Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹34.9 L+₹8.2 L (30.5%)Rejected-Finance | L2 | Rejected-Finance Rejected being not L1 | |
| 3 | L3₹36.5 L+₹9.7 L (36.2%)Rejected-Finance VILL BHANGERI PO ROORKEE PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | L3 | Rejected-Finance Rejected being not L1 | |
| 4 | L4₹38.7 L+₹12.0 L (44.8%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L4 | Rejected-Finance Rejected being not L1 | |
| 5 | L5₹39.3 L+₹12.6 L (47.1%)Rejected-Finance INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L5 | Rejected-Finance Rejected being not L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Nov 2023, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Roorkee
REPAIR/MAINT OF HIGH MAST LIGHT, STREET LIGHT, TIME PANEL AND CONNECTED ITEMS AT ROORKEE, SAHARANPUR AND PURKAZI UNDER GE ROORKEE
2023_MES_621670_1
8392/322/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ROORKEE
As per tender documents
8 documents required · 8 mandatory
₹500
GE (MES) ROORKEE
₹90,000
Yes
22 Feb 2024
5 Oct 2023
4 Nov 2023
5 Oct 2023
2 Nov 2023
19 Oct 2023
Amount
Supply & Fix in replacement Lamp holder,B-22 base with LED bulb 30 watts suitable for B-22 base or thread type, 5700K, fxed on post-top lantern fittings complete all as specified and directed. Make- Syska Cat No. SSK-HPB-40W or equivalent in Havells Cat No-LED FLORIDA ULTRA 30W, Philips Cat No-Tforce Core 47W/4000lmE27
Taking down carefully old unserviceable security light fittings from pole and S & F in replacment of security light fittings LED 25 watt with secondary lens luminaries IP 66, 5700K, with inbuilt surg diverter complete with all accessories as directed by Engineer-in-Charge. Make :Orient cat No. LSFT-025-C-PC, OR Havells Cat No-ENDURAPEARLSL25WLED 757SASYTOPCMP OR Crompton Cat No. TRP-400-25-57-SL-LM-NSR.
Taking down carefully old unserviceable security light fittings from pole and S & F in replacment of security light fittings LED 45 watt with secondary lens luminaries IP 66, 5700K, with inbuilt surg diverter complete with all accessories as directed by Engineer-in-Charge. Make : Orient cat No. LSFT-045-CT, OR Havells cat No-ENDURAPEARLNEOSL45WLED 757PASYTOPC or Crompton Cat No. TRP-409-45-57-SL-NS-GL-NSG.
Taking down carefully old unserviceable security light fittings and S & F in replacement of security light fittings suitable for LED 60 watt with lens complete with all accessories as directed by Engineer-in-Charge. Mare:- Orient cat No. LSFT-060-CT, OR ENDURAPEARLNEOSL60WLED757PASYTOPC or Crompton Cat No. TRP-409-60-57-SL-GL-NSG.
Taking down carefully old unserviceable security light fittings and S & F in replacement of security light fittings suitable for LED 90 watt with lens complete with all accessories as directed by Engineer-in-Charge. Make :- Orient cat No. LSFT-060-CT, OR Havells Cat No-ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or Crompton Cat No. TRP-411-90-57-SL-GL-NSG.
Taking down carefully old unserviceable light fittings and S & F in replacement of Flood light fittings suitable for LED 120 watt IP 66 with lens complete with all accessories as directed by Engineer-in-Charge. Orient Cat part No.LFSMU-120-C, and Havells Cat No-JETAIRISFLS 120WLED757APWBLT G OR Crompton Cat No- LFLN-120-CDL/60-M.
Taking down carefully old unserviceable light fittings and S & F in replacement of Flood light fittings suitable for LED 150 watt IP 66 with lens complete with all accessories as directed by Engineer-in-Charge. Orient Cat part No.LFSMU-150-C, and Havells Cat No-JETAIRISFLS 150WLED757PSYMLT G OR Crompton Cat No- LFLN-150-CDL/60-M.
Taking down carefully old unserviceable light fittings and Supply and fixing LED flood light luminaries of 250W, with pressure die cast aluminium housing with sealed toughened glass cover in frame ,IP 65 protection and with all fixing arrangement , nuts, bolts and washer connecting to electric system with 2.5 Sqmm PVC Aluminium stranded conductor 2 core up to require length and to be fixed on 11 Mtr long pole including taking down old unserviceable fitting any type and description complete all as specified and directed.
S & F in replacement of old unserviceable LED Highbay light fitting 100 watt capacity with PDC aluminium with reflactor including making electrical connection from ceiling rose to light fitting complete all as per Orient cat NoLHVXS-100-C, Havells SAUCERGENXPROHBP100WLED 757P60DBOLT G, Crompto Cat . LHB11-100-CDL/60-HPM. Note for Item No- 03 to 9 :- The Quoted rate is deemed to be included for installation of light fitting at any height (including High mast, Tower lights, Indoor sports complex etc.) including necessary T & P and safety equipments.
Supply and fixing PVC insulated PVC sheathed round work shop cable three core 1.5 Sqmm with multi stranded copper conductor for making connection from junction box to light fitting complete with suitable size copper lugs.
Supply and fixing PVC insulated PVC sheathed round work shop cable three core 2.5 Sqmm PVC Insulated with multi stranded Copper conductor for making connection from junction box to light fitting complete with suitable size copper lugs.
Supply only Driver for LED fitting 30 watt as per existing Make & Model
Supply only Driver for LED fitting 45 watt as per existing Make & Model
Supply only Driver for LED fitting 60 watt as per existing Make & Model
Supply only Driver for LED fitting 120 watt as per existing Make & Model
Supply only Driver for LED Flood fitting 50 watt as per existing Make & Model
Supply only Driver for LED Flood fitting 100 watt as per existing Make & Model
M & L in replacement for bracket made out of GI tubing 40 mm dia, light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 50mm wide 5mm thick MS flat iron with M.S nuts bolts 75 mm long 12 mm dia with -4 Nos & flat washer (3mm thick) 01 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete.
Supply & fix PVC Junction box of size 350 x 250 x 150 mm with Aluminium bus bars 04 Nos fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on existing pole to take out connections to fitting if required at site complete including provn of cable glands for incoming and outgoing cables all as specified. Make : Syntex/Hensel/Napture
Supply & fix PVC Junction box of size 250 x 200 x 105 mm with Aluminium bus bars 02 Nos fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on existing pole to take out connections to fitting if required at site complete including provn of cable glands for incoming and outgoing cables all as specified. Make : Syntex/Hensel/Napture
S&F MCB TPN 10KA, 63 Amps. Make:- Havells/Legrand/ABB/C&S
S&F MCB TP 10KA, 32 Amps. Make:- Havells/Legrand/ABB/C&S
S&F MCB SPN 20 to 32 Amp. Make:- Havells/Legrand/ABB/C&S
S&F MCB SP 6 to 32 Amp. Make:- Havells/Legrand/ABB/C&S
S & F in replacement of u/s timer panel with new street light timer panel suitable for single phase supply including astronomical digital timer, contactor single phase, MCB SPN 40 amos for incomer and outgoing for overload and short circuit protection, 40 Amp, 240 Volt complete all as per Havells Cat No. IHXSS0312A or eqivalent model in Legrand / C&S
S & F in replacement of u/s timer panel with new street light timer panel suitable for three phase supply including astronomical digital timer, contactor three phase, MCB TPN 63 amos for incomer and outgoing for overload and short circuit protection, 63 Amp, 440 Volt complete all as per Havells Cat No. IHXTS0912A or eqivalent model in Legrand / C&S.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 3.0 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified.
Excavation in trenches/post holes in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed.
Supply and laying river sand for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed. (Note: Thickness after punning shall be measured for payment)
Supply and laying brick protection cable cover using sub class ‘B’ bricks laid flat adjacent to each other across the length of cable laid dry complete all as specified & directed by Engr-in-charge.
M&L for 50 mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors.
M&L for 40 mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors.
M&L for 32 mm bore GI pipe light grade for cable protection ISI marked with all fittings and fixed complete to walls and ceilings or laid in floors.
M & L in replacement of damaged steel/PCC pole with new steel tubular poles in true vertical (or to be planted as strut) complete with cast iron base plate 6mm thick 300x300mm, final taper, plug, bolts, nuts & washers as specified type 410 SP-31 (9.0 mtr long) confirming to IS-2713 Part II type including re-fixing of removed accessories such as ACSR/AAC conductor, cables, street light fittings, clamps, nuts & bolts etc including painting with one coat of red oxide primer and two coats of silver aluminum paint for exposed surface and two coat of black bituminous paint for portion embedded in concrete complete all as specified and directed by Engr-in-charge. Note: - Excavation, MS work and PCC work will be measured and paid separately.
Material and labour for plain cement concrete (1:4:8) D2 type using 40 mm graded course aggregate for foundation etc.
Material and labour for plain cement concrete (1:3:6) C1 type using 20 mm graded course aggregate for coping etc.
Material and labour for plain cement concrete (1:2:4) B1 type using 20 mm graded course aggregate for coping etc.
S & F in repair of u/s timer switch with new Alpha Rex3, D22 Astro 1 channels astronomical digital timer switches including necessary connection complete all as specified & directed. Make : Legrand/Havells/ABB
S&F in repair power Contactor 3 Phase with AC coil 220 volts, 32 Amp, CN432 T01 type including making all connections complete all as per Havells cat No IHPAA018201* including Auxilary Contact side Block, Frame size-2 as per Havell Cat No ISPNASM611 or any equivalent model in Legrand / C&S.
Supplying, Laying, Jointing, testing and commissioning cable XLPE insulated armoured LT 1100 grade heavy duty with Stranded aluminum conductor through pipes in ducts, poles/ trenches including fixing of aluminum lugs, making good to disturbed surface etc for the following cross sectional area, complete the following as specified and directed :- (Note : Excavation and earth work shall be measured and paid separately)
2 Core 10 Sqmm
2 Core 16 Sqmm
4 core 10 Sqmm
4 Core 16 Sqmm
4 Core 25 Sqmm
3.5 core 35 Sqmm.
3.5 core 70 Sqmm.
M & L for Horizontal Boring of holes under road, pavement, hard standing by trenchless technology using GI Pipe of required dia and necessary machine suitable for 0.4 mpa working pressure. Note :- GI pipe medium / Light grade will be measeured and paid separately under respected item.
Supply only PVC electric cable with insulated aluminium conductor (stranded) with inner sheathing of PVC tape and overall PVC sheathed 1100 volts grade, heavy duty, 16 sqmm twin core, weather proof flat with accessories, complete all as specified and directed.
All as per Item no-44 above but of size 10 Sqmm two core.
All as per Item no-44 above but of size 06 Sqmm two core.
All as per Item no-44 above but of size 04 Sqmm two core.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm SDR-21 of 4kgf/cmsq with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified.
Supply, Install and testing on completion maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron, UL listed, CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 50kg/pit(resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7.The above arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 240 x 200mm) and FRLS insulated copper conductor of size 6 sqmm, single core cable drawn through and including medium grade rigid PVC conduit of suitable dia upto 7 mtr incl cutting and chases on wall / floor and making good using PCC work complete all as specified and directed. Note: If the test results are not satisfactory, the earthing shall be redone without any extra cost.
M&L for laying GI tubing light grade 80 mm dia with all fittings for cable protection including GI clamps nut bolts and washer etc all as specified.
M&L cutting PCC/floor/road and taking out cable and making good with PCC including material as per existing after laying of pipe for cable protection complete all as specified and directed at site of trench not more than 0.30 x 0.30m, complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for ducting and for finding fault of the cable in LT underground cable and returning filling (including reusing old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed Note: The excavation shall only be measured for payment.
Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7.The bove arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 40 200mm) complete, using GI earth Strip 25 x 4 mm connected to earth rod at one end by means of bolts, nuts, check nuts and washers and connected to metallic bodies of HT/LT all as specified and directed. Note :- On testing after completion of job, if desired earth resistance (i.e.resistivity is less than 0.12 Ohm meter) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7.The bove arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 40 200mm) complete, using copper wire 6.0 sqmm dia connected to earth rod at one end by means of bolts, nuts, check nuts and washers and connected to metallic bodies of LT poles all as specified and directed. Note :- On testing after completion of job, if desired earth resistance (i.e.resistivity is less than 0.12 Ohm meter) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
Taking down defective 25/36/40/45/60/250 Watt LED light fitting/SV/MH fittings, street light fitting mounted on pole/bldg on bracket disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and including trimming of branch if obstacle for lights to illuminate the area and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge. (Note- If any street light/ Flood light found un serviceable the same shall be replaced by contractor and fitting shall be mesured under supply only item )
Taking down defective 90/120 Watt led fitting mounted on 11 mtr long Semi high mast consisting of LED flood light fittings (Approx 4 to 6 Nos), street light fitting, mounted on 11/13mtr long high mast pole on bracket/ round ring, disconnecting, testing all components, dismantling of defective components such as driver of LEDs and cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge at site. (Note- If any street light/ Flood light found un serviceable the same shall be replaced by contractor and fitting shall be mesured under supply only item )
Taking down defective 250/400 Watt LED light fitting/SV/MH light fittings, High mast light fitting through motorised /manual system, mounted on 21 mtr long high mast pole on bracket/ round ring, disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing new PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge at site.(Note- If any street light/ Flood light found un serviceable the same shall be replaced by contractor and fitting shall be mesured under supply only item )
Supply only LED flood light 120 Watt 230 Volt AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply only LED flood light 210 Watt 230 Volt AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply only LED flood light 100 Watt 230 Volt AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F in replacement of Gate lights/post top light with 20 Watt LED light as light source, IP-65, made of spun aluminium land scape luminaire suitable for fixing on 40/50 mm GI pipe on the gate post including connection with all necessary accesssories complete all as specified and directed by Engr-In-Charge.
S&F in replacement of glow sign board box type of size 100 cm x 200cm made of flexy cover in blue and maroon bordering colour all around the flex board in rectangular form, blue background with MES logo on the centre with the stencil of word, font size as directed by Engr-in-Charge. One side of the board will display and the other side is made of GI Sheet with MS angle frame not less than 40x40x6mm, 02 x LED tube light fittings complete including connecting up with twin core twisted flexible copper conductor cable with suitable size and necessary items for fixing on roof of Pump House & Power House, with all grouting and PCC work complete all as specified and as directed.
M&L for bracket made of GI light grade pipe 1.2 Mtr long of size 40 mm bore bend to shape as per site requirement fixed to pole with FI 40mm x 5mm clamps -02Nos, bolts, Nuts, washers including painting two coats of aluminium paint over a coat of primer all as specified and directed by E-I-C
Supply and fix in replacement of GI tubing medium grade 40 mm dia ring with cap of pole including welding of flat iron 40mm x 5mm thick -04Nos including holes for suitable fixing of flood lights and painted with one coat of red oxide and two coats of synthetic enamel paint with clamps, bolts, nuts and whashers for fixing on poles, complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, complete all as specified and directed.
M & L in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 Sqmm 2/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut ,bolts and including provn for fixing 01 no of single pole MCBs 6-32 amps,10KA and MCB TPN 6-32 amps, 10 KA, ‘B’ series = 01 No inside the box complete all as specified and directed. Make :- Sintex/Hensel /standard or equivalent.
S&F in repair Astronomical+Digital Time switch model Havells : HSN code :9107, Cat Part No.DHTQB01016 or equivalent in Phillips/CG/L&T
S&F in repair nature time switch single phase model swadeep -02 sensor only along with switching timer complete all as specified and directed by Engineer-in-Charge.
S&F in repair Street light timer panel, single phase with maximum load of 12 Kw with inbuilt astronomical time switch, 65 Amp contactor, 63 Amp SPN confirming to IS/IEC/604947-4-1, FRLS internal wiring, with IP 54 protection and inbuilt short circuit protection. All as specified and directed at site. Make : Havells, HSN Code 8537, Cat Part No IHXSS0312A or equivalent in CG, C&S, Phillips
S&F in repair contactor 32 Amp 3 phase, 415 volts as per IS 13947-4-1 ,suitable for nature time switch model swadeep -02 complete all as specified and directed by Engineer-in-Charge. Make :- BCH or equivalent in L&T, CG , Siemens.
S&F in repair LED driver 75 watt, single Phase , 240 V , for LED street light fitting complete all as specified and directed by Engineer-in-Charge. Make : Crompton, Havells, Phillips
S&F in repair LED driver 60 watt, single Phase , 240 V , for LED street light fitting complete all as specified and directed by Engineer-in-Charge. Make : Crompton, Havells, Phillips
S&F in repair LED driver 45 watt, single Phase , 240 V , for LED street light fitting complete all as specified and directed by Engineer-in-Charge. Make : Crompton, Havells, Phillips
S&F in repair surge protection device compatible with outdoor LED fixture, make : Crompton, Cat part No.SRPS-HP-5K-440 or equivalent in C&S, Havells, Phillipsfor LED light fitting with rated power up to 75W complete all as specified
Labour only for stringing, tightening, fixing and connecting ACSR conductor and GI Wire of existing LT overhead line any size any type, between pole to pole, approximate span length 40 to 50m, complete the following all as specified and directed : -
2 Wire with/Without GI Wire.
5 Wire With GI Wire.
6 Wire With GI Wire.
M&L in repair for LT line PVC Spacers spiral type for the following :-
Spacer for two wire
Spacer for three wire
Spacer for four wire
Dismentling of ACSR conductor, service feeder or distribution spans complete all as directed.
Supplying, Stringing, Tightening, Fixing & connecting ACSR conductor of any size for over Head LT/HT Line including aluminium binding wire or aluminium tape of suitable type clamps/connector or other jointing material complete all as specified and directed by EIC.
M&L for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint all as specified and directed by EIC.
M&L for stringing in replacement of steel wire 4 mm dia 8 SwG as continuous earth wire and grading incl cradal hexagonal binding properly with channel/Angles etc complete all as specified
S&F Anticlimbing devices. Comprising of 2.24mm dia galvanised steel 2 stranded barbed wire with 2.0 mm dia barbs wrapped spirally round poles to a length of 0.5 to 1.0 mtr clamped and properly screwed all as directed by Engr-in-Charge
Supply and fixing in repairs stay assembly for HT/LT Pole comprising of 7/3.15mm galvanized steel stranded stay wire of required length fixed to pole with and including clamps fabricated out of MS Clamps 50 x 6 mm flat iron including nuts, bolts and washers, MS galvanized stay bow 14mm dia 400mm long galvanized steel stay rod 16mm dia, 1800mm long with ratchet type nuts & bolts and stay plate, galvanized thimble 02 Nos, loop insulators 65mm x90mm clearance dia of hole 16mm all as specified and shown in electrical plate No. 1 of MES SSR including all necessary excavation and earth work, PCC (1:3:6) type C-2 using 40mm graded stone aggregate ,embedded block and disposal of surplus soil to a distance not exceeding 50mtr complete all as specified and directed by EIC.
Repairs to existing stay assembly including tightening of stay wire, , shifting of clamps fixed to pole or by repairing to PCC coping by breaking and making new coping with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and directed at site .
S&F in replacement of 1100 volts grade heavy duty cable PVC insulated alumium conductor multistranded served with innter sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulated hangers not more then 1 meter a part including 4 mm dia GK suspension wire one twin core cable flat or circular 6 Sqmm 2 core all as specified and directed. Make Poly cab, Havells
Ditto all as per Item No 88 above but 10 Sqmm 2 core, complete all as specified and directed.
Supply only MCCB 4 pole, 415 volts 400 amp 36 KA with thermal setting (Adjustable type) including necessary cable connection with lugs etc complete all as specified and directed.
Ditto all as per Item No 90 above but 250 Amp, 36 KA complete all as specified and directed.
Ditto all as per Item No 90 above but 200 Amp, 36 KA complete all as specified and directed.
Ditto all as per Item No 90 above but 160 Amp 25 KA, complete all as specified and directed.
Ditto all as per Item No 90 above but 100 Amp 25 KA, complete all as specified and directed.
Ditto all as per Item No 90 above but 63 Amp 25 KA, complete all as specified and directed.
M&L for MCB single pole, 6 to 32 Amp 240 volt B curve 10 KA, IP 20 suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed.
M&L for MCB single SPN, 32 Amp 240 volt C curve 10 KA, IP 20 suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed
M&L for MCB single SPN, 40/63 Amp 240 volt C curve 10 KA, IP 20 suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed
M&L for MCB single TPN, 63 Amp 415 volt C curve 10 KA, IP 20 suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed
M&L for repairing LT feeder box/ panel and their doors, inner compartments etc by denting/ welding where required and Cleaning, removing old paint by paint remover/scrappers for any number of coats, any width or girth and applying two coats of synthetic enamel paint by spray painting,inside and outside of panels(second coat shall be applied at the interval of one day) of the approved colour, complete all as specified and directed.
M&L for pin insulator porcelain type vitreous white brown including one galvanized mild steel spindle two galvanize iron washers and one galvanized iron nut 100 mm height, 65mm dia for 1100 V grade, complete all as specified and directed.
M&L for shackle type porcelain vitreous white, brown including one galvanized mild steel straps, washers, bolts and nuts 100 mm height, 115 mm dia, section of strap 31 x 5 mm for 1100 V grade, complete all as specified and directed.
M&L for Painting of single LT steel tubular pole including. cleaning and scrapping the old surface and then applying two coat of aluminium synthetic enamel paint over a coat of red oxide primer on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc. and including painting of pole/ structure ith two coat of synthetic black & yellow enamel paint strip 300 mm wide alternative from bottom to upward of LT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete the following as specified and directed :- Notes: - (i) Pole will be cleaned with steel brush to remove old unserviceable paint or scrapped complete surface. (ii) All poles will be numbered all as directed at site. (iii) If painting of poles not properly and not satisfied by JE/Engr-in-charge shall not be paid to contractor or otherwise repaint without extra cost.
M & L for prunning of tree branches of any sizes and dia, not less than 2 Mtr around the LT /HT OH line which obstructing the power supply/ maintenance of electric supply as well as illumination in area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area and testing of line, complete all as specified and directed. Note : (i) Span length is aproximate 40 to 50m. (ii) Rate quoted are inclusive of repair to damage work in item.
Material and labour for spreading stone aggregate of size 40mm at 11 KV sub station/Transformer/panel board/two pole/four pole structure area, complete all as specified and directed.
Supply only PVC insulated multistrand Copper Cable 3 core size 1.5 sq mm for bldg/security light fittings connections.
Supply only PVC insulated multistrand Copper Cable 3 core size 2.5 sq mm for bldg/security light fittings connections.
Supply only Insulation electric tape roll 20 mm 25 mtr long complete.
Disconnecting carefully old unserviceable Ammeter from panel board and Supply & Fix of new 96 mm size square digital type ammeter of range 0-100 Ampere with set of CTs of suitable rating complete all as specified and directed. Make : L&T cat pt no WL131010OOOO or Equivalent in AE/Schiender.
Disconnecting carefully old unserviceable Voltmeter from panel board and Supply & Fix of new 96 mm size square digital type Voltmeter of range 0-500 Volt complete all as specified and directed Make : L&T cat pt no WL132010OOOO or Equivalent in AE/Schiender.
Supply & Fix in replacement of LED type RYB indicating lamps on existing panel board including necessary fixing and connecting arrangement complete all as specified and directed
Supply and Replacement of Bamboo ladder 26 steps complete all as specified and directed.
M&L for painting of installations boards/insign as in navy blue background colour and letters in white colour, including making the surfaces clean for painting complete all as specified and directed. Note: The area of each board shall be more than 5.0 Sq.M
Supply & Fix in replacement of Phase sequence corrector suitable for 50 HP VT pump starter alongwith protection from over voltage and under voltage, protection from phase loss, protection from phase reversal and correction of sequence, LED indication RYB for input phase sequence normal and input phase sequence reverse, free standing/ wall mountable power coated cabinet including all assessories complete all as specified and directed.
M/S ROORKEE ENGINEERING
AMAR NATH SHARMA
Shikha Enterprises
KRISHANA ELECTRIC WORKS
Ramesh Traders Govt Contractors & General OrderSuppliers
Pradeep Bros
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .