Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 CrAccepted-Finance | ₹12.6 Cr | L1 | Accepted-Finance Send to AOC |
| 2 | L2₹12.6 CrRejected-Finance | ₹12.6 Cr | L2 | Rejected-Finance EMD Refund |
| 3 | Rejected-Technical | - | - | Rejected-Technical DisQualified in PQ |
| 4 | Rejected-Technical | - | - | Rejected-Technical DisQualified in PQ |
Tender Value
₹15.1 Cr
EMD Value
₹10 L
Closing Date
1 Dec 2025, 5:30 pmClosed
Chief Engineer
CE PWD REWA ZONE REWA
Construction of Bahuti to Karah Pahari Basti, approach road length 17.30 km, under sub-division Mangawan.
2025_PWDRB_460707_1
08/Gen./2025-26 Dt. 04-11-2025
Open Tender
Civil Works - Roads
305 days
Rewa
Please refer tender document
4 documents required · 4 mandatory
₹30,000
₹10 L
13 Mar 2026
10 Nov 2025
3 Dec 2025
10 Nov 2025
1 Dec 2025
10 Nov 2025
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffoldingwherever necessary, sorting the dismantled material, disposal of unserviceable material andstackingthe serviceable material with all lifts and lead of 1000 metres.Cement Concrete Grade M-15 & M-20
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres.Removing all type of hume pipes and stacking within a lead of 1000 metres including earthwork and dismantling of masonry works.Above 600 mm to 900 mm dia for HPC
Dismantling of Cement Concrete PavementDismantling of cement concrete pavement by mechanical means using pneumatictools, breaking to pieces not exceeding 0.02 cum in volume and stock piling Serviceable material at designated locationsand disposal of unserviceable materials up to a lead of 1000 metres,
Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300.
Providing and laying reinforced cement concrete pipe NP-4 for service ducts below concrete pavement.
Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller to clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications.
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13and as per clause of section 406 of specifications.
Providing and applying primer coat with catonic bitumen emulsion on prepared surface of granular Base including cleaning of road surface and spraying primer at the rate of 0.70 to 1.00 kg/sqm using mechanical means as per clause 502 of specifications.
Providing and applying tack coat with cationic bitumen emulsion using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications0.30 kg per sqm (dry & hungry bituminous surfaces /granular surfaces treated with primer).
Providing and laying dense bituminous macadam using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a Electronic Sensor paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per clause 505 of specification complete in all respectsfor GradingII(19 mm nominal size) Bitumen Content minimum 4.5%with bitumen 60/70 (VG 30).
Providing and laying bituminous concrete using crushedaggregates of specified grading, premixed with bituminousbinder @ 5.4 to 5.6 % by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a Electronic Sensor paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratoryand tandem rollers to achieve theor Grading-II ( 30-45 mm thickness ) Bitumen Content minimum 5.4% with 60/70bitumen(VG-30)
Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc
Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc
Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT &H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor. Note: - Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board.
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT &H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor. Note: - Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board.
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT &H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor. Note: - Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board.
roviding and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2022 clause 6.7.4.3 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT&H specification of in the clause 6.8 of theIRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on 2 nos. of MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor. .
Providing and applying (Cleaning of Bituminous surface)thermoplastic compound having composition of binder (Regin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of2.5 mm is exclusive of surface applied glass beeds as perIRC:35.The finished surface to be level, uniform and free fromstreaks and holes, all complete as per clause 803 of specifications.
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. as per relevant clauses of section 300 & 2100 in
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. as per relevant clauses of section 300 & 2100 in Ordinary rock (not requiring blasting)
PCC M-15 in Foundation Plain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409.
Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900.
Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.
Laying Reinforced Cement Concrete Pipe NP 4 /prestrssed concrete pipe on first class bedding in double row. Providing and Laying Reinforced cement concrete pipe NP4 /prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification
Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.
Provdiing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with .
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications
Furnishing and Placing inforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 in
Providing and laying Cement concrete wearing coat 75 mm thick with M-30 grade concrete with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 19 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with static paver, spread, compacted and finished with power trowel in a continuous operation including provision of admixtures asapproved, curing compound, finishing to lines and grades as per drawing but including cost of steel etc. including reinforcement,
texuring with texuring brush complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications..
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technicaspecifications and as per relevant clauses of section 1600. FE-500
Supplying, fitting and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications and as per relevant clause of section 1600.( FE - 500 )
Supplying, fitting and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications as per relevant clauses of section 1600
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix 6 of IRC-78.
Providing and fixing in position bituminous paper bearing for slabs as per approved drawing and confirming to IS:1398.
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications and as per relevant clauses of sections 1500, 1600, 1700 and clause 2703 of specifications (as per MoST specification drawing SD/201 or SD/304)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 35.24 MB
Tendernotice_2.pdf
PDF • 0.88 MB
BOQ_542966.xls
BOQ • 0.97 MB
Download all tender documents and submit your bid