Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.3 LAccepted-AOC | L1 | Accepted-AOC Lowest rate | |
| 2 | L2₹76.5 L+₹2.3 L (3.06%)Rejected-Finance PLOT NO 1235 JLPL SECTOR 82 SAS NAGAR MOHALI MOHALI PUNJAB 160055 | S A S NAGAR | PUNJAB | 160055 | L2 | Rejected-Finance Above rate | |
| 3 | L3₹76.7 L+₹2.5 L (3.32%)Rejected-Finance SCO 117 118 FF CABIN NO 104 SECTOR 17B CHANDIGARH | L3 | Rejected-Finance Above rate | |
| 4 | L4₹86.9 L+₹12.6 L (17.0%)Rejected-Finance | L4 | Rejected-Finance Above rate |
Tender Value
₹88 L
EMD Value
₹1.8 L
Closing Date
15 Jan 2020, 5:00 pmClosed
Executive Engineer
Markfed Plot No. 4 Sector 35B Chandigarh
Centralized Air conditioning HVAC of Markfed Head Office building plot No 4 Sector 35B Chandigarh
2019_Coop_42310_10
NO.EE/FED/19/4371 dt 20.12.19
Open Tender
Electrical Works
Lump-sum
60 days
Sector 35B Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
Markfed
₹1.8 L
Chandigarh
19 Apr 2021
24 Dec 2019
17 Jan 2020
24 Dec 2019
15 Jan 2020
24 Dec 2019
3 Jan 2020
Amount
NS Items : (Part-A)
VRV/VRF Outdoor Unit
VRV/VRF
Supply, installation, testing and commissioning of Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by multiple scroll/DC Twin rotary compressor controlled by individual inverters for each compressor complete with indoor and outdoor units with individual wired and wireless /wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, control cabling and fittings etc. as per details given in specifications and having following items. The outdoor units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply.
Outdoor Units
Supply, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient multiple scroll/ DC twin rotary compressors(OEM manufactured) fully inverter controlled (individual inverter for each compressor) i.e. changes its speed in accordance to the variation in cooling loads, special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and capacity as mentioned below including all hardware & accessories & including full charging of R-410A refrigerant gas complete i/c powder coating complete as per specifications. The units should be with necessary weather protection coating. The coating should be done before bringing the units to site. Outdoor units shall be provided with MS stand of suitable size duly painted with corrosion resistant paint suitable for outdoor application.
All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control.
All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor.
The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical of the ODU.
Each ODU wheather used individually or used to make module should have multiple compressors.
All Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. A draft Format of the same need to be submitted along with in the Technical Bid.
Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP at 100% Load to be 3.8 at AHRI Conditions
Insurance of Units ,Unloading at site, placement of Oudoor Units on the foundation,stands, co-ordination during execution, rendering necessary guidance for execution, supervision, testing,commissioning and startup of above mentioned VRF/VRV by OEM.
Note: The civil foundations reqd shall be made by the tenderer
48 HP (as per suitable module/Combination)
20 HP (as per suitable module/Combination)
VRV/VRF Indoor Units
Supply, installation, testing and commissioning of below mentioned capacity Ductable/Casettes type Indoor air conditioners complete with fan and fan motor, inter connecting it with refrigerant piping, insulation , cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing.
The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kg/cm2. Indoor units shall have a wired remote control. They shall be operated through from the wired remote control from the respective locations. Corded Remotes are seperately payable.
The Drain pump as a standard accessory and shall be included in the price of units
Four Way Cassette Acs along with its Grill Panel
Providing and fixing of Corded remote controls with cord for Cassette Acs
Providing and fixing of Cordless remote controls with cord for Cassette Acs
Centralized Controller
Providing, Fixing & Running Centralized Controller for all VRV/VRF Indoor /Outdoor Units and Must Be Compatible with BMS
Refnet / T / Y- Joints
Supply Installation, Testing and commissioning of fittings Ref Net / T / Y-joints/Connecting joints of ODU's etc as per specifications.
Refrigerant Piping
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF/VRV system etc. complete in all respects duly insulated with closed cell nitrile rubber (Class 'O') as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the HVAC consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the system.
41.3 mm OD (insulation = 19mm)
38.2 mm OD (insulation = 19mm)
34.9 mm OD (insulation = 19mm)
31.8 mm OD (insulation = 19mm)
28.6 mm OD (insulation = 19mm)
25.4 mm OD (insulation = 19mm)
22.2 mm OD (insulation = 19mm)
19.1 mm OD (insulation = 13 mm)
15.9 mm OD (insulation = 13 mm)
12.7 mm OD (insulation = 13 mm)
9.5 mm OD (insulation = 13mm)
6.4 mm OD (insulation = 13 mm)
Condensate Drain Piping:
SITC UPVC/HARD PVC pipes of various sizes for condensed water drainage from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as approved by architect/consultant/Client
All necessary civil works like cutting & chasing of walls/floor/ glass etc. and make them good thereof
40 MM DIA with 6mm Nitrile Rubber Insulation (Class -O)
32 MM DIA with 6mm Nitrile Rubber Insulation (Class -O)
25 MM DIA with 6mm Nitrile Rubber Insulation (Class -O)
Power & Control Works
Supplying and laying of following 1100 volt grade PVC insulated sheathed copper conductor armoured cables in trenches, on walls clamped to wall with suitable clamps, saddles, and fixing bolts, or laying in ground including cost of digging brick and sand protection, and including jointing / connecting / terminating, testing and commissioning :
4C x 25Sq. mm Copper (armoured) Conductor
4C x 16Sq. mm Copper (armoured) Conductor
4C x 10Sq. mm Copper (armoured) Conductor
4C x 6Sq. mm Copper (armoured) Conductor
For Indoor Units,
Providing & fixing of electrical supply Flexible Cabling of 4 core x 2.5 sq. mm copper in suitable conduits between IDU & Room DB
Control Cabling
Providing & fixing control cum transmission wiring/ Control Cabling of 2 core x 1.5sq. mm copper in suitable conduits between indoor and out door unit & indoor unit & its remote controller.
Providing & fixing control cum transmission wiring/ Control Cabling of 4 core x 1.5sq. mm copper in for between IDU & Room DB.etc.
MCB DB Box
SITC of MCB DB Box with MCB DP 'c' curve of 6-16 Amps as per rating of the Indoor unit of respective VRV/VRF unit with all accessories like ,etc. complete in all respect .
Main Electrical Panel (CPRI Approved)
SITC of Electrical Main Panel weather Proof outdoor Type Powder Coated Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make sheet having thickness 2.0 mm for load bearing surfaces & 1.6 mm Non bearing surfaces as per following specifications complete in all respect
INCOMING SUPPLY : MCCB 500-630 Amps,4 Pole 50 KA Micro Processor Based release Adjustable type (suitable atleast Ambient Temprtature 50 degrees) The MCCB shall have ICS=100%ICU etc : 1 No.
Multi Fuction VAF/VIF Meter (96mmX96mm Size) ,Indication Lamps LED Type RYB, Control MCB SP for Control (3 Nos each),CT's 250/5 (3 Nos) etc.
OUTGOING FEEDERS : 100-125 A , 3Pole MCCB,36KA with Thermal magenetic release adjustable type. The MCCB shall be double break & the ICS=100% ICU (for VRV/VRF unit 48HP X 2Nos ,20HPX 3Nos,): 5 Nos + 2 Spare
along with required Spreader Links with phase Barriers , Rotary Mechanism,Auto phase Sequence relay,ATS etc.
Contactors of equivalent rating as per the machine combination (with auto phase sequence system for proper operation of the VRV/VRF) Each set of machine VRV/VRF (herein meaning 48HP/20HP section of VRV/VRF) shall have its own independent auto phase sequence corrector with accessories as required and for each ODU of VRV/VRF unit shall have ELCB/ELR,Single phase preventer etc. with all acessories as per the combination of the VRV/VRF machines
32-63 A or Suitable,3Pole MCCB,25KA with Thermal magenetic release adjustable type along with ROM & accessories. The MCCB shall be double break & the ICS=100% ICU-(10 nos +1 Spare) outgoings to the DB panels for Indoor unit supply herein menaing total MCCB feeders as 11 nos)
BUS BAR : Aluminium Bus Bar 800 A TPN Electrolite grade E91 having Suitable size Cross Section for Phase,Neutral& Current Carrying Capacity 0.8 A/Sqmm
Hardware ( PVC Cahnnels/MCB Channels/Fibre- Glass Gaskets/Sleevs/nuts/bolt/washers/cooling fans etc Including complete wiring,thimbles etc.
Unloading at site, placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel.
MCB DB Panels
SITC of MCB Distribution Panel Wall Mounted Type Powder Coated Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make sheet having thickness 2.0 mm for load bearing surfaces & 1.6 mm Non bearing surfaces as per following specifications complete in all respect
MCB DB Box consisisting of Incomer TPN MCB 32/40 AMP 'C' Curve 10 KA with outgoing MCB SP 6-16 AMP 'C' Curve 10kA :16 Nos (to each indoor machine DB BOX)
MCB DB Box consisisting of Incomer TPN MCB 32/40 AMP 'C' Curve 10 KA with outgoing MCB SP 6-16 AMP 'C' Curve 10kA :13 Nos (to each indoor machine DB BOX)
MCB DB Box consisisting of Incomer TPN MCB 32/40 AMP 'C' Curve 10 KA with outgoing MCB SP 6-16 AMP 'C' Curve 10kA :10 Nos (to each indoor machine DB BOX)
Hardware ( PVC Cahnnels/MCB Channels/Fibre- Glass Gaskets/Sleevs/nuts/bolt/washers/cooling fans etc Including complete wiring,thimbles etc.
Unloading at site, placement of Panel , co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panels.
Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. complete in all respects as per ISI specifications.
GI 8 SWG wire earthing complete with thimbles etc
GI Strip 50mm wide x 6 mm thick earthing complete with thimbles/nut bolt etc.
Civil Work for making Holes,Chiesling,Cutting walls etc.( related to AC work only) and make them good thereof
Bidder Name
Amount
NOVA ENVIRO ENGINEERS
ACE COOLING SOLUTIONS
modern cooling solution
SMD Solutions
NOVA ENVIRO ENGINEERS
ACE COOLING SOLUTIONS
modern cooling solution
NOVA ENVIRO ENGINEERS
SMD Solutions
modern cooling solution
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .