Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹14.2 L (13.3%)Admitted-Finance 39 F NEW REVENUE COLONY ACHALPUR KADIPUR SADAR PRATAPGARH | PRATAPGARH | PRATAPGARH | UTTAR PRADESH | ₹1.2 Cr+₹14.2 L (13.3%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical 00 MUKUNDPUR PAHO DOMANPUR MUKUNDPUR PAHO MIRZAPUR UTTAR PRADESH 231306 | MIRZAPUR | UTTAR PRADESH | 231306 | - | - | Rejected-Technical Technical Bid Not OK |
| Sl No | Description | Qty | Unit | GANGA ELECTRICALS L1 | Shiv Enterprises L2 |
|---|---|---|---|---|---|
| 1.00Supply of Materials | |||||
| 1.01 | PCC POLE 9 MTR | 70 | Nos | 8,999 ₹6,29,930 Lowest | 9,500 ₹6,65,000 |
| 1.02 | PCC POLE 8.5 MTR | 75 | Nos | 4,599 ₹3,44,925 Lowest | 5,000 ₹3,75,000 |
| 1.03 | CONCRETING OF POLE | 145 | Nos | 599 ₹86,855 Lowest | 600 ₹87,000 |
| 1.04 | ACSR Dog Conductor | 10,000 | Meter | 109 ₹10,90,000 Lowest | 200 ₹20,00,000 |
| 1.05 | Stay Set Complete | 30 | Nos | 1,550 ₹46,500 Lowest | 1,600 ₹48,000 |
| 1.06 | M.S. Earthing Rod (2540x20 mm) | 119 | Nos | 799 ₹95,081 Lowest | 850 ₹1,01,150 |
| 1.07 | G. I. Wire 5 mm 8 SWG | 124 | KG | 99 ₹12,276 Lowest | 150 ₹18,600 |
| 1.08 | Cable Al. 3x300 sq.mm. XLPE 33 KV | 350 | Meter | 2,550 ₹8,92,500 Lowest | 2,700 ₹9,45,000 |
| 1.09 | Pin Insulator 33 KV | 138 | Nos | 320 ₹44,160 Lowest | 350 ₹48,300 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
7 Aug 2023, 4:00 pmClosed
Superintending Engineer
Electricity Distribution Circle, Near Electricity Workshop Chilbila Pratapgarh
Work of shifting 33 KV 11 KV LT lines and transformers obstructing the construction of Ganga Express Way under Electricity Distribution Division-II Kunda and Lalganj Pratapgarh on full turnkey basis including loading and unloading of material.
2023_PVVNV_821173_2
09/EDCP/2023-24
Open Tender
Electrical Works
Turn-key
30 days
E.E. EDD-II Kunda
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
S.E. EDC Pratapgarh
₹1.3 L
10 Aug 2023
31 Jul 2023
8 Aug 2023
31 Jul 2023
7 Aug 2023
31 Jul 2023
Amount
Supply of Materials
PCC POLE 9 MTR
PCC POLE 8.5 MTR
CONCRETING OF POLE
ACSR Dog Conductor
Stay Set Complete
M.S. Earthing Rod (2540x20 mm)
G. I. Wire 5 mm 8 SWG
Cable Al. 3x300 sq.mm. XLPE 33 KV
Pin Insulator 33 KV
Pin with Nut 33 KV
Cable Jointing Kit (3x185 sq. mm.) Straight Through 33 KV
Cable Jointing Kit outdoor 33 KV
Disc Insulator (B & S Type) - 70 KN 33 KV
Disc Fitting (B & S Type) - 70 KN 33 KV
T OFF CHANNEL
Cable Al. 3x185 sq.mm. XLPE 11 KV
Cable Jointing Kit (3x185 sq. mm.) Straight Through 11 KV
Cable Jointing Kit outdoor 11 KV
Pin Insulator 11 KV
Pin with Nut 11 KV
Disc Insulator (T & C Type) - 45 KN 11 KV
Disc Fitting (T & C Type) - 45 KN 11 KV
V Type Steel Cross Arm 11 KV (65x65x6 mm)
NUMBER PLATE
TPMO with Polymer Insulator 11 KV
11 KV FUSE SET
Sub Station Base Angle (75*75*6*2028 mm)
Top Channel (125x65x3200 mm) 33 KV
Top Channel (100x50x2240 mm) 11 KV
Dropper Channel
LT Incoming Pannel with metering equipment and fixing arrangement
Stone Pad 300x300x75 mm
G.I. Pipe holding clamp
E Bracket with Bolt & Nut
Danger Board, Barbed Wire including holding clamp for STP
HDPE Pipe 150 mm for underground (6"Dia) 33 KV / 11 KV / LT line
Trenchless cable laying for crossing including cost of sand and bricks
G.I. Pipe 8" Dia
G.I. Pipe 6" Dia
Aluminium Paint
Red Oxide Paint
F Bracket with Bolt & Nut
M.S. Cross Bracing Angle with clamp & Nut & Bolt 65x65x6 mm
LT Shakle Insulator
Top Channel Holding Clamp
Dropper Channel Holding Clamp
V Type Steel Cross Arm holding clamp
T.P.M.O. holding clamp
PG Clamp for Dog Conductor
M.S. Nut & Bolt various size type
ABC CABLE(3*50+1*35+1*16) sqmm
LT CABLE AL 3.5*240sqmm
LT PVC SPACER
ALUMINIUM JOINTING SLEEVES FOR CONDUCTOR
F CLAMP 33KV
33KV CROSS ARM V TYPE
GUARDING ANGLE CLAMP WITH NUT AND BOLT
GUARDING ANGLE
LOOPGUARD COMPLETE THREE PHASE
GI WIRE(7.16mm/6swg)
LT CLMAP
LT SHACKLE STRIP WITH BOLT AND NUT FOR LT SECTION
TAPPING CHANNEL
SUSPENSION CLAMP/ DEAD END CLAMP
EARTH WIRE CLAMP WITH NUT AND BOLT
TF 16KVA
TF 63KVA
TF 25KVA
Errection Work
Construction of Double Pole with 9 meter long PCC Pole for 33 KV Line as per respo norms and carriage of pole dump site to work site.
Construction of Four Pole with 9 meter long PCC Pole for 33 KV Line as per respo norms and carriage of pole dump site to work site.
Construction of Double Pole with 8.5 meter long PCC Pole for 11 KV Line as per respo norms and carriage of pole dump site to work site.
Construction of Four Pole with 8.5 meter long PCC Pole for 11 KV Line as per respo norms and carriage of pole dump site to work site.
Erection of Single 9 Meter long PCC for 33 KV Line with complete fitting as per respo norms.
Construction of Single pole for HT & LT Line on PCC as per respo norms.
Laying of 33 KV Cable 3x300 sq.mm. for road crossing as per respo norms.
Laying of 11 KV Cable 3x185 sq.mm.for road crossing as per respo norms.
Laying of 3.5x400 sq.mm. LT cable for road crossing as per respo norms.
Laying of HDPE pipe for 33 & 11 KV Cable for road crossing
Jointing of 33 KV Cable box 3x300 sq.mm. straight through
Jointing of 33 KV Cable box 3x300 sq.mm. outdoor
Jointing of 11 KV Cable box 3x185 sq.mm. straight through
Jointing of 11 KV Cable box 3x185 sq.mm. outdoor
Laying of ACSR Dog conductor for LT & HT over head line
Grouting and nuzzling & binding of stay set
Cable hosting of double pole/double pole
Dismantling of old and existing line
Laying, Sagging and Binding of ABC CABLE(3*50+1*35+1*16) sqmm as per respo norms
Shiv Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .