Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC 5574 A KANSHI RAM MARKET NEW CHANDRAWAL KAMLA NAGAR DELHI 07 | L1 | Accepted-AOC The firm is the L1 bidder | |
| 2 | L2₹2.2 L+₹3,783 (1.73%)Rejected-Finance C 6 9 YAMUNA VIHAR DELHI 53 | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance The firm is not the L1 bidder |
Tender Value
₹2.2 L
EMD Value
₹4,400
Closing Date
23 Feb 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER EM II
MUNICIPAL CORPORATION OF DELHI OFFICE OF THE EXECUTIVE ENGINEER EM II LODHI ROAD AUTO WORKSHOP UNDER SEWA NAGAR FLYOVER NEW DELHI 110003
EE EM II/ 2023-24/ 8
2024_SDMC_186904_12
EE EM II/ 2023-24/ 8
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
30 days
Lodhi Road
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹4,400
14 Mar 2024
17 Feb 2024
23 Feb 2024
17 Feb 2024
23 Feb 2024
17 Feb 2024
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable on surface, medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group C
Wiring for light point/ power point with 2x4 sqmm FR PVC insulated copper conductor single core in surface/ recessed PVC conduit alongwith 1 no 4 sqmm FR PVC insulated copper conductor S/ C cable for loop earthing as required for following locations
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/ 6 & 15/ 16 amps socket outlet and 15/ 16 amps piano type switch, connection, painting etc. as required.
Wiring for circuit/ sub main with 2x2.5 sqmm FR PVC insulated copper conductor single core in surface/ recessed PVC conduit alongwith 1 no 2.5 sqmm FR PVC insulated copper conductor S/ C cable for loop earthing as required for following locations
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 5/ 6 amps socket outlet and 15/ 16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing 2+6/ 8 way double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
Supply and fixing 63 amps rating, double pole, 240 volt, isolator in the existing MCB DB complete with connection, testing and commissioning etc, as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required
Supplying and fixing 6 amps to 32 amps rating, single pole ,240/ 415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply of AC ceiling fan energy saver type complete with down rod of standard length (30cm), canopy, blades without regulator of following size: 1200 mm sweep.
Installation, testing & commissioning of ceiling fan i/ c wiring the down rod of standard length (upto 30 cm) with 1.5 sqmm FR PVC insulated copper conductor single core cable etc as required.
Supply of hanging clamp for ceiling fan.
S and F of electronic fan regulator 1200/ 1400mm sweep a.c. ceiling fan on existing switch board as reqd
Supply of 15 inch (380mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters, blades etc as reqd.
Installation of exhaust fan upto 450 mm sweep ,in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
S/ I/ T/ C of LED Tube Type luminiare 20 Watt rating complete with polycarbonate housing Batten integrated electronic driver prewired with high efficient LEDs with the following: (a) Total System Wattage 20 Watt +/ - 5%. (b) Luminous Efficieny lumens/ watt >= 95 (c ) Power Factor>= 0.95
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (18) 5/ 6 amps switch
15/ 16 amps switch
3 pin 5/ 6 amp socket outlet
6 pin 5/ 6 and 15/ 16 amp socket outlet
P&F of On load change over switch four pole in existing cubicle panel with advance neutral conforming to IS: 13947 (part-3) including drilling hole in cubicle panel making connections etc complete as required of 250 A
P&F of four pole MCCB having rating capacity of 250 A and breaking capacity of 36 kA (Icu) with thermomagnetic release and terminal spreaders in existing cubicle panel, making connections etc as required
Providing of 600 mm sweep pedestal fan complete with blades, base plate, supporting rod, jaal workable on 220/ 240 volts AC supply etc as reqd.
Supply of LED street light fitting 70 W complete in all respect, colour temperature 3000K, IP66 protection, toughened glass cover, Aluminium housing.
Supply of LED street light fitting 150 W flood light luninaire complete in all respect, colour temperature 3000K, IP66 protection, toughened glass cover, Aluminium housing.
Supply of 4x 50 Sqmm size of XLPE insulated PVC sheathed Al. Conductor armoured cable 1.1 KV grade confirming to IS-7098.
Supply of 3.5x 95 Sqmm size of XLPE insulated PVC sheathed Al. Conductor armoured cable 1.1 KV grade confirming to IS-7098. (Generator to panel)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 50 sq. mm (35 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.3.5X 95 sq. mm (45 mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required (a) 63mm dia (OD-63mm ID -51mm nominal).
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq mm and Up to 95 sq. mm
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Sai Interprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .