Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 231 SATYA VIHAR MADAN CONTRACTORS AND COMO VIJAY PARK DEHRADUN DEHRADUN UTTARAKHAND 248001 | DEHRADUN | UTTARAKHAND | 248001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 00 JALESAR MAHAVIR GANJ 00 VILLAGE TOWN JALESAR CITY ETAH ETAH UTTAR PRADESH 207302 INDIA | ETAH | UTTAR PRADESH | 207302 | Admitted-Finance |
Tender Value
₹50.6 L
EMD Value
₹50,000
Closing Date
3 May 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC MUZAFFARNAGAR
NEAR 132 KV SUB STATION BHOPA ROAD MUZAFFARNAGAR
WORK TENDER
2023_UPTCL_798549_1
ETC MU T 09 2023 24
Open Tender
Electrical Works
Item Rate
60 days
MUZAFFARNAGAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
EE ETD MUZAFFARNAGAR
₹50,000
23 May 2023
21 Apr 2023
4 May 2023
21 Apr 2023
3 May 2023
21 Apr 2023
Amount
SCHEDULE Q-1 Erection of 160 MVA Transformer (WORK)
Shifting of Main tank of 160 MVA Transformer from unloading place to Transformer plinth distance about 20 Mtr.
Additional Shifting of transformer 10 Mtr (a part of 5 mtr )
Providing and filling of dry air at the time of opening of blanking plate of 160 MVA Transformer main tank and filling of dry air, work shall including connecting pipe as required preasure of dry air.
Complete erection of 160 MVA transformer including erection of radiator, conservator tank, bushing their turrets connecting oil pipe line, cooling fan, motor drive machanism of tap changer, RTCC panel, oil pump and associated pipe line etc to complete the job satisfactorily.
Complete evacuation of 160 MVA Transformer main tank and filling of dry air/N2 of dew point -50ºC or better in vacuum and then pressure upto 0.25 kg/Cm² and again evacuation of the transformer tank after requited time interval (Approx 12 to 24 Hrs) using vacuum plant. The work shall include connecting pipes of machine as required, measuring dew point value of Dry Air/N2 during every cycle (1 Job is defined as complete cycle of evacuation, filling and maintaining of dry air in the transformer main tank).
Create the vacuum inside the transformer tank & stand at 24 Hrs. filling the oil step by step in 160 MVA Transformer.
Filling the transformer oil in oil tanker from drums by centrifuging machine to increase the BDV value and water content value less than 05 PPM (02 Nos. 20KL Tankers shall be provided by the department free of cost). And circulatioin of transformer oil of 160 MVA transformer in transformer tank by connecting centrifuging machine to be provided by the contractor. Testing BDV values of oil and IR values periodically till the required value. The water content value less than 05 PPM is achieved & contractor also required provide the final test result (BDV, water content, PPM & DGA test) from authorised test Lab(PGCIL and CPRI).
Inter-connection of 160 MVA Transformer with laying of cable and termination in between turrets, WTI, OTI, Buchholz relays, PRV, Cooling fans , Pumps, OLTC, Marshalling box etc. with proper ferruling as per drawing.
Laying, dressing and binding of cable including fixing of cable tray support strucuture and termination of cable marking the top and its ferruling as per schedule and RTCC panel, from transformer, marshaling box, driving mechanism to control room.
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
10 core x 2.5 mm2
Termination of following sizes of cable as laid above as per cable schedule including making necessary holes in glands plates or box where ever required fixing of cable glands of appropriate size, lugging and ferruling of each core and other associated work to complete the job satisfactorily. (The rates of terminatioin of Control cable including the all cores of cable at both end.)
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
10 core x 2.5 mm2
Earthing of Transformer body, MB, DM Box , OLTC, RTCC at two point using 75x10/50x6 mm (M.S. Flat provided by the department free of cost).
Jumpering work from Jack Bus to HV/LV bushings for 160 MVA transformer, work include cutting and bending of conductor.
Shifting of empty 20 KL capacity Oil Tanker from existing place to near 160 MVA Transformer with in 220 KV Switch Yard of 400 KV S/S Muzaffarnagar and after work completion shifting of 20KL oil tanker to proper place. ( Crane shall be provided by contractor)
Fabrication of 3 Meter long electrodes with 40mm MS Round having 150mm long conical shape (MS round will be provided by UPPTCL)
Delta earthing of 160 MVA Transformer by 3 meter long 40mm ms round having 150mm conical shape. Its peircing vertically inside the ground below 700mm. All three electrode arrange in triangular manner and connecting all 03 Nos electrodes with 75x10/50x6 mm MS flat laid on its edge. (All above work in one job)
SCHEDULE Q-2 Erection of Emulsifier System
Installation testing commissioning of quick opening flood, deluge value of HD of 150 NB as per Max working pressure 10 Kg/cm2, as per specification (HD/Mather Platt/equivalent) (In nos.).
Installation & Commissioning of gate value (sluice Valve/Butterfly valve) as per IS specification (IS Code: 14846) of (Zoloto/Kartar/Sir make) (In nos.)
Installation & testing commissioning of “Y” Type strainer (Kartar/Sir/Kalpana/Agro make) of dia Max working pressure 7 Kg/cm2 (In Nos.)
laying of different size of M.S pipe B class for fire water pipe line/support as per IS specification (IS Code-1239) Complete with elbow Tee Socket reducer etc. with anti-corrosive treatment with detail as below.
laying of different size of GI pipe B class for fire detection water pipe line as per specification (IS Code-1239) as per drawing enclosed complete with elbow Tee Socket reducer.
Installation of Flanges as per IS-1538 of different size as per drawing work include proper butt welding with pipe & proper packing and coupling with Nut & Bolt.
Installation & Commissioning of high velocity water spray nozzles flow capacity 3.5 Kg./cm2 Spray core angle 900.
Installation & Commissioning of Quartzite bulb detectors (QBD) operate at 900C sensing at rated temp for actuation of the element 10-12 sec.
Installation & Testing Commissioning of fixed differential switch (Danfoss/Indfoss make) type pressure switch range 1-10 Kg cm2
Installation OF Pressure gauge as per IS Specification IS Code-3624 Accuracy 5%
SCHEDULE Q-3 Erection of 220KV side Bay of 160MVA T/F-3
Erection of 245 KV SF-6 Circuit Breaker.
Erection of 245 KV Current Transformer
Erection of 198 KV Lighting Arrestors.
Erection of 120 KV Lighting Arrestors.
Erection and mounting of 245 KV CT, Junction Box.
Erection of 220/132 KV Control Panel of 160 MVA Transformer Panel as per technical specification.
Erectoin of 220 / 132 KV Relay Pannel as per technical specification.
Fabrication of 3 Meter long electrodes with 40mm MS Rod having 150 mm long conical shape (MS round will be provided by UPPTCL)
Ring earthing of 3 meter long 40mm ms round having 150mm conical shape. Its peircing vertically inside the ground below 700mm. All 06 electrode arrange in rectangular manner and connecting all 06 Nos. electrodes with 75x10/50x6 mm MS flat laid on its edge.(All above work in one job)
Ring earthing for 198 KV LA
Ring earthing for 120 KV LA
Earthing by cutting straightening, bending, laying below ground and above ground of following size of MS flat for 220 KV bay equipment and Structure,including Excavation of earth, its back filling, and all other associated work as required to complete the work.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Painting of MS flat of different size after cleaning of rusted surface 1st coat of Red Oxide and 2 coat of Bus Green Paint to complete the work.
Jumpering, interconnection of equipment with specified conductor and with main/Transfer/220 KV Jack Bus Bar of ACSR Moose/Zebra/Panther conductor. The work includes cutting of conductor, bending in proper shape, clamping with the help of clamps and all other associated work to complete the work.
Laying & Dressing of following size control cable in trench/cable trays from different equipments to CT,CVT and their junction boxesto control room. as per cable schedule including carriage of cable drum from store to site
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
10 core x 2.5 mm2
3.5X70 mm2 Al. Cable
Termination of following sizes of cable as laid above as per cable schedule including making necessary holes in glands plates or box where ever required fixing of cable glands of appropriate size, lugging and ferruling of each core and other associated work to complete the job satisfactorily. (The rates of terminatioin of Control cable including the all cores of cable at both end.)
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
10 core x 2.5 mm2
3.5X70 mm2 Al. Cable
SCHEDULE Q-4 Erection of 220KV Bay OF MODIPURAM at bus copuler bay
Erection of 220 KV Structure /Equipments
Erection of Main & Auxiliary structure lattice type ERW, , BCT, ALB, BBL, ALP etc. including consisting of beam and auxiliary structure for installation of CTs, PTs, LAs, etc.including shorting & stacking of structures and making hole in part of GI main/auxilary structure/exiesting structure/ angle and grinding with all cost of men T & P etc. The job consist of shifting of all material from store to site of erection, erection of structure as per drawing with the help of GI nut & bolt, flat & spring washer, matching the hole, cutting & matching of member if required including cost of all men and T & P. (GI structure Nut & bolt provided by UPPTCL)
Erection of 245 KV Line Isolator
Erection of 245 KV Tandem Isolator
Erection of 245 KV Post Insulator for support.
Erection of 245 KV Current Transformer
Erection of 245 KV Potential Transformer
Erection of 198 KV Lighting Arrestors.
Erection and mounting of 245 KV CT/ PT Junction Box.
Fabrication of 3 Meter long electrodes with 40mm MS Rod having 1500 mm long conical shape (MS round will be provided by UPPTCL)
Ring earthing of 198KV LAs by 3 meter long 40mm ms round having 150mm conical shape. Its peircing vertically inside the ground below 700mm. All 06 electrode arrange in rectangular manner and connecting all 06 Nos electrodes with 75x10/50x6 mm MS flat laid on its edge.(All above work in one job)
Earthing by cutting straightening, bending, laying below ground and above ground of following size of MS flat for 220 KV bay equipment and Structure,including Excavation of earth, its back filling, and all other associated work as required to complete the work.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Painting of MS flat of different size after cleaning of rusted surface 1st coat of Red oxide and 2 coat of Bus Green Paint to complete the work.
Stringing of 220 kv Jack Bus with Moose conductor. The work includes cutting, bending & hoisting of conductor, fixing of single /double bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily(18 meter).
220KV Jack Bus three phase
Jumpering, interconnection of equipment with specified conductor of various 220 KV Main/Transfer/Jack Bus Bar of ACSR Moose conductor. The work includes cutting of conductor, bending in proper shape, clamping with the help of clamps and all other associated work to complete the work.
Laying & Dressing of following size control cable in trench/cable trays from control room to various 220 KV equipments like CB, CT, CVT and their junction boxes. as per cable schedule including carriage of cable drum from store to site
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
10 core x 2.5 mm2
Termination of following sizes of cable as laid above as per cable schedule including making necessary holes in glands plates or box where ever required fixing of cable glands of appropriate size, lugging and ferruling of each core and other associated work to complete the job satisfactorily. (The rates of terminatioin of Control cable including the all cores of cable at both end.)
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
10 core x 2.5 mm2
SCHEDULE Q-5 Erection of 220KV BUS COUPLER
Erection of Main & Auxiliary structure lattic type DTM, GTM, BXM, ATM, BXM, BCT, ALP ,CB etc. consisting of coloumn, beam, peak, mast etc. and auxilary structure for installation of CTs, LAs, etc including shorting and stacking of structure and making hole in part of GI Main/Axiallary structure/existing structure/angle and grinding with all cost of men & T&P. The job consist of shifting of all material from store to site of erection, erection of structure with the help of GI nut & bolt, flat & spring washer, matching the hole, cutting & matching of member if required including cost of all men and T & P complete the work.(structure and nut & bolt will be provided by UPPTCL)
Erection of 245 KV SF-6 Circuit Breaker.
Erection of 245 KV Bus isolator
Erection of 245 KV Current Transformer.
Erection and mounting of 245 KV CT Junction Box.
Earthing by cutting straightening, bending, laying below ground and above ground of following size of MS flat for 220 KV bay equipment and Structure,including Excavation of earth, its back filling, and all other associated work as required to complete the work.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Painting of MS flat of different size after cleaning of rusted surface 1st coat of Red Oxide and 2 coat of Bus Green Paint to complete the work.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Stringing of three Phase 220 KV Jack Bus with Moose conductor. The work includes cutting bending of conductor, fixing of single /double bolted type tension fitting/ suspension. Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification.
Jumpering, interconnection of equipment with specified conductor of various 220 KV equipments with main/Transfer/Jack Bus Bar. The work includes cutting of conductor, bending in proper shap, clamping with the help of clamps and all other associated work to complete the work.
Following size control cable laying in trench/cable trays from 220 KV CB, CT,CVT and their juntion boxes to 400 KV control room as per cable schedule including carriage of cable drum from store and all other associated work.
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
10 core x 2.5 mm2
14 core x 2.5 mm2
Termination of following sizes of cable as laid above as per cable schedule including making necessary holes in glands plates or box where ever required fixing of cable glands of appropriate size, lugging and ferruling of each core and other associated work to complete the job satisfactorily. (The rates of terminatioin of Control cable including the all cores of cable at both end.)
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
10 core x 2.5 mm2
14 core x 2.5 mm2
SCHEDULE Q-6 132 KV Bay & Bus Bar Extension Work
Erection of Main & Auxiliary structure lattic type ATM, BTM, AXM,BBL, BTI, APR, BCT, ALP etc. consisting of coloumn, beam, peak, mast etc. and auxilary structure for installation of CTs, LAs, etc including shorting and stacking of structure and making hole in part of GI Main /Axilliary structure /existing structure/angle and grinding with all cost of men and T&P etc . The job consist of shifting of all material from store to site of erection, erection of structure as per drawing with the help of GI nut & bolt, flat & spring washer, matching the hole, cutting & matching of member if required including cost of all men and T & P excluding GI structure Nut & bolt to complete the work upon foundation and its proper tightening.
Erection of 145 KV SF-6 Circuit Breaker.
Erection of 145 KV Current Transformer.
Erection and mounting of 145 KV CT, Junction Box.
Erection of 145 KV Bus/Line Isolator.
Erection of 145 KV Tandom Isolator
Erection of 145 KV Post Insulator for support.
Laying of 40 mm dia M S round below the ground level upto earth earthmate including excavation of earth and its back filling after laying earthing of earthmat including shifting of 40mm MS Round from store place at the Sub-Station to switchyard.
Febrication of 3 meter long elelctrode with 40 mm dia M S round bar having 150 mm long conical shape and then peircing it vertically inside the ground, 700mm below the ground level including shifting of MS round from storage place at the Sub-Staiton to switchyard.
Making of cross joint of above laid 40 mm dia M S round below the ground level by welding at all 4 corners including welding of suitable size 2 no M S angle pieces on opposite corners of the corss joint.
Making of end joint of above laid 40 mm dia M S round bar with Top of the already vertically pierced M S electrodes 700 mm below the gournd level by welding.
Making of 300 mm long lap joint of above already laid round bar to connecting existing earth mat of the Sub-station.
Earthing by cutting straightening, bending, laying below ground and above ground of following size of MS flat for 132 KV bay equipment and Structure,including Excavation of earth, its back filling, and all other associated work as required to complete the work.
Laying of MS Flat of size 75x10 mm
Laying of MS Flat of size 50x6 mm
Laying of MS Flat of size 25x6 mm
Painting of MS flat of different size after cleaning of rusted surface 1st coat of Red Oxide and 2 coat of Bus Green Paint to complete the work.
MS Flat of size 75x10 mm
MS Flat of size 50x6 mm
MS Flat of size 25x6 mm
Stringing of Three Phase 132 KV Jack Bus main bus & transfer bus with ACSR panther/tarantula/Moose condutor as mentioned below. The work includes cutting & bending of conductor, fixing of single /double bolted type tension fitting Hoisting of disc insulator and shifting of material from store site to erection site and all other associated work to complete the work satisfactorily as per drawing and technical specification.
132 KV Main Bus
132 KV Transfer Bus
132 KV Jack Bus
Jumpering, interconnection of equipment with specified conductor of various 132 KV equipments with main/Transfer/Jack Bus Bar. The work includes cutting of conductor, bending in proper shap, clamping with the help of clamps and all other associated work to complete the work.
Laying & Termination of following size control cable in trench/cable trays from different control room equipments to 220/132 KV CB, CT,CVT and their juntion boxes. Transformer marshaling box, isolators box and other outdoor equipments installed in 220/132 KV switch yard as per cable schedule including carriage of cable drum from store and all other associated work.
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
10 core x 2.5 mm2
Termination of following sizes of cable as laid above as per cable schedule including making necessary holes in glands plates or box where ever required fixing of cable glands of appropriate size, lugging and ferruling of each core and other associated work to complete the job satisfactorily. (The rates of terminatioin of Control cable including the all cores of cable at both end .)
2 core x 2.5 mm2
4 core x 2.5 mm2
6 core x 2.5 mm2
10 core x 2.5 mm2
SCHEDULE Q-7 Dismantling Work
Dismantling of Main & Auxiliary structure lattice type RTE, BXM, , BCT, ALP etc. consisting of beam and auxiliary structure for installation of CTs, PTs, LAs, etc including shorting and stacking. The job consist of shifting of all material from site to store.
Dismantling of 245 KV Tandem Isolator
Dismantling of 245 KV SF-6 Circuit Breaker.
Dismantling of 245 KV Post Insulator for support.
Dismantling of 245 KV Current Transformer of ratio 800/500/1A
Dismantling of 245 KV PotentialTransformer
Dismantling of 198 KV Lighting Arrestors.
Dismantling of 245 CT/ PT Junction Box.
Dismantling of 220 KV jumpers
Dismentling of 220 KV Jack Bus Moose conductor three phase (36 meter)
SCHEDULE Q-8 Material (Supply)
single Tension fitting for MOOSE Conductor without buckle and as per sample.
single Suspension fitting for Single moose Conductor with hardware set as per sample.
4 Bolted Type PG clamp suitable for MOOSE TO MOOSE Conductor Complete with HDG nut bolt & washer as per sample.
220 KV Bus/ Line Isolator clamp made of aluminum alloy LM-6 for MOOSE conductor with HDG nuts & bolts and washer as per technical specification .
220 KV Tandam Isolator clamp made of aluminum alloy LM-6 for MOOSE conductor with HDG nuts & bolts and washer as per sample.
220 KV CT clamp made of aluminum alloy LM-6 for Zebra MOOSE/conductor with HDG nut & bolts and washer as per sample.
220 KV PT clamp made of aluminum alloy LM-6 for MOOSE/Zebra conductor with HDG nut & bolts and washer as per SAMPLE.
220 KV LA clamp made of aluminum alloy LM-6 for MOOSE conductor with HDG nut & bolts and washer as per sample.
Bus Post clamp suitable for MOOSE/Zebra conductor complete with hot dip galvanized nut, bolts & washer as per sample.
Supply of cable gland of different sizes
2C x 2.5 mm (16mm)
4C x 2.5 mm (19mm)
6C x 2.5 mm (22mm)
10C x 2.5 mm (25mm)
Supply of copper lug of different types.
Ring type of size 2.5 mm
Pin type of size 2.5 mm
4 Bolted Type PG clamp suitable for TARANTULLA TO TARANTULLA Conductor Complete with HDG nut bolt & washer as per sample.
132 KV Bus/ Line Isolator clamp made of aluminum alloy LM-6 for MOOSE conductor with HDG nuts & bolts and washer as per sample.
132 KV Tandam Isolator clamp made of aluminum alloy LM-6 for MOOSE conductor with HDG nuts & bolts and washer as per sample.
132 KV CT clamp made of aluminum alloy LM-6 for MOOSE conductor with HDG nut & bolts and washer as per sample.
Supply quick opening flood, deluge value of HD of 150 NB as per Max working pressure 10 Kg/cm2, as per specification (HD/Mather Platt/equivalent) (In nos.).
Supply of gate value (sluice Valve/Butterfly valve) as per IS specification (IS Code: 14846) of (Zoloto/Kartar/Sir make) (In nos.) "150NB"
Supply “Y” Type strainer (Kartar/Sir/Kalpana/Agro make) of dia Max working pressure 7 Kg/cm2 (In Nos.) "150 mm"
Supply of M.S pipe B class for fire water pipe line/support as per IS specification (IS Code-1239) Complete with elbow Tee Socket reducer etc. with anti-corrosive treatment with detail as below.
Supply GI pipe B class for fire detection water pipe line as per specification (IS Code-1239) as per drawing enclosed complete with elbow Tee Socket reducer.
Supply of Flanges as per IS-1538 of different size as per drawing work include proper butt welding with pipe & proper packing and coupling with Nut & Bolt.
Supply, of high velocity water spray nozzles flow capacity 3.5 Kg./cm2 Spray core angle 900.
Supply of Quartzite bulb detectors (QBD) operate at 900C sensing at rated temp for actuation of the element 10-12 sec.
Supply, of fixed differential switch (Danfoss/Indfoss make) type pressure switch range 1-10 Kg cm2
Pressure gauge as per IS Specification IS Code-3624 Accuracy 5%
Versha and Brothers
Meena Elect & Engg. Works
Gupta Elect and Engg Works
Madan contractors & Co.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .