Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC L-1 Agency |
| 2 | L2₹1.7 Cr+₹20.8 L (14.2%)Rejected-Finance | ₹1.7 Cr+₹20.8 L (14.2%) | L2 | Rejected-Finance HIGHLY QUOTED |
| 3 | L3₹1.7 Cr+₹25.1 L (17.0%)Rejected-Finance 63 SECTOR 4 R FARIDABAD HARYANA 121004 | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹1.7 Cr+₹25.1 L (17.0%) | L3 | Rejected-Finance HIGHLY QUOTED |
| 4 | L4₹1.9 Cr+₹41.2 L (28.0%)Rejected-Finance | ₹1.9 Cr+₹41.2 L (28.0%) | L4 | Rejected-Finance HIGHLY QUOTED |
| 5 | L5₹2.1 Cr+₹60.9 L (41.4%)Rejected-Finance 21 PROMISE APARTMENT F BLOCK VIKASPURI NEW DELHI 110018 | WEST | DELHI | 110018 | ₹2.1 Cr+₹60.9 L (41.4%) | L5 | Rejected-Finance HIGHLY QUOTED |
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
15 Jan 2018, 6:00 pmClosed
AGM(ENGG-CIVIL)-I
Asst. Gen. Manager (Engg-Civil), Civil Project Division-I, Airports Authority of India, Dabolim Airport, Goa-403801
CIVIL AND ELECTRICAL DETAILS
2017_AAI_5135_1
aai/goa/engg/civil/nitb/office
Open Tender
Construction Works
Item Rate
120 days
GOA AIRPORT
PLEASE REFER TENDER DOCUMENT
7 documents required · 7 mandatory
₹1,120
AIRPORTS AUTHORITY OF INDIA
₹3.8 L
30 Jun 2021
28 Dec 2017
19 Jan 2018
29 Dec 2017
15 Jan 2018
29 Dec 2017
29 Dec 2017 - 5 Jan 2018
Amount
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. a)Hot finished seamless type tubes
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. A) On steel work
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Providing & fixing in position 4mm thk. Aluminium composite panels in external face, column/wall cladding and canopy ceiling of approved make conforming to ASTM standard /specifications comprising polyethylene core sandwiched between two skins of 0.50mm thick special alloyed aluminium sheet to have overall thickness of 4mm with exterior coating of PVDF Paint. Fixing of surface cladding to masonry/ concrete faces/steel structure as called for, including appropriate and adequate framework of aluminium tubular sections 50x25x3mm and 25x38x3mm to fix the composite panel to the frame, straight/slope and curvilinear profile and shapes including all accessories and all incidental work. The cladding shall be done in accordance with the drawings, fixed to sides and faces of columns /piers, to sills and soffits of window opening, returned over coping, to R.C.C/ structural steel system, etc, to line and level. The joints shall be properly sealed with approved Silicon sealant to make the joints watertight and weather proof including, fixing over aluminium frame using mechanical fasteners such as Aluminium cleats and Stainless Steel fasteners. Specially designed frame work with vertical and horizontal members of extruded aluminium section which shall be made of alloy 6063 T6, as approved by the Engineer-in-charge (as per drawing enclosed)The work shall be complete as per specification and directions of Engineer-in -Charge.
Supplying and installation of 12 mm thick frameless toughened glass single swing door (1.1 m x 2.49 m) of Dorma-Germany / Linox-Australia / Geze-Germany or approved equivalent. All edges of the glass is to be machine polished and sides also to be toughened. The work includes cost of all cut outs/holes. The doors to be hung on Dorma heavy floor spring BTS 84 - DORMA / FS 004 - Linox / TS 500 EN3 of Geze or approved equivalent . The patch fittings consisting of all required patch fittings for door with side and upper panels,upper and bootom patches,floor lock with cylinder and strike plate and pull handle of size 350mmX22mm complete as per direction of Engineer-In-Charge.
Supplying and installation of 12 mm thick clear toughened glass with required cutouts / holes and Dorma or equivalent Wall connecting Profile base rail with fixing holes incl. clamping parts with screws and gasket for 12 mm glass with cover profile on both sides, (profile fixed on floor & ceiling, sides are frameless)
Removal of fixed glass partition and glass doors from existing location in NITB and refixing the same to desired location as directed and making good the floor etc. complete to the satisfaction of Engineer-in-Charge.
Removal of existing Curtain wall glazing system upto a height of 5 metres and refixing the same to desired location as directed and making good the floor etc. complete to the satisfaction of Engineer-in-Charge.
Dismantling semi unitized aluminium structural glazing partitions including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-Charge.
Fixing of available Semi unitized Aluminium structural glazing system with pasting of glass on frames using both side adhesive tape & structural silicone, the glass panels shall be mechanically supported to the aluminium main frame of mullion size 65x150 mm having wt. 3.972 kg/m. & Transom size 65x132 mm having wt. 2.3 kg/m., with all standard accessories and hardware of approved make. The anchoring/ bracing of the structural systems to the RCC slab/ beams/ columns shall be done with 5mm thick M.S. galvanized bracket & including providing Teflon shims of various thickness to adjust the beam level / line variations fixed with SS 316 grade dash fasteners of 12mm dia. and depth of 50-80mm in the concrete and to withstand the dead load of the structural curtain wall as well as stresses due to wind pressure etc. All screws, washers used shall be of stainless steel of 304 grade and through bolts, nuts & Anchors used shall be of stainless steel of 316 grade etc. complete as per directions of Engineer-in- Charge.(Glass to be paid separately )
Steel work in built up sections, tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. ( Rate to be quoted for labour cost & materials shall be supplied by department received from dismantling of steel structure )
Providing and fixing 12mm thick White/Coloured Acrylic solid surface of Corian/Neonnex make and 18 mm marine Plyboard for counter purpose with all required accessories, adhesive, polishing & buffing with complete finishing work as per diection and to the satisfaction of Engineer-in-Charge.
Removing and refixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 500 m lead.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. a) In cement mortar
Providing and fixing 8 mm thick multi coloured lacquered glass over SS pipe framework with finishing complete as per direction and to the satisfaction of Engineer-in-Charge. (SS pipe framework shall be paid separately)
Providing and laying mirror finished 18 to 20mm thick finished superior granite stone flooring, machine cut in required size, approved shade, colour and texture laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with white cement slurry mixed with matching pigment, including rubbing and curing etc. complete at all levels. (Sample of granite stone shall be approved by Engineer-in-Charge) (a) Machine cut ,Pre- polished Granite 18-20 mm thick
Providing and placing in position Check in Counter of size 900 x 825 x 1150 mm consisting of the following: 1. All vertical and horizontal sides shall be provided with 18mm thick ISI water proof marine plywood (century, greenply, orchid or equivalent) conforming to relevant IS standards and fixed to the Stainless Steel frame work. 2. All the Stainless Steel frame work shall be made of 16 Gauge, 304 Grade Stainless Steel pipes including welding grinding and buffing the joint etc. (i) 50.6mm dia SS pipes (Glossy/Matt finish at exposed surfaces) in all four corners connected with 20mm square SS pipes at top and bottom at three sides and top at back side. (ii) Counter top at 1150mm level, all-round frame work and vertical support with 20mm square SS pipes. (iii) 25.3mm dia SS pipes railing at bottom at front side of the counter (Glossy/Matt finish). 3. All outside vertical exposed surfaces of counter finished with 12mm thick acrylic polymer solid surface material. 4. Passenger counter top finished with acrylic polymer solid surface material of 12mm thick at top and 6mm thick at bottom. 5. Passenger counter top vertical finished with acrylic polymer solid surface material of 12mm thick at outside and 6mm thick at inside. 6. Staff counter top finished with acrylic polymer solid surface material of 12mm thick at top. 7. All the exposed edged of plywood at exterior sides to be covered with acrylic polymer solid surface material 9. Acrylic Polymer Surface material should be the make of E.I. Dupont (P) Ltd. (Cocoa Brown – F Range, White Jasmine – C range) or Samsung Staron (Sanded Icicle, SI – 414 for white, Aspen Dark, Ad 621 – for brown) or hanex (S 002 for white, Gangeesbank, T 043 – for brown) 10. All other interior exposed surfaces of counter finished with 1.5mm thick lamination of approved brand and colour. 11. Two numbers of drawers with slider including providing level adjuster, making necessary cut outs, adhesives, accessories etc. all complete as per the enclosed drawings and the direction of Engineer-in-Charge. 12. The work to be executed as per relevant drawing SK-77 attached at Page no. 154. The quoted rate includes the cost of all labour,material involved, fabrication, transportation, placing in position, fixing etc. complete.
Repairing and refixing of existing aluminum partitions, doors and windows of all sizes including opening the section and refixing the sections with necessary screws etc., complete as per the directions of EIC.
Providing assistance on structural issues while carrying out modification works to meet the desired requirements. (This item shall be executed with the prior approval of Engineer In-charge or Project In-charge.)
Providing assistance on architectural issues while carrying out modification works to meet the desired requirements. (This item shall be executed with the prior approval of Engineer In-charge or Project In-charge.)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modularswitch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group A )
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent/LED type fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.( Fittings will be provided by AAI )
Installation, testing and commissioning of ceiling fan/Wall Mounting Fan , ncluding wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 3 run of cable
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) (a) 8 way (4 + 24), Double door.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40Amps
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 Amps
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm
Supplying and fixing Single Phase Kwh meter with LCD display 5-30A range with Box Make L&T Cat No - WM101BC5DLOBOX
Supply of Wall Mounting Fans 400mm Sweep suitable for operating on 230V , 50 Hz AC Supply as per approved Make of AAI
Supply of Pedestal Fans 400mm Sweep suitable for operating on 230V , 50 Hz AC Supply as per approved Make of AAI
Supply and fixing of Modular Socket with Box , cover Plates etc Suitable for UTP 4 pair CAT 6 LAN Cable RJ Connector
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 4 Module (125 mmX75 mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 6 pin 15/16 A socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Classion Projects (I) Pvt. Ltd.
BR Power Control and Automation Services
DECOR INDIA
SAMTA INTERIORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .