as directed. (NOTE: Cement concrete will be measured seperately)
Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of old painted surfaces of steel tubular poles above PCC coping including cross arms, brackets, pole box and applying one coat of aluminium paint including removal of vegetation on poles, trimming of tree branches in the vicinity, writing of pole number with stencil in white paint over black base and two black and two yellow stripes upto 1.20 m height with synthetic enamel paint complete all as specified and directed.
M&L for removing of black/yellow stripes on PCC poles and painting of black/yellow stripes, each of 30cm height upto 1.50 m from bottom and writing pole number with stencil in white paint over black base with synthetic enamel paint complete all as specified and directed.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
Commercial Electric Co.
ARATI TRADING CO
BHASKAR SUPPLY AGENCY
RADHA ENTERPRISE
PINKY CO.
ARJUN DAS VALECHA
DEEPAK KHATTAR
S. K. CONSTRUCTION SYNDICATE AND ENGINEERING CO.
UNIVERSAL TRADING CENTRE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .