Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹8.7 L+₹99,884 (12.9%)Rejected-Finance | L2 | Rejected-Finance Other than L1 after deducting sch of credit Rs 24665.00 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
19 May 2022, 6:00 pmClosed
MAJ SUBIN POULOSE
GE NORTH AKHNOOR PIN181201 CO 56 APO
SPECIAL REPAIR OF REWIRING FITTING FIXTURES AND CONNECTED ITEMS OF BLDG NO P27 P15 FOR OFFICE COMPLEX OF GE NORTH AKHNOOR
2022_MES_519359_1
GE(N)/AKH-06/2022-23
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
Class E Cat b i
8 documents required · 8 mandatory
₹500
Yes
GE NORTH AKHNOOR
₹20,000
Yes
29 Jun 2022
22 Apr 2022
21 May 2022
22 Apr 2022
19 May 2022
6 May 2022
Amount
Taking down carefully aluminium/copper point wiring (light, fan, bell, socket or power) complete, including fixtures and fitting such as switches, ceiling roses, holders, regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement at necessary holes for smooth finishing complete all as specified and removing from site.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through PVC Conduit 20 mm dia medium grade including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. metal flush box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (a) One light point/fan /bell point controlled by one switch. Make of Cables: Havells, KEI, Anchor (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
All as per item no 2 above but for One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
All as per item no 2 above but for One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
Material and labour for point wiring complete with 2.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through PVC Conduit 20 mm dia medium grade including cutting, chasing work at any height and all accessories are concealed in walls/roofs/floors / ceiling etc. metal flush box with top,bottom,side /back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures including 2.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (a) One 15 amps power socket outlet point controlled by one 16 amps switch on independent board. Make of Cables Havells,KEI, Anchor (Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used of same make/brand only and shall be deemed in to included in quoted rate only.)
Supply & fixing modular type switch 6 Amps, single pole, 1way,1 module,240V, ISI Marked complete all as specified and directed. Make Indoasian Glint, Crabtree, Havells REO
Supply & fixing modular type switch 16 Amps, single pole,1 way,1 module, 240V, ISI Marked Complete all as specified and directed. Make Indoasian Glint, Crabtree, Anchor
Supply & fixing modular type socket shuttered type 6 Amps- 2/3 Pin combined 2 module, 240V, AC ISI Marked Complete all as specified and directed. Make Indoasian Glint, Crabtree, Anchor
Supply & fixing modular type socket 6 A/16 Amps -2/3 Pin combined shuttered socket 2 module 240V AC ISI Marked Complete all as specified and directed Make Indoasian Glint, Crabtree, Anchor
Supply & fix fan regulator modular type electronic, stepped type 100 Watts, 2 module 240Volts, AC ISI marked complete all as specified and directed. Make Indoasian Glint, Crabtree, Anchor
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed Make Indoasian Glint, Crabtree, Anchor
Supply and fixing buzzer, ding dong AC, 230 volts single pole complete all as specified and directed. Make Indoasian , HAVELLS
S & F modular bell push 6A , 1 module, 240V, ISI Marked Complete all as specified and directed. Make Indoasian Glint, Crabtree, Anchor
Supply and fixing VTPN verticle loadline double door distribution box (DB) fixed with Bus bar neutral link, blanking plates of 4 way suitable for incomming MCCB 'I/C' frame,having isolated neutral bar, mechanical impact strength IK09,door earthing suitable for MCCB upto 125 Amp Make -Indoasian part No-811888 or its equivalent in Havells Legrand, L&T etc.
Supply and fixing sheet metal enclosure double door type for DBs single pole and neutral 12 way 240 V with 200 Amp bus bar including blanking plates where required . Make : Indoasian, Legrand, Schiender, Havells etc.
Supply and fixing sheet metal enclosure double door type for DBs single pole and neutral 8 way 240 V with 200 Amp bus bar including blanking plates where required . Make : Indoasian, Legrand, Schiender, Havells etc.
Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240 Volts,50Hz , ISI marked complete all as specified and directed (In accordance with IS/IEC 60898-1) 240 V/, 50 Hz, 10 kA Suitable) complete all as specified and directed. Make : Indonesian Cat part No-811114 to 811129 or its equivalent in Havells, Schinieder,L&T.
Supply & fix MCB SPN 63 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed Make - Legrand, Schiender, Havells etc.
M & L for of sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly including making good the disturbed surfaces to match with existing surface including taking down of old existing submain cable complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45cm x 45cm x 45 cm,RCC cover 1:2:4 type B1 of size 45x45x6 cm, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. Note:- The required resistance of Earthing shall be less than 3 ohm, If not found to the required resisstance, the contractor has to re earthing for required resistance and the cost for the same included in the quoted rate and no extra shall be paid on failure of getting required resistance.
S& F LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1200mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) incl taking down existing and deposit with MES all as specified and directed.
Material & Labour for surface & wall mounted LED tube light fitting 10 W, 2 feet long extruded PVC housing provided for efficient heat dissipation to polycarbonate diffuser & integrated electronic driver with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make- Havells cat part No ENDURALINEARNEOBS10W LED865SPCWH OR equivalent in Philips/ Crompton/ Bajaj/ Wipro/Syska LED/GE lighting/Surya.
Taking down old unserviceable Exhaust fan of any type/size from existing location and deposit in MES store yard and Supply and fix exhaust fan single phase metal body, AC 230 Volt, 50 Hz of size 300mm sweep with louvers shouter complete with all accessories including connecting up from ceiling rose to motor all as specified and directed. Make- HAVELLS/BAJAJ/CROMPTION etc
S & F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S & F 20 watt LED batten with battery/inverter capacity having charging time 8 hour, driver efficiency > 85%, power factor > 95% and operating voltage 270 volt Make - Halonix or equivalent in make Philips, Bajaj
Supply and fix Single pole and netural enclosure with two pin and earth plug and socket with one single pole MCB of capacity 20 amp 240 volts and connecting electrically including taking down unserviceable MCB complete all as specified. Make : Legrand, Schiender, Havells etc.
Supply and fixing LED luminaire 600 mm X 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply, laying and testing XLPE insulated electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 95 Sqmm 3.5 core connected with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipes including taking down old existing unserviceable cable complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately) Make POLYCAB, GLOSTER, GRANDLAY
S& F GI pipe light grade 50 mm bore for cable protection fixed on poles or laid in trenches under floor, ducts etc with fixing clamps, nuts, bolts etc all as specified.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep in soft/loose soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
M&L for protection to cable with one layer of brick laid flat across the cable using all size sub class 'B" Bricks.
Sand cushioning to under ground electric cables including watering and consolidation all as per clause 19.75 of SSR Part I
Supply, fabrication and fixing feeder pillar box of size 500x450x500mm made out of MS sheet of 3.15mm thick bent to shape & size factory made with welding, bending works suitable for including 200 Amps rated aluminium bus bars (length of bus bar not less than 40 cm) 4no's, making holes of required size and mounted on porcelain/epoxy based post insulators of appropriate size with suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and length of angle iron not less than 1 mtr, 0.5mtr to be embeded in PCC below G.L and 0.5mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide primer and incoming/out going cable connections with required size of cable lugs with proper crimping. Make:-Make DVEPL, Electrifield, Siemen.
Taking down old desert cooler from site and deposited with MES Yard and supply and fixing metal body desert cooler fabricated with 22 gauge sheet spray painted incl shutter made up of 24 Guage sheet incl complete accessories all as specified and directed.
Jiwan Singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .