Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC LOWSET BIDDER | |
| 2 | L2₹38.8 L+₹91,036 (2.40%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN LOWEST BIDDER | |
| 3 | L3₹38.8 L+₹94,335 (2.49%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L3 | Rejected-Finance HIGHER THAN LOWEST BIDDER | |
| 4 | L4₹45.0 L+₹7.2 L (19.0%)Rejected-Finance AT ROAD NEAR MES TINALI PO CHABUA DIST DIBRUGARH ASSAM | L4 | Rejected-Finance HIGHER THAN LOWEST BIDDER | |
| 5 | L5₹45.6 L+₹7.7 L (20.4%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L5 | Rejected-Finance HIGHER THAN LOWEST BIDDER |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
26 Jun 2023, 6:00 pmClosed
GE 872 EWS
GE 872 EWS, C/O 99 APO
REPAIRS/MAINT TO INTERNAL ELECTRIFICATION, REPAIRS/ MAINT/ SERVICING TO VARIOUS TYPES OF FANS AND GEYSERS AND REPAIRS/ MAINT/ SERVICING TO COOLING APPLIENCES AT LIKABALI AND REPAIRS/MAINT TO INTERNAL ELECTRIC SERVICES AT TECH AREA OF LIKABALI MIL STN
2023_MES_591522_2
8518/T-18/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
LIKABALI
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹97,000
Yes
30 Jun 2023
9 Jun 2023
27 Jun 2023
9 Jun 2023
26 Jun 2023
14 Jun 2023
9 Jun 2023 - 11 Jun 2023
Amount
REPAIRS & MAINT TO INTERNAL ELECTRIFICATIONS
M&L Taking down carefully Copper/Aluminium Point Wiring (Light/Fan, Socket or Power) complete from in any position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets (but excluding Light Fittings of any descrip-tion), etc., Making Good Disturbed Surfaces of Walls/Ceillings, etc. in Cement Mortar 1:3 including Providing Surface Treatment (Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Taking down/out Unserviceable Sub-main Wiring from Batten/ Conduit/ PVC Casing Capping of any description, Making Good disturbed Portion/ Surfaces of Walls/ Floor/ Ceiling, etc. with Cement Mortar 1:3 including providing Surface Treatment to match the Existing Treatment/ Finishes on Ground, complete all as specified and as directed.
M&L Taking down Unserviceable Service Connection Cable with Suspension Wire of any description from any Situation, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (25/32/40mm Width) along with all Fitting/Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. including suitable Size PVC Board with 3.0mm thick Plastic Laminated Sheet Cover for mounting Switches, Sockets, Regulators, etc., Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (25/32/40mm Width) along with all Fitting/Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. including suitable Size PVC Board with 3.0mm thick Plastic Laminated Sheet Cover for mounting Switches, Sockets, Regulators, etc., Earth Continuity Wire connected to Common Earth dolly for ONE FAN POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (25/32/40mm Width) along with all Fitting/Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. including suitable Size PVC Board with 3.0mm thick Plastic Laminated Sheet Cover for mounting Switches, Sockets, Regulators, etc., Earth Continuity Wire connected to Common Earth dolly for ONE BELL POINT controlled by One Bell Push 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire for ONE 6 AMP 5 PIN SOCKET OUTLET POINT on SAME BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (25/32/40mm Width) along with all Fitting/Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. including suitable Size PVC Board with 3.0mm thick Plastic Laminated Sheet Cover for mounting Switches, Sockets, Regulators, etc., Earth Continuity Wire connected to Common Earth dolly for ONE 6 AMP 5 PIN SOCKET OUTLET POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (25/32/40mm Width) along with all Fitting/Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. including suitable Size PVC Board with 3.0mm thick Plastic Laminated Sheet Cover for mounting Switches, Sockets, Regulators, etc., Earth Continuity Wire connected to Common Earth dolly for ONE 16 AMP 3/5 PIN SOCKET OUTLET POINT on INDEPENDENT BOARD, complete all as specified and all as directed.
M&L Sub-main Wiring with 2-Runs of 2.5 Sqmm (nominal area) 1100 Volt PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable and 1-Run of 2.5 Sqmm (nominal area) 1100 Volt PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable Size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :- (a) Cost of 3-Run of Cables & 1-Run of PVC Casing Capping will deemed to be included in the Quoted Unit Rate and the same also Mesured as ONE UNIT. (b) Sub-main Wiring will be measured PVC Casing Capping only. Wire for looping (as ordered/required), etc. will deemed to be included in the Quoted Unit Rate.
M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable Size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :- (a) Cost of 3-Run of Cables & 1-Run of PVC Casing Capping will deemed to be included in the Quoted Unit Rate and the same also Mesured as ONE UNIT. (b) Sub-main Wiring will be measured PVC Casing Capping only. Wire for looping (as ordered/required), etc. will deemed to be included in the Quoted Unit Rate.
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable Size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :- (a) Cost of 3-Run of Cables & 1-Run of PVC Casing Capping will deemed to be included in the Quoted Unit Rate and the same also Mesured as ONE UNIT. (b) Sub-main Wiring will be measured PVC Casing Capping only. Wire for looping (as ordered/required), etc. will deemed to be included in the Quoted Unit Rate.
S&F PVC Casing Capping of Size 25mm, ISI Marked including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out Unserviceable PVC Casing Capping, complete all as specified and as directed.
S&F PVC Casing Capping of Size 32mm, ISI Marked including all Fitting/ Fixtures such as Tee, Bend, Elbow, Socket, Saddles, etc. including Taking down/ out Unserviceable PVC Casing Capping, complete all as specified and as directed.
S&F PVC Rectangular Block of Size 100x100x50mm Deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out Unserviceable PVC Block, complete all as specified and as directed.
S&F PVC Rectangular Block of Size 175x100x50mm Deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out Unserviceable PVC Block, complete all as specified and as directed.
S&F PVC Rectangular Block of Size 200x150x50mm Deep with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out Unserviceable PVC Block, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way, 230 Volt AC and Connecting up, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Switch Piano, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt AC and Connecting up, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Socket Outlet, complete all as specified and as directed.
S&F Switch Socket Combination 6 Amp, 2-in-1, Flush type, Universal, 230 Volt AC and Connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 6 Amp, 2-in-1, Flush type, Universal, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Switch Socket Combination 16 Amp, 3 Pin, Flush type, Universal, 230 Volt AC and Connecting up, complete all as specified and as directed.
S&F Switch Socket Combination 16 Amp, 3 Pin, Flush type, Universal, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Switch Socket Combination 2-in-1, 3 Pin, 6/16 Amp, Multi-Plug, Flush type, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Switch Socket Combination, complete all as specified and as directed.
S&F Lamp Holder PVC/ Polycarbonate type with Back Plate suitable for Batten Fitting and Connecting up including Taking down/ out Unserviceable Lamp Holder, complete all as specified and as directed.
S&F Ceiling Rose Surface type, Bakelite 65x50mm, 3 Terminals suitable for 230 Volt AC, 6 Amp and Connecting up, complete all as specified and as directed.
S&F Ceiling Rose Surface type, Bakelite 65x50mm, 3 Terminals suitable for 230 Volt AC, 6 Amp and Connecting up including Taking down/ out Unserviceable Ceiling Rose, complete all as specified and as directed.
S&F Ceiling Fan Regulator 230 Volt AC, Electronic, Rotary Stepped type, 230 Volt and Connecting up, complete all as specified and as directed.
S&F Ceiling Fan Regulator 230 Volt AC, Electronic, Rotary Stepped type, 230 Volt and Connecting up including Taking down/ out Unserviceable Fan Regulator, complete all as specified and as directed.
S&F Bell Push 6 Amp, Single Pole, Flush Type 230/240 Volt AC for operating Bell/ Buzzer and Connecting up, complete all as specified and as directed.
S&F Bell Push 6 Amp, Single Pole, Flush Type 230/240 Volt AC for operating Bell/ Buzzer and Connecting up including Taking down/ out Unserviceable Bell Push, complete all as specified and as directed.
S&F Bell Ding Dong, 230 Volt AC, Single Pole and Connecting up, complete all as specified and as directed.
S&F Bell Ding Dong, 230 Volt AC, Single Pole and Connecting up including Taking down/out Unserviceable Bell, complete all as specified and as directed.
S&F Modular Switch 10 Amp, 1-Module, Single Pole, 1-way, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Modular Switch, complete all as specified and as directed.
S&F Modular Switch 10 Amp, 1-Module, Single Pole, 2-way, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Modular Switch, complete all as specified and as directed.
S&F Modular Switch 16 Amp, 1-Module, Single Pole, 1-way, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Modular Switch, complete all as specified and as directed.
S&F Modular Socket Outlet 6 Amp, 2-Modules, 2 & 3 Pin Combined, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Modular Socket Outlet, complete all as specified and as directed.
S&F Modular Socket Outlet 6/16 Amp, 2-Modules, 2 & 3 Pin Combined, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Modular Socket Outlet, complete all as specified and as directed.
S&F Modular Switch Socket Combination 16 Amp, 2-Modules, 6 Pin Combined, 230 Volt AC and Connecting up including Taking down/ out Unserviceable Modular Switch Socket Combination, complete all as specified and as directed.
S&F Modular Fan Regulator, 2-Modules, Stepped type, 120 Watt and Connecting up including Taking down/ out Unserviceable Modular Fan Regulator, complete all as specified and as directed.
S&F Modular Bell Push 6 Amp, 1-Module, Single Pole, Flush Type 230/240 Volt AC for operating Bell/ Buzzer and Connecting up including Taking down/ out Unserviceable Modular Bell Push, complete all as specified and as directed.
S&F Electronic Ballast High Performance (THD 10%) 1x36 Watt and Connecting up including Taking down/out Unserviceable Ballast, complete all as specified and as directed.
S&F LED Panel Driver 24 Watt to 36 Watt, 230 Volt and fixing to existing Light Fitting including Taking down/out Unserviceable LED Driver, complete all as specified and as directed.
S&F Starter Universal (as per Sample/ as approved) suitable for 18/20 Watt Tube Light Fitting, 230/240 Volt, and Connecting up including Taking down/out Unserviceable Starter, complete all as specified and as directed.
S&F LED Bulb/ Lamp 9/ 10 Watt, 230 Volt, Self-ballasted and fixing to existing Light Fitting including Taking down/out Unserviceable Bulb/ Lamp, complete all as specified and as directed.
S&F LED Bulb/ Lamp 12 Watt, 230 Volt, Self-ballasted and fixing to existing Light Fitting including Taking down/out Unserviceable Bulb/ Lamp, complete all as specified and as directed.
S&F LED Bulb/ Lamp 15 Watt, 230 Volt, Self-ballasted and fixing to existing Light Fitting including Taking down/out Unserviceable Bulb/ Lamp, complete all as specified and as directed.
S&F LED Batten/ Tube 18 Watt, 4 Feet Long suitable for existing LED Tube Light Fitting including Taking down/out Unserviceable Batten/ Tube, complete all as specified and as directed.
S&F LED Batten/ Tube 20 Watt, 4 Feet Long suitable for existing LED Tube Light Fitting including Taking down/out Unserviceable Batten/ Tube, complete all as specified and as directed.
S&F Decorative LED Bulkhead Light Fitting 1x10 Watt including LED Light, Driver, Holder, Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
S&F Wall mounted, LED 10 Watt Light Fitting, Mirror type, Premium Opal Glass with Integrated Electronic Driver Nickel, 230 Volt, complete with all Accessories and Connecting up with Twin Core Twisted Flexible Copper Conductor Cable from Ceiling Rose to Light Fitting including Taking down/ out Unserviceable Light Fitting, complete all as specified and as directed.
S&F Round shape LED 12 Watt 220 Volts AC Recessed type with High Efficiency PMMA Diffuser Soft Glare Free Light complete with Drivers, Holders, LED Lamp suitable for Roof Ceiling, Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Cylindro Track/ Focus Light Fitting 15 Watt complete Set, 230 Volt Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/ out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Tube Light Fitting 18 Watt 4 Feet long Cool Day Light Fitting, 230 Volt and fixing to existing Light Fitting including Taking down/out Unserviceable Tube Light Fitting, complete all as specified and as directed.
S&F LED Tube Light Fitting 20 Watt 4 Feet long Cool Day Light Fitting, 230 Volt and fixing to existing Light Fitting including Taking down/out Unserviceable Tube Light Fitting, complete all as specified and as directed.
S&F LED Light Fitting 20 Watt, 4 Feet, Mirror type with High Out-put Diffuser, 220 Volt AC, Decorative type with Driver, Holder and LED Lamp Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Luminaire 600x600mm, 35/36 Watt, 220 Volt AC Recessed type with High efficiency PMMA Diffuser Soft Glare Free Light complete with Driver, Holders, LED Lamp suitable for Roof Ceiling, Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Flood Light 70 Watt 230 Volt AC, Outdoor type with Thermal Management in Multiple Optics and equipped with IP-66 Protection, with Impact and Corrosion Resistant complete with Driver and LED Lamps and Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
S&F LED Flood Light 100 Watt 230 Volt AC, Outdoor type with Thermal Manage-ment in Multiple Optics and equipped with IP-66 Protection, with Impact and Corrosion Resistant complete with Driver and LED Lamps and Connecting up with 3 Core Flexible Copper Conductor Cable of suitable Size including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.
S&F MCB 6 Amp to 32 Amp, Single Pole, 'B' Series, 50 Hz, 10 kA, 240 Volt and Connecting up including Taking down/out Unserviceable MCB, complete all as specified and as directed.
S&F MCB 40 Amp, Single Pole, 'B' Series, 50 Hz, 10 kA, 240 Volt and Connecting up including Taking down/out Unserviceable MCB, complete all as specified and as directed.
S&F MCB 6 Amp to 32 Amp, Single Pole & Neutral, 'C' Series, 50 Hz, 10 kA, 240 Volt and Connecting up including Taking down/out Unserviceable MCB, complete all as specified and as directed.
S&F MCB 40 Amp to 63 Amp, Single Pole & Neutral, 'C' Series, 50 Hz, 10 kA, 240 Volt and Connecting up including Taking down/out Unserviceable MCB, complete all as specified and as directed.
S&F MCB Triple Pole & Neutral 25 Amp to 32 Amp, 'C' Curve, 10 kA Breaking capacity, 415 Volt and Connecting up including Taking down/out Unserviceable MCB, complete all as specified and as directed.
S&F MCB Triple Pole & Neutral 40 Amp to 63 Amp, 'C' Curve, 10 kA Breaking capacity, 415 Volt and Connecting up including Taking down/out Unserviceable MCB, complete all as specified and as directed.
S&F Factory made Sheet Metal Enclosure for DB's when MCBs to be used SPN 2-way, 240 Volt AC, Single Door, Front Openable, IP-43 Protected, Epoxy Based Powder coated without Bus-bar and Connecting up including Taking down Unserviceable Sheet Metal Enclosure of any description, complete all as specified and as directed.
S&F Factory made Sheet Metal Enclosure for DB's when MCBs to be used SPN 4-way, 240 Volt AC, Single Door, Front Openable, IP-43 Protected, Epoxy Based Powder coated suitable for mounting MCB DP/ SPN as Incomer and MCB SP as Out-goings with 200 Amps rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Connecting up including Taking down Unserviceable Sheet Metal Enclosure of any description, complete all as specified and as directed.
S&F Factory made Sheet Metal Enclosure for DB's when MCBs to be used SPN 8-way, 240 Volt AC, Double Doors, Front Openable, IP-43 Protected, Epoxy Based Powder coated suitable for mounting MCB DP/ SPN as Incomer and MCB SP as Out-goings with 200 Amps rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Connecting up including Taking down Unserviceable Sheet Metal Enclosure of any description, complete all as specified and as directed.
S&F Factory made Vertical Sheet Metal Enclosure for DB's when MCBs to be used TPN 4-way, 415 Volt AC, Single Door, Front Openable, IP-43 Protected, Epoxy Based Powder coated suitable for mounting MCB DP/ SPN as Incomer and MCB SP as Out-goings with 200 Amps rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Connecting up including Taking down Unserviceable Sheet Metal Enclosure of any description, complete all as specified and as directed.
S&F 1100 Volts Grade Heavy duty Cable PVC insulated Aluminium Conductor, served with Inner Sheathing of PVC Tape and Overall PVC Sheathed Cable, Cross-sectional Area 4.0 Sqmm, 2 Core in Service Connection and suspended by Insulating Hangers not more than 1.0 Metre apart including 4.0mm Suspension Wire, complete all as specified and as directed.
S&F 1100 Volts Grade Heavy duty Cable PVC insulated Aluminium Conductor, served with Inner Sheathing of PVC Tape and Overall PVC Sheathed Cable, Cross-sectional Area 6.0 Sqmm, 2 Core in Service Connection and suspended by Insulating Hangers not more than 1.0 Metre apart including 4.0mm Suspension Wire, complete all as specified and as directed.
S&F 1100 Volts Grade Heavy duty Cable PVC insulated Aluminium Conductor, served with Inner Sheathing of PVC Tape and Overall PVC Sheathed Cable, Cross-sectional Area 10 Sqmm, 2 Core in Service Connection and suspended by Insulating Hangers not more than 1.0 Metre apart including 4.0mm Suspension Wire, complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description, complete all as per specified and as directed.
REPAIRS & MAINT TO FANS
M&L Taking down Unserviceable Ceiling Fan, Exhaust Fan, Wall Mounted Fan, Air Circulator Fan of any Make & Size after disconnecting and removing to AGE E/M Store Yard at LIKABALI for Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects and Repair works involves, Re-hanging the same in Original Position after repaired and Providing Electric Connection, complete all as specified and as directed. NOTE :- (a) Any Minor Items as well as Any Repair Works involves to Make the Fan Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Rewinding & Other Parts required to be replaced will be Measured and Paid separately as "S&F"/"M&L" under relevant Items here-in-after.
S&F Ball Bearing (Size as per existing one/ as approved) suitable for Ceiling Fan 1200/1400mm Sweep including Taking down/out Unserviceable Ball Bearing, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
S&F Condenser 1.5 mfd suitable for Ceiling Fan & Wall Mounted Fan of any Make and Size including Taking down/out Unserviceable Condenser, complete all as specified and as directed. MAKE : AMCAP/ EPCOS/ HAVELLS
S&F Condenser 2.5 mfd suitable for Ceiling Fan & Wall Mounted Fan of any Make and Size including Taking down/out Unserviceable Condenser, complete all as specified and as directed. MAKE : AMCAP/ EPCOS/ HAVELLS
S&F Condenser 3.15 mfd suitable for Ceiling Fan & Wall Mounted Fan of any Make and Size including Taking down/out Unserviceable Condenser, complete all as specified and as directed. MAKE : AMCAP/ EPCOS/ HAVELLS
S&F Fan Blade Aluminium suitable for Ceiling Fan 1200mm Sweep of any Make/ Model, Aero dynamically balanced and screwed with suitable Size Mild Steel Screws including Taking down/out Unserviceable Fan Blade, complete all as specified and as directed.
S&F Fan Blade Aluminium suitable for Ceiling Fan 1400mm Sweep of any Make/ Model, Aero dynamically balanced and screwed with suitable Size Mild Steel Screws including Taking down/out Unserviceable Fan Blade, complete all as specified and as directed.
M&L Frame suitable for Exhaust Fan 380/400mm Sweep with Mild Steel Flat and fixing with Bolts, Nuts, Washers, etc. as required/ordered including Taking down/out Unserviceable Frame, complete all as specified and as directed.
S&F Gun Metal Bush (Size as per existing One/ as approved) suitable for Ceiling/ Exhaust/ Cabin Fan of any Make/Model and any Size including Taking down/out Unserviceable Bush, complete all as specified and as directed. MAKE : FAG/ NBC/ SKF
M&L Louver Shutter suitable for Exhaust Fan 380mm Sweep of any Make/ Model, fixing with Bolts, Nuts, Washers, etc. and grouting to Brick/PCC Block Walls includ-ing Taking down/out Unserviceable Louver Shutter, complete all as specified and as directed.
M&L Louver Shutter suitable for Exhaust Fan 400mm Sweep of any Make/ Model, fixing with Bolts, Nuts, Washers, etc. and grouting to Brick/PCC Block Walls include-ing Taking down/out Unserviceable Louver Shutter, complete all as specified and as directed.
M&L Mild Steel Down Rod 15mm nominal dia and 18" long, heavy duty, duly painted in matching Colour including Taking down/out Unserviceable Mild Steel Down Rod, complete all as specified and as directed.
M&L Mild Steel Down Rod 15mm nominal dia and 24" long, heavy duty, duly painted in matching Colour including Taking down/out Unserviceable Mild Steel Down Rod, complete all as specified and as directed.
M&L Mild Steel Down Rod 15mm nominal dia and 36" long, heavy duty, duly painted in matching Colour including Taking down/out Unserviceable Mild Steel Down Rod, complete all as specified and as directed.
S&F Oscilating Mechanism for Wall Fan 400mm Sweep including Taking down/ out Unserviceable Oscilating Mechanism, complete all as specified and as directed.
S&F Rubber Bush (Reel type) Standard Size and type duly fixed with suitable Size Mild Steel Bolt, Nuts, etc. including Taking down/out Unserviceable Rubber Bush, complete all as specified and as directed.
M&L Transporting Ceiling Fan 1200mm Sweep from AGE E/M Store Yard at LIKABALI to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) Providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Ceiling Fan 1400mm Sweep from AGE E/M Store Yard at LIKABALI to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) Providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Exhaust Fan 250/300mm Sweep from AGE E/M Store Yard at LIKABALI to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) Providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Exhaust Fan 350/400mm Sweep from AGE E/M Store Yard at LIKABALI to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) Providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Wall/ Cabin Fan 400mm Sweep from AGE E/M Store Yard at LIKABALI to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) Providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Transporting Pedestal Fan of any Sweep from AGE E/M Store Yard at LIKABALI to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing) Providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Taking down Ceiling Fan of any Sweep from any Situation after disconnecting, Preparing Old Painted Surfaces of Fan including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One coat of Synthetic Enamelled Paint (as approved) with Spray Painting Machine and Writing MES No. with Black Paint, Re-hanging the Fan in Original Postion & Re-connecting and Testing, complete all as specified and as directed.
REPAIRS & MAINT TO GEYSERS
M&L Taking down/Lowering Defective/ Unserviceable Electric Water Heater (Geyser) of any Capacity/ Make/ Type from any Height by disconnecting all Water and Electric Supply Connections, Opening & Checking in Presence of a Board of Officers to ascertain the quantum of Defects and Repair Works involves, Repairing/ Replacing of Unserviceable Accessories, Replacing of all Rusted Nuts, Bolts including Tightening of Nuts, Bolts, De-scaling Inner Tank & Inter Connection Assembly, Cleaning thoroughly with Diluted Acid, Brazing/ Gas Welding of Inter Connection Assembly, Checking of Inner Tank to make Fully Leakeage Proof and Testing the same with Water Filling/Air Pressure, Check & Maint of Thermostate Switch, Pressure/ Safety Valve Check & Connecting Earth Continuity to Electric Water Heater, Re-fixing/ Re-mounting the same in Original Position and Providing all Water all Electric Supply Connections and Testing, complete all as specified and as directed. NOTE :- (a) Any Minor Items as well as Any Repair Works involves to Make the Water Heater (Geyser) Functional, even if not notified by the Board of Officers, the same shall be carried out by the Contractor without any Extra Cost to the Department. (b) Unserviceable Parts need to be replaced will be Measured and Paid separately as "S&F" under relevant Items here-in-after.
S&F Base Assembly (Inner), Brass Chromium plated complete of any shape and Size with Inlet, Outlet, Thermostate Slot, drain plug, Clamp or Bolts to fixing Heating Element as existing Shape suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out Unserviceable Base Assembly (Inner), complete all as specified and as directed.
S&F Glass Wool (Insulation Materials) superior quality (as approved) suitable for Electric Water Heater 25 Litre capacity of any Make/Model including Taking out Unserviceable Glass Wool, complete all as specified and as directed.
S&F Heating Element 1.5 KW 230 Volt AC for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out Unserviceable Heating Element, complete all as specified and as directed. MAKE : BAJAJ/ DITZ/ POWER PACK/ THEETA
S&F Heating Element 2.0 KW 230 Volt AC for Electric Water Heater 25 Litre capacity of any Make/Model including Taking down/out Unserviceable Heating Element, complete all as specified and as directed. MAKE : BAJAJ/ DITZ/ POWER PACK/ THEETA
S&F Indication Lamp Rounded type 230/240 Volt suitable for Water Heater (Geyser) of any Capacity/ Make/ Model and Testing including Taking down/out Unserviceable Indication Lamp, complete all as specified and as directed.
S&F Outer Body complete with Top & Bottom Cover, Inspection Plate suitable for Electric Water Heater 25 Litre capacity of any Make/Model and applying Two Coats of Synthetic Enamelled Paint (as approved) ove a coat of Red Oxide Zinc Chrome Primer with Spray Painting Machine including Taking down/out Unserviceable Outer Body complete with Top & Bottom Cover, complete all as specified and as directed.
S&F Pressure Release Valve Dead Weight type for Water Heater (Geyser) of any capacity, any Make including Taking down/out Unserviceable Pressure Release Valve, complete all as specified and as directed.
S&F Thermostate Switch with Thermal Setting 40 °C to 90 °C capacity and Relay 240 Volt AC suitable for Electric Water Heater 25/50 Litre capacity of any Make/ Model including Taking down/out Unserviceable Thermostate Switch, complete all as specified and as directed.
M&L Repairs to Water Heater of any capacity and type by Taking out Unserviceable Water Tank (Inner Shell), Brazing to leaking Portion or Patching Work as required with using Copper Plate 1.5mm thick including shaping to Original Shape and Size, complete all as specified and as directed.
M&L Steel Water Tubing 15mm bore (dia), Galvanised, Medium grade (upto 4.00 RM) with all Fittings for Connecting from Existing Pipe Line to Geyser Inlet Pipe and from Geyser Outlet Pipe to Tap including Taking down/out GI Pipe, complete all as specified and as directed.
REPAIRS & MAINT TO AIR CONDITIONERS
M&L Taking down/ Lowering Defective Split AC 1.5 TR /2.0 TR Capacity of any Make from any Height by disconnecting all Electric Connections, Opening & Checking in presence of a Board of Officers to ascertain the quantum of Defects & Repair Works involves, Repairing/Replacing of Unserviceable Parts, Cleaning thoroughly Condensing Unit to achive Proper Cooling effect, Checking of Electronic Circuit of Machine, Changing of Wiring with proper Size PVC insulated Copper Wires, Brazing the Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof, Re-install the Same in Original/ New Position and Providing Electric Connection, Testing on Completion, complete all as specified and as directed. NOTE :- (a) Any Minor Items as well as Any Repair Works involves to Make the Split AC 1.5 TR /2.0 TR Capacity Functional, even if not notified by the Board of Officers, the same will be carried out by the Contractor without any Extra Cost to Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items here-in-after.
M&L Blower Motor with Extended Shaft and Rotary Blade Complete (as per existing One/ as approved), Single Phase, 230/240 Volt, AC to match the Same Model and Capacity for Indoor Unit of Split type AC 1.5 TR / 2.0 TR Capacity, Providing Connections and Testing including Taking down/ out Unserviceable Blower Motor, complete all as specified and as directed. MAKE : BLUE STAR/ CARRIER/ LG/ SAMSUNG/ VIDEOCON
M&L Compressor Sealed Unit, Rotary type (as per existing One/ as approved) to match the Same Model and Capacity for Split AC 1.5 TR Outdoor Unit with All Accessories including necessary Brazing to Stop Leakage, Providing Connections and Testing including Taking down/ out Unserviceable Compressor, complete all as specified and as directed. MAKE : BPL/ CARRIER/ EMERSON/ HITACHI/ KIRLOSKAR/ LG/ TOSHIBA
M&L Compressor Sealed Unit, Rotary type (as per existing One/ as approved) to match the Same Model and Capacity for Split AC 2.0 TR Outdoor Unit with All Accessories including necessary Brazing to Stop Leakage, Providing Connections and Testing including Taking down/ out Unserviceable Compressor, complete all as specified and as directed. MAKE : BPL/ CARRIER/ EMERSON/ HITACHI/ KIRLOSKAR/ LG/ TOSHIBA
M&L Cooling Coil/ Condensing Unit (as per existing One/ as approved) to match the Same Model & Capacity for Split type AC 1.5 TR / 2.0 TR Capacity, Providing Connections and Testing including Taking down/ out Unserviceable Cooling Coil/ Condensing Unit, complete all as specified and as directed.
M&L Fan Motor with Blade (as per existing One/ as approved) to match the Same Model & Capacity for Outdoor Unit of Split type AC 1.5 TR / 2.0 TR Capacity, Providing Connections and Testing including Taking down/ out Unserviceable Fan Motor with Blade, complete all as specified and as directed. MAKE : BLUE STAR/ CARRIER/ LG/ SAMSUNG/ VIDEOCON
M&L Insulation On and Around Suction and Discharge Copper Piping with 6.0mm thick Flexible Thermo Cool Heat Resistant of best quality (as approved) duly scrapped with sticking Tape and Testing including Removing/ Taking down existing/ demaged Insulations, complete all as specified and as directed.
M&L Indoor Unit Complete Set (as per existing One/ as approved), 230 Volt to match the Same Model & Capacity Capacity, Providing Connections and Testing including Taking down/ out Unserviceable Indoor Unit, complete all as specified and as directed.
M&L Remote Auto Sensor Unit & RC (as per existing One/ as approved) for Split type AC 1.5 TR / 2.0 TR and Testing including Taking down/out Unserviceable Remote Auto Sensor Unit, complete all as specified and as directed. MAKE : BLUE STAR/ CARRIER/ HITACHI/ LG/ SAMSUNG/ TOSHIBA
M&L Running Capacitor 45/ 50/ 60 mfd (as per existing One/ as approved) 230/240 Volt, 50 Hz for Split type AC 1.5 TR / 2.0 TR Capacity, Providing Connections and Testing including Taking down/ out Unserviceable Capacitor, complete all as specified and as directed. MAKE : ANNAPURNA/ KELTRON/ SIEMENS/ USHA
M&L Repairs to Power Circuit (PC Plate) for Split AC 1.5 TR Capacity and Making Functional and Testing, complete all as specified and as directed.
M&L Complete Servicing Indoor & Outer Unit of Split type AC 1.5 TR / 2.0 TR Capacity of any Make & Model in Situ by Cleaning including Changing of Air Filter in Indoor Unit and Testing, complete all as specified and as directed. NOTE : Any Minor Items if required on Servicing to make the AC Functional, the same will be provided by the Contractor without any Extra Cost to the Department.
Supply & Charging of Refrigerant F-22 to Split type AC 1.5 TR Capacity after Cleaning of Condenser Unit, Evoporator Unit, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof & Vaccuming and Testing, complete all as specified and as directed.
Supply & Charging of Refrigerant F-22 to Split type AC 2.0 TR Capacity after Cleaning of Condenser Unit, Evoporator Unit, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof & Vaccuming and Testing, complete all as specified and as directed.
M&L Shifting Split type AC 1.5 TR / 2.0 TR Capacity Outer Unit with All Accessories including necessary Gas Charging, Welding, Brazing to Stop Leakage Vacum Test Pressure, Testing, insisting thick Flexible Thermo Cool and Servicing of Indoor and Outdoor Unit, complete all as specified and as directed.
REPAIRS & MAINT TO REFRIGERATORS
M&L Opening Defective Refrigerator of any Capacity/ Make/Model/ Type, Removal of Blockage by Flushing out, Brazing (as required) and making the System Fully Leakeage Proof, Replacing Unserviceable Compressor & Other Parts and Re-assembling after necessary repaired and Testing, complete all as specified and as directed. NOTE :- (a) Any Minor Items as well as Any Repair Works involves to Make the Refrigerator Functional, even if not notified by JE/ Engineer-in-Charge, the same will be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items here-in-after.
M&L Bimetal Switch (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator of any Capacity/ Make/ Model/ Type and Testing including Taking down/ out Unserviceable Bimetal Switch, complete all as specified and as directed. MAKE : GODREJ/ KELVINATOR/ LG/ SAMSUNG/ VIDEOCON/ VOLTAS
M&L Capacitor 1.5/2.0 mfd (as per existing One/ as approved) for Refrigerator Refrigerator of any Capacity/ Make/ Model/ Type and Testing including Taking down/ out Unserviceable Capacitor, complete all as specified and as directed. MAKE : GODREJ/ KELVINATOR/ LG/ SAMSUNG/ VIDEOCON/ VOLTAS
M&L Compressor Sealed Unit (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator of any Capacity/ Make/ Model/ Type and Testing including Taking down/ out Unserviceable Compressor, complete all as specified and as directed. MAKE : GODREJ/ KELVINATOR/ LG/ SAMSUNG/ VIDEOCON/ VOLTAS
M&L Cooling Coil (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator of any Capacity/ Make/ Model/ Type and Testing including Taking down/out Unserviceable Cooling Coil, complete all as specified and as directed. MAKE : GODREJ/ KELVINATOR/ LG/ SAMSUNG/ VIDEOCON/ VOLTAS
M&L Fan Motor with Blade for Evoporator Unit (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator of any Capacity/ Make/ Model/ Type and Testing including Taking down/ out Unserviceable Fan Motor, complete all as specified and as directed. MAKE : GODREJ/ KELVINATOR/ LG/ SAMSUNG/ VIDEOCON/ VOLTAS
M&L Over Load Protection Relay (as per existing One/ as approved) suitable for Refrigerator of any Capacity/ Make/ Model/ Type and Testing including Taking down/ out Unserviceable Over Load Protection Relay, complete all as specified and and as directed. MAKE : GODREJ/ KELVINATOR/ LG/ SAMSUNG/ VIDEOCON/ VOLTAS
S&F Thermostate Switch (as per existing One/ as approved) to match the Same Model & Capacity for Refrigerator of any Capacity/ Make/ Model/ Type and Testing including Taking down/ out Unserviceable Thermostate Switch, complete all as specified and as directed. MAKE : ANNAPURNA/ DENFOS/ INDFOS/ RENTRAL
M&L Complete Servicing Refrigerator of any Capacity/ Make/ Model/ Type in Situ by Cleaning Condenser Unit, Cooling Coil and Internal Parts, and Testing, complete all as specified and as directed. NOTE : Any Minor Items if required on Servicing to make the Refrigerator Functional, the same will be provided by the Contractor without any Extra Cost to the Department.
Supply & Charging of Refrigerant F-22 to Refrigerator of any Capacity/ Make/ Model/ Type after Cleaning of Condenser Unit, Evoporator Unit, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof and Vaccuming and Testing, complete all as specified and as directed.
REPAIRS & MAINT TO WATER COOLERS & DEEP FREEZERS
M&L Opening Defective Water Cooler of any Capacity/ Make/ Model/ Type for Checking/ Repairing, Removal of Blockage by Flushing Out, Brazing (as required) Suction & Discharge Pipes for Making the System Fully Leakeage Proof, Cleaning thoroughly Cooling Coil to achive Proper Cooling effect, Replacing unserviceable Compressor & Other Parts and Re-assembling after necessary repaired & Testing, complete all as specified and as directed. NOTE :- (a) Any Minor Items as well as Any Repair Works involves to Make the Water Cooler Functional, even if not notified by JE/ Engineer-in-Charge, the same will be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items here-in-after.
M&L Blower Motor with Blade, Single Phase, 1325 RPM, 230/240 Volt, 50 Hz (as per existing One/ as approved) for Water Cooler of any description, Providing necessary Connections & Testing including Taking down/ out Unserviceable Blower Motor, complete all as specified and as directed.
M&L Compressor Sealed Unit (as per existing One/ as approved), Single Phase for Water Cooler 40/80 Litre Capacity, Providing necessary Connections & Testing includ-ing Taking down/out Unserviceable Compressor, complete all as specified and as directe MAKE : BLUE STAR/ EMERSON/ HITACHI/ KIRLOSKAR/ TECUMESH/ TOSIBA
M&L Compressor Sealed Unit (as per existing One/ as approved), Single Phase for Water Cooler 60/120 Litre Capacity, Providing necessary Connections & Testing including Taking down/ out Unserviceable Compressor, complete all as specified and as directed. MAKE : BLUE STAR/ EMERSON/ HITACHI/ KIRLOSKAR/ TECUMESH/ TOSIBA
M&L Over Load Protector to Compressor Sealed Unit (as per existing One/ as approved) for Water Cooler of any description, Providing necessary Connections and Testing including Taking down/ out Unserviceable Over Load Protector, complete all as specified and as directed. MAKE : HITACHI/ SHRIRAM/ TECHEMSHAH
M&L Running Capacitor 10 mfd (as per existing One/ as approved) 400/ 440 Volt AC for Water Cooler of any description, Providing necessary Connections & Testing including Taking down/ out Unserviceable Running Capacitor, complete all as specified and as directed. MAKE : SARDA/ UNIVERSAL/ USHA
M&L Thermostatic Switch (as per Existing One/ as approved) for Water Cooler of any description, Providing necessary Connections & Testing including Taking down/ out Unserviceable Thermostatic Switch, complete all as specified and as directed. MAKE : ANNAPURNA/ DENFOS/ INDFOS/ RENTRAL
M&L Complete Servicing of Water Cooler of any Capacity/ Make/ Type in Situ by Cleaning Condenser Unit, Fan Motor & Blade, Base Plate including Repairs to Storage Tank, complete all as specified and as directed. NOTE : Any Minor Items required on Servicing to make the Water Cooler Functional, the same will be provided by the Contractor without any Extra Cost to the Department.
Supply & Charging of Refrigerant F-22 to Water Cooler of any Capacity/Make/ Model/ Type after Cleaning of Condenser Unit, Cooling Coil, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof and Vaccuming, and Testing, complete all as specified and as directed.
M&L Opening Defective Deep Freezer 200/400 Litre Capacity of any Make/ Model/Type Removal of Blockage by Flushing Out, Brazing (as required) Suction & Discharge Pipes for Making the System Fully Leakeage Proof, Cleaning thoroughly Cooling Coil to achive Proper Cooling effect, Checking of Electronic Circuit of Machine, Changing of Wiring with proper Size PVC insulated Copper Wires, Replacing unserviceable Compressor & Other Parts and Re-assembling after necessary repaired & Testing, complete all as specified and as directed. NOTE :- (a) Any Minor Items as well as Any Repair Works involves to Make the Deep Freezer Functional, even if not notified by JE/ Engineer-in-Charge, the same will be carried out by the Contractor without any Extra Cost to the Department. (b) Compressor & Other Parts and Charging of Refrigerent as required will be Measured and Paid separately as 'S&F'/ 'M&L' and 'Supply & Charging' under relevant Items here-in-after.
M&L Compressor Sealed Unit (as per existing One/ as approved) suitable for Deep Freezer 310/320 Litre Capacity of any Make/ Type Providing necessary Connections & Testing including Taking down/ out Unserviceable Compressor, complete all as specified and as directed. MAKE : EMERSON/ HITACHI/ KIRLOSKAR/ SHRIRAM/ TECHEMSHAH
M&L Fan Motor with Blade, Single Phase, 230 Volt AC, 50 Hz (as per existing One/ as approved) to match the Same Model & Capacity for Deep Freezer 200/400 Litre Capacity of any Make/ Type and Testing including Taking out Unserviceable Fan Motor with Blade, complete all as specified and as directed.
S&F Relay (as per existing One/ as approved) to match the Same Model & Capacity for Deep Freezer 200/400 Litre Capacity of any Make/ Type and Testing including Taking down/ out Unserviceable Relay, complete all as specified and as directed.
S&F Thermostate Switch (as per existing One/ as approved) tto match the Same Model & Capacity for Deep Freezer 200/400 Litre Capacity of any Make/ Type and Testing including Taking down/ out Unserviceable Thermostate Switch, complete all as specified and as directed. MAKE : ANNAPURNA/ DENFOS/ INDFOS/ RENTRAL
M&L Complete Servicing Deep Freezer 200/400 Litre Capacity of any Make/ Type in Situ by Cleaning Condenser Unit, Fan Motor with Blade, Base Plate, etc. Complete Testing for Proper Functioning, achiving Proper Cooling effect including necessary Repairs to Deep Freezer and Testing, complete all as specified and as directed. NOTE : Any Minor Items if required on Servicing to make the Deep Freezer Functional, the same will be provided by the Contractor without any Extra Cost to the Department.
Supply & Charging of Refrigerant F-22 to Deep Freezer 200/400 Litre Capacity of any Make/ Type after Cleaning of Condenser Unit, Evoporator Unit, Brazing to Stop the Leakage of Suction/ Discharge Tubes (as required) and Making the System Fully Leakeage Proof and Vaccuming and Testing, complete all as specified and as directed.
REPAIRS & MAINT TO VOLTAGE STABILIZERS & MISC ITEMS
M&L Dismantling Voltage Stabilizer 2.0/ 3.0 KVA Capacity, Single Phase, 240 Volt AC, Repairing as required, Replacing burnt Transformer Copper wounded, Electronic Circuit, Relays, Indicator Light, Voltmeter, Display, Switch & Socket, etc. to provide Correct Stabilised 130-240 Voltage, Re-assembling the Voltage Stabilizer after Repaired, Re-installed & Testing, complete all as specified and as directed. NOTE : Cost of All Materials & Labour Elements required for Making the Stabilizer Functional, will deemed to be included in the Quoted Unit Rate.
M&L Dismantling Voltage Stabilizer 4.0/ 5.0 KVA Capacity, Single Phase, 240 Volt AC, Repairing as required, Replacing burnt Transformer Copper wounded, Electronic Circuit, Relays, Indicator Light, Voltmeter, Display, Switch & Socket, etc. to provide Correct Stabilised 130-240 Voltage, Re-assembling the Voltage Stabilizer after Repaired, Re-installed & Testing, complete all as specified and as directed. NOTE : Cost of All Materials & Labour Elements required for Making the Stabilizer Functional, will deemed to be included in the Quoted Unit Rate.
S&F PVC insulated Copper Flexible Cable 1.5 Sqmm 3 Core, multi-stranded and Providing Electric connection including Taking down/out Unserviceable Flexible Cable of any description, complete all as specified and as directed.
S&F Plug Top 6 Amp, 3 Pin, ISI marked, 230 Volt AC and Connecting up including Taking down/out Unserviceable Plug Top, complete all as specified and as directed.
S&F Plug Top 16 Amp, 3 Pin, ISI marked, 230 Volt AC and Connecting up including Taking down/out Unserviceable Plug Top, complete all as specified and as directed.
S&F Factory made Sheet Metal Enclosure, Single Pole & Neutral, with 2 Pin & Earth Plug Top and Socket 20 Amp rating, IP-43 Protected with and including MCB 20 Amp, Single Pole (1 No.) and Connecting up including Taking down/out Unserviceable Sheet Metal Enclosure, complete all as specified and as directed.
S&F Factory Made Sheet Metal Enclosure, Single Pole & Neutral, with 2 Pin & Earth Plug Top and Socket 20 Amp rating, IP-43 Protected with and including MCB 20 Amp, Double Pole (1 No.) and Connecting up including Taking down/out Unserviceable Sheet Metal Enclosure, complete all as specified and as directed.
S&F Cast Iron Bib Tap 15mm bore (dia), Plug type, screwed for Iron Pipe including Taking down/out Unserviceable Bib Tap, complete all as specified and as directed.
M&L Push Cock 15mm bore (dia) Brass Chromium plated, high pressure, screwed down for Socket/ Unions or GI Pipe including Taking down/ out Unserviceable Push Cock, complete all as specified and as directed. MAKE : JAINSON/ NIXON or equivalent as approved by GE
S&F PTMT Angle Stop Valve 15mm bore (dia) having Minimum Weight 90 Grams, any Colour, high pressure,screwed for Iron Pipe and fixed including Taking down/out Unserviceable Angle Stop Valve, complete all as specified and as directed.
S&F PVC Connection in Inlet, 15mm bore (dia) and 450mm in length with PTMT Nuts suitable for Cold/Hot Water including Taking down/out Unserviceable PVC Connection, complete all as specified and as directed.
M&L PVC Float Valve Assembly 15mm bore (dia) comprising Valve Assembly, Aluminum Rod, PVC Ball, suitable Water Cooler/ Desert Cooler including Taking out/ down Unserviceable Float Valve Assembly, complete all as specified and as directed.
M/S Build Tech
ms singh construction
M/S RK Trading
M/s HALDER ENTERPRISE
STANDARD ELECTRIC WINDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .