Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC 42 11 DIPKA PALI ROAD DIPKA DIPKA KORBA CHHATTISGARH 495452 | KORBA | CHHATTISGARH | 495452 | L1 | Accepted-AOC Techno commercially accepted by TC and approved by GM | |
| 2 | Rejected-Technical 1ST FLOOR FLAT NO A 104 ANANT EMEGINE PURANA BUS STAND KORBA CHHATTISGARH | KORBA | KORBA | CHHATTISGARH | 495678 | - | Rejected-Technical Rejected being L-4 bidder | |
| 3 | Rejected-Technical N A | - | Rejected-Technical Rejected being L-3 bidder | |
| 4 | Rejected-Technical MISSION HOSPITAL CHOWK KEDARPUR AMBIKAPUR DIST SURGUJA CG 497001 | AMBIKAPUR | SURGUJA | CHHATTISGARH | 497001 | - | Rejected-Technical Rejected being L-2 bidder |
Tender Value
₹48.9 L
EMD Value
₹61,200
Closing Date
15 Feb 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
STAFF OFFICER (EandM),SECL KUSMUNDA AREA
OFFICE OF THE STAFF OFFICER (EandM),SECL KUSMUNDA AREA P.O.KUSMUNDA COLLIERY 495454 DISTT. KORBA (CG)
Erection of LT Overhead line for illumination of coal dispatch road at Kusmunda OCP
2023_SECL_269738_1
SECL/GM/KSM/EnM/ eTender/22-23/60 dtd 02.02.2023
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
KUSMUNDA OPEN CAST PROJECT
Please refer Tender documents.
6 documents required · 6 mandatory
₹61,200
5 Apr 2023
2 Feb 2023
16 Feb 2023
2 Feb 2023
15 Feb 2023
3 Feb 2023
3 Feb 2023 - 8 Feb 2023
Amount
Description of Work
Shifting of materials other than pole upto pole pit.
Transporting of poles from road side to pole pits
Erection of metallic poles of following length above 10mts and upto 12 mts (with concreting).
Stringing of Rabbit Conductor (3 wire) (Conductor will be provided by department)
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/3.15 mm dia G.I stay wire and strain insulator etc. in cement concrete 1:3:6 (1 cement: 3coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Carpet Guarding
G.I. wire 4.0 mm (8 SWG) {i.e. 1 span= 20 Kg}
11 KV Guarding Channel 100 X 50 mm set.
Making of clamps
GI earthing pipe of 40 mm dia 3.04 mtr long with 12 mm hole at 18 places at equal distance trapered casing at lower end.
Providing and fixing of light fixtures : LED rating (in watts) = 150 W , Ingress Protection (IP rating) as per IS:10322 (part 1): 1982 latest = IP66 , LED Luminaire conformity to IS:10322/part 5/section 3/2012 latest and IS:16107 (part 2/sec 1): 2012 latest = YES, Rated Voltage = 230 V AC 50 Hz
Supplying and fitting of MS Nut and Bolts 1/2 Inch X 5 Inch.
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 100 A 16 KA.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent/ HPMV/HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching ON & OFF of street lights at sun set & sun rise or twilight (Auto ON, Auto OFF, Auto) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 3 output (1 output per phase) and suitable for three phase supply.
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm), G.I. bolts, nuts and washers, coach screws etc. as required
Dismantling of pole/street light standard/ strut embedded in brick ballast foundation etc. as required
Total impact of GST for the purpose of CTC
J.K. ELECTRICALS
MS R.P. JAISWAL
AARNA Constructions
stage.html
html • 0.04 MB
techsummary_279082.pdf
PDF • 0.20 MB
finsummary_279082.pdf
PDF • 0.75 MB
loa60.pdf
PDF • 1.20 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .