Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.9 LAccepted-AOC | 1 | Accepted-AOC Lowest and reasonable | |
| 2 | 2₹7.9 L+₹1.3 L (19.2%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | 2 | Rejected-Finance Other than lowest | |
| 3 | 3₹8.3 L+₹1.7 L (25.5%)Rejected-Finance | 3 | Rejected-Finance Other than lowest |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
2 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mhow
HQ CWE Mhow , Cantt Mhow 453441
PROVISION OF STORE ROOM FOR HQ CWE MHOW UNDER GE MCTE MHOW
2022_MES_534759_1
CWE(MHOW)/05(T) OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
HQ CWE Mhow
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (MCTE) Mhow
₹12,000
Yes
16 Sept 2022
30 Jun 2022
4 Aug 2022
30 Jun 2022
2 Aug 2022
15 Jul 2022
60 days
Amount
M & L Surface excavation not exceeding 30 cm deep and averaging 15cm deep and gett-ing out in hard / dense soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/dense soil complete all as specified and directed..
Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 (nominal Mix) type B-1 using 20mm graded stone aggregate in foundations, footing, plinth beams, bases for columns and mass concrete complete all as specified and directed. (reinforcement to be measured separately).
M&L for reinforced cement concrete 1:2:4 (nominal Mix) type B-1 using 20mm graded stone aggregate in columns ,pillars, piers, post and strut etc complete all as specified and directed. (reinforcement to be measured separately).
M&L for reinforced cement concrete 1:2:4 (nominal Mix) type B-1 using 20mm graded stone aggregate in beams, ,cantilever, etc complete all as specified and directed. (reinforcement to be measured separately).
M & L for 25mm thick PCC (1:2:4), type B0 (using 12.5mm graded stone aggregate) as in damp damp proof course complete all as specified and directed
M&L for reinforced cement concrete 1:2:4 (nominal Mix) type B-1 using 20mm graded stone aggregate in slabs supported on walls ,beams and column in floors, roofs, landings, balconies, canopies, deck slab and in shelves and the like etc complete all as specified and directed. (reinforcement to be measured separately).
M&L for reinforced cement concrete 1:2:4 (nominal Mix) type B-1 using 20mm graded stone aggregate in chajja supported on walls ,beams and column in floors, roofs, landings, balconies, canopies, deck slab and in shelves and the like etc complete all as specified and directed. (reinforcement to be measured separately).
Material and labour mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
Supply and fix mild steel TMT bars 8mm dia as in stirrups, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia complete all as specified and directed.
Use and waste of form work to sides of concrete foundation, footings, bases column, raft and raft beams, plinth beams etc. rough finished surface of concrete. complete all as specified and directed.
Use and waste of form work to sides of pillars, posts, piers and column etc rough finished surfaces of concrete complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beam , beam haunching, lintels ,cantilevers etc.,.complete all as specified and directed.
Use and wast of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not Exc 200mm Wide complete all as specified and directed.
Use and wast of form work to chullah hoods, chajjas, troughts and similar items including edges complete all as specified and directed.
Material and labour for brick work with sub class 'B' modular bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and directed.
Material and labour for brick work with sub class 'B' modular bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M & L for rendering 15 mm thick in two layers of 10+5mm in CM 1:4 mixed with integral water proofing as per manufacturer instruction and finish the surface even and smooth (without using extra cement) for external wall complete all as specificed and directed.Note :- WPC shall be measured and paid separately.
M & L for rendering 15 mm thick in CM 1:6 mixed with integral water proofing admixture as per manufacturer instruction and finish the surface even and smooth (without using extra cement) for internal wall complete all as specificed and directed. Note :- WPC Shall be measured and paid separately.
M & L for rendering 10 mm thick in CM 1:4 (interior ceiling surface) and finish the surface even and smooth (without using extra cement) for ceiling complete all as specificed and directed.
M&L rendering 20mm thick in CM 1:4 on fair faces of brick/concrete surfaces,with integral water proofing admixture as per manufacturer instruction and finish the surface even and smooth (without using extra cement) (NOTE: WPC shall be measared seperately complete all as specified and directed).
Supply only Integral water proofing compound complete all as specified and directed.
M & L for preparation of new surface of plastered of walls and applying two coat of distemper oil emulsion incl priming the surface and incl one coat of wall putty all as directed by Engr-in-Charge complete all as specified and directed.
M & L for preparation of newly plastered surface for celling and applying two coat of distemper oil emulsion incl priming the surface and incl one coat of celling putty all as directed by Engr-in-Charge complete all as specified and directed.
M & L for preparing of newly plastered surface on exterior wall and applying two coat of premium Acrylic smooth exterior paint and including priming coat of exterior primer incl one coat of putty Birla White and scrapping the surface till smoth finish complete all as specified and directed by Engr-in-Charge complete all as specified and directed.
S & F pressed steel door frame for single door, size 105 x 60 x1.5mm with one rebates incl necessary fixing lugs, hinges, lock strike plate, holdfast (size 25mm x 3mm) of length 30cm) etc, complete all as specified and directed by Engr-in-Charge complete all as specified and directed.
M & L PCC 1:2:4 type BO(12.5mm graded) aggregate for filling in pressed steel door framed complete all as specified and directed.
M & L for painting to steel surface of any description over 10cm width or girth with 2 coats of synthetic enamel paint to steel surface complete all as specified and directed.
S & F 35mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and directed.
S & F 150mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F 300mm length, aluminium alloy, anodised, sliding door bolt with hasp, stapie (bolt type0 and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sections or coat aluminium alloy complete all as specified and directed.
S&F 150mm size extruded aluminium alloy handles, fabricated type complete all as specified and directed.
M&L for preparation of new wooden surface over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed
Providing and fixing fixed louvers fabricated from Roll formed sections made of galvanized Steel colour coated/powder coated (base Steel as per IS 513 ‘D’ quality, galvanized as per IS 277 with zinc of 120 grams/Sqm) with thickness of 0.58mm coated sections to be primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick, section for external frame 33 x 58 mm, glass holding flanges made of polypropylene, sections are to be cut to length, mitre joined with corner bracket. The above frames should be fixed to the concrete/masonry walls by means of self expanding screws. Make :NCL Ventilator or equivalent all as specified and directed.
Providing and fixing of double rebate openable/fixed windows made of galvanized steel colour coated/powder coated (base steel as per IS 513 of “D" quality, galvanized as per IS 277 with zinc of 120 grams/sqm) with total thickness of coating 0.58 microns, primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, outer frame section 72 x 55 mm, centre mullion section 72 x 50 mm, shutter section 47 x 20 mm,fly mesh section 40 x 20 mm and the fixed glass beading section 12 x 12 mm, outer frame and mullions shall consists rebate for glazed shutter, fly mesh and 20 mm provision for guard bars/grills, the sections cut to length mitre joined with corner bracket, centre mullions fixed with mullion cap, stay, handles, latch, 2 Nos of heavy duty stainless steel pivot hinges per shutter and panelled with 5mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade), fitted using EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing windows in the concrete/masonry wall by means of self-expanding screws, including 10mm Square bars welded to 6x12mm flat at a distance 150mm c/c (pitch) etc. complete as per the direction of Engineer in Charge. Make NCL Window or equivalent
S & F for mild steel, framed work such as grills, grating etc with end of bars shouldered and / riveted of forged into spikes; framed guard bars; and similar work conforming to Fe.290.Gde-E-165. complete all as specified and directed .
Material and labour for broken stone (granite/basalt/trap) hardcore of gauge not exceeding 63mm deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rolled/rammed to a true Surface complete all as specified and as directed.
M & L for 100mm thick PCC 1:4:8 type D2 using 40mm graded aggregate as in sub base of floor complete all as specified and directed
M & L for 50mm thick PCC 1:2:4 type B-2 using 20mm graded aggregate as in top layer of floor to be finished even and smooth with using extra cement complete all as specified and directed
M&L Machine cut mirror polished kota stone slab flooring with rounded edge 20-25 mm thick over and includingcement screed bed (1:6) 15mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.(Note : Steps landing single piece kota stone and edge rounding complete ) complete all as specified and directed.
M&L Machine cut kota stone skirting 20-25 mm thick in riser of steps skirting, dado, and pillar over and including 10mm thick backing coat in cement mortar in (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding and mirror polishing complete all as specified and directed.
M&L 16 to 18mm thick granite (of any type) work (table rubbed and polished and exposed visible edge moudling/rounding) in step, jambs, pillars, window cills, cooking platforms and like in 15mm thick cement mortar (1:4) including pointing in white cement 91:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Returning , filling including spreading levelling , watering and well ramming in layers n.exc 25cm complete all as specificed and directed.
Removing excavated material exc.1.50 Km but n.exc. 5 Km and depositing where directed at a level n.exc.1.5 m above the starting point etc complete all as specified and as directed. (Soils)
M&L for 75mm thick cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection finished even and fair incl cutting joints and filling with bitumen and sand mixture complete all as specified and directed.
M&L for treating the top surface of the filled earth @ 5.00 ltr of emulision per Sqm of surface area with ATT complete all as specified and directed.
M&L for treating the soil along with internal periphery of room at the rate of 2.25 litre of emulsion per metre of surface area with ATT complete all as specified and directed.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for 10mm thick screed bed on concrete surface in CM(1:3) finished even and smooth without using extra cement complete all as specified and directed.
M & L Water proofing treatment on non approach/non accessible roof surface (Horizontal/ Vertical) in following sequences through manufacturer /authorised applicator of the manufacture complete all as specified and directed complete :- (i) Properly cleaning and drying cement surface (ii) Applying one coat of oxidized bitumen based solvent primer @ 0.3Kg/Sqm (III) Laying 3mm thick APP modified water proofing membrance with 100mm overlap sealed and bonded to the surfaces by torchon Method. (iv) Applying Two coats of bituminous alumunium paint @ 200 gram/Sqm (minimum).(Note:- Make/brands of APP membrance modified with all associated items shall be of any one of SUPER THERMOLAY OF STP LTD OR TORH SHIELD P-3160 OR PIDILITE INDUSTRIES LTD OR HYPER PLAS PLOLYSTER or equivalent approved make complete all as specified and directed.
M & L for conceated Point wiring with PVC insulated and unsheathed single core FR cable of size 1.5 sqmm stranded copper conductor , 1100 volt grade, drawn into and including PVC rigid conduit not less than 20mm dia, medium grade, ISI marked with and including 1.5 Sqmm un sheathed green colour standed copper conductor FRLS cable for continuous earth wire and including sunken pressed steel concealed terminal boxes of suitable size made out of 1:2mm thick sheet covered with 2.6mm thick white hylam sheet cover of suitable size for mounting switches/sockets/fan regulators or modular flush box for mounting modular switches/sockets/regulators etc including cutting chasing in wall and making good disturbed surface with existing colour complete all as specified & directed for the following:-
One light/fan point controlled by one switch.
One socket out let 2/3 pin 5amp, multipurpose on same board with other switches.
One switch/socket out let point 2/3 pin 5 amp multipurpose on independent board.
Ditto All as per item No 53 here in before but FRLS cable 2.5 sqmm stranded copper conductor cable for switch/socket outlet 5 pin, 15 Amps multipurpose controlled with 2.5 sqmm copper conductor FR cable as continuous earth wire of green colour on independent board.
Supply and fix in repair/replacement, switch piano flush type, 5 Amps, 230V AC, single pole, one way complete.
Supply and fix in repair/replacement, switch piano flush type, 15 Amps, 230V AC, single pole, one way complete.
Supply and fix in repair/replacement, socket out let multipurpose suitable for 2/3 pin 5 amp flush type complete.
Supply and fix in repair/replacement, socket out let 2 in 1, multipurpose suitable for 3 pin 5/15 amp flush type complete.
Supply and fix in repair, angle/batton type holder insulated body in white colour complete.
Supply and fix/replacement, celling rose, 3 phase, polycorbonate isolated body for surface type, three terminals complete.
S&F LED lamp of 7 W (B-22 Base) 6500K complete all as directed.
S&F for modular step type fan regulator 120 watt 2 modular suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
Supply and fix in repairs LED trim line PC batten type LED light 1x20 Watt, without LED tube rod, pre wired for LED tube, and 100 lumen/watt, product No LCTLN-20-CDL complete with all accessories duly connection with three core flexible copper cable and duly fixed on two Nos PVC square boxes complete all as specified and directed .
Supply and fix in repairsretrofit LED tube light T-8 type, 1x20/21 Watt, 6000K with extruded al heat sink for each efficient heat dissipation complete all as specified and directed .
Supply and fixing celling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. Five star rate with brushless direct current motor (BLDC) complete.
S&F replacement of exhaust fan, steel body AC single phase 230 volt of size 380mm sweep complete with blade, frame and louvers all as specified and directed incl making/alteration of hole wherever necessary making good disturbed surface, painting to match with existing surfaces.
Supply and fix in repairs double door SPN DBs 8 ways of power coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din ral complete.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 AMP, in the MCB DB complete with connection testing and commissioning all as specified and directed by Engr-in-Charge.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection testing and commissioning all as specified and directed by Engr-in-Charge.
M&L for Sub main wiring in repair with two runs of single core FR PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia including one run of PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly in conceated wiring system by cutting of wall and making good distrurbrd surface of wall all as specified and directed NOTE:- Two runs of 4.00 sqmm cable, one run of 2.50 sqmm cable and one run of PVC conduit will be measured as.
Supply & Laying XLPE insulated, armoured, electric cable of size 10 sqmm 2 core with aluminium conductor, 1100 volts grade, laid in trenches, fixed on poles/walls or passing through pipe including provision of necessary lugs and glands & making necessary connection including taking down old unservicable cable of any core complete aa as specified and dircted, (Make:- Havells/Polycab/Finolex/RR kabel Ltd.)
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable / fixing poles, stays etc and getting out complete all as specified and directed
Returning , filling including spreading levelling , watering and well ramming in layers n.exc 25 cm each complete all as specified and directed
Removing excavated material n. exc 50m and deposited where directed at a level n exc 1.5m above the starting point , complete all as specified & directed.
Supply and laying 50mm bore Galvanised iron pipe "light grade" with all fittings for passing of cabes fixed to pole/wall/laid under floor or roads including all fixing accessories complete for protection of cable complete all as specified and directed.
Material and labour for approved river sand cushioning for under ground cable in trenches 8 cm before laying and 15cm after laying of cable and punned thickness of sand shall be measured and paid for 18 cm only after punned /consolidated thickness complete all as specified and directed
M & L brick protection cover over cable sub class 'B' laid dry over cable (length of brick shall be laid across the length of cable) complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate 600mm x 600mm x 6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised MS strip 32mm X 6 mm as earthing strip by means of bolts, nuts, check nut and washers of galvanised iron or steel at all joints as shown in Electrical Plate No-3 of SSR Part I including excavation and earth work in any type of soil, GI pipe 15 mm dia light grade protection pipe, chorcoal filling, common salt, PCC 1:3:6 type C-1 using 20 mm graded stone aggregate in chamber and RCC precast cover 60mm thick (1:2:4) type B-1 using 20mm dia graded crushed stone aggregate, reinforced with 8mm to steel bars @ 75 mm c/c both ways with MS handle 12mm dia, GI funnel and wire mesh, 20mm dia GI pipe medium grade for watering and connected to earth Test point including testing complete all as specified and directed. (Note :- Earth protection pipe & earthing strip upto and including 7.5m length is deemed included in unit rate quoted by the contractor
sunway associates
KAILASH CHANDRA KHANDELWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .