Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.3 L+₹2.5 L (19.6%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹15.8 L+₹3.0 L (23.6%)Rejected-Finance MOHANPUR PT LL HOUSE NO 00 CITY TOWN SILCHAR P O KATIRAIL P S KATIGORAH DISTRICT CACHAR PIN 788804 | CACHAR | ASSAM | 788804 | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹33,320
Closing Date
5 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR/MAINTANCE OF TOILET OF GROUP 1 AND GROUP 5 AT CSD DEPOT NARANGI UNDER GE GUWAHATI
2022_MES_562186_1
GE/GUW/63/8279 OF 2022-23
Open Tender
Civil Works
Buy
120 days
GUWAHATI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE GUWAHATI
₹33,320
Yes
14 Jan 2023
9 Nov 2022
7 Dec 2022
9 Nov 2022
5 Dec 2022
23 Nov 2022
9 Nov 2022 - 16 Nov 2022
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing and removing debrires from the site complete all as directed.
Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each complete all as directed.
Taking down chowkat with shutter without taking off shutter from the frame exc 1.5 Sqm n.exc 4 Sqm each complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as directed.
Demoliation of cement concrete of any description and in any position not otherwise specifically provided for complete all as directed
Taking down 20mm bore steel tubing and connections, complete all as specified and directed
Taking down 25mm bore steel tubing and connections, complete all as specified and directed
M&L 25mm thick PCC (1:2:4) type B-0 (using 12.2mm graded aggtregate) as in levelling course in flooring finishing cement concrete surface even & fair complete all as specified and as directed.
M&L Non skid coloured tiles 7 to 8 mm thick (square/rectangular) polished, area of each tiles exc. 0.18 sqm but not exc 0.38 sqm in floors etc set and jointed :in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and as directed.
M&L Coloured glazed ceramic tiles 350x250x7mm/300 x 450 x 7 mm thick in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing with CM (1:4) complete all as specified and as directed.
S&F Factory made single extruded WPC (wood polymer composite) solid door/window/ ceosetory windows & other frame/ chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (suspension grade) calcium carbonate and natural fibers (wood powder / rice husk/ wheat husk) and non toxis additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screw withdrawal strength of 2200 N (face) & 1100 N (Edge), mimimum compressessive strength of 58 N/sqmm, modulus of elasticity 900 N/sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS holdfast/ lugs/SS dash fasteners of required dia and length complete as per mauufactueres instruction and as directed Note: MS holdfast /lugs or SS dash fasteners shall be paid for separatel).
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, with particle board core, complete as per specification & drawing as specified in SSR Part I, Section 8 and as directed.
S&F 100 mm size Butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed.
S&F 100mm long Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed.
S&F 150mm Aluminium handles, cast type, anodised complete all as specified and as directed.
S&F Powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed Note:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium ventilators any type including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, along with standard locking arrangements, handles, tower bolts etc as required. complete all as specified and directed Note:- (i) Labour charges for fixing of glass/wire guage/aluminum grills is inclusive in the unit rate quoted. Glass/Wire Guage/aluminum grills shall be measured and paid seperately at supply only rates (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed
Supply only 4mm thick frosted one sife sheet glass, ordinary quality fixed with Aluminum frame work n. exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for 15mm thick rendering with cement mortar (1:4) on fair faces of brick work in two layers (10mm & 5mm)seperately mixed with water proofing compound in top layer as per manufacturer's instructions and finishing the surface even and fair without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L Rendering 10 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and fair complete all as specified and as directed.
M&L for Rendering 5 mm thick on concrete surfaces as in ceiling in cement mortar 1:3 for finished even and fair complete all as specified and as directed.
M&L prepration of new plastered surfaces of wall applying two coat of oil emulsion distemper over wall care putty to obtained smoothness of plastered surfaces(minimum thickness 1mm) including one priming coat complete all as specified and as directed.
M&L prepration of new plastered surfaces of ceiling applying two coat of oil emulsion distemper over wall care putty to obtained smoothness of plastered surfaces(minimum thickness 1mm) including one priming coat complete all as specified and as directed.
M&L preparation of new surface of walls and and applying two coats of exterior acrylic emulsion paint (1st quality) over a coat of alkali resistant primer over complete all as specified and directed
Taking out existing APP membrane including screed bed and removing debries outside the permises complete all as specified and as directed
M&L Claening the RCC slab surfaces including sides upto 300mm high by wire brushes , raking and cleaning of construction joints if any and Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and as directed.
M&L Cement concrete type B0, (1:2:4) (using 12.5 mm graded crushed stone aggregate) as in roof padding, roof kerbs or mud stops, rounded or chamfered on edges for roof surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L 15mm thick cement mortar plaster (1:4) on green concrete roof surfaces faces mixed with and including liquid water proofing componud as per manufacturers instruction, finishing the surface fair and even without using extra cement complete all as specified and as directed.
M&L water proofing treatment to flat roofs and edges, applying 3mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.60 Kgs per Sqm reinforced with non-woven polyester febric weight not less than 150gms per Sqm over a coat of bituminous primer @ 0.3Kg/Sqm, after necessary cleaning the surfaces. Polymeric membrane shall be taken to a height of 30cm(minimum) and than inserted inside the groove of parapet wall and shall be finished by a membrane flashing, complete all as specified and as directed. Note : (a) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (b) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction. (c) Applying two coats of Solar reflective bituminious Aluminium paint of approved brand to be provided over the APP membrane as per manufacturers instructions.
S&F 20mm outer dia. CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including cutting through walls together with all fittings (such as bends, elbow, tees, short pieces, comnnector, backnuts, diminishing pieces, caps, plugs and unoin etc) with clips wall hook plugs, complete all as specified.
S&F 32mm outer dia. CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including cutting through walls together with all fittings (such as bends, elbow, tees, short pieces, comnnector, backnuts, diminishing pieces, caps, plugs and unoin etc) with clips wall hook plugs, complete all as specified.
Disconnecting existing tanks of capacity 250 ltrs and not exc 500 ltrscapacity setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. including writing date of cleaning on tank using stencil in white syntheic paint height not exc 10cm complete all as specified and as directed
S&F Rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) (conforming to IS 12701-1996) multi layer hoisted and fixed in position 500 ltrs capacity complete all as specified in SSR Part I, including writing date of cleaning on tank using stencil in white syntheic paint height not exc 30cm ("DATE OF INSTALLATION: DATE") and necessary dismantling old unserviceable tank complete all as specified and as directed
S&F in repairs 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) complete all as specified and directed.
S&F Vitreous China urinals, half stall pattern, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; complete all as specified and as directed Make-JAQUAR CAT No-URS-WHT-13261 or equivalent as approved by GE from list of approved makes.
S&F curved shaped urinal partition with frosted glass 8mm thick, 900mm height, 450mm wide, complete all as specified and as directed Make-JAQUAR CAT No-JSE-CHR-810UC450X or equivalent as approved by GE from list of approved makes.
S&F Table top basin,size :420x420x150mm including 32mm waste fitting brass, chromium plated with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed including 15mm bore PVC Connection with PTMT nut of length 450 mm complete all as specified and as directed Make of Table top basin-JAQUAR CAT No-JDS-BLM-25911 equivalent as approved by GE from list of approved makes.
S&F 15mm pillar cock with wall flange all as specified and as directed make -JAQUAR CAT NO-KUP-CHR-35001PM or equivalent as approved by GE from list of approved makes.
S&F Reflection looking mirror of 6mm thick fixed to wall with chromium plated brass screws and cup washers all as specified and as directed.
S&F Towel ring roung with round flange complete all as specified and as directed Make -JAQUAR CAT NO-CAN-CHR-1121BN or equivalent as approved by GE from list of approved makes.
S&F Grating doom 125mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including 150mm cement concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate) complete all as specified and as directed.
S&F Wall hung slim flushing cistern low level white colour including PVC flush pipe of required length including 15mm bore PVC Connection with PTMT nut of length 450 mm complete all as specified and directed. Make -JAQUAR CAT NO-JAH-WHT-184NBTL or equivalent as approved by GE from list of approved makes.
S&F 15mm Bib cock with wall flange all as specified and as directed make -JAQUAR CAT NO-KUP-CHR-35037PM or equivalent as approved by GE from list of approved makes.
S&F Rimless single piece-WC with UF soft close slim seat cover , Hinges, Dual flushing cistern fitting,Fixing accessories set and accessories set, Cistern fitting, Size: 385x720x710mm,S trap-300mm all as specified and as directed Make-JAQUAR CAT No-ONS-WHT-10853S300UFSM or equivalent as approved by GE from list of approved makes.
S&F 15mm 2 Way bib cock with wall flange all as specified and as directed make -JAQUAR CAT NO-KUP-CHR-35041PM or equivalent as approved by GE from list of approved makes.
S&F health faucet (ABS Body) with 8mm dia, 1 meter long flexible tube & wall hook all as specified and as directed Make-JAQUAR CAT No-ALD-CHR-565 or equivalent as approved by GE from list of approved makes.
S&F toilet paper holder with stainless steel strap complete all as specified and as directed Make-JAQUAR CAT No-CAN-CHR-1153S or equivalent as approved by GE from list of approved makes.
S&F 15mm angular stop cock with wall flange all as specified and as directed Make -JAQUAR CAT NO-OPP-CHR-15053PM or equivalent as approved by GE from list of approved makes.
S&F 110mm UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings including dismantling existing unserviceable pipe complete all as specified and as directed..
S&F 75mm UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings including dismantling existing unserviceable pipe complete all as specified and as directed..
S&F 110mm dia UPVC (SWR) bends of any radius complete all as specified and as directed.
S&F UPVC (SWR) vent cowl of 110mm dia all as specified and directed.
S&F in repairs UPVC(SWR) gully trap 125x110 mm including jointing with solvent cement all as specified and directed.
M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed.
Surface excavation in soft/loose soil, n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for column & wall foundation, UG Cable /Pipe etc. and getting out in soft/loose soil complete all as specified and directed.
Rolling and consolidating formation surfaces, using hand roller 0.2 to 0.5 tonne complete all as specified and directed.
M&L Hardcore of gauge n exc. 63 mm, Broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in mass concrete, complete all as specified and as directed.
M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed
M&L Rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 for finished surface even and fair without using extra cement complete all as specified and as directed.
M&L providing plain cement concrete type B-1, (1:2:4), (using 20 mm graded stone aggregate), as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed i complete all as specified and directed.
M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in benching benching for and forming branch channel (1/2 round or 3/4 section)complete all as specified and as directed.
M&L TMT Bars 8mm dia, cut to length, bent to shape as required including Cranking, Bending, Hooking Ends and binding with Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed.
M&L Cement concrete type B1, (1:2:4) (using 20mm graded crushed stone aggregate) as in roof kerbs or mud stops, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for 100mm thick PCC (1:3:6) type C2 as in sub base of flooring using 40mm graded stone aggregate finishing cement concrete surface even & fair complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm layers in soft/loose soil complete all as specified and directed.
Removing excavated material (Soil) not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and directed.
M&L for reinforced Precast cement concrete (1:2:4), type B1 (Using 20 mm graded stone aggregate)as in cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar (1:6) complete all as specified and as directed. Note:- Reinfocements will be measured and paid seperately under appropiate item
M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade, laid over 50mm thick sand bed layer complete all as specified and as directed. Note:- Sand bedding shall be measured and paid seperately under appropiate item
Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials from site and making good disturbed surfaces of walls, floors, etc. complete all as directed.
M&L surface point wiring for light/fan points controlled by one, one way switch switch complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LSH (ISI markd) with proper colour coding as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box of appropriate size suitable for modular switch/ fittings concealed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications, complete all as specified and directed. Note:- Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles.
All as per item No 3 here-in-above but for one 6 amps socket out let point on the same board with other switches
S&F LED lights fitting 1x 20Watt, (or nearest next higher wattage) 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&FLED light fitting mirror type with high out put diffuser 2 feet, 10 watt (or nearest next higher wattage) 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F LED light fitting 1X10Watt (or nearest next higher wattage) bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F exhaust fan, steel body AC single Phase. 230Volts of size 300m sweep with, blades, and frame and louvers including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F Modular type switch piano white 6 Amps single pole one way 01 module complete all as specified.
S&F Modular type Socket outlet white 6 Amps 5 pin 2 module complete all as specified and as directed.
S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed.
S&F, Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Single pole & neutral with 200 amps rated bus bar, including blanking plates as required and fixed to wall surfaces complete all as specified and as directed. .
S&F in repair, Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 double door, Single pole & neutral with 200 amps rated bus bar, including blanking plates as required and fixed to wall surfaces complete all as specified and as directed. .
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.all as specified and directed.
S&F MCB, SPN, C Series 240 Volts, 40 Amps 50 HZ, 10KA complete all as specified and as directed.
S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.
M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab (1:2:4) reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and as directed.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed. NOTE : Punned thickness 18cm shall be considered for payment as per para 19.75 of SSR Part-I.
M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M&L 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in cable protection fixed to pole,laid in trenches/road/floor complete all as specified and as directed.
S&F in repair, 50mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, including taking out the old unserviceable 40mm GI pipe complete all as specified and as directed.
S&F in repair, 25mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, including taking out the old unserviceable 20mm GI pipe complete all as specified and as directed.
S&F in repair, 50mm outer diameter, PP-R Gate valves (brass insert) as per requirement of the site, complete all as specified and as directed.
S&F in repair, 25mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
Labour for making horizontal bore hole under road surfaces,upto 150mm bore by trenchless techonology using ultra sounding technoque and necessary machines as required suitable for 0.4mpa working pressure at a depth of not less than 1.00 meters below the road surfaces for passing out pipe complete all as specified and as directed. Note: (i) Work shall be carriede out at night hours only and work to be completed on the same day. (ii) Necessary safety precautions/arrangement for road traffic, boards/signs required to be made by the contractor
U S CONSTRUCTION
M/S Bharat Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .