| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹44.4 L+₹68,838.96 (1.58%)Rejected-AOC | L2 | Rejected-AOC Higher rate quoted than L1 | |
| 3 | L3₹44.8 L+₹1.1 L (2.59%)Rejected-AOC J L BHAWAN MANKAR ROAD BUD BUD BAZAR PO BUD BUD DISTT BURDWAN WB | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L3 | Rejected-AOC Higher rate quoted than L1 | |
| 4 | L4₹45.2 L+₹1.6 L (3.56%)Rejected-AOC PO BUD BUD DIST BURDWAN WEST BENGAL PIN 713 403 | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L4 | Rejected-AOC Higher rate quoted than L1 | |
| 5 | L5₹47.6 L+₹3.9 L (8.93%)Rejected-AOC | L5 | Rejected-AOC Higher rate quoted than L1 |
Tender Value
₹48.8 L
EMD Value
₹97,700
Closing Date
9 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_552189_2
8400-859/E8
Open Tender
Civil Works
Works
210 days
PANAGARH
Class D and Category a (i) (Building)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹97,700
Yes
6 Feb 2023
19 Oct 2022
11 Nov 2022
19 Oct 2022
9 Nov 2022
26 Oct 2022
Amount
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed
M&L for removing excavated material exc. 250m but n.exc 500m and depositing where directed complete all as specified and directed
M&L for hardcore of gauge n.exc. 63mm, (broken stone/ boulders) deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed
M&L for 40 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in floors , subfloors complete all as specified and directed
M&L for brickwork with flyash bricks, straight or curved on plan.exc 6m mean radius, built in cement mortar (1:6) complete complete all as specified and directed
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces etc finished even and smooth without using extra cement complete complete all as specified and directed
M&L for preparation on newly plastered surfaces on wall and applying two coats of cement based paint over priming coat of alkali resistant priming paint, complete all as specified and directed.
M&L for cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete complete all as specified and directed
M&L for forming 12mm thick expansion joints fillled with pre-formed bituminous filler with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound Grade 'A' complete all as specified and directed.
Excavating in trenchs, n.exc 1.5m wide and n.exc 1.5m in depth; for foundation, etc. n.exc 10sq m on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for (Design Mix) M-25 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintel over 1.5m span complete all as specified and directed.
M&L for (Design Mix) M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns, hocking, ends and binding with and incl MS wire (appealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for TMT bar but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; n.exc 200mm thick (horizontal or sloping) complete all as specified and directed.
M&L for providing precast cement concrete louvers and jallies, 25mm thick (measured solid),type B0 1:2:4 (using 12.5mm graded stone aggregate), set in cement mortar (1:6) including all moulding but excluding frame, complete all as specified and directed.
M&L for machine pressed precast pre-polished concrete interlocking paver block with using of gray cement and pigment of any shape, size and colour confirming to IS 15658-2006 of 60 mm thickness, M-35Grade complete complete all as specified and directed
M&L for providing, cement concrete 1:2:4 (using 12.5 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed
M&L for moorum/red bajri filling in floors or pavings, laid in layers n.exc. 15 cm thick, spread, levelled and rammed including watering as required complete all as specified and directed
M&L for 75 mm thick cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection complete all as specified and directed
M&L for (Design Mix) M-25, (using 20mm graded stone aggregate) as in, slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for (Design Mix) M-25 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantiliver shelves etc.for fair finished surface complete all as specified and directed
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc.for fair finished surface complete all as specified and directed
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete raillings , opening in concrete walls, floors and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls, hozontal or sloping and similar work exc 5cm but n.exc 10cm etc.for fair finished surface complete all as specified and directed
M&L for Glazd ceramic coloured tiles 350x 250 x7mm/450x350x7mm thick in dado/vertical, set and jointed in neat cement slurry and pointed in colour cement to match including rendering 10mm thick in cement mortar (1:4) complete all as specified and directed .
M&L for non skid ceramic coloured tiles of 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11sqm but nexc 0.18 sqm, in floors etc.set and jointed in neat cement slurry and pointed in white/coloured cement to match with the existing and including cement screeding 15mm thick in cement mortar (1:6) complete all as specified and directed (Make- Somany/Orient/Johnson).
M&L for sand for laying of interlocking floor finishing complete complete all as specified and directed
M&L for 75mm thick PCC 1:4:8 type C2 (using 20mm graded stone aggregate) as in sub base complete complete all as specified and directed.
S&F PVC( SWR) pipes 110 mm bore single socketed, in any length with rubber ring joint, laid in trenches or in floors complete all as specified and directed
S&F PVC( SWR) pipes 75 mm bore single socketed, in any length with rubber ring joint, laid in trenches or in floors complete all as specified and directed
S&F PVC (SWR) bends of any radius 110 mm size complete complete all as specified and directed
S&F PVC (SWR) bends of any radius 75 mm size complete complete all as specified and directed
S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and directed
M&L for brickwork with fly ash bricks, straight or curved on plan to any radius in half bricks thick walls, built in cement mortar (1:4) complete complete all as specified and directed
M&L for rendering 15 mm thick in CM (1:4) using water proofing compound on fair faces of brick work or concrete surfaces etc finished even and smooth without using extra cement (water proofing compound to be measured and paid seperately) complete all as specified and directed
M&L for rendering 15 mm thick in CM (1:6) on other than fair faces of brick work or concrete surfaces etc finished even and smooth without using extra cement complete all as specified and directed
M&L for rendering 5 mm thick in CM (1:3) on brick or concrete surfaces (in ceiling) etc finished even and smooth without using extra cement complete all as specified and directed
Supply only liquid water proofing compound complete all as specifed and directed by the Engr-in-Charge. (Make : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for applying three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete complete all as specified and directed
M&L for applying white wash three coats on newly plastered surfaces of ceiling including preparation of new surfaces for matching with repaired surfaces complete all as specified and directed.
Supplying and laying of concealed type 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete complete all as specified and directed. Note : Chasing cutting and making good surface deemed to be incuded in above quoted rate.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete complete all as specified and directed
S&F extruded aluminum alloy handles fabricated type and anodised of size 150mm, complete all as specified and directed
S&F sliding door bolts, aluminum anodised with hasp and stapple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded sections, length of bolt sliding 300mm long complete complete all as specified and directed
S&F for butt hinges medium weight stainless steel and fixed 100mm size complete all as specified and directed
S&F factory made solid decorative WPC (wooden plastic composite) flush door shutter , 28 to 30 mm thick as per manufacturer specification complete all as specified and directed. (Make :Rajshree pastiwood or equaivalent make as approved by GE).
S&F solid WPC (wooden plastic composite) door frame 85mmx45mm suitable for WPC flush door complete complete all as specified and directed
S&F Steel windows with side hung shutters (minimum wt. of steel section should be 1.42 kg/M) including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each panes as specified.
S&F stainless steel wire cloths 0.36 mm nominal dia of wire and average width of aperature is 1.40 mm and fixed with tinned tacks or galvanised wire staples complete complete all as specified and directed
S&F framed work such as grills gratings end of bars shoulders and or riveted, or forged into spikes; framed Guard bars and similar works conforming to Fe-290. Gde-E-165 complete all as specified and directed.
M & L for rendering 10mm thick on fair faces on roof surfaces of concrete surfaces in cement mortar (1:4) without using extra cement including water proofing compound, complete all as directed .
Material & Labour for preparation ne surfaces of roof and applying two coats of Polyurethene (PU) acrylic based water proofing liquid compound over & including one coat of self priming primer @ one litre per ten sqm with reinforcing fabric sheet as per manufactures instruction to stop leakage/seepage from roof/wall complete all as specified and directed by the Engineer-in-Charge. Notes:- (i) As per description of theis item minimum two coats of Polyurethene (PU) acrylic based water proofing liquid compound over one coat of primer shall be carried out by as per manufacturer instruction. Please note no price adjustment shall be made, if as per manufacturer instructions more coats of Polyurethene(PU) acrylic based water proofing liquid compound & primer are required for roof treatment. (ii) Quoted rate shall be deemed to be included for work in building/Structure of any height.
Supplying and laying of Supreme Eco drain Hi-tech pipe dranage sewer system pipe bearing 160 mm dia minimum 4mm thick including jointing with couplar, bend tee as per site requerement complete laid in trenches or floors complete all as specified and directed.
M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggregates) incl packing under and haunching against the sides for 160mm internal dia SGSW pipes after they are laid and tested complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide on steel surfaces of any description complete all as specified and directed
S&F CP bottle trap 32mm size with 250mm & 190mm long wall connection pipe and wall flange complete all as specified and directed. (Make: Jaquar Cat Part No ALD 769L250x190 or equivalent Cat Part No of Kohlar/Kerovit)
S&F in vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern) incl all necessary accessories like seat cover, rag bolts/ gel gasket, with flushing cistern complete all as specified and directed (Make: Jaquar Cat Part No CNS-WHT-353SPPZ or equivalent Cat Part No of Kohlar/Kerovit)
S&F 125mm dia grating doom with waste hole of PTMT (Minimum weight 40 gms) fixed in cement mortar (1:3) complete all as specified and directed
S&F CP auto closing concealed urinal flush valve with wall flange and connection to pipe complete all as specified and directed. (Make: Jaquar Cat Part No PRS-073 or equivalent Cat Part No of Kohlar/Kerovit)
S&F vitereous china bowl urinal half stall type, complete including providing and fixing plug, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe complete complete all as specified and directed. (Make: Jaquar Cat part No URS-WHT-13253N or equivalent Cat Part No of Kohlar/Kerovit)
Supply flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed
S&F in 15mm CP angular/ stop cock with flange complete all as specified and directed (Make: Jaquar Cat Part No CON-059KN or equivalent Cat Part No of Kohlar/Kerovit)
S&F pillar taps, cast copper alloy, fancy type, chromium plated, screwed down high presure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed (Make: Jaquar Cat Part No FUS-29005NB or equivalent Cat Part No of Kohlar/Kerovit)
S&F vitreous china wash basin with cabinet having length 61.0 cm, width 47.5 cm and height 46.5 cm alongwith mirror with frame , waste coupling complete all as specified and directed (Make: Kerovit Cat Part No KAJ0387 for wash basin and Cat Part No KAJ0393 for mirror with frame or equivalent Cat Part No of Kohlar/jaquar)
S&F 15 dia fancy type chromium plated two way bib taps cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe complete all as specified and directed (Make: Jaquar Cat Part No ALI-85041 or equivalent Cat Part No of Kohlar/Kerovit)
S&F CP soap dispenser complete all as specified and directed (Make: Jaquar Cat Part No ACN-1137N or equivalent Cat Part No of Kohlar/Kerovit)
S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed (Make: Jaquar Cat Part No ACN-1171N or equivalent Cat Part No of Kohlar/Kerovit)
S&F brass cromium plated Tubular towel rail, 20mm dia, D type, 60cm complete all as specified and directed (Make: Jaquar Cat Part No ACN-1111SM or equivalent Cat Part No of Kohlar/Kerovit)
S&F towel rack made of staineless steel of size 600X250mm fixed to wall with stainless steel screws complete all as specified (Make: Jaquar Cat Part No ACN-1181S or equivalent Cat Part No of Kohlar/Kerovit)
S&F curved shaped urinal partition with 8mm thick frosted glass 900mm height and 450mm width complete all as specified and directed (Make: Jaquar Cat Part No JSE-CHR-810UC450X or equivalent Cat Part No of Kohlar/Kerovit)
S&F towel ring of CP with including Chromium plated brass screws complete all as specified and directed (Make: Jaquar Cat Part No CAN-1121N or equivalent Cat Part No of Kohlar/Kerovit)
S&F toilet paper holder with flat recessed type stainless steel Complete all as specified and directed (Make: Jaquar Cat Part No ACN-1153S or equivalent Cat Part No of Kohlar/Kerovit)
S&F Brass CP mixer of 15mm dia for mixing hot & cold water screwed down for iron pipe and fixed for WHB, Bath room complete all as specified and directed (Make: Jaquar Cat Part No CON-309KNM or equivalent Cat Part No of Kohlar/Kerovit)
S&F health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.20 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. (Make: Jaquar Cat Part No ALD-587 or equivalent Cat Part No of Kohlar/Kerovit)
S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed (Make: Jaquar Cat Part No ALD-083FT & ALD-089FT or equivalent Cat Part No of Kohlar/Kerovit)
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed
S&F for waste pipe for WHB/urinal of any size complete all as directed by Engr-in-charge.
S&F 110 mm bore PVC (SWR), junction single, (single T), equal or unequal with access door complete all as specified and directed.
S&F 75 mm bore PVC (SWR), junction single, (single T), equal or unequal with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl 100 mm bore complete all as specified and directed
S&F for 25mm bore GI tubing medium grade in trenches/floor/ pillar connetion in old or new postion including fittings complete all as specified and directed. (Make: Bansal / Jindal/TATA)
All as per item No 86.00 mentioned here-in-above but 40 mm bore complete all as specified and directed
S&F 25 mm bore gun metal globe or gate valves, yoke type, full opening with iron wheel head, screwed both ends heavy duty, ISI marked complete for iron pipes complete all as specified and directed.
S&F rotational/moulded polyehtylene multilayer water tank (cylindrical vertical with closed top) hoisted & fixed in position all as specified directed capacity of 500 Ltr complete all as specified and directed. (Make: Sintex/Vectus/Prayag)
S&F ball brass valves, high pressure, with polyethylene float and flynut complete, screwed for iron pipe or brass ferrule for 25mm bore complete all as specified and directed.
E/M PORTION S&F XLPE insulated armoured cable, 25 sqmm 4 core,1100 volts grade heavy duty cable,ISI marked passing through pipe/fixing on wall/trenches, PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as sepcified.
Supply, commissioning and testing Outdoor type double door LT Distribution Panel (including taking down old panel), weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing cable alley on both sides IP-54 protection, IEC61439 installed on concrete base foundation made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (min 50 x 10 mm copper bus bar) (b) Indication lamp for RYB - 01 Set (c) MCCB-200 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Incoming) (Make - GE/Schneider/Seimens) (d) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-03 No(Outgoing) (Make - GE/Schneider/Seimens) (e) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (Make - GE/Schneider/Seimens) (e) MCB-63 Amp, 4 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-06 No(Outgoing) (Make - GE/Schneider/Seimens) (f) S&F digital ampere meter 3 1/2 display incl CT having CTR 200/5-01 Nos (g) S & F digital voltmeter 0-500 V = 01 Nos (Note: 01 No spare compartment to be provided)
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. (Note : Punned thickness shall be measured).
S&F GI pipe light grade 40 mm dia of size for road cross of cable,ISI marked all as specified and directed.
M&L for sub class 'B' bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using galvanised iron strip 32×6mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. (Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge , entered in the eath testing register, prepared and to be maintained by the contractor & submited to Concerned JE E/M. (iii) T&P and testing instrument(Meger) to be provided by the contractor at own cost).
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC casing caping and fittings of medium grade, including pressed steel terminal switch boxes/sutable for modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes for suitable module & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
M&L for point wiring for one socket outlet on independent board controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated Unsheathed FRLSH cables in and including suitable size PVC casing and caping (ISI marked), including pressed steel terminal switch boxes/surface box suitable for ordinary/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor, PVC insulated unsheathed FRLSH cable as earth wire and connecting to earth dolly and brass screws, washers etc. complete complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 100.00 mentioned here-in-above but 5 Amp socket on same board with other switches.
M&L for point wiring for socket outlet 3 pin, 5 amps on Independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC casing and caping and fittings of medium grade, including pressed steel terminal switch boxes/surface box suitable for ordinary/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
M&L for point wiring for socket outlet 3 pin, 5 amps on Independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F switch socket combination 2 in 1 , 6 pin , (16 Amps) flush type controlled by one switch complete complete all as specified and directed
S&F switch modular type 6 Amp one way, one module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F switch modular type 16/20 Amp one way, one module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F socket outlet modular type 6 Amp 2/3 pin , two module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F socket outlet modular type 16 Amp 2/3 pin , two module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F 20 W LED light fitting wall mounted batten 4'ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 20 watt, 6000K including necessary connection complete all as specified and directed.
S&F security light fittings 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed
S&F socket outlet modular type 25 Amp 2/3 pin , with MCB, single phase, complete all as specified and directed by Engineer-in-charge.
S&F modular power unit, 25 Amps, ISI marked, 240 Volts complete complete all as specified and directed
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete complete all as specified and directed
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core 4 Sqmm and one 4.0 Sqmm PVC insulated FRLSH cable with stranded copper conductor and 4.0 Sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC unsheathed earth wire and connected to earth dolly drawing into and including PVC Casing caping complete complete all as specified and directed. (Note: Three runs cable & PVC casing/caping shall be measured as single unit)
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core 6.0 Sqmm and one 6.0 Sqmm PVC insulated FRLSH cable with stranded copper conductor and 6.0 Sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC unsheathed earth wire and connected to earth dolly drawing into and including PVC Casing caping complete complete all as specified and directed. (Note: Three runs cable & PVC casing/caping shall be measured as single unit)
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core 10.0 Sqmm and one 10.0 Sqmm PVC insulated FRLSH cable with stranded copper conductor and 10.0 Sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC unsheathed earth wire and connected to earth dolly drawing into and including PVC Casing caping complete complete all as specified and directed. (Note: Three runs cable & PVC casing/caping shall be measured as single unit)
Shifting of existing electric metres from main panel to near building with PVC polycarbonate case for protection of electric meter of sutable size,fix and sealed the case including all necessary fittings all as specified and directed.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), tripple pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCCBs to be used), Vertical Triple pole and neutral 415 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SP 40 to 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB TPN 40-63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCCB 4 pole, 3 phase, 415 volt of capacity 125 Amp, 25 KA complete with proper copper thimbles, copper reducer etc all as directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth wire electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. (Note : (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge , entered in the eath testing register, prepared and to be maintained by the contractor & submited to Concerned JE E/M. (iii) T&P and testing instrument(Meger) to be provided by the contractor at own cost).
S&F of decorative front plate white or coloured for 8 modular complete all as specified and directed.
All as per item No 125.00 mentioned here-in-above but 3 modular modular complete all as specified and directed.
S&F blanking plate white or coloured for 1 modular complete all as specified and directed.
S&F 9 W LED mirror light fitting wall mounted batten 2ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 9 watt , 6000K including necessary connection complete all as specified and directed.
S&F exhaust ventilation fan with louvers of sweep 300mm,240 volts, BEE 5 star rated, steel body,complete all as directed by Engr-in-Charge.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed
S&F MCB SPN 63 Amps, 'C' curve, 240 Volts, ISI marked and to be housed in DBs complete including necessry connection all as specified and directed. (Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F XLPE armoured cable 10 sqmm 2 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as specified and directed.
MS ROYAL CONSTRUCTION INDEX NO 158 2010 BKP
FRIENDS CONSTRUCTION
ROY ENTERPRISE
M/S JK TRADING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .