Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical ACCEPT |
| 2 | Accepted-Technical | Accepted-Technical ACCEPT |
| 3 | Accepted-Technical KANPUR NAGAR | UTTAR PRADESH | 209402 | Accepted-Technical ACCEPT |
Tender Value
₹4.9 L
EMD Value
₹5,000
Closing Date
11 Mar 2026, 12:00 pmClosed
SE, EUDC, MATHURA
SE, EUDC OFFICE, NEAR TANK CHAURAHA, MATHURA
Carrying out various electric works for shifting of TF, Pole, Lines and Panel in the area of Executive Engineer (Technical 2, 11 KV and LT) under the jurisdiction of the Superintending Engineer, Electricity Urban Distribution Circle, Mathura
2026_DVVNL_1118988_2
31/EUDC(M)/2025-26
Open Tender
Electrical Works
Item Wise
90 days
EE (TECHNICAL 2) 11 AND LT
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
dvvnl.org
₹5,000
14 Mar 2026
2 Mar 2026
11 Mar 2026
2 Mar 2026
11 Mar 2026
2 Mar 2026
Cartage of following material from Store centre, Mathura to work site.
ST Pole (11 mtr. Long) SP-55 (Bottom Portion Galvanized)
11 KV XLPE Cable 3x120 Sqmm.
LT Aerial Bunch conductor 3x120sqmm.
LT XLPE Cable Al. 3.5x400 Sqmm.
LT XLPE Cable 3.5x240Sqmm.
Distribution Box
11 KV Polymer Pin insulator
11 KV Pin wth Nut
11 KV Polymer Disc. Insulator
11 KV Disc. Fitting
11 KV TPMO
11 KV Fuse Set
MS T-off Channel (125x65x1300mm)
Cross arm M.S. Angle 65x65x6mm V-type
Cross arm holding clamp
Suspension clamp with I-Hook
Dead end clamp with I-Hook
ASCR Ins. Weasel Conductor
Clamps for LT T-off with bolts & nuts
MS Nut, Bolt & Washer
Top Channel
Top Channel (125x65x2240mm)
Dropper Channel (100x50x2028mm) For Fuse Set
MS Angle cross bracing
Clamp with Bolt & Nut
Holding clamp for Top channel, TPMO & Fuse Set etc. with Bolts & Nuts
Straight Through for 3.5x240 Sqmm. XLPE Cable
Outdoor type Jointing Kit for 11 KV 3x120 Sqmm.
Al. Lugs of 240 Sqmm.
Clamp for Distribution Box
LT Insulating connector for Distribution Box connection
ACSR Weasel Conductor for cable support
Stay complete
Digging of pit & erection of new 11 Mtr. long single support ST Pole
Digging of pit & erection of new Double Pole Structure STP Pole (11 mtr. long)
Fixing of MS T-off Channel (125x65x1300mm)
Fixing of X-arm M.S. Angle 65x65x6mm V-type
Fixing cross arm holding clamp
Fixing of Suspension clamp with I-Hook
Fixing of Dead end clamp with I-Hook
Laying of ASCR Ins. Weasel Conductor
Providing & Fixing of Danger Board with clamp for 11 KV
Providing & Fixing Barbed wire
Fixing Clamps for LT T-off with bolts & nuts
Concreting of ST Pole
Concreting of Stay
Concreting of Support
Earthing of Pole by MS Earth Rod
Painting the Pole by Al. Paint
Providing & Fixing Number Plate with clamp and Nut & Bolt
Fixing MS Nut, Bolt & Washer
Fixing Top Channel
Fixing Top Channel (125x65x2240mm)
Fixing Dropper Channel (100x50x2028mm) For Fuse Set
Fixing MS Angle cross bracing
Fixing Clamp with Bolt & Nut
Fixing Holding clamp for Top channel, TPMO & Fuse Set etc. with Bolts & Nuts
Providing & Fixing Al. leg long barrel off size
Providing HDPE Pipe 120mm OD PN-6 PE-100 UV
Laying 3.5x240 Sqmm. XLPE cable inside HDPE pipe by digging/drilling
Laying 3.5x240 Sqmm. LT XLPE cable and connecting with existing LT Panel.
Filling Straight Through for 3.5x240 Sqmm. XLPE Cable
Providing & Fixing Cable end termination using total double compression gland 240 Sqmm.
Fixing Al. Lugs of 240 Sqmm.
Shifting of existing A Type Panel from existing site and installation of Panel by making all connection with it.
Mesh Fencing of existing 400 KVA T/F. h=1.82m x w = 3.25m = 4xhxw = 23.66 Sqmm.
Chemical Earthing of existing A Type Panel
Laying of 3x120 sqmm. AB conductor for LT line on erected poles.
Laying of 11 KV, 3x120 Sqmm. XLPE cable on Pole and testing, commisioning & energization of cable.
Laying ACSR Weasel Conductor for cable support
Laying & Connecting LT XLPE Cable Al. 3.5x400Sqmm.
Laying & Connecting LT XLPE Cable Al. 3.5x240Sqmm.
Fixing Outdoor type Jointing Kit for 11 KV 3x120 Sqmm.
Fixing of Distribution Box
Fixing clamp for Distribution Box
Fixing LT Insulating connector for Distribution Box connection
Fixing of 11 KV Polymer Pin Insulator
Fixing of 11 KV Pin with Nut
Fixing of 11 KV Polymer Disc Insulator
Fixing of 11 KV Disc Fitting
Fixing of Stay
Fixing of 11 KV Fuse Set
Fixing of 11 KV TPMO
Providing & Fixing Copper L-Piece 62x225x12mm
Installation of 250 KV T/F. on Plinth
Dismantling, Shifting and Re-installation of T/F. & Tailless Unit
Complete chemical earthingof 11/0.4 KV, 250 KVA Distribution Transformer by digging pits 6” dia upto 3 mtr. deep including chemical filled pipe in between (pipe-in-pipe) ISI mark B Grade & connecting with G.I strip of size 50mm X 6mm with neutral/body of 11/0.4 KV distribution transformer to above pipe-in-pipe (PIP) and filling of chemical crystalline conductive mixture containing highly conductive material around the (pipe-in-pipe) up to 3 Mtr. including making of chamber at the top of the earthing. Other details are as below:- 1. Earth pipe material – mild steel, Galvanized. 2-Main Electrode diameter – 42.4mm. 3-Auxiliary Electrode pipe, Diameter – 76mm. 4-Wall Thickness of main Electrode: - 2.6mm. 5-Wall thickness of auxiliary hole: - 3.2mm. 6- Length of earthing electrode (PIP):- 3 Meter.
The Construction of new Plinth of Size 2X2X1.5 M = 6 Cumtr.
Mesh Fencing for T/F. h=1.82M x w=3.25m = 4xhxw = 23.56 Sqmm.
Interlocking inside T/F. (3.25x3.25-2x2 = 6.56Sqmm.)
Following material to be Received back to deptt. By dismnatling at site and carriage from work site to Store under the supervision of deptt. Engineer
(A) ST Pole 11 Mtr. Long Old (171 Kg per Pole)
(B) ACSR Dog Conductor Old & Used 720x0.334 = 240.748 Kg.
(C) MS Channel (100x50x5x2240 mm)
(D) 11 KV Cross arm
(E) Existing Line & Poles
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
RTT31.rar
Tender Documents • 0.86 MB
BOQ_2087648.xls
BOQ • 0.27 MB
Ext3111.pdf
PDF • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .