Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30 LAccepted-AOC ARIYALUR | TAMIL NADU | 608901 | L1 | Accepted-AOC Low | |
| 2 | L2₹3.5 Cr+₹3.1 Cr (929.1%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
12 Mar 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Officer
Pothanur Town Panchayat office
CONSTRUCTION OF INFILTRATION WELL AT RIVER BANK OF CAUVERY AT POTHANUR HEAD WORKS IN POTHANUR TP Namakkal Dist
2024_DTP_445841_1
Roc 13-2024
Open Tender
Civil Works - Water Works
Works
180 days
Pothanur town Panchayat Office
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹30,000
19 Sept 2024
9 Mar 2024
12 Mar 2024
9 Mar 2024
12 Mar 2024
9 Mar 2024
9 Mar 2024 - 12 Mar 2024
Amount
Earthwork excavation above water level in light or sandy or clay soils for infiltration well of 4.50m Dia (Internal) including levelling the site and as directed by the departmental officers Infitration well
Connecting Main Line
Reinforced cement concrete 1:1.5:3 mix using 20mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing, laying, finishing and curing etc complete. up to 1.50m Below GL
0 to 4.5m above GL (infiltration well)
Sinking well of 4.50m internal dia below water level including all incidental charges in loose / sandy soil using special tools and plants such as air compressor helmet etc. including bailing out water completeas per standard specifications. First depth of 2.0m
second depth of 2.0m
Third depth of 2.0m
Fourth depth of 2.0m
Fifth depth of 2.0m
Porous cement concrete 1:4 (One cement, four aggregate) by using 20mm machine crushed HBG (no sand to be used) for the steining wall of infiltration well/Mat portion etc. excluding cost of reinforcement and fabricating centering, shuttering and strutting but including cost of all materials,mixing placing in position lifting finishing and curing etc complete. ( 0 to 4.5m above GL)
Centering for soffits of RCC members or plane surface including shuttering, strutting to the centering and providing supports etc. complete for the following members using MS sheets of size 90x60cm and 'BG' 10 gauge stiffened with welded M.S. angles of size 25x25x3mm laid over silver oak (country wood) joists of size 10 x 6.5 cm spaced at about 90cm C/C and casurina props of 10 to 13 cm dia (spaced at 75cm C/C) for various heights and as directed by the departmental Officers. The centering should be removed after the specified striping time of the concrete as per IS-456/1978. For Plane Surface ( Infitration well )
For Curved Surface ( Infitration well )
Supplying, cutting, bending, tying, fabricating and placing in position of steel rods for all RCC works including cost of steel and binding wire etc. The steel should conform to the relevant IS specification and supplied with test certificate (Fe.415 grade as per IS specification No.1786/1985 and as amended from time to time) for delivery at site of work including loading, freight, unloading, stacking, transit insurance charges, taxes etc. complete. Infitration well
Supply, delivery and fixing in position 50mm thick RCC (1:1.5:3) manhole cover slab of size 0.60 x 0.60 with necessary reinforcement and MS angle of size 50mm x 50mm x 6mm thick fixed alround the edges of the slab complete.
Supply, delivery and fixing of CI steps in position at 30 cm center to center in staggered manner and as per IS 5455-1969 of Pattern II
Providing Ventilating arrangement by fixing in position 110mm OD pipe 6KSC with PVC cowl and 1.0m length (218.50+67.70)
Providing confirmatory bores to ascertain sand depth and locating well site before commencing the work.
Cement Painting two coats with approved Cement Paint over one coat of Primaring coat of Cement Paint over new cement plastered wall surface, ceiling and other new surface including cleaning, preparing the surface, curing, scaffolding charges etc., complete complying with standard specifications and as directed by the departmental officers. Infitration well
Providing dewatering diesel pump set 7.50HP-2nos. for yield test
Boring, providing and installing Bored cast-in-situ reinforced cement Concrete pile of specified diametre and length below the pile cap in cement concrete 1 :1.5:3 ( 1 cement, 1 .5 Coarse sand,& 3 graded stone aggregate of 20 mm nominal size) to carry a safe working load not less than specified, excluding the cost of steel reinforcement than specified, excluding the cost of steel reinforcement but including Bentonite solution machinery charges labour chargres etc.,all complete.
Earthwork excavation and depositing on bank for foundation, within initial lead of 10m and initial lift of 2m including shoring, strutting and baling out water wherever necessary and all other incidental works, as directed by the departmental Officers in the following classification of soil.Hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small sized boulders and hard gravelly soil Connecting Main Line
Writing the details of scheme Emblem on the outside wall using approved quality colour paint with Standard Specifications including the cost of paint, brush, scaffolding etc., complete.
Refilling the sides of foundation with excavated earth (other than sand) in layers of 15cm thick,watered well rammed and consolidated etc. complete complying with standard specification removing and spreading the surplus earth at the places shown . Connecting Main Line
Lowering of DI pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD officers 150 mm DI Pipes
Jointing DI S/S pipes and specials with rubber gaskets (tyton joints) including cost of lubricants, testing to the required pressure with water (including cost of jinting materials) 150 mm DI Pipes K9
Supply delivery of DI pipes and specials as per standard specifications and as directed by Departmental Officers 150 mm DUCTILE IRON SOCKET/SPIGOT PIPES FOR CLASS K9 AS PER IS 8329/2000
Supply delivery of 50MM dia GI pipes (Medium) as per standard specifications and as directed by Departmental Officers
Drilling of borewells of size 3 " to 4 " dia using hand bore set for insertion of 50 mm GI Pipes and as directed by Departmental Officers
Plugging the G.I pipes with P.C.C 1: 1.5:3 using 20mm HBG Stone excluding cost of centering
Supply, delivery and fixing of 150 mm size clamp sets for fixing of connecting main with GI pipes and as directed by Departmental officers
Supply and delivery of Open well submersible pumpsets and accessories capable of discharging the following lpm and head due to all causes suitable for installation in head works with dynamically balanced water lubricated bronze impellers,stainless steel shaft (TST.400) protected from sand and other suspended particles.This pump should be provided with non-return valve to avoid water hammering with ISI mark and as per IS 14220 460 lpm x 57m head. (Say 500lpmx75m)
Supply and delivery of 3 phase panel board with two level guard and Auto start 10 HP-star delta starter
Supply and delivery of 150mm pressure gauge with stop cock and copper piping arrangements fixed with teakwood board in the pumphouse to be mounted on wall. The maximum rating should be of 1.5 times the shut off head of the pump.
Laying the above cable between EB transformer to panel Board
Jointing the above cable from EB transformer to panel Board includidng allied civil works etc. complete as per I.E. Rules.
Supply and delivery of 1.1 KV grade, 3 core PVC insulated, PVC sheathed, Coppe flat type conductor cable With ISI marking conforming to IS 694/1990 of reputed make to be laid connecting Motor and starter. 6 sq.mm cable for 10 HP motor
Laying 6 sq.mm copper cable from panel board to motor through starter through PVC conduits including allied civil works etc. complete as per I.E. rules
Jointing 6 sq.mm copper cable including cost of lugs, cables, glands etc. wjerever necessary as per I.E. rules 6 sq.mm cable for 10 HP motor
Supply and delivery of PVC 6Ksc pipes and specials as per relevant Isfor cable encasing 50mm PVC pipe
Labour charges for erection of 10HP openwell submersible pumpset including fixing of delivery pipes to the required length with valves, pressure gauges and erection of panel board consisting of switches, starter, voltmeter, ammeter, capacitor, single phasing 10 HP Submersible pumpset
Supply and delivery of the 80 mmof GI medium pipe Galvanised mild steel tubes screwed in both ends, conforming to IS 1239/part I/90 for pipes threading, socketted on one end and the other end protected with plastic thread protector, in random length of 4
Supply and delivery at site of following sizes of GI specials with ISI marking for jointing with GI Pipes including loading, freight unloading, stacking, insurance and all taxes etc., complete and as directed by the Departmental officers 150 mm x 80 mm Taper
80 mm GI Bend
80 mm GI tee
80 mm GM Gate Valve
80 mm GM Non Return valve
80 mm GI Flange
80 mm MS Clamp
80 mm GI Coupling
80 mm GI Union
80 MM heavy Hex Nipple
Supply and delivery of Cast Iron double flanged sluice valves of 80mm size with cap of class PNI with non raising high tensile brass spindle valve operating in anticlockwise direction with IS marking suitable for use in water supply main including loading
Cutting the following sizes of GI pipes true to its axis, filing and finishing the ends etc, complete and as directed by the Departmental officersn including loading
Labour charges for threading the following sizes of GI Pipes wherever necessary
Jointing the CI Double flanged pipes and specials with rubber insertion to the required specifications with MS bolts and nuts complete and testing to the required pressure with water (including cost of jointing mateirlas) for depth upto 2m
Chinnusamy P
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .