RequiredExperience with Government Bid to RA enabled No Infusion Pump Volumetric/Syringe Based ( 5 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Availability of any of Certification such as ISO/European-CE US-FDA/CE YES YES Details of the Certifications such as type of certification
Requirednu mber
Requireddate and validity - * Conformity to YES * 1/6 Standards Performance Parameters Type of Infusion Pump Syringe Infusion Pump Volumetric Infusion Pump
RequiredSyringe Infusion Pump
RequiredVolumetric infusion pump with pneumatic pressure compensating for gravity Technology (of operation) Programmable Mode Programmable Mode
RequiredContinous Mode Flow rate Range with increment in ml/hr 0.1-99.9 ml/hr(0.1 ml/hr increment) for Volumetric Infusion Pump Only 0.1-99.9 ml/hr(0.1 ml/hr increment) for Volumetric Infusion Pump Only
Required1-1200 ml/hr(1 ml/hr increment) for Volumetric Infusion Pump Only
Required0.1 to 240 ml/hr(10 ml syringe)
Required1.1 to 400 ml/hr(20 ml syringe)
Required1.1 to 600 ml/hr(30 ml syringe)
Required1.1 to 840 ml/hr(50 ml syringe)
Required1.1 to 999 ml/hr(100 ml/hr syringe) Infused Volume Range in ml 0.1-999(0.1 ml/hr increment) 0.1-999(0.1 ml/hr increment)
Required1-9999(1 ml/hr increment) Flow rate & volume flow rate & volume to be infused should be configured to limit the maximum allowable range * KVO (Keep Vein Open) Rate in ml/hr 3 Up to 5 Accuracy in % 2 Any applicable numeric value Bolus Type Bolus with volume pre- selection Bolus with volume pre- selection
RequiredBolus without volume pre-selection
RequiredInterval Bolus
RequiredPurge Bolus ( For Syringe based)
RequiredAuto Bolus (For Syringe based) Bolus Rate Range in ml/hr 800 ml/hr for 50 ml syringe 1-600 ml/hr ( for Volumetric type infusion set)
Required200 ml/hr for 10 ml syringe
Required360 ml/hr for 20 ml syringe
Required560 ml/hr for 30 ml syringe
Required800 ml/hr for 50 ml syringe
Required999 ml 2/6 hr for 100 ml syringe Bolus Volume in ml 0.1 ml to 5 ml in 0.1 ml increments(auto bolus) 0.1-99.9/500 ml
Required0.1 ml to 5 ml in 0.1 ml increments(auto bolus)
RequiredNA for Purge bolus Display Type LCD LCD
RequiredLED
RequiredVFD
RequiredTouch Screen Size of Display (length x width) (mm x mm) - * Contents of Display - * Alphanumeric Programming Key Board YES * Operating and Transportation Temperature range - * Humidity Conditions (operating and transport & storage) (15 to 90%) YES * Pressure Conditions(operating and transport & storage) (50 to 106 kpa) YES * Power sources Battery operated * Battery Type Reachareable lithium polymer Reachareable lead- acid
RequiredReachareable lithium polymer Battery Rating - * Battery run time at normal delivery rate in hours 8 * Battery run time at highest delivery rate in hours 2-3 hrs * Battery recharge time (full charge) in hours 3 * Power Supply 220-240 V AC
Required50 Hz) (3 wire grounded system) YES * Eectrical Protection (Class I
RequiredType CF) YES * Fuse Type 220V 2A*2
Required12V 2A*2 2*T63 Ma 250V
Required220V 2A*2
Required12V 2A*2 Maximum Power Consumption in watt 20 * 3/6 Fitting of device on the IV bottle and bag No Yes
RequiredNo IR Sensor to detect the abnormality in IV Bag or bottle No Yes
RequiredNo Audible and Visual alarm facility Should have an audible and visual alarm wtth automatic pump stop function for the following : pressure drop
Requiredair standby
Requiredvolume infused
Requireddoor open
Requiredbattery Pre- alarm
Requiredrecall
Requiredinvalid rate
Requiredempty etc * Availability of Infusion mode setting(rate mode
Requireddrip mode
Requiredwait mode
Requiredtime mode) Yes Yes
RequiredNo Protection against fluid ingress - IP*1 - Protected against vertically falling drops of water YES YES Capability of Motioning of empty Intravenous bags or bottles No Yes
RequiredNo Warranty in Years 3 1
Required2
Required3
Required4 Dimensional & Material Parameters Dimension (Excluding power cables)(mm x mm x mm) - * Weight(with clamp base)in kg 1.8 * Material (Outer Shell) ABS PLASTIC * Additional Parameters Pole clamp Multi- function mounting clamp YES * Quick titration of rate or dose with volume timing programming YES * Compatible with any standard (PVC) infusion sets available in local indian market YES * Features : compatible with all standard syringes (b) excellent injection * 4/6 function and operation
Requiredeven small volume injection is accurate (c) dual cpu monitoring function (d)accurate and sensitive pressure sensor detects occlusion pressure accurately (e) smart pulsation compensation function No of infusion sets supplied with the single unit 0 * Packing (Individual) YES * Reports Type tests reports from a Central Govt lab OR International Laboratory Accreditation Cooperation (ILAC)or their worldwide affiliated/recognized labs OR NABL approved lab YES * Test Report No - * Test Report Date - * Name and complete address of the Lab - * Copy of certificates to be provided to buyer on demand after placement of order (Applicable if availability of test report indicated as YES
Requiredotherwise put NA) YES * * Bold specifications are the golden parameters.