Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.9 LQualified Make: microtek
Model: 5 KVA UPS 00 GAYATRIPURAM GAYATRIPURAM KASYA ROAD DEORIA UTTAR PRADESH 274001 | DEORIA | UTTAR PRADESH | 274001 | Make: microtek
Model: 5 KVA UPS | L1 | Qualified | |
| 2 | L2₹3.7 L+₹85,200 (29.5%)Qualified Make: NUMERIC
Model: Numeric 5kVA Onfiniti FMI G T ROAD AMRITSAR PUNJAB 143105 | AMRITSAR | PUNJAB | 143105 | Make: NUMERIC
Model: Numeric 5kVA Onfiniti FMI | L2 | Qualified | |
| 3 | L3₹3.8 L+₹86,200 (29.8%)Qualified Make: LUMINOUS
Model: LUMINOUS LD6000 A 76 SURENDRA NAGAR ISMAILGANJ FAIZABAD ROAD LUCKNOW UTTAR PRADESH 226016 UDYAM UP 50 0018139 | LUCKNOW | UTTAR PRADESH | 226016 | Make: LUMINOUS
Model: LUMINOUS LD6000 | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 May 2018, 7:00 pmClosed
Online UPS Experience with Gov. Required 1 Year (s) Online UPS ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0kva Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT-PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz singlephase230v-1sine wave50hz Backup time (Minutes) 120 120 Minimum VAH (VAH) 24000 Warranty for UPS (Years) 3 1
2
3
4
5 Movable trolly for Batteries Without With
Without
Without trollery but with rack Warranty for battery 1 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for With With
Without 1/5 input and out put Paralleling kit for synchronising With With
Without Installation and Commissioning Yes N/A CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) </= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes N/A Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of Yes N/A 2/5 (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes N/A Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. R-81001295 N/A Type Test Certificate date JAN-2017 N/A Name of Lab BIS DELHI
STQC-ETDC (GOVT. OF INDIA) N/A Address of Lab DELHI N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashish Dhingra N 110010
Army Cyber Group
Signals Enclave
Rao Tula Ram Marg
New Delhi 2 30 EMD Required No ePBG Required No 3/5
14302
GEM/2018/B/2028
Online UPS
30 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Experience with Gov. Required 1 Year (s) Online UPS ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0kva Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz singlephase230v-1sine wave50hz Backup time (Minutes) 120 120 Minimum VAH (VAH) 24000 Warranty for UPS (Years) 3 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries Without With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 1 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for With With | - | - | - |
| Without 1/5 input and out put Paralleling kit for synchronising With With | - | - | - |
| Without Installation and Commissioning Yes N/A CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) </= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes N/A Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of Yes N/A 2/5 (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes N/A Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. R-81001295 N/A Type Test Certificate date JAN-2017 N/A Name of Lab BIS DELHI | - | - | - |
| STQC-ETDC (GOVT. OF INDIA) N/A Address of Lab DELHI N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashish Dhingra N 110010 | - | - | - |
| Army Cyber Group | - | - | - |
| Signals Enclave | - | - | - |
| Rao Tula Ram Marg | - | - | - |
| New Delhi 2 30 EMD Required No ePBG Required No 3/5 | - | - | - |
Exempted
7 May 2018
19 Apr 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_14302.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .