Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-Finance NEW DELHI | NEW DELHI | DELHI | 110001 | L1 | Accepted-Finance L1 | |
| 2 | L2₹20.1 L+₹83,851.62 (4.36%)Rejected-Finance 218 TANGE WALI GALI KACHI CHAWNI JAMMU JAMMU AND KASHMIR 180001 | JAMMU | JAMMU AND KASHMIR | 180001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹20.4 L+₹1.1 L (5.86%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹21.4 L+₹2.1 L (11.1%)Rejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | L4 | Rejected-Finance L4 |
Tender Value
₹24.0 L
EMD Value
₹48,550
Closing Date
9 Nov 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Elect)/KBZ
MUNICIPAL CORPORATION OF DELHI OFFICE OF THE EX. ENGINEER (ELECT)-IV/KBZ TOURIST CAMP SITE, J.L. NEHRU MARG, DELHI-02
Provision of lighting arrangements in Tikona park-ABCD block-WEA, Gol Chakkar-Channa Market-WEA, Opp. 9A/1-Gol Chakkar-Channa Market-WEA, Opp. 14A/22-Gol Chakkar-WEA, Opp. Shop No. 62-Bada Bazaar Road-Old Rajinder Nagar, Opp. Shop No. 18-Bada Bazaar
2026_MCD_296428_1
NIT No 41/EEE/KBZ/MCD/2026-27
Open Tender
Electrical Works
Percentage
90 days
Rajinder Nagar
Please refer to the tender documents
5 documents required · 5 mandatory
₹590
₹48,550
20 Nov 2026
30 Oct 2026
9 Nov 2026
30 Oct 2026
9 Nov 2026
30 Oct 2026
30 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm | - | Metre | 28 | - |
| 2 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm | 380 | Metre | 37 | ₹14,060 |
| 3 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (without charcoal/ coke and salt) as required | 20 | Each | 5,368 | ₹1,07,360 |
| 4 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | - | Metre | 42 | - |
| 5 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) | - | Metre | 247 | - |
| 6 | Fabrication, Supplying, Installation, testing, Commissioning of 12 metres semi high mast System with its accessorles Mast shaft shall be in one section, hot dip galvanized 4mm thick(Single dip) Inside & out sides & suitable for wind velocity as per IS 875 part .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For semi High Mast head frame ,2 point suspension system ,5 X 2.5 sqmm Copper conductor with steel wire rope 5mm dia. (7/19 construction) single drum winch galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the semi high mast considering the safe soil bearing capacity at site as 10 T/sqm at 2 mts. Depth with all material i/c 4 Nos. S.P MCB, 1 No. Double pole 16 Amp. MCB etc as reqd. Logo/Name .of manufacturer shall be either embossed or Rivited plate on the pole. galvanization as per relevant IS. | 7 | Each | 1,54,138 | ₹10,78,966 |
| 7 | Fabrication, supply & erection of 4.0 mtr height, minimum 3 mm thick, bottom dia of 130 mm & top dia of 70mm, base plate of size 225 x 225 x 12 mm thick flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplylng and fixing of 6 mm thick laminated mounted sheet inside the window and i/c providing and welding 3 nos. Gl strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel i/c providing and flxing DIN channel of suitable length, 6 Amp. SPMCB 'C' Curve characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be either embossed or Rivited plate on the pole Galvanization as per relevant IS code etc as required. | 30 | Each | 8,080 | ₹2,42,400 |
| 8 | Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm(L) x 450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -960mm long (approx.) - 8 nos. and reinforcement of cold twisted bar of 8 mm dia - 1400 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts size 16 mm dia, 600mm long, J type i/c 2 nos template anchor plates of size 225 mm x 225 mm x 3 mm and providing DWC HDPE pipe for cable entry & exit as required for 3 m and 5 mtr pole. | - | Each | 7,743 | - |
| 9 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. mm | - | Metre | 95 | - |
| 10 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). -45 Watt. | 60 | Each | 1,966 | ₹1,17,960 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tendernotice_2.pdf
PDF • 1.00 MB
Tendernotice_3.pdf
PDF • 0.13 MB
ConditionRajinderNagar.pdf
Tender Documents • 0.30 MB
BOQ_345467.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .