| 4 | Not Admitted-Fee/PreQual/Technical A 101 JHULELAL APARTMENT ROAD NO 44 PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical C 36 DUGGAL COLONY KHANPUR DEVLI ROAD DELHI 110062 | SOUTH | DELHI | 110062 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹14.9 L
EMD Value
₹29,779
Closing Date
13 Apr 2021, 2:30 pmClosed
Executive Engineer(E)
DAMB, 9 Institutional Area, Pankha Road, Janak Puri, New Delhi-110058
AMC And Operation of all type Electrical fixtures, pumps sets, High Mast include whole net work of electrical panels feeder pillars at NGM Najafgarh
2021_DAMB_202461_1
F.No. 25(1)/2020/24/DAMB/Engg/
Open Tender
Electrical Works
Works
365 days
NGM Najafgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹29,779
7 May 2021
31 Mar 2021
13 Apr 2021
31 Mar 2021
13 Apr 2021
31 Mar 2021
Amount
Providing qualified staff and T&P required for a period of one year for repair , maintenance and round the clock operation of all type of electrical fixtures, pumps, D G Sets, High Mast ,electrical panels , feeder pillars , cables network and other accessories installed at APMC Najafgarh. The minor items i.e. PVC tape, Nut bolt, washers, dhoti, grease etc for execution work shall be provided by the contractors free of cost. The minimum staff to be deployed by the contractor shall be as under:- (i) Wireman Gd-1 - 01 No (ii) DG/Pump Operators - 02 Nos (iii) Khallasi -01 Nos
Comprehensive AMC of following installations i/c repair/replacement of all major/ minor parts shall be provided by the contractor.
Booster pumps capacity of 20 H P with starter control panels - 02 Nos
Submersible pump capacity of 7.5 HP & 5 HP with starter control panels -02 No
Vacuum pumps capacity of 5 HP with starter control panels -01 No
Booster pumps capacity of 7.5 HP with starter control panels - 02 Nos
Vacuum pumps capacity of 1 HP with starter control panels -01 No
Taking out of defective submersible pump set from bore well along with pipes/ cable etc from the depth of 30 meter approx as required
Installation of repaired submersible pump set from bore well along with pipes/ cable etc from the depth of 30 meter approx as required
Annual Maintenance Contract of 25 KVA capacity Diesel Generator set complete with supplying & replacement of parts in Engine & Alternator i/c B Check one number with lubricating oil, gasket, water separator, water hose pipe sets, de-scaling of radiator, cu-washer etc. as per scope of work as and when required for a period of one year.
Annual Maintenance Contract of 62.5 KVA capacity Diesel Generator set complete with supplying & replacement of parts in Engine & Alternator i/c B Check one number with lubricating oil, gasket, water separator, water hose pipe sets, de-scaling of radiator, cu-washer etc. as per scope of work as and when required for a period of one year.
Supply of following genuine & approved ISI marked material as and when required during the contract period of one year. The price should be including all taxes and cartage
Supply of LED 36 watts, T-8,4 feet Tube light
Supply of LED 18 watts, T-8,2 feet Tube light
Condenser 2.5 MFD
6 A to 32 A ratings, SP MCB, "B" series, 10 kA breaking capacity
32 A ratings, DP MCB, "B" series,, 10 kA breaking capacity
MCB DP 40 Amp
MCB TPN 63 Amp
MCCB, 4 pole, 125A, 25 kA
MCCB, 4 pole, 250A, 35 kA
SP 5/6 amp, one way switch, piano type ISI Marked
SP 15/16 amp, one way switch, piano type ISI Marked
3 Pin 5/6 amp, socket outlet, piano type ISI Marked
3 Pin 15/16 amp, socket outlet, piano type ISI Marked
Electronic fan regulator
Bell push piano type ISI Marked
PVC insulated PVC sheathed XLPE aluminum conductor armored cable of 2X16 Sq mm
PVC insulated PVC sheathed XLPE aluminum conductor armored cable of 4X25 Sq mm
PVC insulated PVC sheathed XLPE aluminum conductor armored cable of 4X35 Sq mm
PVC insulated PVC sheathed XLPE aluminum conductor armored cable of 4X50 Sq mm
1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
Aluminum lugs of Size 16 Sq mm
Aluminum lugs of Size 25 Sq mm
Aluminum lugs of Size 35 Sq mm
Aluminum lugs of Size 50 Sq mm
3 Pin 6 amp, plug top ISI Marked
3 Pin1 6 amp, plug top ISI Marked
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size Up to 35 sq. mm on wall surface(clamped with 1mm thick saddle) as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of size above 35 sq mm and up to 95 sq. mm on wall surface(clamped with 1mm thick saddle) as required.
Dismantling & re-election, commissioning of the 20 meter high mast lighting tower on the existing RCC foundation with the assistance of suitable size/capacity crane complete fixing/repairing/replacement work.
Erection of metallic pole of length above 10 meter and up to 12 meter in cement concrete 1:3:6 ( 1 cement: 3 coarse sand:6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required.
Dismantling of pole/street light standard/strut embedded in brick ballast foundation etc as required.
Rajesh Electrical Works
SRS ENGINEERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .