| 1 | L1₹14.3 LAccepted-Finance | L1 | Accepted-Finance Lowest Bidder | |
| 2 | L2₹18.3 L+₹4.0 L (28.0%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not admitted due to NO remarks in CE Delhi Zone WLR QE Dec 2025. Change in constitution involved. |
| Sl No | Description | Qty | Unit | M/s S.G. BUILDERS L2 | M/s Salasar Telecom L1 |
|---|---|---|---|---|---|
| 1.00Note: (i) The contractor or his authorized representative shall report daily to the Complaint Cell for collection of complaints and The contractor shall be required to attend complaints as and when intimated by the department through complaint slip , VYNUS , telephone or any otherauthorised means of communication .If it is not possible to rectify the same within timeline specified below, the matter along with detailed reasons shall immediately be brought to the notice of the Engineer-in-Charge by the contractor or his representative. If the Engineer-in-Charge is satisfied with the justification furnished, no recovery shall be effected on this account. (ii) (a) All No Light / Power Supply complaints shall be attended to and rectified within 01 hour, commencing from the date and time of issue/intimation of the complaint. Failure to attend the complaint within the stipulated period shall attract a penalty of Rs. 120/- for delay up to 04 hours and Rs. 240/- for delay beyond 04 hours, which shall be recovered from the contractor's dues. (b) All other routine maintenance complaints covered under the contract shall be attended to and rectified within 24 hours, commencing from the date and time of issue/intimation of the complaint. In case the complaint is not rectified within the stipulated period, a penalty of Rs. 120/- per complaint per day or part thereof shall be recovered from the contractor's dues.. However, labour charges for items covered under “M&L”, “S&F”, and “In Repair” shall be deemed to be included in the respective quoted rates. (iii) Items under this contract are of day-to-day nature and the complete scope/site cannot be forecast or handed over to the contractor at one time. The contractor shall therefore arrange adequate manpower, materials, and resources as per site requirements. In case the contractor fails to provide the required skilled labour in accordance with the contract provisions, suitable recoveries/penalties shall be levied as applicable. | |||||
| 1.01(iv) In addition to the above, the contractor shall arrange and maintain all necessary T&P required for execution of the work, such as multimeter , necessary electrical tools bag, tape roll , washers and screws of all sizes, , drilling machine with bits, and the like, including necessary safety measures, complete all as specified and directed by the Engineer-in-Charge. (v) The cost of all the above arrangements, obligations, T&P, consumables, labour, safety measures, and incidental requirements shall be deemed to be included in the quoted rates of the respective items and no extra payment whatsoever shall be admissible on this account. | |||||
| 2.00 | Supply and fix in repair of LED surface mounted Batten light 20 W 4 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F. ≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). ManufacturesWord Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testing facilities forLED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab forall testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C). complete all as specified and as directed. | 750 | Each | 245 ₹1,83,750 | 225 ₹1,68,750 Lowest |
| 3.00 | Supply and fix in repair of LED surface mounted Batten light 10 W 2 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt outputt . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed. | 90 | Each | 199 ₹17,910 Lowest | 225 ₹20,250 |
| 4.00 | S&F in repair decorative wall-mounted light fitting, body made of die-cast aluminum with powder-coated finish and frosted/clear glass/acrylic diffuser, suitable for holding LED lamp up to 15 Watt (B22 base), IP20 or higher protection, complete with all accessories for mounting on wall surface including screws, plugs, etc. Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose/DB, complete all as specified and directed. | 50 | Each | 390 ₹19,500 | 350 ₹17,500 Lowest |
| 5.00 | S&F in repair 12 watt LED Recessed/ surface Down lighter (Round/ square/Rectangular) SMD type Powder coated die cast /Extruded aluminum Body including trim with Aluminum Reflector with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed. | 100 | Each | 460 ₹46,000 | 325 ₹32,500 Lowest |
| 6.00 | S&F in repair LED bulkhead light fitting, 10 Watt, white colour, housing made of high-grade flame-retardant engineering plastic with clear prismatic diffuser, suitable for wall or ceiling surface mounting. The fitting will be provided with replaceable LED lamp (cool white) and include all required mounting accessories.Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose, complete all as specified and directed. | 20 | Each | 350 ₹7,000 Lowest | 350 ₹7,000 Lowest |
| 7.00 | Supply and fix in repair 36 W LED Recess mounting 2'x2' LED Luminaire having CRCA stell sheet housing comprising of LED's connected in series parallel,. Opal diffuser fixed in separate CRCA sheet steel frame. Opal diffuser frame is held with screws and SS strings and it can be suspended for easy maintenance Driver. constant current output driver. Finish Housing white powder coated (RAL9016). Fixture should have minium system level >=100 Lumens/ watt ,. Life of fixture 50K Hrs @ L70B50 Lumen maintenance, CCT 5700-6500k with same Limens/w CRI> 80, THD < 10%@ 240V Ac. An operetaing Voltage Range of 140-270V Minium Internal Surge Protection 3 Kv, IP 20 BIS certification ids required fo rLED Driver & Liminaire , OEM should have in house NABL Accrediated R&D and own Luminiare manufacturing facility to provide LM 79 report in house NABL accredited lab & LM80 report issued by LED manufacturer complete all as specified and directed. | 140 | Each | 1,350 ₹1,89,000 | 800 ₹1,12,000 Lowest |
| 8.00 | Supply and fix in repair 36 W LED Recess mounting 1'x4' LED Luminaire having CRCA stell sheet housing comprising of LED's connected in series parallel,. Opal diffuser fixed in separate CRCA sheet steel frame. Opal diffuser frame is held with screws and SS strings and it can be suspended for easy maintenance Driver. constant current output driver. Finish Housing white powder coated (RAL9016). Fixture should have minium system level >=100 Lumens/ watt ,. Life of fixture 50K Hrs @ L70B50 Lumen maintenance, CCT 5700-6500k with same Limens/w CRI> 80, THD < 10%@ 240V Ac. An operetaing Voltage Range of 140-270V Minium Internal Surge Protection 3 Kv, IP 20 BIS certification ids required fo rLED Driver & Liminaire , OEM should have in house NABL Accrediated R&D and own Luminiare manufacturing facility to provide LM 79 report in house NABL accredited lab & LM80 report issued by LED manufacturer complete all as specified and directed. | 60 | Each | 1,900 ₹1,14,000 | 1,550 ₹93,000 Lowest |
| 9.00 | Supply and fixing in repair of LED bulb 12 Watt B-22 Cap, AC 230V, 50 Hz suitable for Batten Holder/Bulk head/SK light fittings in replacement of old unsv lights any type complete all as specified and as directed. | 250 | Each | 60 ₹15,000 Lowest | 85 ₹21,250 |
Tender Value
₹19.9 L
EMD Value
₹40,000
Closing Date
5 Aug 2026, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
MAINT AND REPAIRS / REPLACEMENT OF UNSERVICEABLE WIRING, MCBs, MCCBs, DBs, LIGHTS, SUMMER AND WINTER APPLIANCES INCL ATTENDING DAY TO DAY PETTY COMPLAINTS AT DGIS, WARDEC, IML, 1 CBPO UNDER AGE E/M OF GE (SOUTH) DELHI CANTT
2026_MES_777124_1
GE/TOKEN-22/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹40,000
Yes
29 Sept 2026
8 Jul 2026
7 Aug 2026
8 Jul 2026
5 Aug 2026
22 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | (iv) In addition to the above, the contractor shall arrange and maintain all necessary T&P required for execution of the work, such as multimeter , necessary electrical tools bag, tape roll , washers and screws of all sizes, , drilling machine with bits, and the like, including necessary safety measures, complete all as specified and directed by the Engineer-in-Charge.
(v) The cost of all the above arrangements, obligations, T&P, consumables, labour, safety measures, and incidental requirements shall be deemed to be included in the quoted rates of the respective items and no extra payment whatsoever shall be admissible on this account. | - | - | - | - |
| 2 | Supply and fix in repair of LED surface mounted Batten light 20 W 4 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F. ≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). ManufacturesWord Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testing facilities forLED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab forall testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C). complete all as specified and as directed. | 750 | Each | - | - |
| 3 | Supply and fix in repair of LED surface mounted Batten light 10 W 2 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt outputt . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed. | 90 | Each | - | - |
| 4 | S&F in repair decorative wall-mounted light fitting, body made of die-cast aluminum with powder-coated finish and frosted/clear glass/acrylic diffuser, suitable for holding LED lamp up to 15 Watt (B22 base), IP20 or higher protection, complete with all accessories for mounting on wall surface including screws, plugs, etc. Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose/DB, complete all as specified and directed. | 50 | Each | - | - |
| 5 | S&F in repair 12 watt LED Recessed/ surface Down lighter (Round/ square/Rectangular) SMD type Powder coated die cast /Extruded aluminum Body including trim with Aluminum Reflector with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed. | 100 | Each | - | - |
| 6 | S&F in repair LED bulkhead light fitting, 10 Watt, white colour, housing made of high-grade flame-retardant engineering plastic with clear prismatic diffuser, suitable for wall or ceiling surface mounting. The fitting will be provided with replaceable LED lamp (cool white) and include all required mounting accessories.Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose, complete all as specified and directed. | 20 | Each | - | - |
| 7 | Supply and fix in repair 36 W LED Recess mounting 2'x2' LED Luminaire having CRCA stell sheet housing comprising of LED's connected in series parallel,. Opal diffuser fixed in separate CRCA sheet steel frame. Opal diffuser frame is held with screws and SS strings and it can be suspended for easy maintenance Driver. constant current output driver. Finish Housing white powder coated (RAL9016). Fixture should have minium system level >=100 Lumens/ watt ,. Life of fixture 50K Hrs @ L70B50 Lumen maintenance, CCT 5700-6500k with same Limens/w CRI> 80, THD < 10%@ 240V Ac. An operetaing Voltage Range of 140-270V Minium Internal Surge Protection 3 Kv, IP 20 BIS certification ids required fo rLED Driver & Liminaire , OEM should have in house NABL Accrediated R&D and own Luminiare manufacturing facility to provide LM 79 report in house NABL accredited lab & LM80 report issued by LED manufacturer complete all as specified and directed. | 140 | Each | - | - |
| 8 | Supply and fix in repair 36 W LED Recess mounting 1'x4' LED Luminaire having CRCA stell sheet housing comprising of LED's connected in series parallel,. Opal diffuser fixed in separate CRCA sheet steel frame. Opal diffuser frame is held with screws and SS strings and it can be suspended for easy maintenance Driver. constant current output driver. Finish Housing white powder coated (RAL9016). Fixture should have minium system level >=100 Lumens/ watt ,. Life of fixture 50K Hrs @ L70B50 Lumen maintenance, CCT 5700-6500k with same Limens/w CRI> 80, THD < 10%@ 240V Ac. An operetaing Voltage Range of 140-270V Minium Internal Surge Protection 3 Kv, IP 20 BIS certification ids required fo rLED Driver & Liminaire , OEM should have in house NABL Accrediated R&D and own Luminiare manufacturing facility to provide LM 79 report in house NABL accredited lab & LM80 report issued by LED manufacturer complete all as specified and directed. | 60 | Each | - | - |
| 9 | Supply and fixing in repair of LED bulb 12 Watt B-22 Cap, AC 230V, 50 Hz suitable for Batten Holder/Bulk head/SK light fittings in replacement of old unsv lights any type complete all as specified and as directed. | 250 | Each | - | - |
| 10 | Supply and fixing in repair of switch piano flush type 5/6 Amps SP one way complete all as specified and as directed. | 350 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.73 MB
TenderpagesT22.pdf
Tender Documents • 0.91 MB
BOQ_870309.xls
BOQ • 0.38 MB
SchofCreditT22.pdf
Additional Documents • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .