| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹21.5 L+₹71,402.75 (3.43%)Rejected-AOC H NO 12 ADRASH SAINIK ENCLAVE HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹22.1 L+₹1.3 L (6.18%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher quoting | |
| 4 | L4₹22.1 L+₹1.3 L (6.34%)Rejected-AOC 11 71 KAVERI PATH MANSAROVAR JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | L4 | Rejected-AOC Rejected being higher quoting | |
| 5 | L5₹24.5 L+₹3.7 L (17.6%)Rejected-AOC 1542 URBAN ESTATE II HISAR 125 005 HARYANA | HISAR | HARYANA | 125005 | L5 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹25.4 L
EMD Value
₹50,800
Closing Date
11 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Hisar
Garrison Engineer Hisar Military Station Hisar - 125006
GE(H)-46/2020-21
2020_MES_397871_2
GE(H)-46/2020-21
Open Tender
Civil Works
Item Rate
180 days
Hisar Mil Stn
As per Tender documents
6 documents required · 6 mandatory
₹500
GE Hisar
₹50,800
Yes
22 Jan 2021
24 Dec 2020
13 Jan 2021
24 Dec 2020
11 Jan 2021
28 Dec 2020
60 days
Amount
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed.
Demolition of brick/stone masonry built in cement/lime mortar of any mix and stacking serviceable stones aside for reuse & removing unserviceable materials in low laying area, complete, all as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for in this Schedule all as specified & directed.
Demolition of cement concrete reinforced of any description and in any position complete all as specified and directed.
Demolition and breaking up drain pipes 150mm bore (Salt glazed stone ware, AC or Reinforced concrete/PVC) set in cement mortar complete all as specified.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises all as specified and directed .
Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc complete all as specified
Taking down chowkat or frame with shutters area not exc 1.5 Sqm each (without taking off the shutters from the frame) including cutting holes for hold fasts & making good complete all as specified.
Taking down chowkat or frame with shutters area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) including cutting holes for hold fasts & making good complete all as specified.
Surface dressing not exc 15cm deep in soft/loose soil complete all as specified.
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in soft/loose soilall as specified and directed.
Excavation over areas not exc 1.5m deep and getting out in soft/loose soil all as specified and as directed.
Excavating in trenches not exc 1.5 metre wide and exc 1.50 metre and not exc 3.00 m in depth for foundation or for shafts, walls, manholes, laying of cables, pipes etc not exc 10 Sqm on plan and getting out in any type of soil all as specified and directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil all as specified and directed.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface in soft/ loose soil all as specified.
Material and labour hardcore of broken bricks, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface all as directed.
M&L for PCC 1:7:12 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete all as specified.
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete all as specified.
M&L for PCC 1:3:6 type C0, using 12.5mm graded crushed stone aggregate as in filling up chowkat hollows and similar works as directed, complete, all as specified.
M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:6) complete all as specified & as directed. Note :- Reinforcement shall be measured and paid for separately.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified.
M&L cement concrete (1:3:6) type C1 using 20 mm graded stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement all as specified and directed Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified.
M&L reinforced cement concrete 1:2:4 type B1 (nominal mix) using 20mm graded stone aggregate in chajjas and the like all as specified and directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L reinforced cement concrete M-25 grade (Design mix) using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like all as specified and directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate in beams, cantilevers, bressummers, lintels over 1.5m span and the like all as specified and directed. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L formwork to flat surfaces of chajjas, chullah hoods, troughs and similar items including edges for rough finished surfaces all as specified and directed.
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete all as specified.
M&L formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete all as specified and directed.
M&L formwork to edges of concrete flats, roofs, floors etc not exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces all as specified and directed.
M&L 40mm thick PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in damp proof course on horizontal surface including necessary formwork applying evenly a coat of blown type bitumen at the rate of 1.50 Kg per sqm and blinding with clean dry sand @ 0.005 cum per sqm complete all as specified & as directed.
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.
M&L brick work with subclass 'B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified.
M&L brick work with subclass 'B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:3 complete all as specified.
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:3 complete all as specified.
M&L for brick work using old size flyash bricks as specified in clasue 6 of Particular specification, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.
Material and labour brick work with old size sub-class ‘B’ bricks, in one brick thick honey comb walling, built in cement mortar 1:3 complete all as specified.
Material and labour loose filling with broken bricks aggregates of gauge 40 to 80 mm in soakage pits, soakage wells all as specified and directed
Supply and fixing factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified & directed.
S & F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of Plain colour PVC Sheet & edges shall be painted to match with printed sheet, reinforced with MS square tube fixed in opening complete as per manufacturer's specifications etc complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded but wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F butt hinges of size 100mm medium weight, stainless steel ISI marked complete all as specified.
S & F 150mm long extruded aluminium alloy handles, fabricated type, anodised (ISI marked) complete all as specified.
S & F 200mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified.
S&F 250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified.
S&F 150mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door all as specified and directed.
S&F factory made pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, mild steel sheet of 1.25 mm thickness complete as specified & as directed. Note :- Rates quoted deemed to include S&F of hinges, lugs, lock strike plate.
S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple complete all as specified.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified.
S&F factory made box type Steel ventilators with top hund shutter incl hinges, steel peg stay complete all as specified & directed.
M&L for reinforcement TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified.
All as per serial item No. 53.00 here-in-before but 5 to 10mm dia in stirrups, spacers and binders.
All as per serial item No. 53.00 here-in-before but 6mm to 8mm dia.
S&F mild steel framed work using ERW or induction butt welded tubes conforming to I.S 1161-1979 Grade St-240 including necessary welding, bolting, special shaped washer, clamps, cleats etc. complete all as specified & as directed.
S&F mild steel framed work rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to grade Fe-410-W(GdeE-250) qualityB complete all as specified & as directed.
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding etc. conforming to Gde E-250 (Fe 410-W) quality `A’ all as specified and as directed.
S&F mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete, all as specified & directed.
S&F mild steel framed work such as Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Grade Fe 410 -W (GdeE- 250) quality A , complete, all as specified & directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cooler stand and similar work including welding conforming to Grade E-165 (Fe 290), complete, all as specified & directed.
S&F 1.25mm thick Plain, black mild steel sheeting in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) complete all as specified and directed.
S&F mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut not exc 10cm long, dia of neck exc 12mm but not exc 25mm complete all as specified & as directed.
Supply and fixing 6 mm thick asbestos cement, corrugated or semi corrugated sheets in roofs, walls etc and fixed with ‘L’ type or ‘J’ type or cranked hooks bolts complete all as specified.
M&L 6 mm thick asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheets fixed with ‘L’ type or J type or cranked hook bolt complete all as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or ‘L’ type or ‘J’ type or cranked hooks bolts complete all as specified & directed.
S&F GI strip snap grid size 605 x 605mm frame work for false ceiling including hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified. complete all as specified & directed.
S&F False ceiling with 9-10mm thick gypsum board, duly finished surface (thin PVC layer on gypsum board as per manufacturer's instruction), 600mm x 600mm in size and complete all as specified & as directed. Note : The GI snap grid frame work shall be measured & paid for separately
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified.
M&L for PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in levelling course 25mm thick finished fair & even complete all as specified & as directed.
M&L for machine cut Kota stone slab flooring 20 to 25mm thick laid over & including screed bed or bedding layer of 15mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified. Note : - Kota stone shall be of size 550mm x 550mm (minimum) when brought at site.
M&L for non skid ceramic jointless tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for non skid ceramic jointless tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for glazed ceramic jointless tiles (coloured) 300x250x7mm/450x300x7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for 50mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for Granite (of any type) tiles 18-20mm thick machine cut, as in floor, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over & including 20mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified & directed.
M&L for factory made 60mm thick machine pressed precast cement concrete interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & directed.
M&L for rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces of walls , finished even and smooth without using extra cement complete all as specified.
M & L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified.
M & L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement mixed with and including liquid water proofing compound @200 ML per 50 KG by weight of cement complete all as specified and directed.
Complete removal of existing treatment on walls (any numbers of layers) by scrapping with steel wire brushing or any other means, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. etc all as specified & as directed.
M&L for preparation of old plastered or unplastered surfaces of walls (any numbers of layers) by scrapping with steel wire brushing or any other means, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. etc and applying two coats of white wash complete all as specified & as directed.
M&L for preparation of newly plastered surfaces of walls & applying three coats of white wash complete all as specified.
M&L for preparation of old plastered or unplastered surfaces of walls by scrapping with steel wire brushing or any other means, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. etc and applying two coats of cement base paint of approved shade/tint all as specified & as directed.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint on walls all as specified & as directed.
S&F 3mm thick Polycarbonate sheet (transparent sheet) in square not exc 0.5 sqm in each pane fixed with oil putty and silicon gel with screws complete all as specified and as directed.
M&L for preparation of old surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer after complete removal of old paint complete all as specified.
M&L for preparation of old steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer after complete removal of paint complete all as specified.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified.
Material and labour for preparation of new steel surfaces (already applied with coat of primer) of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint of approved tint on existing primer complete all as specified.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing etc. and making good, cutting not exc 10 cm girth in brick walls all as specified and directed.
Taking up or down 15mm bore steel tubing and connection incl cleaning for refixing or removal to store all as specified and directed.
Taking up or down 20mm bore steel tubing and connection incl cleaning for refixing or removal to store all as specified and directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Fixing only GI water tubing 15 mm bore, medium grade, with & including supply & fixing all new fittings (ISI marked) complete fixed to walls and ceilings or laid in floors all as specified & as directed. Notes :- (i) Old serviceable water tubing retrieved from serial item No. 93.00 here-in-before shall be used. (ii) Quoted rate shall be deemed to include cost of GI fittings (ISI marked). Old fittings shall not be used.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Fixing only GI water tubing 20 mm bore, medium grade, with & including supply & fixing all new fittings (ISI marked) complete fixed to walls and ceilings or laid in floors all as specified & as directed. Notes :- (i) Old serviceable water tubing retrieved from serial item No. 94.00 here-in-before shall be used. (ii) Quoted rate shall be deemed to include cost of GI fittings (ISI marked). Old fittings shall not be used.
Dismantling old unserviceable PVC water tank capacity exc 250 ltr and not exc 500 ltr & removal from site etc complete all as specified and directed.
Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
S&F in repairs 15mm dia Angle Valve (Basin Inlet Connection) brass CP complete all as specified and as directed. Make - Cat Part No MQT-526KN of ESSCO Jaquar or equivalent of makes mentioned in Appx 'C' here-in-after.
S&F Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and as directed.
S&F in repairs 15 mm bore bib tap, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and directed.
S&F 15 mm bore bib tap, cast copper alloy, screwed down, screwed for iron pipe or for brass ferrule all as specified and directed.
S&F in repairs 20mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
Supply only 15mm bore fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes & fly nuts, screwed for iron pipes all as specified and directed.
S&F in repair brass chromium plated shower rose 125mm size with or without swivel joints including 195mm long brass chromium plated arm with bend 45 degree etc complete all as specified and directed.
S&F in repairs Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) all as specified and directed.
S&F tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges all as specified and directed.
S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
S&F 20mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
S&F in repairs PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&F PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&Fin repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling, making good to floor, complete all as specified.
S&F in repairs PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified.
S&F in repairs vitreous china wash hand basin, white, oval shape counter top size 550mm x 400mm fixed in RCC counter with & including 32 mm dia PVC waste pipe 90cm long and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified. Note :- Supply only pillar tap shall be measured & paid seperately under relevant item of BoQ.
S&F in repairs vitreous china bowl type urinal flat back, size of 465 x 355 x 265mm (minimum) white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia complete all as specified.
S&F vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including provision of PCC (1:5:10) type E2 in filling, making good to floor, complete all as specified.
S&F PVC valveless symphonic action type low level flushing cistern (ISI marked) of 10 litre capacity including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified.
S&F vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe 90cm long and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified. Note :- Supply only pillar tap shall be measured & paid seperately under relevant item of BoQ.
S&F vitreous china half stall urinal, 580mmx380mmx350mm (minimum), white with grating and union for discharge pipe includng providing and fixing plugs, bedding urinal against wall in CM (1:2), securing urinal to plugs with and including 60mm long brass screws complete with PVC flush pipe complete all as specified and as directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints laid in trenches / floor complete all as specified.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls complete all as specified.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls including taking down existing u/s pipe with fittings complete all as specified.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls including taking down existing u/s pipe with fittings complete all as specified.
S&F 110mm bore PVC (SWR) bend with access door all as specified & as directed.
S&F 75mm bore PVC (SWR) bend with access door all as specified & as directed.
S&F PVC (SWR) 'P’ trap 125/110 mm bore complete all as specified & as directed.
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and directed.
S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal provided with access door complete all as specified and directed.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified.
S&F PVC(SWR) branch piece single(single Y) equal or unequal 110mm bore etc complete all as specified and directed.
S&F PVC(SWR) branch piece single(single Y) equal or unequal 75mm bore etc complete all as specified and directed.
S&F in repairs PVC (SWR) floor trap dia of outlet 75mm, with PTMT grating including jointing with solvent cement to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate etc complete all as specified and directed.
S&F PVC (SWR) floor trap dia of outlet 75mm, with PTMT grating including jointing with solvent cement all as specified.
S&F Stack clamps made out of 50mm X 5mm flat iron and 16 mm round iron stay incl bolts and nuts and securing ends stays to wall or roof includding taking down the existing clamps for rain water pipe or CI pipe 100/110 mm bore at any height etc complete all as specified and as directed.
Material and labour PCC 1:3:6 type C-2 using 40 mm graded stone aggregate in concrete bed to RCC NP2 drain pipes including forming cradles in after they are laid and tested complete for 150mm bore pipe all as specified and as directed.
M&L for 150mm bore reinforced concrete pipe, class NP2, laid and jointed (in CM 1:1) complete with collars all as specified & as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete (1:2:4) type B-1 using graded stone aggregate, smooth finished and reforming benching as required for 150mm bore pipe etc complete all as specified and as directed .
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed steel box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
All as per item No. 143.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 143.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per srl item No. 143.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230 Volts.
S&F flush type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F LED bulb of capacity 15 W, ISI marked, all as specified and directed.
S&F LED light fitting 1x18W/20W/22W, regal batten for LED including ultra bright glass LED Tubelight with very high efficacy, single / double side connection all as specified and directed. Make : Havells Regal batten Cat Part No REGALBATTENT8UPTO1X22WSSBSWH & LED tube rod Cat Part No PHOTONULTRAE2.01213T8SSTL20WLED865SPC of Havells or Surya Cat Part No SLE BT 20 MS for batten & LED tube rod Cat Part No SLE TL-DS 18 PC Reform of Surya or Cat No LTTB4F20WLEDEW BATTEN for batten & LED tube rod Cat No Cat No LT4F20WLEDT8/WDI of C&S or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F street light LED light fitting 60 Watt, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device , connected with and including 0.5 sqmm flexible copper multistranded conductor cable fixed on wall / pole including security light bracket made to shape out of GI pipe 40mm dia light grade 1.5m length and fixed with MS clamps of size 40x5mm - 2 Nos, nuts, bolts and washers fixed on wall all as specified and directed. Make : Cat Part No ENDURAPEARLNEOSL60WLED757PASYTOPC of Endura Peral Neo series of Havells or PCGLS T1 60 N (Item Code PUBO506015) of Polycab or LTESSI60WLED of C&S or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S & F main switch iron clad rewirable type TPN 63 Amp 415 Volts fixed on pole / panel / wall etc including making connections with and including suitable size of cable of suitable type, size and length complete all as specified & directed.
S & F sheet metal enclosure, double door type, having door earthing, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts. Make :- Indo Asian Cat Part No 810347 or equivalent of makes mentioned in list of makes here-in-after .
S & F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S & F MCB SPN, 32 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
Supply & fixing and testing exhaust fan of 300mm sweep heavy duty, double ball bearing, 1400 RPM, suitable for SP 230 / 250 volt, 50 Hz AC supply complete with louver shutter including fixing / grouting of frame in wall & cutting opening complete with covers & connecting with & including 3 Nos 1.5 sqmm single core, PVC insulated but unsheathed FRLS 1100 volts grade cable with multi-stranded copper conductor from ceiling rose to fan complete all as specified and directed. Make : Model No Turbojet SP of Havells or Cat Part No Supreme DLX HD of Bajaj or Cat No Transair of Crompton equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of aluminium stranded conductors of size 10 Sqmm all as specified & directed.
S&F 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of aluminium stranded conductors of size 10 Sqmm all as specified & directed.
Supply , laying , jointing, testing and commissioning of cable of size 16 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors as per IS 7098 (Part-I), laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness afterlaying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. .
S&F Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M & L for earthing complete with galvanized iron earth plate electrode of size 60cmx60cmx6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to the galvanized earth lead wire 4mm dia by means of GI bolts/nuts/ washers, protected by 15mm bore GI light grade pipe from earth plate and upto 3m along pole fixed with 2 clamps made from mild steel flat iron 25x3mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15cm thick all around bottom and top, 20mm GI medium grade pipe for watering and including funnel , wire mesh , RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm X 30 cm X 8 cm thick reinforced with expanded metal weighing not less than 4Kg/Sqm, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-3 of SSR part-I and connected to earthing point and testing on completion complete all as specified & as directed. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
M & L for earthing complete with galvanized iron earth plate electrode of size 60cmx60cmx6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to the galvanized earth lead wire 4mm dia by means of GI bolts/nuts/ washers, protected by 15mm bore GI light grade pipe from earth plate and upto 3m along pole fixed with 2 clamps made from mild steel flat iron 25x3mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15cm thick all around bottom and top, 20mm GI medium grade pipe for watering and including funnel , wire mesh , RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm X 30 cm X 8 cm thick reinforced with expanded metal weighing not less than 4Kg/Sqm, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-3 of SSR part-I and connected to earthing point and testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
virendra constructions
Puja Traders
Balaji Construction Co.
m/s krishna engineers1
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .