Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹8.3 L+₹1.7 L (25.9%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
24 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT
CERTAIN REPAIR/REPLACEMENT TO SERVO VOLTAGE STABLIZER, UPS CONTROL GEARS FIRE ALARM SYSTEM AND ALLIED WORKS FOR EXTERNAL ELECTRIC SUPPLY AT AF STN BKT
2022_MES_548614_3
8634/BKT/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BKT
₹12,000
Yes
6 Feb 2023
3 Nov 2022
26 Nov 2022
3 Nov 2022
24 Nov 2022
12 Nov 2022
Amount
Dismantling of upper cover of servo Voltage stabilizer of capacity 315 KVA after disconnecting electrical connections for overall servicing, cleaning of dust and replacement of complete old wiring with FRLS copper conductor of suitable size in proper layout and tight with micro processor based panel,Potentiometer, RC network with box, 6/12 pin connector, indicator, main transformers and dimmerstat (Variac) three phase or any other parts and deposited to MES store yard and fixing complete including testing all as specified and directed.(Parts to be replaced shall be measured and paid separately except wiring) overall servicing , cleaning of dust and replacement with new complete wiring with FRLS copper conductor of suitable size in proper layout and tight with tie, all as specified and directed by Engg-in-charge . (Note : New parts will be measured and paid separately under relevant items except replacement of old wiring which is deemed to be included in the quoted rate of item)
Ditto all as per item ser No 1 here-in-above but of capacity 75 KVA
Ditto all as per item ser No 1 here-in-above but of capacity 30 KVA
Ditto all as per item ser No 1 here-in-above but of capacity 10 KVA
Supply & fixing main Transformers suitable for servo voltage stabilizers of capacity 10 KVA complete. Make- Vintek Electronics/volina
Supply & fixing main Transformers suitable for servo voltage stabilizers of capacity 30 KVA complete. Make- Vintec/ ITE Gurgaun/ Powerworks/M/S Sai electricals/volina
Supply & fixing Transformers suitable for servo voltage stabilizers of capacity 75 KVA complete. Make- Vintec/ ITE Gurgaun/ Powerworks/M/S Sai electricals/volina
Supply and fixing dimmerstate (Variac) suitable for servo voltage stabilizers of capacity 10 KVA complete. Make- Vintec/ ITE Gurgaun/ Powerworks/M/S Sai electricals/volina
Supply and fixing Dimmerstate (Variac) suitable for servo voltage stabilizers of capacity 30 KVA complete.Make- Vintec/ ITE Gurgaun/ Powerworks/M/S Sai electricals/volino
Supply and fixing Dimmerstate (Variac) suitable for servo voltage stabilizers of capacity 75 KVA complete. Make- Vintec/ ITE Gurgaun/ Powerworks/M/S Sai electricals/volino
Supply and fixing of Electronic sensing card ( PCB) suitable for servo voltage stabilizers. Make - Vintek Electronics/volina
Supply & fixing servo motor 3 Kg Torque complete suitable for 10 KVA to 315 KVA servo voltage stablizer . Make Vintec Electronic/Volin
Supply & fixing of Electronic Sensing transformer. Make vintec electronic/volina
Supply & fixing of Potentiometer suitable for servo voltage stabilizer. Make Vintec Electronic/volina
Supply & fixing voltmeter 0-300V suitable for servo voltage stabilizer. Make AE/L&T
Supply & fixing RC Network suitable for servo voltage stablizer of capacity 10 KVA to 200 KVA complete all as specified and as directed by Engr-in-charge. Make Vintec electronic/volina
Supply & fixing of Box for RC network complete all as specified and as directed by Engr-in-charge. Make Vintec electronic/volina
Supply and fixing connector 6/12 pin as required at site as per capacity of voltage stablilizer complete all as specified. Make Vintec electronic/volina
Supply & fixing Carbon bush of suitable size upto the capacity of 10 KVA complete all as specified and as directed by Engr-in-charge. Make:- Vintec electronic/volina
Supply & fixing Carbon bush of suitable size upto capacity of 100 KVA to 300 KVA complete all as specified and as directed. Make:- Vintec electronic/volina
Supply & fixing Indicators of RYB of suitable size upto the capacity of 10 KVA to 315 KVA voltage stabilizer complete all as directed. Make:- Vintec electronic/volina
M&L for locating the fault in fire alarm control panel of capacity 4 Zone to 8 Zone including checking and rectification of defects, tighting loose connection of control panel, accessories etc including testing,replacement of any unserviceable parts to keep the lift functional and making the free movement of entire unit as directed by Engr-in-Charge. Note : (a) Replacement of any unserviceable parts will be measured and paid separatly under relevant items
Supply and filling new Oil brought in sealed barrel of capacity 200 Litre having strength of 50 KV at 2.5 mm gap complete all as specified and directed by Engineer-in-Charge. Make : Power oil / SAVITA / Electrol.
M&L for locating the fault in E.O.T Crane of any capacity upto 10 Ton including rectification of minor defects such as tightening of nut and bolts, checking and rectifying loose connection of control panel, accessories and current collectors replacing of fuse wire, etc to keep the crane functional and making the free movement of entire unit as directed by Engr-in-Charge. Note : (a) Contractor will send their tech qualified rep for taking over daily crane complaint from user end and to rectify the same including open the separate register for complaints and signed by concerned user rep , MES rep after rectifying the complaint and submit the same before claiming the Payment of item. (b) Each job comprises of one crane.
Servicing of EOT crane uptp 10 Ton and comprising of the following:- (a)Greasing/oiling of required part ie shaft, coupling, rope drum shaft bearing etc. (b)Checking & testing/adjustment of brakes for of all the motions ©Checking & tightening of coupling bolts, motor foundation bolt etc. (d)Checking the wiring connections in control panel and other accessories and to ensure that no loose/naked connection exist. (e)Checking of gear oil in gear boxes and topping them if necessary . (f)Checking of transformer oil in electro hydraulic thruster unit & topping up if necessary (g) Cleaning of Bridge girder including plate form, cabin, panel, complete. Note:- Each job shall mean each crane.
Supply and fixing smoke dedector sensor ISI marked compelete as all directed.
Repairing of unserviceable out door siren hooter from emergency fire alarm authorised dealer workshop including replacement of spare parts for making fully functional of siren hooter at site.
Supply and fixing Loop card with 254 device of both detectors and modules in a single line circute, SLC supports both class A and Class B wiring complete as all directed.
Supply and fixing addressable manual call point, resettable type with back box with binary coded address setting with status LED for 360 degree visibility - IP :50 ratinmg complete.
Dismantaling of all incoming and outgoing Electric connection from existing Unserviceable 3 Phase electric Siren and Supply and fixing new Three phase 440 Volts 2800 RPM Motrised Siren 5 KM audiable range horizontal type complete with all mounting acessories all as specified and as directed
S&F flexible copper cable 6 Sqmm 4 Core multi stranded complete.
S&F 3 HP motor direct on line with motor starter for suitable operation of Siren including all fixing acessories complete all as specified and directed by Engr-in-Charge. Make :- L&T/Havells/Legrand
Supply, installation testing and replacement of maintenance free battery of capacity 12 Volt 120 AH suitable for 100 KVA UPS with brass/copper terminal and copper cable of size not less than 25 Sqmm single core for interconnection battery complete all as specified and directed.
Supply ,installation, testing and replacement of maintenance free battery of capacity 12 Volt 30 AH suitable for 10 KVA UPS with brass/copper terminal and copper cable of size not less than 16 Sqmm single core for interconnection of battery complete all as specified and directed.
Dismantling and taking down existing unservicable UPS of capacity upto 100 KVA checking the seviceability of spare parts, wiring etc, repairing of charger card, charger firing card and replacement of unserviceable parts with new parts, reassembling including new wiring,testing , commissioning of UPS with rated load complete all as specified and directed. Note : (Items required for replacement of worn out parts will be measured and paid separately under respective item but fixing of the same shall be deemed to be included in quoted rates)
Supply only driver card 8400-509C suitable for UPS for item No 33 here in before complete all as specified and directed
Supply only inverter control card 8400/181 suitable for UPS for item No 35 here in before complete all as specified and directed
Supply only static driver card 8400/505 suitable for UPS for item No 35 here in before complete all as specified and directed
M & L for checking the serviceability and Servicing of existing UPS of capacity upto 100 KVA including testing at rated load for all theree phase all as specified and directed by Engr-in-charge.
Earthing complete with copper plate 60×60cm ×3.15mm thick electrode , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. Note:- (i) The rate quoted shall be also deemed to include the cost of earth test point nd earth strip & protection pipe upto 7.5m beyond the earth plate electrode and the earth resistance of the whote system shall be as near as possible to O but shall not in any case exceed one ohm. (ii) Any joints in earth lead from electrode to test point shall not be allowed/permitted)
M&L for earthing complete with copper plate 60×60cm ×3.15mm thick burried directly in ground earth pit n. less than 3 Mtr deep below the ground level with top edge of the plate n. less than 1.5m below ground level and filling with cotton soil of volume 0.5 CUM brought from outside and laying Magnesium sulphate of 100 kg, salt of 100 kg and charcol of 100 kg and connected to 20×3mm copper strip by means of bolts,nuts,checks nuts and washers of galvanised steel including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and chamber RCC cover and light grade GI pipe 50 mm dia of required length for protection of copper strip and water funnel and wire mesh with GI pipe medium grade 20 mm dia etc complete all as per electrical plate No. 3 of SSR Part-I and as directed including connections and testing on completion. Note:- (i) The rate quoted shall be also deemed to include the cost of earth test point nd earth strip & protection pipe upto 7.5m beyond the earth plate electrode and the earth resistance of the whote system shall be as near as possible to O but shall not in any case exceed one ohm. (ii) Any joints in earth lead from electrode to test point shall not be allowed/permitted)
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required but 20x 3 mm copper strip all as directed
Unnati Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .