Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹150.7 CrAccepted-AOC PLOT NO 110 2 CRYSTAL BUILDING SHARE PUNJAB COLONY ANDHERI EAST MUMBAI 400093 | ₹150.7 Cr Quoted ₹1 | L1 | Accepted-AOC L1 |
| 2 | L2₹2Rejected-Finance | ₹2 | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical RAM PLAZA NAVASHAKTI CHOWK BHABHA NAGAR NASHIK 422 011 | NASHIK | NASHIK | MAHARASHTRA | 422011 | - | - | Rejected-Technical Disqualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
| 5 | Rejected-Technical THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | - | - | Rejected-Technical Disqualified |
Tender Value
₹143.6 Cr
EMD Value
₹71.8 L
Closing Date
10 Feb 2023, 6:15 pmClosed
Executive Engineer, North Mumbai (P.W.) Division
Executive Engineer, North Mumbai (P.W.) Division, Andheri , Mumbai , Administrative Building , First floor , Near Bhavans Collage , Andheri 400058
Construction of Proposed New Rest House in Government Colony at Bandra East, Mumbai for Government of Maharashtra
2022_PWR_862575_1
NIT_NO_87_FOR_2022_23
Open Tender
Civil Works
700 days
Bandra
As Per Tender Documents
4 documents required · 4 mandatory
₹5,900
₹71.8 L
Chief Engineer, Mumbai P.W. Region, Mumbai
17 May 2023
27 Dec 2022
14 Feb 2023
27 Dec 2022
10 Feb 2023
14 Jan 2023
27 Dec 2022 - 10 Jan 2023
10 Jan 2023
Amount
Civil Works
Providing and Casting RCC bored cast in-situ Vertical as per IS 2911 (Part 1, Section 2) by boring through all kinds of soils/ Sand /Rock by rotary hydraulic rigs using temporary casing up to stable strata / bentonite mud circulation as specified, from tip to cut-off elevation of piles. Reinforced Cement Concrete work of filling the bore (after placement of reinforcement cage as per drawing) with M30 grade Ready Mix Concrete using 43 Grade Ordinary Portland Cement confirming to IS : 8112, of approved make and brand with minimum cement content of 400 kg/m3 and with water -cement ratio, including the water contained in aggregates (10mm to max 20mm size), not exceeding 0.45, with approved plasticizer as specified, including placing of concrete from tip to minimum of 600mm above the specified cutoff level, breaking pile head to cutoff level and exposing pile reinforcement for embedment in pile cap, Disposing & levelling of bored/excavated material suitably at locations approved by the local authorities including all lead and lifts, all complete for piles having diameter of (Pile will be measured for payment for length between pile tip to cut-off level along the pile axis. Reinforcement shall be paid separately) Diameter of pile is 600 mm. Note : Cost of temporary casing shall be incurred by the Contractor.
Inclined Rock Anchor - 112 Ton Providing, Installing and testing of inclined rock anchor of specified capacity at all levels inclined at an angl, fixed length & free length mention in drawing throogh hole of diameter as mentioned in drawing with anchor drilled with specifiied spacing by consultant, HT strands - Class II of 12.7 mm Dia of TATA/USHA MARTIN makewith three coats of epoxy coating and bottom 200 mm length of cable shall be grouped in MS cone with epoxy coated MS spacer at regular interval with lock of load as mentioned including MS casing for free length including grouting with conbrextra GP2 for fixed length and grouting free length with cement and cebex 100 grout with minimum strength of M25 grade as per consultant requirement. The rate inclusive of providing bearing plate, Wedges, stressing, stagging and supporting work and locking the strand for load, Sprinkle quartz sand on epoxy coated strand for bonding, pull out test wherever required etc. complete all as per approved construction drawing, specification and as dirtected by EIC/Consultant.
Inclined Rock Anchor - 97Ton Providing, Installing and testing of inclined rock anchor of specified capacity at all levels inclined at an angl, fixed length & free length mention in drawing throogh hole of diameter as mentioned in drawingwith anchor drilled with specifiied spacingby consultant, HT strands - Class II of 12.7 mm Dia of TATA/USHA MARTIN makewith three coats of bepoxy coating and bottom 200 mm lengthof cable shall be groupedin MS conewith epoxy coated MS spacer at regular interval with lock of load as mentioned including MS casing for free length including grouting with conbrextra GP2 for fixed length and grouting free length with cement and cebex 100 grout with minimum strength of M25 grade as per consultant requirement. The rate inclusive of providing bearing plate, Wedges, stressing, stagging and supporting work and locking the strand for load, Sprinkle quartz sand on epoxy coated strand for bonding, pull out test wherever required etc. complete all as per approved construction drawing, specification and as dirtected by EIC/Consultant.
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
Providing and fixing the Mechanical Anchor Fasteners as specified below of Hilti Make or equivalent confirming to IS 1367 (Part 3) at required locations and level including drilling the hole, cleaning and anchoring the bolt as per manufacturers specifications etc. complete as directed by Engineer In Charge. e) M20
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means.
Excavtion In soil (Lift upto 1.5 m)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m) By Mechanical Means.
Excavtion In soil (Lift from 1.5 m to 3.0 m)
Excavtion In soil (Lift from 3.0 m to 4.5 m)
Excavtion In soil (Lift from 4.5 m to 6.0 m)
Excavation for foundation in Hard rock by chiselling, wedging, linedrilling ,etc. including trimming andl evelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and backfilling with available earth/murum watering, ramming etc. complete. (Below 6 m). By Mechanical Means
Excavation in Hard Rock (Lift from 6.0 m to 7.5 m)
Excavation in Hard Rock (Lift from 7.5 m to 9.0 m)
Excavation in Hard Rock (Lift from 9.0 m to 10.5 m)
Excavation in Hard Rock (Lift from 10.5 m to 12.0 m)
Excavation in Hard Rock (Lift from 12.0 m to 13.5 m)
Excavation in Hard Rock (Lift from 13.5 m to 15.0 m)
Excavation in Hard Rock (Lift from 15.0 m to 16.5 m)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved. for 50 Km Lead.
Providing preconstructional antitermite treatment as per S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyri fos per square meter surface area covering 10 years guarantee on bond paper. Spec. As directed by Engineer in charge.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at 15 cm c/c as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper. As directed by Engineer in charge.
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade).
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
Providing and fixing in position HCRM/CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pilecaps, footings, foundations, slabs, beams, columns, canopies, staircase, newels,chajjas, lintels pardis, copings, fins,arches etc. as per detailed designs,drawings and schedules including cutting, bending, hooking the bars,binding with wires or tack welding and supporting as required complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing parallel threaded couplers conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”, to reinforcement bars including threading, enlargement at connection by forging, protecting the prepared reinforcement bars and related operations as required to complete the works per direction of Engineer- in-Charge.
Coupler for 20 mm diameter reinforcement bar
Coupler for 25 mm diameter reinforcement bar
Coupler for 32 mm diameter reinforcement bar
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including steel centering, formwork, precast concrete cover blocks of same or Higher Grade, laying /pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, precast concrete cover blocks of same or Higher Grade, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, precast concrete cover blocks of same or Higher Grade, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
300 mm Thick
450 mm Thick
600 mm Thick
Providing and laying Cast in situ / Ready Mix cement concrete M-50 of trap / granite / quartzite / gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, precast concrete cover blocks of same or Higher Grade, laying / pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finishis to be provided and curing etc. complete, (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc.complete.With fine aggregate (Crushed sand VSI Grade)
Upto 1st Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-40 of trap / granite / quartzite / gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, precast concrete cover blocks of same or Higher Grade, laying / pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finishis to be provided and curing etc. complete, (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc.complete.With fine aggregate (Crushed sand VSI Grade)
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, precast concrete cover blocks of same or Higher Grade, laying/pumping, compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.complete. With fine aggregate (Crushed sand VSI Grade)
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, precast concrete cover blocks of same or Higher Grade, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement, including precast concrete cover blocks of same or Higher Grade. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Designing, providing and laying in any position, without usage of vibrator, ready mixed design mix Self Compacting Cement Concrete (SCC) of required grade for Form Finished reinforced cement concrete work in super structure at all floor levels, using cement & fly ash, content as required including transportation of concrete through transit mixer to site of laying for all leads, all floor levels, pumping of concrete to site of laying but excluding the cost of centering, shuttering, including admixtures conforming to IS 9103 as per designed proportions to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. The Mix design as per particular specfications shall be got approved by Engineer-in-Charge before execution of the item.The rate shall include cost of all specified materials and operations , but exclude the cost of centering, shuttering and reinforcement which shall be paid under relevant item.
M-30 Grade SCC
Above 1st Floor to 12th Floor and Terrace Floor
Providing & Supplying corrosion inhibiting admixture in concrete to protect steel bars for all concrete in every part Polyalk CP 293 of approved make & approved by Engineer in charge migrating, non nitrite based corrosion in hibiting admixture shall be added at adose of 3 kgs per cum of concrete. The admixture should protect both cathodic and anodic sites and have been accredited by Indian Roads Congress, recommended for use by Ministry of Road Transport & Highways and should have a 4 year track record of use in both the Gulf Region and India. Admixture should have evaluated test reports demonstrating a corrosion rate of zero coulombs after 9 test cycles as per ASTMG 109 when tested from are search institution NBA accredited Grade A and internationally ranked among top 5 research institutions in the world in Annual Survey conducted by Georgia Institute of Technology ranking of research institutions. PH of admixture should be alkaline in nature, specific gravity of 0.99 – 1.1, colour: brownish. The contractor must intimate the engineer in charge prior to addition in concrete for recording. If the admixture is put in the concrete mix at the batching plant, a written record of the amount of admixture used shall be supplied to the engineer. The engineer must ensure that the specified dosage of admixture is added in the concrete mix.
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layersincluding watering and compacting etc. complete.
Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen/using cement with waterproofing compound curing, formwork etc. complete.
Upto 1st Floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
200 mm Thick Wall
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
150 mm Thick Wall
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
100 mm Thick Wall
Upto 1st Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. As directed by Engineer in Charge
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing internal / external 12 mm thick Ready Mix plaster confirming to IS:4031 (Part-4) 1988 and IS383 -1970 in a single coat using Cement mortar of proportion 1:4 containing special type of polymer additives about 0.4%, to all type of surfaces in all positions including scaffolding and curing complete. As directed by Engineer Incharge
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part - 1 & II) 1976, applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.
Upto 1st Floor
Providing and applying white-wash in two coat on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing false ceiling with eco-friendly light weight calcium silicate tiles of Spintone/cosmos surface textured "Aerolite " make or equivalent of size 595 x 595mm having 15 mm thick densified microlook edge and 100% humidity resistence, incombustible as per BS 476 Part IV and thermal conductivity 0.043 w/m° and NRC 0.50 placed in true horizontal level suspended grid of size 600x600 mm made from hot dipped GI steel sections on Sillhoutte profile, rotary stitched double webbed white with 6mm reveal profile (white/black), where in main T runner of size 24 mm x 38mm and 0.33 mm thick @ 1200mm center to center and cross T of size 24mm X 28 mm and 0.33 mm thick, 1200 mm long spaced between main tee at 600 mm centre to centre and secondary cross T of Size 24mm X 28 mm x 0.33 thick of length 600 mm to be inter locked at middle of the first cross T in each panel to form grids of 600 mm x 600 mm and resting on periphery wall profile wall section 24 mm x 24mm x 0.40 thickness and laying false ceiling for services like diffusers grills including cutting, making opening for light fitting, fixtures, smoke detectors etc. wherever required, main tee runner to be suspended form ceiling using G.I. soffit cleats of size 25 x 35 x 1.6 mm of required length fixed to the ceiling with12.5mm dia and 50 mm long dash fastener, 4 mm dia G.l adjustable rods with good quality G.I level adjustment clips of 85 X 30 X 0.8mm spaced at 1200 mm center to center along main tee all complete at all heights as per specifications, drawings and as per direction of Engineer - in - Charge.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vIrgin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. As directed by Engineer in charge
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and applying two coats of protective membrane over the cured concrete surface like R.C.C. footings, columns, plinth beams etc. which will be submerged under soil so as to protect the same. Apply two pack coal tar epoxy system of Sunepoxy Coaltar of approved make & approved by Engineer in charge, having solid content ranges from 80-100%, Tack free time 4-6 hrs. Recoat after 16-24 hrs. Mix Part A and Part B of Sunepoxy Coaltar of approved make & approved by Engineer in charge in 1:1 ratio with slow speed stirrer and apply the same on a clean R.C.C. surface by brush. Allow to set for 8-10 hours and apply the second coat. The rate to include for application at all levels to various RCC elements to the satisfaction of the EIC etc. complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles)
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying waterproofing tratment of 112 mm average thickness consisting of 12 mm thick layer in cement mortar 1 : 4 with water proofing compound at the rate of 1 kg per bag of cement as base, constructing and laying brick bat coba in cement mortar 1:5 with waterproofing compound at the rate of 1 kg per bag of cement and having average thickness of 80 mm and finishing with 2 mm thick cement plaster layer in cement mortar 1:4, aterproofing compound at the rate of 1 kg per bag of cement bag, laying in required position flooring of broken China mosaic (broken pieces of China chips) of approved colour and pattern including neat cement float, giving proper slopes, compaction, curing, finishing preparing bell mouth etc. including all lead , lifts and laid to proper slope to drain off water entirely including watta, Bell head or Champhered portion at the junction of parapet and work upto a height of 300 mm or as directed and covering the whole treatmnet with yten years guarantee, on requisite stamp paper etc. complete.
Terrace Water Proofing
Providing and applying a base coat comprising of 1 KilogramPolydee-MC and 1Kilogram fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2A :1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying machine cut and mirror polished approved coloured ITALIAN MARBLE SLAB approved size, 20 mm +/- 2 mm thick of approved quality with approved qality, Italian marble inlays for flooring in required pattern on a bed of 1:4 cement mortar 25- 30 mm average thickness including neat cement float, filling joints with neat coloured cement slurry, curing, polishing and cleaning complete. ( Basic rate of ITALIAN marble Rs. 10,000/- per Sq.M) of Beige Botticino, Crema Marfil, Grey Fiasco, Spanish Grey, Light Emperador, Armani Grey
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
Above 1st Floor
Providing and Laying Fully vetrified mirror / glossy finish Tiles having size 1000 mm x 1000 mm size tiles of 10 to 12 mm thickness and confirming IS. 15622-2006 of approved make, shade, pattern, double charge for flooring in required position laid on bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying vitrified mirror /glossy finish tiles having size 600 x 1200 mm of 8 to10 mm thickness and confirming to IS.15622 -2006 (group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete - 600 X 1200 MM Size Dado Tile
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and laying telephone black / Amba White / Cadbury brown / Rubyred / Ocean Brown granite stone of 18 to 20 mm thick for door frame / dado / window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges where ever necessary, curing, etc. complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing machine cut and mirror polished approved coloured ITALIAN MARBLE CLADDING with inlays of approved size,20mm +2mm thk. Of approved quality for required patternon a bed of 1:4 CM 25mm average thickness including neat cement float,filling joints with neat coloured pigment, curing, polishing and cleaning etc.complete. (Basic rate of ITALIAN marble Rs.10,000/-per Sq.M) of Beige Botticino, Crema Marfil, Grey Fiasco, Spanish Grey, Light Emperador, Armani Grey
Upto 1st Floor
Above 1st Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Fire Door 55 mm 2HR FRL (120/120) 3 Criteria-INTEGRITY/ INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2.
Providing of 120 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature").
a) Door Frame: Supplying & Fixing frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 Kilogram/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
b)Shutter : Supplying & Fixing of 55mm thick asbestos free criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 Kilogram/cum) frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128 Kilogram/cum), vermaculite mix faced with 3mm Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10mmx4mm affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
c) Vision Panel: 2 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 mm inside the shutter on all sides with U- glazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
d) Panic Bar: (For 2 Hr fire Rated single Panic bar) Supplying, fitting & fixing Surface mounted Crash Bar/ panic Bar of touch pad style ,made of heavy duty cast iron/ steel body & latches with SS ,BHMA certified & conforming to ANSI A 156.3 for grade-1 ( 3 hours fire rated ) and suitable for surface mounting to wooden/hollow metal/ Al framed door,with maximum operating force 8Kilogram for unlocking easily & outwardly during emergency,complete in all respect as per direction & satisfaction of Engineer-in charge including all taxes & incidental charges. (Note: To be installed at "FIRE EXIT"only under location specific instruction of Eingineer-in -Charge.)
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
e) Door Closure: (For 2 Hr fire Rated EN-3 Door Closure) Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors of different size (e.g size -EN-3 for leaf width upto 900mm) CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.) fitted and fixed Complete as per direction & satisfaction of Engineer -in Charge including all taxes & incidental charges.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
f) 12"SS Handle: (For 2 Hr fire Rated 12"SS Handle) Supplying, fitting & fixing Stainless Steel 'D' or 'H' type of size 300 mm x 19 mm tubular Handle with Grade 304, CE certified, marked & conforming to EN - 1154 of approved quality (Internationally reputed brand like Dorma, Geze, Hafele, Assabloy & Magnum etc.)as per direction of Eingineer -in Charge fitted and fixed complete including all taxes & incidental charges.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing solid core flush door shutter in double or single leaf 50 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, moulding sand lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. including Providing and fixing vision panel of size 300mm x 300mm in door with 6mm thick glass including T.W. beading etc. complete as directed by Engineer in charge.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983).
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and Fixing to frames 30mm thick Fiber glass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856 : 2000 etc complete as directed.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Design, fabrication & Installation of FRP LOUVERS with 30 mm clear space including aluminium EURO support system for accommodating FRP louvers consist of aluminium angle brackets of 50 x 50 x 5 mm with EPDM gaskets & anchor fastners (HILTY make) etc. Louvers as design including 60 mm x 30 mm section UPVC FINS & as per Architect/Engineer incharge
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing frame with /without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron hold fast of size 300 mm x 40mm x 5mm with oil painting, etc. complete
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.
Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm).
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing factory made uPVC white colour fixed glazed windows / ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).
Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing in position aluminium openable window of any size as per detailed drawing and as directed by Engineer in charge with all necessary alluminium sections including necessary fixtures and fastening with 5 mm thick clear float glass etc. complete. a) Colour anodized
Above 1st Floor
Providing & fixing S.S. pipe hand rail along the wall in staircase orramps or passages consisting of 50 mm dia. 18 gauge 304 grade stainless steel pipe. Supported with 25 mm 18 gauge S.S. pipe(304grade) brackets & 5mm thick tapered edge coller base plate fixedto wall with SS screws at approx. 600 mm center to center fixedhorizontally or in inclined position at required height including grindingthe welded joints, buffing,protecting the railing members by means of wrappers during construction etc. complete as per detailed drawing as directed by the Engineer in charge.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with miner alturpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applying wall primer with brush with mineral turpentine 8 to 10 % and oil 15 to 20 % with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush / rubber / spray with mineral turpentine 7 to 9 % and Oil with roller 19 to 21 % After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21 % after allowing dry for the period of 6 to 8 hours activity. As directed by Engineer in charge. As directed by Engineer in charge.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and applying fibre added elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in two coats @10 litre/ 10 sqm. One coat of selfpriming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and second coat of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 200 microns). Followed by single coat of Silicacisous fiber reinforced 2 mm scratch finish Texture coat, to be top coated with two or more coats of Organo-Silicon, UV Cross linking emulsion Paint having high resistance to algae growth & Shade fading, Superior DPUR and protection against bird dropping with Paint performance of 10 years of approved manufacture and of approved colour to new plastered surface/ Concrete surfaces including scaffolding. If necessary, cleaning and preparing the surface, water for two days etc, Complete.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providign and fixing in position factory made precast Glass fiber reinforced concrete (GRC) as per approved manufacture's specification and as per approved drawings. The thickness of GRC panel should not be less than 20 mm with minimum 20 mm thick GRC pads acting as stifners. Colour and tecture should be approved by Engineer incharge. Fixing of GRC panel on primary structure shall be doen by dry claddign method with the help of SS screw/ nut bolts fixtures, MS angle cleats, fissurs plug and Dowel pin etc. in porper alignment, line and level as per the approved drawing, Finishng with GRC powder fillign the joints with paintable silicon sealant neatly between GRC panel and primary strcutre to provide one piece look including moulding and cornice at junction of column and beams as per approved drawing, includign necesary MS fabrication work to support GRC strcuture, necessary scaffolding at all levels and staging etc. Complete includign cost of necessary machineries for installation, all necessary accesories, adhesives, hardware, cost of material, labour, transportation, scaffolding, loading, unloading all leads and lifts and all applicable levies, taxes, maintainance upto one year from the certifed date of completion etc. complete as per apporved drawign and as directed by engineer.
Upto 1st Floor
Design, supply, fabrication & erection of approved structural glazing using specially designed Vertical Mullion & Horizontal Transoms of Required size & as per architect's approved Grid work with aluminium rectangular sections to be fixed in masonary at interval of each floor on concrete slab with 80 mm x 100 mm x 5mm thick galvanized M & Langle fixed on wall side with raw bolt size of 10 mm x 90 mm with necessary bolts & washers / nuts for the plumb the linelevels. the glass panel's shall be fixed on a specially designed architectural sub- frame using Dow Corning 995 strural sealant & GE Silicon (SSG - 4000) sub frame would be fixed on main frame grid in amanner that no aluminium frame is visible from outside & groovesbetween the glass panel shall be filled with weather sealant of Dow corning 789 / GE Sil proof to made it air tight, water proof & dustfree thus giving it a flush look outside. Glass will be of 6 mm thick Glaverbel reflective type with heat strengh ened toughened.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing glazing panels & doors using 12mm thk toughen clear glass (confirming to ASTM Standards C-1048) supported bycchannel (embedded in the floor) at the bottom & side edge and wall connecting profile at the top edge,stainless steel articulated countersunk bolts threaded bolts,chemical fasterners,etc., glass panel size as per design and drawing including applying colourless sealant of joint incl. required edge polish, making glazing water tight etc. Destructive node joint test reports to be submitted for establishing the safety factor, including operating hardware, SS patch fittings, fabricated long length satin finish SS 304 handles,patchlock, floor springs etc., complete as directed by the architect for frameless patch doors,single or twin leaf shutters with fixed panel on top. Hardware-Droma BTS 80 Floor Spring.
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material
Wet Mix Macadam -- Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Laying By Grader/Paver.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.
White topping on concrete overlay for Urban road Construction of Thin White Topping plain cement concrete pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, replacing cement by fly ash to the extent of 15 per cent and sand by 10 per cent, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, construction and longitudinal joints with panel size of 1m X 1m, joint filler, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, polypropylene fiber as approved, curing compound, finishing to lines and grades as per drawing
Providing and fixing of cement concrete Kerb Stone of various grades of size : 500 mm width x 325 height x 165 mm thick (Half Batter, Bull Nose / Full Batter) manufactured in wet press vacuum dewatering technology plant /equivalant with face pimple finish for high visibility with excellent quality and finish and edges perfect and sharp. Grade – M-25 including excavation in any soil except rock, laying leveling course of M15 grade RMC100 mm thick to required slope (inclusive of formwork),jointing in C.M.1:2 proportion flush to concrete surface, painting exposed surface with one coat of primer and two coats of 1st grade road marking paint in the yellow /white /black or any shade as directed. (Kerb stones shall be procured from MCGM registered agencies).
Providing and fixing 50 mm thick precast concrete interlocking paving block of concrete grade M30 for non traffic areas like footpath, paving etc. and as per the approved size, pattern, shape, colour, make, conforming to IS 15658, including 30mm thick sand bedding and edge confinements in cement mortar 1:3, laying in perfect line and grade etc. complete.
Space-frame with Laminated Glass on Top of Atrium Space-frame with Laminated Glass on Top Design, Supply, Fabrication & Erection of Space-frame structure over atrium made up of tubular members, nodes, props, high tensile bolts, plates, sleeves etc. duly painted with one coat of suitable primer & 2 coats of PU paint which shall be cladded with 13.52mm thk clear laminated glass (6mm thk clear toughened glass +1.52mm thk PVB lamination + 6mm thk clear toughened glass) with the help of necessary aluminum sections, epdm, screws etc. as per above specifications.
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted /bolted /welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. (Bd.C.8 Page Number 278)
Directional signage: Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6" x 9" designed as per accessibility standards and having 4 mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15 mm raised not less than 0.8 mm above base plate and the equivalent word written in Hindi with Devnagrin on glare acrylic letters of height 15 mm raised not less than 0.8 mm above base plate and having a non glare acrylic cut arrow pointing in there quired direction. Each sign board to be fixed as per manufacturers specifications on the wall at the approved location an data height of 1200 mm from FFL and as per the directions by the engineer in charge. As directed by Engineer-in-charge
Fire exit and floor identification signage as per manufacturer's specifications, ADA compliant and modular system, As directed by Engineer-in-charge
Providing & Fixing corner guard for columns at parking area size W100 x H800 x 8mm colour: Black with yellow or White Reflective Stickers Body Material: Modified Thermoplastics (Polymer Rubberized) Fixing: Fixed on the wall & corner of columns with six 2" Screws.
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by each 547 ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire, Serrated with central bulb (225 mm wide, 8-11 mm thick)
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing and fixing Speed Breakers of Size 350 W x 500 L x 50 H mm yellow black color as shown in the drawing with necessary fittings & fixtures as directed by EIC.
Foundation Passive Rock Anchor : Drilling hole of 150 mm Dia. in hard rock Including all labour & Machinery as per design upto 8 Mtr Depth from Raft PCC level. Grouting by Conbextra Fosroc GP 2 as per design. Anchor capacity 75 T
Invisible Grills - Providing & Fixing invisible grills with alluminium track uses 316 marine grade stainless steel for the cables manufactured with 7 x 7 nano technology with 0.3 mm nylon coating. Specs- Load Capacity - 250 Kgs / Plus Space - 1.5 inch No hot work/ No Welding
Upto 1st Floor
Above 1st Floor to 12th Floor and Terrace Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
For Municipality Inlet connection
Providing and making ISI Mark ferrule connection of 50 mm dia. To water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
Supplying and installing cast iron Butterfly valves PN 16 completewith both sides including flanges on receiving pipes with nuts, bolts,1.5mm thick compressed asbestos gasket insertion as required.65 mm dia.
For Municipality Inlet connection
Providing and fixing 50mm diameter water meter with non-return valve including strainer,sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber] (Bd.V.7 Page Number 554)
For Municipality Inlet connection
Supplying & fixing 600 mm (24") to 750 mm (2'-6") long screwed G.I. C class pipe with 3 mm thick M.S. bar flange (plate) welded on it: Flanges should be of Table E of approved make. (Puddle Flange) a) 65 mm(2 1/2")dia pipe 5 mm thick with 150X 150(6" X 6") plate, Both ends Flanged.
For Municipality Inlet connection
Supplying & fixing 600 mm (24") to 750 mm (2'-6") long screwed G.I. C class pipe with 3 mm thick M.S. bar flange (plate) welded on it: Flanges should be of Table E of approved make. (Puddle Flange) d) 150 mm(6")dia pipe 7 mm thick with 300 X 300 (12" X 12") plate, Both ends Flanged
For UGT Over flow
Providing and Fixing of 80mm dia Cast Iron Foot valve for Domestic pump suction in UGT
For UGT Suction
Providing and Fixing of 50mm dia Cast Iron Foot valve for Flushing pump suction in UGT
For UGT Suction
Supplying and installing cast iron Butterfly valves PN 16 completewith both sides including flanges on receiving pipes with nuts, bolts,1.5mm thick compressed asbestos gasket insertion as required.80 mm dia.
For UGT Pump room
Providing and Fixing of 80mm Dia Cast Iron Y Strainer for Domestic delivery line in domestic pump in UGT Pump Room
For UGT Pump room
Providing and Fixing of 50mm Dia Cast Iron Y Strainer fo Flushing delivery line in domestic pump in UGT Pump Room
For UGT Pump room
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.
For UGT pump to OHT Fire tank
75 mm nominal inner dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.
For UGT pump to OHT Flushing tank
50 mm nominal inner dia Pipes
Supplying & fixing 600 mm (24") to 750 mm (2'-6") long screwed G.I. C class pipe with 3 mm thick M.S. bar flange (plate) welded on it: Flanges should be of Table E of approved make. (Puddle Flange) b) 75 mm(3")dia pipe 5 mm thick with 200 X 200 (8" X 8") plate, Both ends Flanged
For OHT Fire
Supplying & fixing 600 mm (24") to 750 mm (2'-6") long screwed G.I. C class pipe with 3 mm thick M.S. bar flange (plate) welded on it: Flanges should be of Table E of approved make. (Puddle Flange) c) 100 mm (4")dia pipe 5 mm thick with 250 X 250 (10" X 10") plate, Both ends Flanged
For OHT Fire
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
For Shaft water supply
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
For Shaft Water supply
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
For Shaft Water supply
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
For Toilet Water supply
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
For Toilet Water supply
Providing, fixing and testing heavy quality gun metal or brass ball valve with screwed ends 20kgm class on GI or copper pipe lines (Leader/ZOLOTO make) 50 mm (2') dia.
For Shaft Vertical Entry
Providing, fixing and testing heavy quality gun metal or brass ball valve with screwed ends 20kgm class on GI or copper pipe lines (Leader/ZOLOTO make) 40 mm (1 1/2") dia.
For Shaft Vertical Entry
Providing, fixing and testing heavy quality gun metal or brass ball valve with screwed ends 20kgm class on GI or copper pipe lines (Leader/ZOLOTO make) 32 mm (1 1/4") dia.
For Shaft Vertical Entry
Providing, fixing and testing heavy quality gun metal or brass ball valve with screwed ends 20kgm class on GI or copper pipe lines (Leader/ZOLOTO make) 25 mm (1") dia.
For Shaft Vertical Entry
For Toilet
d) 100 mm dia
For Toilet
c) 75 mm dia
Providing and fixing 8 cm rigid PVC Nahani trap including PVC grating ,bend, connecting piece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)
For Toilets
Providing & Fixing 100mm diameter Nahani trap Jali in steel finish with necessary fixing required to make the item well functional.
For Terrace,Toilet and Balcony
e) 150 mm dia
f) 200 mm dia
Providing and fixing European type white glazed earthen ware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the out side face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps, 20 mm dia. UPVC over flow pipe, mosquito proof couplings G.I. chain and pulley, with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete. (prior approval of sample and brand by Ex. Engineer is necessary before use)
Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall.
For GF Toilets
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
For Internal toilets
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore
For Internal Toilets
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete.
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge
Providing and fixing Shower Head with shower arm of approved make shower tube hand shower with divertor of spout including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.
For Internal Toilets
Providing and fixing Health Faucet with one metre long easy flex tube in chrome finish and wall flange
For Internal Toilets
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete."
Providing and Fixing of sink cock for kitchen and Pantry AREA
Providing and fixing toilet paper holder : C.P. Brass
For Toilets
Providing and fixing ISI marked make CP brass liquid soap dispensers with CP brass bracket capacity 250 ml.
For Bath area
Providing C.P.Towel rail 24" jaquar make continental (Cat. No. ACN 1111N )
For Bath area
Providing and fixing JAQUAR MAKE metropole flush valve Dual Flow Concealed type with control cock operation plate 40 mm size etc. Complete
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing , constructing and fixing 250 mm dia. Inspection chamber made up of UPVC material of thickness 3.5 mm and height of 259 mm with inlet and outlet of 110 mm dia. with 75 mm dia. U Trap, Ultra shaft pipe of Upvc material having height of 470 mm and fixing Ultra 250 mm dia. UPVC cover and frame in 150 mm thick in c.c.1:2:4, having crushed sand bed of 100 mm thick of size 550 mm dia. Including excavation and refilling the sides of chamber by crushed sand cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete.
Providing , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450 mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete.
Providing , constructing and fixing 600 mm dia. Inspection chamber made up of Polypropylene / polyethylene material Having 315 mm diameter nlet(s)/outlets and with eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of 5 mm and 600 mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete.
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete.
Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover medium duty 140 kg. etc complete
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight with 75 mm thick R.C.C. cover medium duty 140 kg etc. complete.
Providing and constructing Ductile Iron circular manhole 45 cm dia. At top 90 cm at bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15 cm thick burnt brick mansonry with 1:1 cement mortar plaster 25 mm thick inside and outside 20 mm (1:3) ductile iron heavy type cover with ring 125 kg in weight. High strength. More life and Durability, Good Antiskid Grip, Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25 m deep borewell at the floor of recharge pit including installation of combination of solid/ perforated PVC casing pipe wrapped around with netlon mesh including 300 mm thick side filling around outside of RCC rings (annularspace) with 40 mm size boulders including filling of recharge pit upto 0.5 m depth with 25 -75 mm clean washed gravels from bottom up followed by 0.5 m depth of 10- 25 mm of clean washed stones followed by 0.5 m of washed river fine aggregate (naturalsand/ crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/ fine aggregate (naturalsand/ crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, man hole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in Charge.
Supply & installation of 600mm Wide heavy duty FRP covers with required accessories & fittings.
Construction of trench 450mm wide X 450 depth in masonry for Rain water line with 150mm thick wall resting on 1:4:8 concrete foundation with 6" PCC M15 benching with desired channel alignment. The inside face to be smooth plastered with 15mm thick plaster of cement mortar 1:2. with with required FRP cover.
Civil Works Total PART - A
Material Testing
Basic Test of Cement
Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness.
Basic Test of Agreegate
Water Absorption, Specific Gravity,Impact Value, Crushing Value.
Sieve Analysis.
Flakiness Index & Elongation Index.
Basic Test of Fine Agreegate
Fineness Modulus ( Sieve Analysis ),Silt & Clay Content
Chloride & Sulphate Content.
Silt Factor.
Basic Test of AAC BLOCKS
Density Test . (Set of 3 Blocks ),Compressive Strength. (Set of 3 Blocks ),Water Absorption Test ( Set of 3 Blocks )
Basic Test of Concrete
Compressive Strength of C.C. Cube (Set of 3 cubes).
Concrete Mix Design (With all Tests on basic materials)
Permeability Test.
Concrete mix design by Accelerated curing method. (By Accelerated curing method)
Basic Test of Mortar
Compressive Strength.( Set of 3 Cubes)
Basic Test of Stone/ Rubble
Crushing Value/Compressive Strength, Water Absorption & Specific Gravity,
Basic Test of Murrum
Sieve Analysis.
Liquid limit & plastic Limit.
Compaction Test ( Proctor Density ).
C.B.R. Test ( Lab ) With compaction test.
C.B.R. Test ( Field Determination Test) Excluding Transportation.As per IS 2720 Part XXXI
Basic Test of Water
PH Value, Sulphate & Chloride Content.
Basic Test of Wood
Density, Moisture Content.
Basic Test of Flush Door
Knife Test, Adhesion Test, End Immersion Test.
Basic Test of PVC pipes
Weight per running meter,Diameter of pipe & wall thickness of pipe
Basic Test of Steel Bar
(Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
Upto 16 mm (Set of 3 Bars)
Above 16 mm (Set of 3 Bars)
Material Testing Total PART - B
Royalty Charges
For Murum & Rubble
For Natural Sand
Royalty Charges Total PART - C
Furniture Work
Squadro King Bed Cinnamon
Squadro Bedside Table
Bloom Coffee Table Walnut
Squadro 4Dr Wrdrb Cinamon
Prosper Pro Light brown Din Chr
PARTO PLUS 3Str Sofa
PARTO PLUS 2Str Sofa
Edward Corner Table Walnut
Grande Pro DinTbl 4Str Wood
Grande Dark Walnut Din Chr
Cane centre table
Cane chair
Tropical Media Unit Brown
Ortho Plus Mat 78 72 4
Pillow Nice L:425mm W:675mm
White Colour Double Bed Sheets with 2 Pillow cover.
Blanket Woolen Single Dimensions (228.6 x 152.4 cm) Weight 2400 g
Foot Matt 2.5' x 1.5'
Superior Quality Curtains
Furniture Work Total PART - D
Electrical Works
HT METERING KIOSK / TRANSFORMER / RMU / HT / LT PANELS
HT SUBSTATION
Supplying, erecting, testing & commissioning 11 kV, 630A, 21kA/3sec, 3 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 1 no. feeder with 1 VCB. compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA
For Main incomming HT RMU
Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation.
For Main HT Metering & Check Metering
Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 3 way,outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 1 no. feeder with 1 LBS and 2 nos. feeder with 2 VCB. compliant to IEC 62271 -100,200 and 102, as per specification no. SW-HTS/RMU SCADA
For Main HT Metering & Check Metering
Supplying, installation, testing and commissioning 3 phase, 11/0.433 kV, 50 Hz., 1600 kVA, indoor type, vacuum cast coil (VCC) dry type cast resin transformer, Copper wound , Dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temp rise of winding (at Principal Tap) 115°C at ambient temp max 50°C & min -5°C at full load rating, with tapping (with off circuit tap links type tap changer) for off load +5 to - 5% @ 2.5% in +2/-2 steps, HV variation, class of insulation H/H, method of cooling AN, no load loss at rated voltage & frequency (+15% IS Tol) 2.20 KW, full load loss at rated current 9.25 kW, with 98.87 % efficiency at full load & 99.11 % at 1/2 full load, with 75 kV peak full wave lightning impulse withstand voltage with complete enclosure having IP 21 Degree of protection, cable box arrangement at HV side & bus duct at LV side ,with rating & diagram plate, base channel, earthing terminals & WTI scanner with PT-100 sensors, etc. standard accessories complete with test certificate (as per IS:11171 & IS 2026) with necessary permissions of Electrical Inspector as per specification no. SS- TR.
For Main Transformer
LT PANELS
Supplying, erecting, testing & commissioning of Main LT Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Main Incomer Air Circuit Breaker 2500A rated EDO type at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA, (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display,
Outgoing Feeders
ACB 4 Pole 1250 A-2 Nos,
ACB 4 Pole 1000 -1 No.
MCCB 4 Pole-250 A- 6 Nos.
MCCB 4 Pole 100 A-1 No.
MCCB 4 Pole 200 A-1 No.
MCCB 4 Pole 160 A-1 No.
All MCCB rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No.Rotary Handles,RYB indicators,Terminal spreaders,Surge Protection device-1 No.,Panel Control MCB,all busbar electrolyte copper flexible braided bus patti or bar in bus bar chamber/in panel .Refer SLD for details
Supplying, erecting, testing & commissioning of Main LT Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears , and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display,
Bus Coupler-ACB 2500A rated,
Outgoing Feeders
ACB 4 Pole 1250 A-2 Nos,EDO type, rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s)
MCCB 4 Pole-315 A- 2 Nos.
MCCB 4 Pole 250 A-1 No.
MCCB 4 Pole 200 A-1 No.
MCCB 4 Pole 160 A-1 No.
MCB 4 Pole 32 A -2 Nos.
All MCCB rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying and erecting 800 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller min 12 Stage sensing relay Panel complete with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification CAPACITORS,
25KVAr-6 Nos.
50KVAr-9 Nos.
100KVAr-2 Nos.
SPD-1 No.
Supplying, erecting, testing & commissioning of Alternate Meter for Fire fighting system Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ACB 1600 A 4 Pole EDO Type,
static energy Trivector meter 440 V 50 Hz. 20- 100A ISI mark meter AC 3 phase 4 wires LCD/LED display-1 No.
ACB 1000A 4 Pole EDO type-2 Nos.,
MCCB 4 Pole 315 A-1 No,
MCCB 160 A 4 Pole -1 No.,
MCCB 100 A 4 Pole -1 No.
EDO type at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA, (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display,
All MCCB rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Changeover Panel for Fire fighting system of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 1000 A4 Pole-1 No.
Outgoing Feeders
MCCB 4 Pole 1000 A-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCCB -rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Changeover Panel for Critical Load,Fire Lift Emergency Lighting system of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 160 A 4 Pole-1 No.
Outgoing Feeders
MCCB 4 Pole 160 A-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCCB -rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Basement Ventilation system panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 315 A4 Pole-1 No.
Outgoing Feeders
MCCB 4 Pole 315 A-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCCB -rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Lift panel-1 of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 250 A4 Pole-1 No.
Outgoing Feeders
MCB 4 Pole 63 A-5No.
MCB 4 Pole 20 A-5No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCB-with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Refer SLD for details
Supplying, erecting, testing & commissioning of of cubical construction, floor mounted Water & Sump Pumps changeover Panel type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 315 A 4 Pole-1 No.
Outgoing Feeders
MCCB 4 Pole 250 A-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCCB -rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Sewage Treatment Plant changeover Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 100 A 4 Pole-1 No.
Outgoing Feeders
MCCB 4 Pole 100 A-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCCB -rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Laundry changeover panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 100 A 4 Pole-1 No.
Outgoing Feeders
MCCB 4 Pole 100 A-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCCB -rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Critical Load,Fire Lift & Emergency Lighting &Power Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 160 A4 Pole-1 No.
MCCB 4 Pole 160 A-1No.
Outgoing Feeders
MCB 4 Pole 63 A-3No.
MCB 4 Pole 32 A-7No.
MCB 4 Pole 20 A-2No.
MCB 4 Pole 16 A-4No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCB-with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Refer SLD for details Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Common Area Lighting &Power Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 160 A4 Pole-1 No.
MCCB 4 Pole 160 A-1No.
Outgoing Feeders
MCB 4 Pole 100 A-2No.
MCB 4 Pole 63 A-1No.
MCB 4 Pole 32 A-3No.
MCB 4 Pole 25 A-5No.
MCB 4 Pole 16 A-2No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCB-with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Refer SLD for details Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of DG SET Power Panel as per schematic necessary interlocking ,cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ACB 1250 A 4 Pole EDO Type,
static energy Trivector meter 440 V 50 Hz. 20- 100A ISI mark meter AC 3 phase 4 wires LCD/LED display-1 No.
ACB 1250A 4 Pole EDO type-1 Nos.,
ACB 1000 A 4 Pole EDO Type,
ACB 800 A 4 Pole EDO Type,
MCCB 4 Pole 315 A-1 No,
MCCB 160 A 4 Pole -1 No.,
MCCB 63A 4 Pole -1 No.
Air Circuit Breakers-EDO type at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA, (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display,
All MCCB rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of 1st Floor office Power Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
MCCB 4 Pole 315 A-1No.
Outgoing Feeders
MCB 2 Pole 40 A-30No.
Static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display-30Nos
All MCCB rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
MCB-with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Refer SLD for details Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of 1st Floor office area common load Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 160 A4 Pole-1 No.
MCCB 4 Pole 160 A-1No.
Outgoing Feeders
MCB 4 Pole 40 A-3No.
MCB 4 Pole 25 A-1No.
MCB 4 Pole 20 A-3No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCB-with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Office fire lift Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 63 A4 Pole-1 No.
MCB 63A 4 Pole-1No.
Outgoing Feeders
MCB 4 Pole 40 A-1No.
MCB 4 Pole 25 A-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCB-with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Lift panel -2 of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 160 A4 Pole-1 No.
MCCB 160 A 4 Pole-1No.
Outgoing Feeders
MCB 4 Pole 63 A-3No.
MCB 4 Pole 20 A-3No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
All MCCB rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
MCB-with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Basement ventilation panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 315 A4 Pole-1 No.
Outgoing Feeders
MCCB 315 A 4 Pole-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
All MCCB rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Kitchen & Restaurant Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 200 A4 Pole-1 No.
Outgoing Feeders
MCCB 200 A 4 Pole-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
All MCCB rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Water treatment Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 40 A 4 Pole-1 No.
Outgoing Feeders
MCB 32 A 4 Pole-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCB-with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of OWC Panel(Organic Waste collection System) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ATS 40 A 4 Pole-1 No.
Outgoing Feeders
MCB 32 A 4 Pole-1No.
ATS-415V, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 .
MCB-with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Non Critical Load Panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
ACB 800A 4 Pole EDO Type,
Outgoing Feeder
MCCB 4 Pole 250 A-3 No,
MCCB 200 A 4 Pole -1 No.,
MCCB 63A 4 Pole -1 No.
MCCB 32A 4 Pole -2 No.
Air Circuit Breakers-EDO type at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA, (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indication, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display,
All MCCB rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Supplying, erecting, testing & commissioning of Floor panel of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable,control MCB , earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of following switchgears ,
Incomer
MCCB 80A 4 Pole -1No.,
Outgoing Feeder
MCB 2 Pole 40 A-9 No,
All MCCB rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel
MCB-with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Accessories - necessary Metering Current transformers, Load Manager-1 No. Rotary Handles, RYB indicators, Terminal spreaders. Panel Control MCB, all busbar electrolyte copper flexible braided bus Patti or bar in bus bar chamber/in panel. Refer SLD for details
Diesel Generator DG Set
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 750 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 126.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 990 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
For DG Set
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 500 kVA up to 750 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
For DG Set
Sandwich Bus Bar Trunking System
Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 1250A Capacity at 40oC ambient temperature Sandwich type Aluminium Conductor tin plated at joints /Aluminium conductor Silver flashed copper bimetal contact having purity not less than 99.6% with suitable for (3L+ N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54/55 Protection,65KA short circuit rating for 1sec,Insulation Class F (155 C) ,casing made of minimum 1.5mm hot / electro Galvanized /Epoxy powder coated steel sheet enclosure with required shade of paint having Mechanical strength certification up to IK10 overall cross sectional area not more than 0.0225 sq. Mtr., complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories as per site requirement with Horizontal / Vertical G.I. Support at required interval with External Double run 50x5mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specification
For Sandwich Bus Bar
Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 630A Capacity at 40oC ambient temperature Sandwich type Aluminium Conductor tin plated at joints /Aluminium conductor Silver flashed copper bimetal contact having purity not less than 99.6% with suitable for (3L+ N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54/55 Protection,36/40KA short circuit rating for 1sec, Insulation Class F (155 C) , casing made of minimum 1.5mm hot dipped / electro Galvanized /Epoxy
powder coated steel sheet enclosure having Mechanical strength certification up to IK10 with required shade of paint having overall cross sectional area not more than 0.0170 sq. Mtr., complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories with Horizontal / Vertical G.I. Support at required interval with External Double run 50x5mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specification
For Sandwich Bus Bar
Supplying, installing, testing and commissioning air circuit breaker Electrical drawout type, 650V, 1250A rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection) 50 kA (Ics=Icu=Icw for 1s),with standard accessories with ready to close, individual fault trip, alarm and trip indications, mechanical and electrical anti pumping, soft/hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB
For Sandwich Bus Bar End Feed Unit
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
For Sandwich Bus Bar End Feed Unit
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
For DG Set Distribution Panel
Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material,wiring & connections etc.
For Sandwich Bus Bar End Feed Unit
Supplying & erecting LED type indicating pilot lamp with LED colour blue,230 / 250 V on provided box / panel with necessary material, wiring &connections etc.
For Sandwich Bus Bar End Feed Unit
For Sandwich Bus Bar End Feed Unit
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
For Sandwich Bus Bar End Feed Unit
Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for 1250A 3 phase 4 wire 415V, 50 Hz A.C ,65kA short circuit rating for 1 sec Sandwich type Aluminium BBT. with necessary accessories complete confirming to IEC 61439-6 as per specification
For Sandwich Bus Bar End Feed Unit
Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 125A to 200A 3 phase 4 wire 415V, 50Hz AC Supply made with 1.5 mm thick sheet metal enclosure (IP54/55) duly powder coated with provision of MCCB( without MCCB) complete as required confirming to IEC 61439-6 as per specification
For Sandwich Bus Bar
Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
For Sandwich Bus Bar
Supplying, installing & Commissioning Vertical or Horizontal 90 Degree Elbow for Sandwich type Aluminium Compact bus trunking/ rising mains Suitable for 1250A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply,65KA short circuit rating for 1sec Made of minimum 1.5mm Thick Galvanised sheet metal enclosure (IP54/55) duly powder coated with all necessary accessories complete
For Sandwich Bus Bar
Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 2500A Capacity at 40oC ambient temperature Sandwich type Aluminium Conductor tin plated at joints /Aluminium conductor Silver flashed copper bimetal contact having purity not less than 99.6% with suitable for (3L+ N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54/55 Protection,65KA short circuit rating for 1sec,Insulation Class F (155 C) ,casing made of minimum 1.5mm hot / electro Galvanized /Epoxy powder coated steel sheet enclosure with required shade of paint having Mechanical strength certification up to IK10 overall cross sectional area not more than 0.0225 sq. Mtr., complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories as per site requirement with Horizontal / Vertical G.I. Support at required interval with External Double run 50x5mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specification
For Transformer to Main LT Panel
Supplying, installing & Commissioning Vertical or Horizontal 90 Degree Elbow for Sandwich type Aluminium Compact bus trunking/ rising mains Suitable for 2500A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply,65KA short circuit rating for 1sec Made of minimum 1.5mm Thick Galvanised sheet metal enclosure (IP54/55) duly powder coated with all necessary accessories complete
For Transformer to Main LT Panel
Supplying, installing & Commissioning end feed box comlete with flexible joints Sandwich type Aluminium Compact bus trunking/ rising mains Suitable for 2500A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply,65KA short circuit rating for 1sec Made of minimum 1.5mm Thick Galvanised sheet metal enclosure (IP54/55) duly powder coated with all necessary accessories complete
For Transformer Main LT Connection
Distribution Board
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
For Rest Room Distribution Board
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
For Rest Room Distribution Board
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
For Rest Room Distribution Board
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
For Rest Room Distribution Board
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
For Rest Room Distribution Board
Supplying and erecting single pole and neutral distribution board (SPNDB),with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB
For Rest Room Distribution Board
Supplying & erecting triple pole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
For Staircase, Shafts DB
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
For Staircase, Shafts DB
Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
For Staircase, Shafts DB
Supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “ON” and switching “OFF” street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230 V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box.
For Staircase DB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
For Lift in Machine Room
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
For Lift in Machine Room
Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
For Lift in Machine Room
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
For Typical Lobby, Refuge Floor, Service Floor, Terrace, External, Basement Lighting & ELV DBs
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
For Typical Lobby, Refuge Floor, Service Floor, Terrace, External, Basement Lighting & ELV DBs
Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 4 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
For VIP Lounge / Kitchen
POINT WIRING
Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/SW.
For Rest Room Light Point
Secondary point wiring for additional light/ bell point, concealed type in
min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade
copper wires with required accessories as per specification No: WG-PW/CW
For Typical Passage Secondary Light Point
Supplying and erecting modular type buzzer 220 / 250V, duly erected on
provided plate and box with wiring connections complete.
For Rest Room Buzzer
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
For Rest Room Buzzer
Supplying and erecting PVC Surface modular double mounting plate 2
module complete duly erected.
For Rest Room Buzzer
Point wiring for ceiling fan in 20 mm FRLS grade HMS PVC conduit with 1.5
sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and
required accessories as per specification No: WG-PW/SW
For Rest Room Ceiling Fan
Supplying and erecting modular type (two module) electronic step regulator
for fan, duly erected on provided plate and box with wiring connections complete
For Rest Room Ceiling Fan
Point wiring for independent plug in 20 mm FRLS grade HMS PVC conduit
with 1.5 sq.mm (2+1E ) FRLSH grade copper wire, modular type switch,
earthing and required accessories as per specification No: WG-PW/SW
For Rest Room Plug Point
Supplying and erecting modular type switch 16 / 20 A with indicator, duly
erected on provided plate and box with wiring connections complete.
For Rest Room AC Point
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety
shutter, duly erected on provided plate and box with wiring connections
complete.
For Rest Room AC Point
Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC
insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any
other places as per specification No: WG-MA/BW
For Rest Room AC Point
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with
necessary accessories in wall/floor with chiselling appropriately as per
specification No: WG-MA/CC.
For Rest Room AC Point
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
For Rest Room AC Point
Supplying and erecting PVC Surface modular double mounting plate 3 module complete duly erected.
For Rest Room AC Point
Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
For Rest Room Geyser Point
For Rest Room Geyser Point
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
For Rest Room Geyser Point
Supplying and erecting PVC Surface modular double mounting plate 1
module complete duly erected.
For Rest Room Geyser Point
For Rest Room Geyser Point
Supplying and erecting modular type 32A, DP key tag switch with key tag,
duly erected on provided plate and box with wiring connections complete.
For Rest Room Key Tag Switch
For Rest Room Key Tag Switch
Supplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulated
wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
For Rest Room Key Tag Switch
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with
necessary accessories in wall/floor with chiselling appropriately as per
specification No: WG-MA/CC
For Rest Room Key Tag Switch
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
For Rest Room TV Point
Supplying and erecting modular type computer Jack RJ45 with safety shutter,
duly erected on provided plate and box with wiring connections complete.
For Rest Room Internet Point /TEL POINT -UC SYSTEM REDUNDANCY
LIGHT / FAN / REST ROOM LOCK / WATER HEATER / REFRIGERATOR
LIGHT FIXTURES
Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting
arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
For Rest Room Light Fixture
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
For Parking Area Light Fixture
Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting
arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
For Rest Room Toilet Light Fixture
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
For Rest Room Toilet Mirror Light Fixture
LIFT SHAFT Light
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
For Lift Shaft
Supplying and erecting decorative Table lamp with Min 20W LED warm white lamp decorative white fabric with complete accessories
for Suite Rooms
Supplying & erecting UV Fly killer/ bug catcher Light Fitting having 2 x 20W UV Tube Lights to cover min. area of 500 sq.ft with powdered coated M.S./ steel body suitable to work on 230V, AC Supply having top mounting arrangement with SS chain complete and 3 core 1 mtr. flexible wire with 1 year warranty.
For Restaurant
Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification No FG-ODF/FLS2.
External road lighting
Supplying & erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL
CSR No.2.5.5 page 31
Supplying & erecting 18W, 230V integral type LED Lamp suitable for B-22 / E
For External lighting Main Gate Post top
Supplying and erecting Concealed type foot/step light Max. 5W having IP67. IK10 rated Pressure die cast housing having system lumens output of Min. 500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD0.95, operating range of 230-270V, surge protection of 2.5 kV, Life class of 25,000 Hrs. at L70B50, including driver by making necessary arrangement/recess in wall to make it flush with surface with 2 Year warranty.
For External Ramp steps
Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.
For External Ramp steps
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
For External Light Bracket
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Street Light Pole
Making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole)
Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty.
FOR ROMS & SUITE ROOMS
Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty.
FOR ENTRANCE LOBBY COVE LIGHT
DOOR ACCESS CONTROL SYSTEM
Hotel lock with ANSI Motorise Model:B005-S SILVER FINISH/Equivalent
For Rest Room ,Suite rooms Main Door Access control system Lock
RF Card
For Rest Room Main Door Access control system Lock
Encoder for Card Programming
For Rest Room Main Door Access control system Lock
Software for Card Programming /Training
For Rest Room Main Door Access control system Lock
Ceiling Fan/Exhaust Fan
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
For Rest Room Ceiling Fan
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
For Common Toilet ,Substation Room Exhaust Fan
Water Heater
Supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof ABS plastic body, high grade SS inner tank & 3kW heating element with corrosion & hard water protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, function valve) complete with 6.5 bar pressure withstanding capacity 230/250V, 50Hz, A.C. supply with inlet and outlet, with 3 core PVC flexible copper wire leads duly tested and marking sr. no. and date of erection complete.
For Rest Room Geyser
Aviation Light
Supplying & erecting Aviation obstruction light consisting of yellow painted diecast
aluminium alloy housing with Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete.
For Aviation Light
Mini Refrigerator
Supplying single door refrigerator domestic type of 50 litres storage
capacity, minimum 5 Star inverter type, stabilizer free operation suitable for
operation on 100V/300 V, 50 Hz with automatic temperature control, shall be
marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection complete.
Suite Rooms
Supplying, erecting ,Testing & commissioning Mini water dispenser HOT,COLD,NORMAL OUTLET WITH MIN 15 LTR CAPACITY With 5 year of warrenty
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with partially stainless steel body As per specification no. APWCR/ WC
For Restaurant/Service room
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.
For Water Cooler
EARTHING
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
For Earthing
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP.
For Earthing
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
For Earthing
Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete.
For Earthing
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/conduit with screws complete.
For Earthing
LT Cabling
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
For Rest Room Main Incoming Cable from Shaft to DB
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
For Lifts, External lighting, Staircase & Shaft Lighting
For Offices Meter room to DB
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
For Lifts
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
For Lifts
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Office Lift
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
For Kitchen, VIP Lounge, puzzle , stack parking
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
For Common area panel
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
For RO
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
For LIFT PANEL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
For MAIN PANEL, APFC, FF ETC.
CABLE TRAY
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories.
For Cable
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories.
For Cable
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
For Cable
Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm width & 20 mm height complete with necessary hardware.
For Cable
ROOFTOP SOLAR
Supplying, installing, testing and commissioning of 100 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 300 Nos.) and Solar ON-GRID Inverter of similar capacity (THDwith
interconnecting wires / cables up to solar ON GRID inverter, proper base plate,
canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB ,
MCB etc. wiring up to solar Inverter in casing and capping, display board, sign
board, two distinct earthing, lightning arrester, liaisoning charges, remote
monitoring system with maintaining card / chip for 5 years including net charges
for RMS System, complete up to net meter Installation and export to the grid with
5 year ON-SITE warranty and fully comprehensive maintenance contract
as per Specification no. ESD-RT-ONG.
Roof Top ON GRID SOLAR on Terrace
For all Floor Pantry
Supplying, installation & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD
FOAR ALL PANELS
Supplying and erecting AC three phase HT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz, with backlit LCD display, optical port & RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
For Solar Net Metering
UPS FOR COMMAND CENTER & EMERGENCY LIGHTING
Supplying, erecting, testing and commissioning of 20kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input and 3 phase output complete with all protections as per specification no. AP-UPS
For Command Center
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
For Command Center
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 3 phase output complete with all protections as per specification no. AP-UPS
For Emergency Lighting
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
For Emergency Lighting
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
For Battery Rack Command center & Em.Lighting UPS Battery sets
PUMPS & ACCESSORIES
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 57 to 22 m and discharge from 120 to 900 litres. . per minute & pipe of Suction 75 mm/Delivery 65 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
FOR SUMP Basement
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
for Lift Shafts Dewatering
Supplying and erecting minimum Three & above star rated 3 phase, 415 V, 50 Hz, submersible pump set of 7.5 KW/10HP suitable for erection on open well, pump having delivery head from 72 to 28 m and discharge from 120 to 840 litres. per minute & pipe of Suction 65 mm/Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
For Domestic & Flushing Pumps
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
For Pumps
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 13-21 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
For Domestic & Flushing Pumps
Supplying & erecting Water level controller 230/415 V, A.C. , Two way under ground tank operation only.
For Pumps DOM/FLUSHING
Supplying & erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos)
For Pumps DOM/FLUSHING
Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
For Pumps
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Emergency Lighting DB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
FOR UPS INCOMER & OUTGOING Emergency Lighting
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
FOR UPS INCOMER & OUTGOING Emergency Lighting
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Emergency Lighting DB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Emergency Lighting DB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
For UPS Emergency Lighting
AIR TERMINATION SYSTEM
Supply,erecting,testing & commissioning of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination system . Cross sectional area of conductor should be 50 mm².
Test Parameter:
a.Lightning impulse current of 100kA for 10/350 µs.
b.Electrical resistivity - 0.036 µΩm, Tensile strength - 120 to 240 MPa or N/mm²; Salt spray - No Sign of Corrosion.
Tested as per IEC 62561-2.
Supply,erecting of UV resistance Nylon/PU Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor
Supply,erecting of UV resistance Nylon/PU roof conductor holder for flat roof with concrete block for fixing 8 mm dia Aluminium alloy solid round conductor in the terrace flat surface at every 1 mtr.
Supply,erecting, of Stainless steel Cross Connector for 8 mm dia Aluminium alloy round conductor & 10 mm Copper bonded conductor at cross junction.
Test Parameter
Salt Spray Test ( IEC 62561-1) - No sign of Corrosion
Supply,erecting of Expansion Piece with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations.Expansion piece should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor .
Test Parameter:
Electrical Resistivity Test-0.036 µΩm.
Salt Spray Test - No Sign of Corrosion.
Tested as per IEC 62561-1.
Supply,erecting,testing & commissioning of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Tested for Electrical, Mechanical and chemical as per IEC 62561.
Supply,erecting,testing & commissioning of air termination rod of 3 mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with stainless steel wall clamp and fixing accessories .
Test Parameter:
Mechanical Load Test for individual aluminium alloy rods - 120 to 280 N/mm²
Salt Spray Test-No sign of corrosion
Tested as per IEC 62561-1&2
Supply,erecting,testing & commissioning of air termination rod of 2mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with necessary supporting base and fixing accessories .
Test Parameter:
Mechanical Load Test for individual aluminium alloy rods - 120 to 280 N/mm²
Salt Spray Test-No sign of corrosion
Tested as per IEC 62561-1&2
Supply,erecting,testing & commissioning of Vertical air terminal with corner protecting measures along with suitable mounting arrangements to protect the corners and edges of terrace area to avoid direct strike & side flashes.
Supply,erecting,testing & commissioning of Stainless steel Folded clamp to connect metal parts with the 8 mm Aluminium conductor to meet the requirement of IS/IEC - 62305-3.
DOWN CONDUCTOR SYSTEM
Supply,erecting,testing & commissioning of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination system . Cross sectional area of conductor should be 50 mm².
Test Parameter:
a.Lightning impulse current of 100kA for 10/350 µs.
b.Electrical resistivity - 0.036 µΩm, Tensile strength - 120 to 240 MPa or N/mm²; Salt spray - No Sign of Corrosion.
Tested as per IEC 62561-2.
Supply,erecting of UV resistance Nylon/PU Conductor Holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor .
Supply,erecting of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Tested for Electrical, Mechanical and chemical as per IEC 62561.
Supply,erecting,testing & commissioning of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.
Supply,erecting,testing & commissioning of Stainless Steel Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor.
Test Parameter:
Salt Spray Test for test joint plate -No sign of Corrosion
Tested as per IEC 62561-1
EARTHING SYSTEM
Supply,erecting,testing & commissioning of Rust resistant non corrosive 10 mm dia Copper bonded round conductor used for Earth termination inside the concrete and soil.
Test parameter:
Short circuit current test for copper bonded conductor: Test 6 kA ratings, as per cross sectional area for 1 sec(IS3043/IEEE80); Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. Tensile Test 290 to 510 N/mm². Adhesion no peel or crack & Bend test no seperation of Cu, Cu Coating thickness min. 70µm.
Tested as per IEC 62561-2.
Supply,erecting,testing of Stainless steel Conductor Holder for fixing the 10 mm dia round conductor on the side wall .
Test Parameter:
Salt Spray Test - No Sign of Corrosion
Tested as per IEC 62561-1
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
for LA
HVAC SYSTEM BOQ
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC
For all Rooms,Suite Rooms
Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 2.1TR (800 cfm) to 2.4TR (960 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete.
For restaurant,Meeting Room,& VIP LAUNGE
Supplying, erecting, testing and commissioning of 16HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather
For ground floor Area
Supplying, erecting, testing and commissioning of 14HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
For VIP Launge 11 th Floor
Supplying, erecting, testing and commissioning of 7HP to 8HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
For Meeting Rooms 11 th Floor
Supplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
For Restaurant 2nd Floor
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete.
For Restaurant,VIP launge,Meeting Rooms
supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
For Restaurant,VIP launge,Meeting Rooms
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
For all Rooms,Suite Rooms
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.
For all Rooms,Suite Rooms
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC
For all Rooms,Suite Rooms,Meeting rooms,VIP launge
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
For all Rooms,Suite Rooms,Meeting rooms,VIP launge
Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 300 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.
For all Rooms,Suite Rooms,Toilets
Supply, Installation, Testing and Commissioning DIRECT DRIVE VANE AXIAL FAN of 30000CFM rating Double flanged casing is produced in mild steel or galvanized steel. Impeller is made of Aluminum. Finish Zinc rich primer and polyester powder coating or galvanized finishing are available for all mild steel parts. Motors Totally enclosed Class 'F'/ 'H' motors with a min. IP54 protection are fitted as standard. Motors up to 2.2kW are supplied with DOL starting, motors 3.0kW and above are with star/delta starting. Flow Direction Uni-directional, reversible fan is available upon request. Silencer Outer casing made of galvanized steel sheet and inner casing made of galvanized steel perforated sheet. Inlet bell-mouth provided for smooth airflow. . Glass fiber as absorption filler material to achieve excellent acoustic performance. Each model is available with 2D silencer as standard. Non- standard length to meet special performance requirement can be supplied upon
FOR BASEMENT VENTILATION
Supply, Installation, Testing and Commissioning of INDUCED JET FAN of 8000 CFM rating Double flanged casing is in mild steel or galvanized steel. Impeller made of Aluminum. Finish Zinc rich primer and polyester powder coating or galvanized finishing for all mild steel parts. Totally enclosed Class 'F'/ 'H' motors with a min. IP54 protection are fitted as standard.. Flow Direction Uni-directional, reversible fan . Silencer Outer casing of galvanized steel sheet and inner casing of galvanized steel perforated sheet. Inlet bell-mouth provided for smooth airflow. . Glass fiber as absorption filler material to achieve excellent acoustic performance with 2D silencer as standard.
FOR BASEMENT VENTILATION
Supply, Installation, Testing & Commissioning of FACTORY / SITE FABRICATED rectangular sheet metal ducts, as per specifications detailed in tender, made of Class VIII GP sheet as per SMACNA Standard for medium pressure air flow with MS angle / TDF flanges, supports, anchor fasteners, food grade gaskets and RTV sealant in accordance with the approved shop drawings. it is mandotary to use factory fabricated ducts for minimum 90% of the ducting system. Use of Site fabricated ducts should be restricted to only 'to suit' pieces.Cold rolled sheets continuous galvanized sheet steel with zinc coating as per class VIII confirming to IS:277-1962 (revised)(where ever specified) of LFQ (Lock Forming Quality) grade. Galvanizing shall be of 120gms/sq. m (Total coating on both sides) The fabrication of the ducting system for air-conditioning & Ventilation shall confirm to SMACNA-1995 standards ("HVAC Duct Construction Standards - Metal and Flexible - Second Edition - 1995"-SMACNA).Ducts of following Guage/thickness with Flanges, G.I. Sheet Metal Duct. 22 G(0.63mm)
0.63 MM (24G) - Rectangular Duct
0.80 MM (22G) - Rectangular Duct
All rest room Toilet ,Commln toilest,basement ventilation,MEETING ROOM
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
For AC UNITS ODU -IDU Connection
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 32 mm for solar water heater/AC system.
drain pipe insulation hvac
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.
HVAC units Insulation
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
For Support HVAC system
Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.
Exhaust grill
Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system.
Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC2017.
FOR VRV
Providing and applying of acoustic insulation for air ducts with 25mm thick, 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete.
FOR VRV
Supplying and erecting PVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Control Cabling VRV
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
For Rest Room ,D
Providing vaccumising the airconditioner system and charging with refrigerant R32 for AC unit
FOR VRF & SPLIT AC
Unified communication & Networking System
Providing,erecting,Testing & commissioning Unified comminication system With 75 concurrent resources and upto 500 user licenses and Video conference bridge built in(4 video conference rooms with upto 40 video participants in 1080P). These partipants could come in through Video Ip Phone or Wave apps on Android.IOS or Mac or Windows
Unified communication system for Voice data
Auto negotiation 10/100 dual ports, POE Class2, 6 programmable keys for Hospitality services
For Rest Room,Suite rooms,Security Telephone
NETWORKING SYSTEM
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
For Floor Networking
Supplying and fixing 24 U floor mount rack (Dimension-DxWxH – 800x600x1265 mm) as per specification No. WG-NAS/RAK
For Floor Networking
Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK
For Floor Networking
Supplying and installing armoured single mode optical fibre cable with 6 fiber, core dia 50/125μm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete.
For Floor Networking
Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC
For Floor Networking
Supplying and installing cat-6 cable suitable for networking as per specification
no. WG-COC/NC
For Rest Room Internet Point & telephone point
Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-
6 as per specification No. WG-TW
For Rest Room TV Point
Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
For Rest Room ,DATA,TEL,TV Point
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
For Rest Room ,DATA,TEL,TV Point
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification
For Rest Room ,DATA,TEL,TV Point
CCTV SURVEILLANCE SYSTEM
SITC of 2MP IR Bullet Camera (2.8mm Lens)-1 / 2.8” SONY - CMOS (STARVIS Series)
2MP, 0Lux with IR LED ON 2MP, 0Lux with IR LED ON Horizontal Field of View: 107 degrees & IR Range of up to 30 meters Video Analytics: Trip Wire, Intrusion Detection and Motion Detection H.265/H.264/MJPEG Video Compression PoE Support, NAS Storage, Quad Stream Support True WDR, 3D Noise Reduction, Adaptive Streaming, Smart Streaming and ROI, SNR > 70 dB IP66, BIS, CE, FCC and RoHS
All floor Surveillance
SITC of 2MP IR Bullet Camera (2.8mm Lens)1 / 2.8” SONY - CMOS (STARVIS Series) 2MP, 0Lux with IR LED ON Horizontal Field of View: 107 degrees & IR Range of up to 30 meters Video Analytics: Trip Wire, Intrusion Detection and Motion Detection H.265/H.264 /MJPEG Video Compression PoE Support, NAS Storage, Quad Stream Support True WDR, 3D Noise Reduction, Adaptive Streaming, Smart Streaming and ROI, SNR > 70 dB IP66, BIS, CE, FCC and RoHS
Ground floor External Area Surveillance
SITC of 32 Channel NVR with 4K Support and 4 HDD Slots32 IP Channel Inputs; HDMI, 1/1 Audio I/O and 2/1 Alarm I/O 12MP, 8MP, 5MP, 4MP, 3MP, 2MP, 720p, D1 & CIF Recording Resolution 5x 4K, 16x 8MP, 24x 1080p, 54x 720p, 64x D1 Local Decoding 4 SATA HDD Support (10TB Capacity per Slot, Hard Disk Not Included) Save Storage Space with Adaptive Recording & Camera-wise Recording Retention SMS & Email Notification, Video Pop-up, Alarms and Calling from Mobile Application 512Mbps Throughput - 256 Uplink, 256 Downlink Cascading: Manage Multiple Matrix NVRs ONVIF and Major Camera Brands Support
All floor Surveillance
SITC of 64 Channel NVR with 4K Support and 8 HDD Slots 64 IP Channel Inputs; HDMI, 1/1 Audio I/O and 2/1 Alarm I/O 12MP, 8MP, 5MP, 4MP, 3MP, 2MP, 720p, D1 & CIF Recording Resolution 4x 4K, 16x 8MP, 24x 1080p, 54x 720p, 64x D1 Local Decoding 8 SATA HDD Support (10TB Capacity per Slot, Hard Disk Not Included) Save Storage Space with Adaptive Recording & Camera-wise Recording Retention SMS & Email Notification, Video Pop-up, Alarms and Calling from Mobile Application 512Mbps Throughput - 256 Uplink, 256 Downlink Cascading: Manage Multiple Matrix NVRs ONVIF and Major Camera Brands Support
All floor Surveillance
Supplying, installation, testing & commissioning of 10TB surveillance Hard Disk -he 10TB Purple 5400 rpm SATA III 3.5" Internal Surveillance Hard Drive designed to withstand the stresses placed on it in a 24/7, always-on, high-definition surveillance system with 8+ drive bays. With support for up to 64 high-definition surveillance cameras, this 10TB hard drive can hold a large amount of data and gives you the ability to easily upgrade and expand your security system. Furthermore, AllFrame 4K technology helps improve video capturing and reduces errors, pixelation, and video interruptions that could happen in a video recorder system.A SATA III 6 Gb/s interface, sustained data transfer speeds of up to 210 MB/s, and a 256MB cache all help to ensure uninterrupted data transfers. Furthermore, the drive's 300,000 load/unload cycles, annualized workload rating of 360TB per year, MTBF rating of 1 million hours, and <1 in 1015 non-recoverable read errors per bit read also help to ensure a strong operational life.Storage calculation Min 90 Days
All floor Surveillance
Supplying, fixing, and configuring 24 ports + 4 (SFP+) port, Managed Layer 2, POE Switch of , 370W, 6KV surge protection on ethernet port and console port for management erected in provided rack complete.
CCTV SYSTEM Switch
Supplying, fixing, and configuring 10G Base -SR (SFP+) simplex MM transceiver erected in provided rack complete.
CCTV SYSTEM Switch
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
For Switch Patch
Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC
All floor camera
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
CCTV System Termination
Supplying and fixing 24 U floor mount rack (Dimension-DxWxH – 800x600x1265 mm) as per specification No. WG-NAS/RAK
CCTV System Termination
Cabling and Conduiting
Supplying and installing cat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC
CCTV System Termination
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
CCTV System Termination
SITC of Fire Alarm Control Panel (FACP) with Voice Command Centre & Fire Fighting Telephone
SITC of Active Repeater Panel
SITC of Multi Sensor (Photoelectric Optical Smoke + Heat) detector with base
SITC of Smoke Sensor (Photoelectric Optical Smoke) detector with base
SITC of Heat Detector with base
SITC of Indoor Application Manual Call Points
SITC of Intelligent Addressable Double Action Indoor Application Manual Pull Stations / Manual Call Points suitable for wall/column mounting. MCP shall have red coloured housing with molded, raised-letter operating instructions of contrast colour. The MCP shall latch mechanically upon operation and shall remain so until manually reset with its key by an authorized operator. The MCP shall have operating temperature range from 0°C to 50°C and humidity tolerance range up to 93% RH, Non-Condensing.UL & FM Approved
SITC of Addressable Notification Appliances - Sounders with Strobe
SITC of Monitor Module
SITC of Intelligent Addressable, Supervised Monitor Module monitoring Potential-free, Normally Open Dry Contact input. The Monitor Module shall have operating temperature range from 0°C to 70°C and a humidity tolerance of up to 93% RH, Non-Condensing.UL & FM Approved
SITC of Control Relay Modules
SITC of Intelligent Addressable Potential-free, Form-C, SPDT contact based control module to trigger 3rd party utilities like AHU shut-off, Pressurization fan activation, Special notification activation etc. The contact shall be rated for 2A@24Vdc (Resistive) & 1A@24Vdc (Inductive). The control module shall have operating temperature range from 0°C to 49°C and a humidity tolerance of up to 93% RH, Non-Condensing.UL & FM Approved
SITC of Short Circuit Isolator
SITC of Intelligent Addressable, Supervised Short-Circuit Isolator module or base. The Isolator Monitor Module shall have operating temperature range from 0°C to 49°C and a humidity tolerance of up to 90% RH, Non-Condensing.UL & FM Approved
SITC of Ceiling Mount Speakers
SITC of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling Mount, White Speakers. The speakers shall be of same make as that of the Control Panel & Amplifiers and shall have a Rugged, high impact, flame retardant thermoplastic housings. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms.UL & FM Approved
SITC of Wall Mount Speakers
SITC of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Wall Mount, Red speakers with white "FIRE" lettering. The speakers shall be of same make as that of the Control Panel & Amplifiers and shall have a Rugged, high impact, flame retardant thermoplastic housings.. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms.UL & FM Approved
SITC of Fire Fighter Telephone Station
SITC of Fire Fighter Telephone Station complete Fire Fighter's Handset and Accessories enclosed in a Red Enclosure. UL & FM Approved
SITC of Addressable Fire Telephone Jack .UL & FM Approved
Cables
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
FIRE FIGHTING SYSTEM
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 140 to 120 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 93kW or of suitable kW capacity for manual/automatic operation and consisting of following
Main Fire pump Basement
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 140 to 110 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 15 kW or of suitable kW capacity for manual/automatic operation and consisting of following
Main Fire Jocky pump Basement
Supplying, installing, testing and commissioning with perfect
aligning, proper levelling of booster pump of 900 LPM at 40 m
Head, 12.5 HP (10 KW), 3 phase, 415 volt, 50Hz or of suitable HP
with suitable stages as per specification no. FF-MFP/BP
Supplying and erecting G.I. pipe above ground of „C‟ class ERW
of size 25 mm dia with necessary fittings complete as per
specification no. FF-PP
For Fire fighting sprinkler lines
Supplying and erecting G.I. pipe above ground of „C‟ class ERW
of size 50 mm dia with necessary fittings complete as per
specification no. FF-PP
For Fire fighting sprinkler lines
Supplying and erecting G.I. pipe above ground of „C‟ class ERW
of size 65 mm dia with necessary fittings complete as per
specification no. FF-PP
For Fire fighting sprinkler lines
Supplying and erecting G.I. pipe above ground of „C‟ class ERW
of size 75/80 mm dia with necessary fittings complete as per
specification no. FF-PP
For Fire fighting sprinkler lines
Supplying and erecting G.I. pipe above ground of „C‟ class ERW
of size 100 mm dia with necessary fittings complete as per
specification no. FF-PP
For Fire fighting sprinkler lines
Supplying and erecting G.I. pipe above ground of „C‟ class ERW
of size 150 mm dia with necessary fittings complete as per
specification no. FF-PP
Riser
Supplying and erecting G.I. pipe above ground of „C‟ class ERW
of size 200 mm dia with necessary fittings complete as per
specification no. FF-PP
Riser
Providing coating of bitumen paint & 4mm thick wrapping for
underground 100 mm ring main of fire fighting system.
Providing coating of bitumen paint & 4mm thick wrapping for
underground 150 mm ring main of fire fighting system.
Gr Main Ring
Supplying and erecting 100 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying and erecting 100 mm dia end line strainer for positive
suction complete as per specification no. FF-VL/ELS
Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying & erecting cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 65 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 200 mm dia. complete as per specification no. FF-VL/BFV
Supplying and erecting cast iron double flange ball type NRV of size 100 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange ball type NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange ball type NRV of size 200 mm dia complete as per specification no. FF-VL/NRV
Supplying & erecting gun metal gate valve of size 25 mm dia
complete as per specification no. FF-VL/GV
Supplying & erecting gun metal gate valve of size 50 mm dia
complete as per specification no. FF-VL/GV
Supplying and erecting stainless steel single outlet hydrant
valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and erecting stainless steel double outlet hydrant
valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying fire fighting controlled percolation (C.P.) Hose pipe,
63mm dia, 15m in length, fitted with necessary accessories
complete as per specification no. FF-FFA/CPH
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and installing wall mounting swinging Hose reel drum
fitted with 19 mm dia. 30m long high pressure polypropylene
(Polyhose) fitted with necessary accessories complete as per
specification no. FF-FFA/HV
Supplying & erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
Supplying & erecting gun metal chrome plated nozzle, 19 mm dia complete as per specification no. FF-FFA/NZ
Supplying and erecting fire brigade header of 150 mm dia, for
supplying water in fire tank complete as per specification no. FFFA/ FBC
Supplying and erecting fire brigade header (Siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC
Supplying and installing air vessel of 300 mm dia 1.5m in height
M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock,
with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/ PG
Supplying and installing pressure switch with 12/15 mm dia
isolation valve, G.I. nipple, elbow, etc complete as per
specification no. FF-FFA/PS
Supplying and erecting one no. brass orifice plate having 6 mm.
thickness, 140 mm outer dia and required/proper diameter of
inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting one no. brass orifice plate having 6 mm.
thickness, 160 mm outer dia and required/proper diameter of
inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing single
hydrant valve (size 400 x 400 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and erecting M.S./CRCA cabinet for housing Fire
Brigade / SIEMESE connections (size 1250 x 400 x 300 mm.)
made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking
arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and erecting M.S./CRCA cabinet for housing Floor
Hydrant valve, hose pipe, hose reel and branch pipe (size
1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron
25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying, erecting, testing and commissioning of 15 mm (½") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR
Supplying, erecting, testing and commissioning vane type water
flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 75/80 mm dia having following features 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4) Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes
Supplying and erecting fire resistant mortar (20 kg) with fire
resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings with all kinds of cables, pipes and cable support system in steel and aluminium and plastic profiles ( Except hollow core conductors). The residual openings shall be closed with
filler, as per specification no. FF-FRM
Supplying and erecting ABC powder type fire extinguisher as per
IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection
on wall.
Supplying and erecting D.C.P. type fire extinguisher 9 kg
capacity cartridge type with Gun Metal cap 150 gram CO2 gas
cartridge, powder and brackets conforming to IS 2171-1985 and
complete erected with necessary clamps made from 50x6 mm M.S.
flat with nuts & bolts grouted in wall complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS :
2546 made out of 24 gauge G.I. sheet with extra handle at bottom
duly painted white inside and red outside with FIRE Mark, on
provided stand/ wall hook complete.
Providing Floor mounting stand for keeping 4 Nos. of FIRE
buckets 1500mm in length, 900mm in height frame made out of
30x30x4 mm angle iron with cross supports for legs, welded with 4
hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying, erecting & terminating XLPE armoured cable 3½ core
95 sq. mm. aluminium conductor with continuous 8.35 sq. mm.
(10 SWG) G.I. earth wire complete erected with glands & lugs, on
wall/ trusses/pole or laid in provided trench/ pipe as per
specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3 core 25
sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12
SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supply, Installation, Testing & Commisioning of standard response standard coverage sprinkler head with quartz bulb and set to operate at 68°C. wherever required and all accessories, supports and painting etc. (Side wall Type)
Providing, fixing, testing and commissioning of Installation Control Valve with turbine type automatic Alarm Gong to be connected with control valve, drain & test valve and all other necessary components as per manufacturer's specifications complete as required.
Supplying, erecting, testing & commissioning of fire pump control panel (FCP)
of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications
the capacity of electric motor driven pump are as follows
a. Main fire pump(MFP) having capacity of 93kW 1no (1 working)
b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode)
comprises of the following features & switchgears:
1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.
2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc.
3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable
rating.
Supplying, erecting, testing & commissioning of fire pump control panel (FCP)
of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications
the capacity of electric motor driven pump are as follows
a. booster pump 7.5 kw capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode)
comprises of the following features & switchgears:
1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.
2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc.
3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable
rating.
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Manual Call Point (MCP)- 9" x 9"
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Fire Exit -12"x 6"
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Assembly point -38"x38"
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Fire Extinguisher-9" x 9"
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Fire Pump Room-38"x38"
Supply & Instalation of Self Glowing nonreflective Type Sinages, made of 1.2 mm thick Rigid Plastic for Indoor / Outdoor Aplication with Green Background & white Text in satin finish. Text should be in portrait oreintation & Fixing of Sinages should be Permanent self adhesive type manifesting following Text as given below. Directional Arrow-12"x 6"
Supplying and erecting GI strip of required size used for earthing onwall and/or any other purpose with necessary GI clamps fixed onwall painted with bituminous paint in an approved manner with jointsrequired. As per specification no EA-EP.
Supplying, installing, testing and commissioning FR, XLPE
armoured cable 2 core 1.5 sq.mm. copper conductor complete
erected on wall/ ceiling complete as per specification no. CBLT/
AV SYSTEM FOR MEETING ROOMS & ROOMS
Supplying, erecting, testing and commissioning 65''LED smart TV Resolution : Crystal 4K UHD (3840 x 2160)
resolution | Refresh Rate : 60 Hertz
Connectivity: 3 HDMI ports to connect set top
box, Blu-ray speakers or a gaming console | 1
USB ports to connect hard drives or other USB
devices
Display: Ultra HD (4k) LED Panel | One Billion
Colors | Air Slim Design | Supports HDR 10+ |
PurColor | Mega Contarst | UHD Dimming | Auto
Game Mode
Sound: 20 Watts Output | Powerful Speakers
with Dolby Digital Plus | Q Symphony
Smart TV Features : Prime Video, Hotstar,
Netflix, Zee5 and more | Tap View | PC Mode |
Universal Guide | Web Browser | Screen
Mirroring
Warranty Information: 1 Year warranty provided by the vendor
For Meeting Room & VIP Lounge ,Receiption Area
Supplying, erecting, testing and commissioning 32'' SMART LED TV, Supported Apps: Netflix|Disney+Hotstar|Youtube
Operating System: Tizen
Resolution: HD Ready 1366 x 768 Pixels
Sound Output: 20 W
Refresh Rate: 60 Hz
FOR ROOMS
Supplying, erecting, TV Wall mounted Bracket Black metalic 2 mm thickness having sufficient load capacity of 32 '' to 85'' TV Size.with Powder coated finish with Necessary Anchor fastner for the fixing.
FOR ROOMS/Suite rooms/Meeting Rooms/VIP Lounge/Receiption
Supplying, erecting TV Set top box stand Metalic/SS finish 2mm thickness with necessary fixing accessories complete.
FOR ROOMS/Suite rooms/Meeting Rooms/VIP Lounge/Receiption
Supplying and erecting 25m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
for Meeting rooms
Supplying, erecting, testing and commissioning Hydraulic TYPE Cable Cubby Popup Box with HDMI Connector, Audio Connector LAN Wire & Power Ports & USB Port,having 10 Module, Silver Color or as per EIC
FOR Meeting Rooms/VIP Lounge
Supplying, erecting, testing and commissioning VGA cable( Computer ), A type 15pin male-A type 15PIN male,High quality vga cable 15 MTR
FOR Meeting Rooms
Supplying, erecting, testing and commissioning RCA PATCH CORD MALE-20 MTR FOR PROJECTOR/TV SCREEN
FOR Meeting Rooms
COMPLETE DESIGN,SUPPLY,ERECTION ,TESTING & COMMISSIONING OF CAPSULE LIFT,PASSENGER ,FIRE LIFT
COMPLETE DESIGN ,SUPPLY,ERECTION ,TESTING & COMMISSIONING OF CAPSULE LIFT ,PASSENGER LIFT,FIRE LIFT AS PER IS STANDRADS,NBC CODES OF LIFTS ,SAFETY STANDARDS WITH ALL NECESSARY ELECTROMECHANICAL EQUIPMENTS,VVVF DRIVE CONTROL SYSTEM ,AUOTMATIC RESCUE DEVICE,APPROVAL OF PWD LIFT INSPETOR NECESSARY APPROVALS.SITC of Electric Traction Passenger/Stretcher/Fire Lift with
Location of Lift Machine:- MR/MRL
Rated speed :- 1.0mps VS UPTO 6 FLOOR & 1.5-1.75 MPS ABOVE 6TH FLOOR Car/Landing door clear opening of 1100/1200 mm wide x 2000 mm
Clear Car size of ......mm wide x ......mm deep x 2250mm high
Lift shaft available having clear size of ......mm wide x ......mm deep,
......mm Pit depth, ………mm Overhead.
· Doors type :- COPO/TOPO Doors with frame made from SS 304 grade
solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing
doors with SS door architraves/frames The lift doors shall have minimum 1
hour fire rating (with submission of necessary valid test certificate issued
by NABL accredited or Independent test laboratory)
· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of
1.5mm, thick with hairline finish with frame made from MS girders, bracing of
adequate size with minimum safety factor of 5, with Toe Guard Apron, with
necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS
chequered plate flooring, handrails, mirror, emergency light etc. The lift car
interior design shall be done as per the directions of engineer in charge.
· COP with SS face plate having metallic push buttons with Braille code &
luminous indicator around button with FPI, scrolling UP/DN LED indicator &
with / without attendant key switch, OWD with audio-visual alarm, VAS in
Marathi, Hindi & English with intercom system with telephone instrument in Lift
car, LMR & FCC/ground floor.
· LOP with SS face plate having recess/surface push button box for all
landings with scrolling UP/DN LED indicator having metallic push buttons with
Braille code & luminous indicator around button with CPI, Lift car arrival & next
travel direction audio-visual indication at all landings.
Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. ·
Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with · Rated capacity :- 20 Passenger/1360Kg · Floors :- G+12 floor (12 Stops/12 Landings) · Travel :- 21 to 29.4 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.5mps VS · Car/Landing door clear opening of 1100/1200 mm wide x 2000 mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep, ......mm Pit depth, ………mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
For Main Atruim
SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with · Rated capacity :- 15 Passenger/1020Kg · Floors :- B 3 Nos.+G+12 floor (16 Stops/16 Landings) · Travel :- 21 to 29.4 mtrs · Location of Lift Machine:- MR/MRL [applicable for Passenger Lift with MRL only & Stretcher/Hospital Lift with MR & MRL] · Rated speed :- 1.5mps VS · Car/Landing door clear opening of 800/900/1000 mm wide x 2000mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
For Main Atruim
SITC of Electric Traction Passenger Lift with 1386712 · Rated capacity :- 13 Passenger/884Kg · Floors :- B1+B2+B3+G+1 floor (5 Stops/5 Landings) · Travel :- 3 to 4.2 mtrs. · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 900/1000 mm wide x 2000 mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep
For Lift having 1200mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.
SITC of Triplex Lift control system for three nos. microprocessor/PLC
based simplex lift controllers along with necessary software with programming
and hardware e.g. logic board, necessary communication/control/data cabling
laying in rigid PVC conduits/trunking etc. complete.
FOR OFFICE LIFTS 3B+G+1ST FLOOR=5 STOPS
SITC of Electric Traction Passenger Lift with · Rated capacity :- 8 Passenger/544Kg · Floors :- G+12 floor (13 Stops/13 Landings) · Travel :- 21 to 29.4 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.5mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep
For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope, landing doors with all accessories etc. complete for the safe functioning of lift installation.
For Fire service G+12 Floor=13 stops
Design, Supply, Installation, Testing & commissioning Underground sewage treatment plant with all electromechanical equipment’s of capacity 300 KLD in MBBR technology (Moving Bed Biofilm Reactor technology)
Complete design as per IS Norms &NBC Codes ,Supplying of Electro Mechanical equipment, pipe fittings, erection, installation, testing
and commissioning MBBR technology Sewage Treatment Plant (Capacity 300 KLD) -This treatment scheme should be designed to treat the sewage generated having following
characteristics:-
A) INLET CHARACTERISTICS FOR SEWAGE
Flow 300 m3/day
Average Flow 12.5 m3/hr on 24 hrs Basis
Discharge period 24 hrs
Peak Factor 3.0
Peak Duration 3.0 hrs
Peak Flow 37.5 m3/hr.
BOD5 @ 200C 250 mg / litre
COD 500 mg / litre
TSS 250 mg / litre
Temperature 250C (Max)
O&G < 50 mg/ litre (Max)
Total Nitrogen 55 mg/litre
Ammonical Nitrogen 45 mg/litre
Phosphates < 10 mg/litre
B) TREATED SEWAGE CHARACTERISTICS AFTER ACTIVATED CARBON FILTER:- PH 6.5 – 8.5 BOD5 @ 200C < 5 mg / litre COD (Cr) ≤ 30 mg / litre TSS ≤ 10 mg / litre O&G < 10 mg/ litre
C) TREATED SEWAGE CHARACTERISTICS AFTER NUTRIENT REMOVAL (ADD-ON):-
Total Nitrogen ≤ 10 mg/litre
Ammonical Nitrogen ≤ 5 mg/litre
Phosphates < 2 mg/litre
Designer chandelier for Atrium
COMPLETE DESIGN, SUPPLY, ERECTION TESTING & COMMISSIONING OF DESIGNER CHANDELIER WITH IMPORTED CRYTALLS SIZE SUITABLE FOR THE ATRUIM GROUND FLOOR AREA & HEIGHT OF THE ATRUIM INCLUDING ALL NECESSASRY LAMPS, CRYSTALLS, SSROPE FOR INSTALLATION ON SKY LIGHT AREA ETC WITH 5 YEAR WARRANTY.
AUTOMATIC GLASS DOOR SYSTEM FOR MAIN ENTRANCE
SITC OF Automatic Door Door Opening 2.4x3.6 mtr.(WxH) Each Set is Inclusive of:
1. Digital Control Automatic Door Operator
2. Microwave Motion Sensors
Door Actuator For Automatic Opening And Closing
3. Photocells
To Prevent Door From Closing If an Object is caught Between Doors
4. Aluminum Base Rail 01 no.
5. STS Timing Belt ( Super Torque Synchronized ) 01 no.
6. Manual release in case of Power failure 01 no.
7. Hanger roller Assembly :- 04 nos
8.Bottom Guide for Sliding Door :- 01 no.
9. Glass holding clamps 04 nos.
10. Belt connector pulley 01 no.
11. Door motor 01 no
FOR Main entrance doors
SITC Lift Car Interior similar to Capsule type with rear glass view (toughned glass) for 15/20 Passenger lift as per specifications & approval by EIC( Item applicable for Sr No.506 & 507)
Nyati Engineers And Consultants PVT Ltd
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid