| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAdmitted-Finance | ₹7.8 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s SHEERAZ ENGINEERING WORKS L1 |
|---|---|---|---|---|
| 1.00 | Supply,Installation, Testing and commissioning of 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, indoor, with O/C, E/F relays (Preferably ABB/REF615) (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port with necessary circuitry for the SCADA/DMS MFT's CMRs etc as per the existing setup of SCADA in vogue in the department .(The new panel should be in alignment with the existing panel set) CT Ratio 600-300/5A | 1 | No | 5,80,000 ₹5.8 L |
| 2.00 | Providing and laying of 11 kV 3-Core XLPE 300 mm² armoured, FRLS (one spare cable) to be laid through HDPE pipe suitable for 300sqmm cable including cost of HDPE pipe | 60 | Meter | 2,300 ₹1.4 L |
| 3.00 | Supply,installation,testing and commissioning of 11 kV Indoor Heat Shrinkable Cable Termination Kits 300 sqmm 3-core | 1 | Set | 2,000 ₹2,000 |
| 4.00 | Supply,installation,testing and commissioning of 11 kV outdoor Heat Shrinkable Cable Termination Kits 300 sqmm 3-core | 1 | Set | 2,000 ₹2,000 |
| 5.00 | Supply,installation,testing, and commissioning of 11 kV Isolator, double break,3-pole, 630Amp, horizontal mounting Type, with Earth Switch | 1 | Set | 35,000 ₹35,000 |
| 6.00 | Providing and fixing of Earthing for Isolator, etc Complete by GI Pipe 40 mm 3 mtr long through GI strip 25x3 mm | 3 | No | 1,500 ₹4,500 |
| 7.00 | Proviidng,Laying,stringing ,tensioning and binding of 100sqmm ACSR conductor as per REC construction standard (with latest amendments if any). | 100 | Meter | 70 ₹7,000 |
| 8.00 | Supply,installation,testing and commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting | 3 | No | 450 ₹1,350 |
| 9.00 | Supply,installation,testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm. | 9 | No | 150 ₹1,350 |
| 10.00 | Labour charges for adjusting existing Cables for making way for new Cables and removing of debris and foilage in the existing trench and dismantling and adjusting existing panels in the Receiving Station (LS). | 1 | Job | 4,000 ₹4,000 |
Updated dates
Tender Value
₹7.9 L
EMD Value
₹15,829
Closing Date
19 Feb 2026, 4:30 pmClosed
Executive Engineer, STD-II, Rajbagh,Srinagar
Office of the Executive Engineer, STD-II, Rajbagh
Segregation of F4 Rajabgh by way of Creation of 11KV Feeder from 2x10MVA ,33 11KV Receiving Station Jawahar Nagar.
2026_PDD_299675_1
eNIT No STD-II / 59 of 2025-26 Dated 01-01-2026
Open Tender
Electrical Works
Srinagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Executive Engineer, STD-II, Rajbagh,Srinagar
₹15,829
18 Mar 2026
2 Jan 2026
20 Feb 2026
2 Jan 2026
19 Feb 2026
2 Jan 2026
Supply,Installation, Testing and commissioning of 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, indoor, with O/C, E/F relays (Preferably ABB/REF615) (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port with necessary circuitry for the SCADA/DMS MFT's CMRs etc as per the existing setup of SCADA in vogue in the department .(The new panel should be in alignment with the existing panel set) CT Ratio 600-300/5A
Providing and laying of 11 kV 3-Core XLPE 300 mm² armoured, FRLS (one spare cable) to be laid through HDPE pipe suitable for 300sqmm cable including cost of HDPE pipe
Supply,installation,testing and commissioning of 11 kV Indoor Heat Shrinkable Cable Termination Kits 300 sqmm 3-core
Supply,installation,testing and commissioning of 11 kV outdoor Heat Shrinkable Cable Termination Kits 300 sqmm 3-core
Supply,installation,testing, and commissioning of 11 kV Isolator, double break,3-pole, 630Amp, horizontal mounting Type, with Earth Switch
Providing and fixing of Earthing for Isolator, etc Complete by GI Pipe 40 mm 3 mtr long through GI strip 25x3 mm
Proviidng,Laying,stringing ,tensioning and binding of 100sqmm ACSR conductor as per REC construction standard (with latest amendments if any).
Supply,installation,testing and commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting
Supply,installation,testing and commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm.
Labour charges for adjusting existing Cables for making way for new Cables and removing of debris and foilage in the existing trench and dismantling and adjusting existing panels in the Receiving Station (LS).
Providing and fixing of Gavanized Nuts & Bolts of sorts as per site requirements.
NOTE: ALL WORKS SHALL BE CARRIED OUT STRICTLY AS PER REC STANDARDS WITH LATEST AMENDMENTS THERE OF.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tendernotice_2.pdf
PDF • 1.59 MB
BOQ_972317.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid