| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAdmitted-Finance | ₹1.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.7 Cr+₹3.4 L (2.01%)Admitted-Finance | ₹1.7 Cr+₹3.4 L (2.01%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
| Sl No | Description | Qty | Unit | K D Aher Building Systems Pvt Ltd L2 | S.V ASSOCIATES L1 |
|---|---|---|---|---|---|
| 1.00 | Supply and Application chemical based waterproofing coating with Kemperol 1K of Kemper Systems Germany or approved equivalent for Parapet Wall and Critical Areas at elevation about 18"-00" and 51"-00" from ground level etc. complete as per clause-1 of technical specifications and as directed by Engineer-in-charge. | 1,100 | Sq.m | 3,450 ₹37,95,000 | 3,330 ₹36,63,000 Lowest |
| 2.00 | Supply and Application chemical based waterproofing coating with Kemperol V210 of Kemper Systems Germany or approved equivalent at roof terrace etc. complete as per clause-2 of technical specifications and as directed by Engineer-in-charge. | 300 | Sq.m | 5,500 ₹16,50,000 | 5,400 ₹16,20,000 Lowest |
| 3.00 | Removing of existing bitumen/chemical based waterproofing treatment from terrace chajjas, parapets etc, and disposal within 50m etc. complete as per clause-3 of technical specifications and as directed by Engineer-in-charge | 500 | Sq.m | 270 ₹1,35,000 | 225 ₹1,12,500 Lowest |
| 4.00 | Surface cleaning of existing exterior RCC fascia cladded walls of a height upto 16.00 mtrs elevation by applying of water jet as per clause-4 of technical specifications and as directed by Engineer-in-charge | 9,300 | Sq.m | 20 ₹1,86,000 | 18 ₹1,67,400 Lowest |
| 5.00 | Providing structural Repairs in Old Damaged concrete structures / surfaces with approved Polymer as per clause-5 of technical specifications and as directed by Engineer-in-charge | 900 | Ltrs | 850 ₹7,65,000 | 801 ₹7,20,900 Lowest |
| 6.00 | Providing and painting walls with approved shade of high build protective , elastomeric water proof exterior grade paint of approved make of required shade, minimium dry film thickness of 250 microns acheived in two or more coats as per clause-6 of technical specifications and as directed by Engineer-in-charge | 9,300 | Sq.m | 525 ₹48,82,500 Lowest | 540 ₹50,22,000 |
| 7.00 | Providing and fixing double tubular scaffolding system using H-frames with cup lock type on the exterior side up to seven story height made with 40 mm dia M.S.tube 1.5m centre to centre horizontal and vertical tube joining with cup and lock system etc. complete as per clause-7 of technical specifications and as directed by Engineer-in-charge | 8,000 | Sq.m | 220 ₹17,60,000 | 180 ₹14,40,000 Lowest |
| 8.00 | Providing and applying Anticorrosive treatment to exposed Reinforcement portion or steel surface with one coat of alkaline rust converter "feovert/rusticede or equivalent etc. complete as per clause-8 of technical specifications and as directed by Engineer-in-charge | 120 | Sq.m | 550 ₹66,000 | 333 ₹39,960 Lowest |
| 9.00 | Providing SFMC Micro concrete using 100% for strengthening of structural members including form work, mixing, pouring, curing as per manufacturer specifications and as directed by the Engineer-in-charge | 8,500 | Kg | 99 ₹8,41,500 | 90 ₹7,65,000 Lowest |
| 10.00 | Providing , centering ,shuttering Form work using PVC film faced plywood to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels | 20 | Sq.m | 630 ₹12,600 | 540 ₹10,800 Lowest |
Tender Value
₹1.6 Cr
EMD Value
₹3.1 L
Closing Date
12 Mar 2024, 6:00 pmClosed
Chief Engineer and Head HLUESS
HLUESS office RLG BARC TROMBAY MUMBAI 85
Special repairs, chemical based waterproofing and protective coating works
2024_BARC_793010_1
BARC/HUES/RC-253/35/2023-24
Open Tender
Civil Works
Item Rate
548 days
RLG Building, BARC Trombay Mumbai
As per NIT criteria
3 documents required · 3 mandatory
₹0
₹3.1 L
Office of Head HLUESS RLG building BARC Mumbai 85
24 Apr 2024
1 Feb 2024
18 Mar 2024
1 Feb 2024
12 Mar 2024
1 Feb 2024
1 Feb 2024 - 21 Feb 2024
23 Feb 2024
Amount
Supply and Application chemical based waterproofing coating with Kemperol 1K of Kemper Systems Germany or approved equivalent for Parapet Wall and Critical Areas at elevation about 18"-00" and 51"-00" from ground level etc. complete as per clause-1 of technical specifications and as directed by Engineer-in-charge.
Supply and Application chemical based waterproofing coating with Kemperol V210 of Kemper Systems Germany or approved equivalent at roof terrace etc. complete as per clause-2 of technical specifications and as directed by Engineer-in-charge.
Removing of existing bitumen/chemical based waterproofing treatment from terrace chajjas, parapets etc, and disposal within 50m etc. complete as per clause-3 of technical specifications and as directed by Engineer-in-charge
Surface cleaning of existing exterior RCC fascia cladded walls of a height upto 16.00 mtrs elevation by applying of water jet as per clause-4 of technical specifications and as directed by Engineer-in-charge
Providing structural Repairs in Old Damaged concrete structures / surfaces with approved Polymer as per clause-5 of technical specifications and as directed by Engineer-in-charge
Providing and painting walls with approved shade of high build protective , elastomeric water proof exterior grade paint of approved make of required shade, minimium dry film thickness of 250 microns acheived in two or more coats as per clause-6 of technical specifications and as directed by Engineer-in-charge
Providing and fixing double tubular scaffolding system using H-frames with cup lock type on the exterior side up to seven story height made with 40 mm dia M.S.tube 1.5m centre to centre horizontal and vertical tube joining with cup and lock system etc. complete as per clause-7 of technical specifications and as directed by Engineer-in-charge
Providing and applying Anticorrosive treatment to exposed Reinforcement portion or steel surface with one coat of alkaline rust converter "feovert/rusticede or equivalent etc. complete as per clause-8 of technical specifications and as directed by Engineer-in-charge
Providing SFMC Micro concrete using 100% for strengthening of structural members including form work, mixing, pouring, curing as per manufacturer specifications and as directed by the Engineer-in-charge
Providing , centering ,shuttering Form work using PVC film faced plywood to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels
Providing 20 mm thick plastering using Ready mix external plastering compound of approved make for external faces of brick work / concrete surfaces including preparation of the surface ,curing, cleaning, scaffolding upto 10 metres height complete.all as per specifications including forming drip moulds wherever necessary and as directed by the Engineer-in-charge.
Providing and applying Colour FRP LINING to existing circular duct as per Clause-12 of Technical Specification and as directed by the Engineer-in-Charge.
Lead charges for lead Exceeding 2 KM but not exceeding 3 KM, by mechanical transport including loading, unloading, stacking / levelling etc.
K D Aher Building Systems Pvt Ltd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .