Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC NIRMAL NIKETAN OLD GANGAPUR NAKA GANGPUR ROAD SHREENAGAR NASHIK 422013 | NASHIK | MAHARASHTRA | 422013 | ₹35.1 L Quoted ₹37.0 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹40.0 LRejected-Finance 18TH FLOOR FL NO 1801 PANCHASHEEL HEIGHT MAHAVEER NAGAR KANDIVALI WEST MUMBAI 400067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹40.0 L | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹40.4 LRejected-Finance 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | ₹40.4 L | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹42.7 LRejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹42.7 L | L4 | Rejected-Finance BEING L4 |
| Sl No | Description | Qty | Unit | Vishal Builders L4 | KAJAL CONSTRUCTION L2 | NIKAASH INFRACON L1 | KRISHNA ENGINEERS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed. | 403 | Sqm | 40 ₹16,120 | 9 ₹3,627 | 20 ₹8,060 | 10 ₹4,030 |
| 2.00 | Taking down old u/s steel plates of any thickness, complete all as specified and directed. | 180 | Sqm | 50 ₹9,000 | 9 ₹1,620 | 20 ₹3,600 | 5 ₹900 |
| 3.00 | M&L for fire resistant (4 hours fire rated) 12mm thick calcium silicate board three layer fixed in ceiling and GI sections 0.55mm thick in ceiling portion of grid 610 x 610mm complete all as per manufacturers instructions of approved colour, type complete including false ceiling system consisting of powder coated exposed GI grip suspension system and shall be supported by 4mm dia GI rods from ceiling and fixed complete all as specified and as directed.
Note : Certificate from manufacturer shall be submitted for fire rating before execution of work. | 150 | Sqm | 1,800 ₹2.7 L | 1,100 ₹1.6 L | 2,050 ₹3.1 L | 2,300 ₹3.5 L |
| 4.00 | M&L for 12mm thickness wall panelling of Fire Proof board ( 4 hours fire rated) of Hilux - Calcium silicate board three layer all as directed incl GI sections of size 50mm x 0.55mm thick or as per manufacturer instructions including all necessary fitting fixtures to fix panelling on wall annexures , including channels required to fix boards over walls horizontally & vertically inclusive of screws etc,. & necessary corner channels required at door / window openings, corners etc. All joints of boards will be filled with jointing compound and fiber tape all as per instructions of manufacturer. After fixing of boards, surface of boards will be prepared by fine sand paper & apply one coat of oil based cement primer over the boards as directed, all as per manufacturer instructions all complete as directed.
Note : Certificate from manufacturer shall be submitted for fire rating before execution of work. | 150 | Sqm | 1,800 ₹2.7 L | 1,200 ₹1.8 L | 2,200 ₹3.3 L | 2,300 ₹3.5 L |
| 5.00 | Taking down cement plaster of any description on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified & as directed. | 1,200 | Sqm | 30 ₹36,000 | 30 ₹36,000 | 30 ₹36,000 | 5 ₹6,000 |
| 6.00 | M&L for rendering 10mm thick CM 1:3 on fair faces of concrete surface and finished surfaces even and smooth without using extra cement complete all as specified and directed. | 100 | Sqm | 220 ₹22,000 | 225 ₹22,500 | 220 ₹22,000 | 220 ₹22,000 |
| 7.00 | M&L for rendering 15mm thick CM 1:6 on fair faces of brickwork or concrete surface and finished even and smooth without using extra cement, complete all as specified and directed. | 800 | Sqm | 220 ₹1.8 L | 210 ₹1.7 L | 230 ₹1.8 L | 300 ₹2.4 L |
| 8.00 | M&L for cement plaster, 20mm thick in two coats (15 mm thick in CM 1:4 +5 mm thick in CM 1:4) ) with using integral waterproofing compound (in second coat) finished even & smooth without using extra cement ,complete all as specified and as directed by Engr-in-charge.
Note: Integral liquid water proofing compound to be used in per bag of cement shall be as per manufacturers instructions and paid separately under respective items. | 300 | Sqm | 500 ₹1.5 L | 280 ₹84,000 | 300 ₹90,000 | 400 ₹1.2 L |
| 9.00 | Supply only integral water proofing compound. | 30 | Kg | 60 ₹1,800 | 55 ₹1,650 | 48 ₹1,440 | 60 ₹1,800 |
| 10.00 | Removal of existing concrete including loose/weak concrete from the concrete structure i.e. beams/ columns/ deck slab etc upto beyond corroded steel reinforcements to a depth of minimum 10mm behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around the corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid featheredging and to provide a square edge complete all as specified and directed by Engr-in- Charge.
Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation. | 50 | Sqm | 60 ₹3,000 | 50 ₹2,500 | 60 ₹3,000 | 40 ₹2,000 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
9 Sept 2025, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
IMPROVEMENT IN EXISTING INFRASTRUCTURE OF 768 SU AT AFS MADH ISLAND UNDER GE(AF)THANE
2025_MES_725825_1
GE (AF) T-25 OF 2025-26 (8497)
Open Tender
Civil Works
180 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹87,000
Yes
4 Feb 2026
12 Aug 2025
17 Sept 2025
12 Aug 2025
9 Sept 2025
27 Aug 2025
Amount
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
Taking down old u/s steel plates of any thickness, complete all as specified and directed.
M&L for fire resistant (4 hours fire rated) 12mm thick calcium silicate board three layer fixed in ceiling and GI sections 0.55mm thick in ceiling portion of grid 610 x 610mm complete all as per manufacturers instructions of approved colour, type complete including false ceiling system consisting of powder coated exposed GI grip suspension system and shall be supported by 4mm dia GI rods from ceiling and fixed complete all as specified and as directed. Note : Certificate from manufacturer shall be submitted for fire rating before execution of work.
M&L for 12mm thickness wall panelling of Fire Proof board ( 4 hours fire rated) of Hilux - Calcium silicate board three layer all as directed incl GI sections of size 50mm x 0.55mm thick or as per manufacturer instructions including all necessary fitting fixtures to fix panelling on wall annexures , including channels required to fix boards over walls horizontally & vertically inclusive of screws etc,. & necessary corner channels required at door / window openings, corners etc. All joints of boards will be filled with jointing compound and fiber tape all as per instructions of manufacturer. After fixing of boards, surface of boards will be prepared by fine sand paper & apply one coat of oil based cement primer over the boards as directed, all as per manufacturer instructions all complete as directed. Note : Certificate from manufacturer shall be submitted for fire rating before execution of work.
Taking down cement plaster of any description on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified & as directed.
M&L for rendering 10mm thick CM 1:3 on fair faces of concrete surface and finished surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick CM 1:6 on fair faces of brickwork or concrete surface and finished even and smooth without using extra cement, complete all as specified and directed.
M&L for cement plaster, 20mm thick in two coats (15 mm thick in CM 1:4 +5 mm thick in CM 1:4) ) with using integral waterproofing compound (in second coat) finished even & smooth without using extra cement ,complete all as specified and as directed by Engr-in-charge. Note: Integral liquid water proofing compound to be used in per bag of cement shall be as per manufacturers instructions and paid separately under respective items.
Supply only integral water proofing compound.
M&L for preparation of new plastered or unplastered surfaces of walls including scrapping and applying two coats of distemper oil emulsion over a coat of 2mm thick wall care putty, complete all as specified and directed.
M&L for Preparation of new plastered/ rough plastered surfaces of wall and apply two coats of Premium Acrylic emulsion exterior paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces in camouflage pattern, complete all as specified.
M&L for preparation of new plastered or unplastered surfaces of ceiling and apply two coats of distemper oil emulsion over a coat of 2mm thick wall care putty, complete all as specified.
M&L for complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over 1 mm thick wall care putty on walls complete all as specified.
Preparation of old wall surfaces and apply two coats of Premium Acrylic emulsion exterior paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. , complete all as specified.
M&L for preparation of old plastered or unplastered surfaces of ceiling and apply one coats of distemper oil emulsion, complete all as specified.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
M&L for machine cut polished cuddappa stone slab 20 to 25 mm thick as in cills/jambs, cooking platform of window & door openings, set jointed and pointed in neat cement slurry with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete, complete all as specified.
M&L Granite slab work 18 to 20mm thick in floors steps, platforms, shelves etc and fixed over cuddappa stone by using aerolite adhesive complete all as specified and directed
M&L for 2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
M&L for 18mm thick Block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face, fixed with screws to timber frame or to hinges, complete all as specified.
S & F Continuous (piano) hinges, 30mm width of flaps, mild steel, bright finish or electrogalvanized, complete all as specified.
M&L for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks,removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m, complete all as specified.
M&L for Forming jambs, etc. in CM 1:6 to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified.
M&L for brick work with sub class 'B' bricks , straight or curved on plan exc 6m mean radius built in cement mortar 1:6 all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, complete all as specified & directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, complete all as specified & directed.
S&F for ordinary sheet glass 4.8mm thick and glazing with oil putty/beddings in square exc 0.5 sq, in each panes, complete all as specified.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as directed.
Dismantling stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar, complete all as specified.
S&F Machine cut kata stone slab flooring 20-25mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
S&F Machine cut kata stone slab skirting 20-25mm thick over 15mm thick rendering in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
S&F as in repairs for Steel rolling shutters 1.25mm thickness of laths with ball bearings(3 nos), with gear operated type with bevel gear box and crank handle, including top cover, anchoring rod, hasp and staple and one shop coat of red oxide primer; erected in position as indicated, complete all as specified.
Dismantling wrought iron work of any description as in door / window frame and vertical poles as specified
Dismantling expanded metal, any thickness or mesh, fixed with steel or wood fillets, if any
Excavating in post holes (or similar holes) each n exc 0.5cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified.
S&F Joist, channel, angle, or tee sections, vertical posts, flat irons etc etc. confirming to Fe 410- W (Gde- E-250) quality -A, complete all as specified.
S&F Mild steel round bars bars 10mm dia and over, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified.
Supply only PVC coated ultraviolet resistant chain link fencing of size 50mm x 50mm and weight not exceeding 4 Kg/Sqm, complete all as specified.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long and n.exc 10cm long and dia 11 to 15 of neck, complete all as specified.
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified.
M&L for 100mm thick cement concrete type B-2 1:2:4 as in floors, pavings etc and finishing cement concrete surface even and smooth , and making impressions of expended metal, whilst the concrete is green, complete all as specified.
M&L for 75mm thick cement concrete type D2 1:4:8 as in sub bases, sub floors etc , complete all as specified.
M&L for rubber moulded glossy finish coloured chequered cement concrete tiles of size 30cm x30 cm x 25mm thickness, set and jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in CM 1:6, complete all as specified.
Demolition of RCC in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified.
Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately)
S&F for Framed brackets of angles, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe.290.Gde-E-165, complete all as specified.
Supply and fix Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, in chajjas fixed with self tapping screws all as specified.
M&L for Framed work Fe 410 -W (Gde- E- 250) quality- A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
S&F plates (plain or chequered ) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified.
M&L preparation of new Steel surface synthetic enamel paint of two coats in any description, over a coat of red oxide, zinc chrome, specified and directed.
Taking down chowkats or frames with shutters ( without taking off shutters from the frame) exc 1.5 Sqm but n exc 4 sq. m each, complete all as specified.
Taking down chowkats or frames with shutters ( without taking off shutters from the frame) n.exc 1.5 Sqm each, complete all as specified.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm (double door chowkate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as specified. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F 100mm size stainless steel butt hinges, extruded pin, anodised, complete all as specified. Make : Shalimar, Deepak or ISI marked.
S&F 150mm long aluminium anodized barrel tower bolts of extruded section. Make : Classic, Shalimar or equivalent ISI marked
S&F 150mm extruded aluminium alloy handles fabricated type anodized. Make : Classic, Shalimar or equivalent ISI marked
S&F 250mm length Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. Make : Classic, Shalimar or equivalent ISI marked
Dismantling floor hearth or wall tilling including cement mortar bedding ( but not backing) all as specified.
M & L Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6), complete all as specified.
M&L coloured non-skid ceramic tiles 7-8mm thick rectified glossy (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in skirting etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick rendering in CM (1:4), complete all as specified and directed.
M&L, Coloured Glazed ceramic tiles (Matte & Design as approved) of size 450X 300X 7mm laid on vertical surface such as dado/skirting over cement mortar backing coat, set jointed in neat cement slurry and pointed in white or coloured cement including 15mm thick backing coat in CM 1:4 , complete all as specified.
Removing existing water proofing treatment what so ever exist (except concert padding) and removing debris/ rubbish materials off the site complete all as specified and directed.
M&L for APP modified roof treatment over existing RCC roof with following specification :- (a) Applying bitumen primer @ 0.4 Litres/Sqm with density of 0.87 to 0.89 Kg/Litres at 25 degree C on the prepared dry roof surface. (b) Laying 3 mm thick APP membrane weight not less than 3.50 Kg/Sqm by torch application with minimum 10cm side lap and 15cm end lap. The laying of membrane shall be done through an authorised applicator of manufacturer of APP membrane.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
Supply and Fixing of Vitreous China urinals, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)
Taking up or down 15mm bore steel tubing and connections, complete all as specified.
Taking up or down 20mm bore steel tubing and connections, complete all as specified.
S&F 15mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls ( concealed) and ceilings or laid in floors, complete all as specified.
S&F 20mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls (concealed) and ceilings or laid in floors , complete all as specified.
S&F as in repairs 20mm bore dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified.
S&F as in repairs Vitreous China wash down water closet pan (pedestal pattern), including Plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified.
S&F as in repairs health faucet (ABS Body mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F 10 ltr capacity PVC low level flushing cistern 10 litre capacity with 32mm bore polythene flush pipe of sufficient length including internal fitting (valve less syphonic) etc. complete fixed as in repairs.
S&F as in repairs Vitreous China wash basin, white, flat back, size 550 x 400mm including brackets or fixing with bolts in wall , 15mm fancy pillar tap, waste coupling, waste pipe, complete all as specified.
S&F 40mm bore of High density poly ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 incl fittings (bend, tee etc) fixed complete to walls, ceilings or in floors etc., complete all as specified.
S&F as in repairs 15mm bore dia Bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed , complete all as specified.
S&F as in repairs 15mm bore dia Stop valves, CP cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed.
S&F as in repairs Door closer hydraulically aluminium extruded regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
Removing building materials etc. to a distance of upto 60 KM beyond the lead included in the rates, including loading, unloading and stacking at the destination,(All demolished material disposed off as per BMC guidelines at location marked by BMC).
Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose's lamp holder from existing batten PVC conduit/steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing ,complete all as specified and as directed
M & L for point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC casing & capping , hooks , elbows, junction covers and junction boxes , after cutting in wall and sinking's for modular metal flush boxes suitable length and Min 1.6 mm thickness, Min 51 mm depth for mounting, switches, sockets, fan regulator with modular cover plate with frame and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and directed
All as per Srl item No -94 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed
All as per Srl item No -94 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed
All as per Srl item No. 94 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed
S & F in replacement modular switch 5/6 Amps single pole one way,one module including modular cover plate with frame and metal flush box complete all as specified and directed
S & F in replacement modular switch 15/16 Amps single pole one way,one module including modular cover plate with frame and metal flush box complete all as specified and directed
S & F in replacement modular socket 2/3 pin, type 5/6 Amps 5 in 1 flush type including modular cover plate and metal flush box with frame complete all as specified and directed
S & F in replacement modular socket 2/3 Pin, 6/16 Amps flush type including modular cover plate with frame and metal flush box complete all as specified and directed
Supply and fix in replacement industrial socket metal clad plug and socket with MCBs single pole 20 Amp complete all as specified and directed
S & F modular stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete including modular cover plate with frame and metal flush box complete all as specified and directed
S & F ceiling rose surface bakelite three terminals complete all as specified and directed
Taking down carefully existing serviceable LED Tubelight/ bulkhead/ security light/Exhaust fan/ wall fan/ ceiling fan recess mount fitting of any size and refixing the same to respective location after carrying out cleaning all the components of fittings, including replacement of nuts, bolts and connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed
S & F in replacement LED Tubelight fitting with aluminium housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, surge protection min 4 KVA and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed .
Supply and fixing LED street light fitting 35 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed
S&F in replacement LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. All as specified and directed
S & F in replacement LED Water tight bulk head fitting 10 W,comprision of connector galvanised cast iron back plate, weather proof enamelled gallery ,glass well, and including 10 watt LED all as specified and directed
S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. all as specified.
S & F in replacement angle holder insulated body with back plate for conduit fittings complete all as specified and directed
S&F LED lamp 9W for angle holder complete all as specified and directed
S & F in replacement for Sub Main wiring with two single core 6 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing capping conduit with and including PVC insulated 6 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed (Note : PVC cable and PVC casing capping shall be ISI marked) Note :- Two length of 6 Sqmm cable and one length of 6 Sqmm earth cable along with PVC casing capping will be measured as one running length
S & F in replacement for Sub Main wiring with two single core 4 Sqmm PVC insulated FRLSH multistranded flexible copper conductor cable 660/1100 volts grade drawn in through flexible non metallic PVC casing capping conduit with and including PVC insulated 4 Sqmm multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly ,complete all as specified and as directed (Note : PVC cable and PVC casing capping shall be ISI marked) Note :- Two length of 4 Sqmm cable and one length of 4 Sqmm earth cable along with PVC casing capping will be measured as one running length
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 12 ways, 415 Volts, ISI marked 200 amps bus bar stove enamelled dust and vermin proof, IP42 and above suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessity complete all as specified and directed .
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 16 ways, 240 Volts, ISI marked 200 amps bus bar stove enamelled dust and vermin proof, IP 42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessity complete all as specified and directed
S & F in replacement sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked 200 amps bus bar stove enamelled dust and vermin proof, IP 42 suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessity complete all as specified and directed
S & F in replacement MCB ‘B’ series type suitable for 415 volts, 10 KA, AC supply 40 to 100 Amps, triple pole and neutral (TPN) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 6 to 32 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed
S & F in replacement MCB ‘B’ series type suitable for 240 volts,10 KA, AC supply 6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed
Material and Labour for 20×3mm copper strip with suitable GI pipe etc from test terminal block to earth pit complete all as specified and directed.
Disconnecting electric connection and taking down carefully serviceable ceiling fans, exhaust fan, wall fan and keep in safe custody. After the building repair work or as directed refixing /hanging the ceiling fan including electric connection with and including new flexible sheathed copper wire 3 core from ceiling rose/connector to fan connector, including in replacement new nut bolts, rubber reel, capacitor 2.5mfd, machine screws and split pins etc including painting the ceiling fan complete body with blades, canopies, down rod etc. with synthetic enamel paint by spray gun after scraping down old paint in colour as directed complete all as specified
Material and labour for servicing of Split type ACs of any size/capacity by disconnecting the electrical/water connections, taking out from its position, cleaning the external dirt & dust, cleaning air filter, condenser, washing by water jet, drying by air blower, checking all electrical connections and refixing in existing position including all additional the connected items need to repair ( copper pipe , water drain pipe, stand etc.) and testing, complete all as directed
S&F Heavy duty metal body exhaust fan of 300mm sweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to disturbed wall in cement mortar (1 :4) white washing matching with existing colour etc.
S&F Heavy duty metal body exhaust fan of 450mm sweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to disturbed wall in cement mortar (1 :4) white washing matching with existing colour etc.
S&F ceiling fans AC single phase 230/240 V of size 1200 mm sweep without regulator having Min air delivery 210 CFM with service value 6.00 BEE 5 star rated with brushless direct current motor (BLDC) complete with electrical connection providing three core round flexible copper conductor cable of suitable size complete all as specified and directed .
S&F wall mounting fans for 230 volts single phase 400 mm sweep complete all as specified and directed
Dismantling and Taking down L.T. under ground armoured PVC/XLPE insulated and PVC/XLPE sheeted heavy duty 1100 Volts grade under ground cable of any size complete all as specified and directed.
Taking out serviceable unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm during excation of trenches and relaying after cable laying in trenches all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in hard/dense soil complete all as specified and directed .
Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer complete all as specified and directed.
Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point complete all as specified and directed.
Supply and spreading in trenches clear dry sand for cable protection and punning down gently 10 cm below the cable and 15 cm above the cable all as specified and directed. Note :- Punning thickness only measured.
Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 ISI marked flat size 250x150x40 mm laid in trenches as specified and as directed.
Supply and lay jointing and testing and commissioning in replacement of 35 Sqmm x 3.5 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed
Dismantling and refixing old GI strip/Copper Strip of any type and size complete all specified and directed.
M&L for Brazing of copper/GI strip joints for copper strips of any size complete all as specified and as directed
S & F in replacement Porcelain insulator with nut bolt and washer suitable for fixing copper/gi/aluminium strip on wall or ceiling
M & L for Air termination, single pointed, Copper rod 12 mm dia and 300 mm long complete all as specified and directed
M & L for providing test point terminal block, made out of Gun metal or Phosphors bronze, of Size 75 mm X 75 mm X 25 mm drilled and screwed including 03 Nos 8 mm dia, 25 mm long hexagonal head screws complete all as specified and directed
M & L for Aluminium strip 25 mm X 3.15 mm with saddles and fixing screws etc as in roof conductors and down conductor above ground complete all as specified and directed
M & L for GI strip 32 mm X 6 mm buried in ground complete all as specified and directed
M & L for GI water tubing, light grade,50 mm,1.2 m long duly threaded on one side in and including fixing of GI socket for fixing of Air termination and including FI clamp of 50 X 6 mm bend to shape for fixing of GI pipe post and fixed to wall (GI pipe 1.2 m will be in single length and no joint will be allowed). Complete all as specified and directed
M&L for steel water tubing medium grade of size 25 mm bore with all fittings laid in trenches or fixed to wall or floor. Complete all as specified and directed
M& L Cutting existing steel tubing for alterations or additions 40m or 50 mm size , Add if necessarily done in position without taking down.
S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
Supply & fixing in replacement of meter box enclosures size (0.9 mX0.9 mX0.25m) made of Polycarbonate shall have Opaque base & Transparent cover, should be weather/ vermin proof, anti-acid, anti corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing accordance with IEC 6069 5-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The meter boxes should be modular and compartmentalized in construction with opaque and transparent cover, properly tightened to base with thermoplastic/SS304 screws /Nuts & bolts having sealing gasket made of extruded silicon rubber to withstand adverse weather effects. The depth of modular meter enclosures should be above 200mm for air circulation & to minimize temp rise during peak Indian summer ambient temperature of 45+ Deg C, lock arrangement ,transperent glass for meter reading, suitable for fixing Electric meter & TPN DB box including taking down existing electric meters , refixing them with four single core PVC copper conductor unsheathed wire multistranded 6 sqmm,properly painting on meter box complete and fixing in wall with suitable cutting,cement work etc complete all as specified and directed
M&L in repairs fire alarm system conventional 4 zone FAP control panel complying ,complete all as specified and directed.
Supply and fix 3 pin telephone socket RJ 11 with metal flush box having holes for 20 mm conduit entry for telephone connection all as specified and directed
M&L in repairs MCP conventional ABS complete all as specified and directed.
M&L in repairs Electronic Hooter 24 Volts DC complete all as specified and directed.
M&L in repairs optical smoke detector complete all as specified and directed.
Supply and fixing PVC insulated heavy duty armoured copper conductor of size 2x1.5 sqmm cable for fire alarm ,complete all as specified and directed.
S & F casing & capping of tele communication wires of 4 inch width on wall fixing all as specified and directed.
KAJAL CONSTRUCTION (BID ID -3414279)
KRISHNA ENGINEERS (BID ID -3420154)
Vishal Builders (BID ID -3420561)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid