Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹40.6 L+₹1.0 L (2.53%)Rejected-Finance WARD NO 4 NEAR MASZID BHATTAGAON DISTT JHANSI 284001 UTTAR PRADESH | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹40.9 L+₹1.3 L (3.33%)Rejected-Finance | L3 | Rejected-Finance Not become lowest bidder |
Tender Value
₹45.2 L
EMD Value
₹90,400
Closing Date
15 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Deepak Kumar
Garrison Engineer Jhansi
Spl Repair to Bldg No- P-36 and Certain other sanctioned works at Mil Station Nowgong (BKD) under AGE B/R-I of GE Jhansi
2022_MES_553010_1
GE/JHA/TOK/45 OF 2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Jhansi
₹90,400
Yes
3 Dec 2022
20 Sept 2022
17 Oct 2022
20 Sept 2022
15 Oct 2022
2 Oct 2022
60 days
Amount
Dismantling posts or struts (wood,or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling of wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/ slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section in any position as in framed /unframed works such as roof purlins, rafters, fillets ,ridges etc as in ceiling complete all as specified and directed.
Dismantling water tanks RCC/ PVC any description exc 500 but n.exc 1000 litres capacity complete all as specified and directed.
Dismantling Asbestos Cement Corrugated or Semicorrugate in Roof covering complete all as specified and directed.
Demolition of cement concrete in ground/First floor and paving n exc 15cm thickness (below or above the ground level) built in cement mortar complete all as specified and directed.
Demolition of RCC Not exc 15cm thickness Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete all as specified and directed.
Demolition of brick work or stone/ boulder Masonry, built in cement mortar including all quoins, pillars etccomplete all as specified and directed.
Excavation in post hole (similar hole) each not exceeding 0.5 Cum getting out in any type of soil complete all as specifide and directed.
Excavation over areas not exc 1.50 m in depth for foundation etc & getting out in any type of soil complete all as specifide and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in any type of soil for foundation/laying of cable etc complete all as specifide and directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete (1:3:6) type C1 using 40mm graded agg as in foundations, filling and mass concrete
M&L for mild steel angle and flat Iron for posts and struts and straining bars in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specifide and directed.
M&L for chain link fencing, of size 50 x 50mm and (overall dia of wire 4mm), fixed to any type of standards, rails, straining bolts etc, including provision of binding wire, complete all as specified and directed.
Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished fair and even complete all as specified and as directed.
Preparing newly plastered surfaces of wall and applying two coats of distemper oil emultion over a coat of JK/Birla wall care putty complete all as sppecified and directed.
Preparing newly plastered surfaces of wall and applying three coats of white wash complete all as sppecified and directed.
M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles with and including 10 mm thick rendering in CM (1:4) for receiving the tiles, complete all as directed.
M&L flor Jointless Non-skid cermaic tiles 7 to 8mm thick (squre/rectanglar) are of ech tiles 600MMX600M, in each floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6.
M & L for Non- skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed/ bedding layer in CM (1:6) complete all as specified and as directed.
M&L 75 mm thick cement concrete type C1 1:3:6 (using 40 mm graded stone agg) in sub base of flooring/ hard standing and plinth protection.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store.
S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors.
S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors.
S & F in repairs 15 mm bore Bib taps, fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.( Make :- Cera (Ist Quality),Parry ware (super fine),Hindware(Ist Quality).
S & F in repairs 15 mm bore Bib taps long body fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.( Make :- Cera (Ist Quality),Parry ware (super fine),Hindware(Ist Quality).
S & F in repairs 15 mm bore stop/angle cock fancy type,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule ( Make :- Cera (Ist Quality),Parry ware (super fine),Hindware(Ist Quality).
S & F in repairs 15 mm bore concealed type stop cock fancy type,chromium plated with long sank crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PVC float valve (Make: paryag) complete all as specified in SSR Part I including disconnectiong of existing tank (Make Sintex Reno,PolyWell)
S & F in repairs 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair Vitreous China wash basin, white, flat back, size 580x450mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP waste copling,including PTMT PVC connection 600mm complete all as specified and directed Cera (Ist Quality),Parry ware (super fine),Hindware(Ist Quality).
S & F 15 mm brass mixture fancy type,chromium plated for mixing hot & cold water with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule cmplete all as specified and directed Cera (Ist Quality),Parry ware (super fine),Hindware(Ist Quality).
S & F Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union Cera (Ist Quality),Parry ware (super fine),Hindware(Ist Quality).
Supply and Fix in repairs 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, high level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long. ( Make:- Cera (Ist Quality),Parry ware (super fine),Hindware(Ist Quality).
S&F in repair of towel rail 20mm dia 600 mm long and wall bracket made of cast copper alloy, chromium plated, complete all as directed.
S&F in replacement of 1st quality vitreous china squatting pan Orissa pattern of size 580x440 mm, white colour with integral foot rests water closet including flush pipe but exluding flushing cistern, duly fixed in lime concrete bedding and making good of floor surface, complete all as directed.
M&L for Green marble 18/20 mm thick in steps, pillars, wndow cills, pillars, window cills, cooking platforms and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Taking down eaves gutter and rain water pipes including all fittings any size and pattern.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/trench.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls/trench.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal.
S & F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal.
S & F PVC Floor trap of 75 mm outlet with grating including jointing to waste pipe in run lead.
Plain Cement Concrete Type B1 (1:2:4) (using 20 mm graded stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates,hold fast and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work.
Taking down chowkhats with shutters (without taking off shutters from the frame) area exc 1.5 sqm but not exceeding 4 sqm each including cutting holes in brick/ stone wall built in cement / lime mortar, embedded portion exc half brick but n.exc one brick for inserting new hold fast and making good the disturbed portion/surfaces, in CM 1:3 complete all as directed.
Taking down Chowkats or frames Not exceeding 1.5 Sq. M each (Without taking off shutters from the frame)
Taking down shutters of any description exceeding 01 Sqm and not exc 02 Sqm each, complete all as specified and directed.
S&F of Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm wood coloured PVC sheet and edges, reinforced with MS square tube, as specified in SSR Part-II 2010 (Section 8, on Page no - 175), complete all as directed.
S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps, plain angle cleats for securing purlins and similar small articles confirming to Fe 290. GdeE-165
S & F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc.
S&F 35 mm thick factory made flush shutters solid core construction with block board core and plywood face panels, commercial type on both side complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing
S & F 200 mm long aluminum barrel tower bolts of extructed section section.
S & F 250 mm long mild steel sliding door bolts,plate type, stove enamelled black,with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate.
S&F Floor door stopper140 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer.
S&F steel window with side hung shutters including projecting type hinges with stell handle, and steel peg stay, complete with glazing bars dovetailed or welded complete all as specified and directed.
S&F steel Ventilator with side hung shutters including projecting type hinges with stell handle, and steel peg stay, complete without glazing bars dovetailed or welded complete all as specified and directed.
Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane incl hacking out old glass complete all as specified and directed.
S & F stainless steel wire cloth 0.71 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed
S & F for stainless steel kitchen plate rack size 750x 600x230 mm including fixing arrange ment to walls with rawel plug or wooden plugs.
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste cupling, wastepipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete.
M&L for stainless steel curtain rod 25mm dia steel pipe cutting in to length required at site and fixed to brackets complete all as specified and directed by Eng-In-Charge
Supply and fixing of stainless steel doom type brackets for curtains rods of 25mm dia including necessary drilling and fixing of screws Qty – 220 pairs.
M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6
M&L for RCC Type A1 1:1.5:3 (20 mm stone agg) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, chajja, canopies, deck slabs and in shelves and the like
M&L for mild steel deformed TMT bars 5 mm To 10mm dia (as in reinforcement) cut to length, bent to shape require including cranking, bending spirally for hooking for column, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia
Form work to soffits of suspended slabs such as roof slabs, floor slabs and lintels, chajja landingand similar work n exc 200mm thick.
M & L Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre tocentre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the in termediate channel at 457 mm centre to centre incl Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long , expansion hold fasteners 12.5mm dia. 40mm long and Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified
M&L mild steel work as roof trusses (framed) trussed, purlins, crane gantries ,rails and fastenings and heavy brackets framing (beams, tee, angle, channels or flat sections) etc complete all as specified and directed .
M &L for framed work such as grills grating etc with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars , barred iron doors, ladders, framed balusters, walkways railings and similer work confirming to Fe 290 Gde E - 165 complete all as specified
Taking down cement plaster on brick or stone wall including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick rendering in CM (1:4) on fair/other than fair faces of brick work finished even and fair complete all as specified and directed.
M&L for 15 mm thick rendering in CM (1:6) on fair faces of brick work finished even and fair complete all as specified and directed.
M&L for preparation of new plastered surface and applying two coat of cement based paint over and incl one coat of exterior grade cement based primer, complete all as specified and directed.
S&F SS grating of squre/round shape, overall size of 150x150mm with hinge type openable jali of 100 mm dia size with and incl fixing with CM to floor/nahani traps etc, complete all as directed.
S&F in repair of PVC waste pipe 32 mm dia 750 mm long suitable for wash hand basin & urinal, complete all as specified and directed.
S&F in replair of waste coupling, chromium plated (half or full threaded), 32 mm dia size, complete all as directed.
S&F in repair of PVC connection 450 x 15mm dia PTMT (PVC), complete all as directed.
S&F factory made solid PVC moulded with partical board core door shutter 28 to 30mm thick (Stiles) with 2, 4 or 6 raised panel design with 2mm thick Wooden texture moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification and drawing, complete all as specified and directed.
S&F of 100 mm size butt hinges, extruded aluminum alloy with galvanized mild steel pin type B-21 anodized complete.
S&F of aluminium alloy anodized sliding door bolt 200mm length with hasp staple and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all specified and directed.
S&F of 150mm long barrel tower bolt aluminum anodized extruded section fixed with cadmium plated screws complete all as specified and directed.
S&F of 150mm aluminum handle cast type anodized complete all specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in padding levelling etc and roof kerbs, complete all as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Supply only integral liquid water proofing compound, mixed in CM as per manufacturer instruction, complete all as directed.
M&L for hardcore of gauge not exc 63mm deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone agg) as in sub base etc complete all as directed.
M&L for sand filling under floor or in foundation including watering and consolidation etc complete all as directed.
M&L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment etc complete all as directed.
Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
Material & Labour for Power Cables, Aluminum Stranded Conductor XLPE Insulated Of size 25 Sqmm 4 core, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings / connecting overhead lines with suitable binding wire and testing on completion complete all as specified and directed by Engineer-in-Charge. Make: Finolex / Havells / Polycab / Universal / Gloster / KEI. (Note: Excavation, earth work and protection pipe etc shall be measured and paid separately under relevant items of schedule.)
All as per item No. 103.00 here-in-before but of size 10 sqmm, 2 core.
Supply and fix 50mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed by Engineer-in-Charge. Make : Jindal / Tata / Zenith / Prakash Surya / Swasthik
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge. Make: Finolex / Kisan / Prince / Tirupati /Supreme / Jain Irrigation Sys
M&L point wiring for one light point / ceiling fan point / exhaust fan pint with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass screws for mounting switches, sockets, fan regulator, etc controlled by one switch complete all as specified and directed by Engineer-in-Charge. Make: Conduit-AKG/ Atul/ Kalinga/Modi/Precision/Modi Wire - Havells/ Polycab/ Finolex / Anchor Note : 1. In case cutting & chasing of conduit is encountered with any beam / column/Stone wall, the ISI Marked PVC casing & capping or surface conduit will be used to avoid any damage to the RCC portion. 2. No cutting & chasing shall be done on ceiling surface for laying PVC conduit for ceiling fan point wiring etc, hence the PVC casing & capping or surface conduit will be used for the same. 3. In place of terminal box on stone wall, PVC gang box/rectangular box for mounting switches/sockets/regulators with back and front cover will be used.
All as per item No. 107.00 above but for Lamp holder point controlled by one 6 Amp switch one way complete all as specified and as directed.
All as per item No 107.00 here in before, but for one Switch socket 6 Amps, 2-in-1 on same board complete all as specified and as directed
All as per item No. 107.00 above but for one 6 Amps, 2-in-1 switch socket out let flush type on the independent board complete as directed.
All as per item No. 107.00 here-in above but with 2.5 Sqmm copper conductor cable along with one run of 2.5 Sqmm copper conductor cable green in colour for continuous earthing for One 16Amps socket point on the independent board controlled by one switch complete all as specified and directed by Engineer-in-Charge.Make: Conduit-AKG/ Atul/ Kalinga/Modi/Precision/Modi Wire - Havells/ Polycab/ Finolex / Anchor
Supply and fix in replacement ceiling rose 6 Amps, 3 plate, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA / SSK
Supply and fix in replacement switch piano flush type 6 Amps, one way, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA/ SSK
Supply and fix in replacement socket 6 Amps, 2-in-1 flush type universal 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA / SSK
S&F, in repalcement, of Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA / SSK
S&F, in repalcement, of Socket, 6 pin, 16 Amp, , 240 volts, complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA / SSK
S&F, in repalcement of angle/batten type Lamp holder, metal cased, bakelite body, 240 volts, complete all as specified and directed. Make: Havells(Reo) / Anchor/ CONA / SSK
S&F of 9 W White LED retrofit lamp B-22 holder base with polycarbonate diffuser and heat sink, complete all as specified and directed. Make : Havells / Bajaj / Wipro / Philips /Osram
Supply and fix electronic fan regulator rotary type in 5 steps, 240V, 50Hz complete all as specified and directed. Make: Havells(Reo) / Goldmedal/ SSK /GM
Supply and fix MCCB / MCB distribution board, Vertical TPN, 4 way with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: (i) MCCB / MCBs shall be measured and paid separately. (ii) In case cutting & chasing is encountered with any beam / column/Stone wall, the DBs may be installed on stone wall only as directed by Engineer-in-charge. Make : Standard / Indo Asian / L&T / Havells
Supply and fix in replacement MCB distribution board, SPN, 8 way in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.Make : Standard / Indo Asian / L&T / Havells Note: (i) MCBs shall be measured and paid separately. (ii) In case cutting & chasing is encountered with any beam / column/Stone wall, the DBs may be installed on stone wall only as directed by Engineer-in-charge.
Supply and fix in replacement MCB distribution board, TPN 4Way in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: (i) MCBs shall be measured and paid separately. (ii) In case cutting & chasing is encountered with any beam / column/Stone wall, the DBs may be installed on stone wall only as directed by Engineer-in-charge. Make : Standard / Indo Asian / L&T / Havells
Supply and fix MCCB 100A, 18 KA, 3 Pole, 415 V, 50 Hz with fixed thermal magnetic release including cable connection withcomplete all as specified and directed by Engineer-in-Charge. Make : Standard / Indo Asian / L&T / Havells
S&F in replacement MCB TPN 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.Make : Standard / Indo Asian / L&T / Havells
S&F in replacement MCB TP 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.Make : Standard / Indo Asian / L&T / Havells
S&F in replacement MCB SPN 40 amps 240 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.Make : Standard / Indo Asian / L&T / Havells
S&F in replacement MCB SP 06 to 32 amps 240 volts C curve, 50 HZ AC 10 KA complete all as specified and directed.Make : Standard / Indo Asian / L&T / Havells
Supply and fix LED batten with CRCA sheet steel body box type pre-wired suitable for and including provision of 1x20 Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge. Make: Philips / Havells / Wipro / Bajaj / Osram
Supply and fix Exhaust Fan 300mm sweep, 900 RPM, metal body with louvers suitable for working on 230V, 50 Hz, Single phase AC supply complete all as specified and as directed. Make: Khaitan / Usha / Almonard / Bajaj / Havells
Taking down ceiling fan from any position sealing cable end, dismantling blades and depositing fan and blade to E/M Store as directed
S&F ceiling fan 1200mm sweap size, with and incl ceiling clamp, rubber real, set of 03 blades, 02 nos canopy, metal body, double bearing and making all necessary elect connection complete all as specified and directed. Make : Havells /Orient / Usha /Bajaj
S&F in replacement down rod in any position/at any height suitable for hanging ceiling fans of 1200/1400 mm sweep made up of medium grade GI pipe 15 mm dia any length as per site requirement and making hole and cut in rod complete all as specified and directed.
Supply and fix in replacement LED street/security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 40mm dia light grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed by Engineer-in-Charge. Make: Philips / Havells / Wipro / Bajaj / Osram
Taking down existing sub main wiring of aluminium / copper of 4/6/10sqmm size incl all accessories complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering etc, complete all as directed.
M&L for sub main wiring along with earth wire with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge for the following sizes:- Note: (i) Three runs of copper cable and one run of PVC conduit shall be measured as one unit length (ii) Five runs of copper cable and one run of PVC conduit shall be measured as one unit length (iii) In case cutting & chasing of conduit is encountered with any beam / column/Stone wall, the PVC casing & capping or surface conduit will be used to avoid any damage to the RCC portion as directed.
2x6 Sqmm + 1x6 Sqmm
2x4 Sqmm + 1x4 Sqmm
4x6 Sqmm + 1x6Sqmm
M&L for earthing with galvanized steel earth plate electrode of size 600 x 600 x 6 mm buried directly in ground earth pit not less than 2.25 mtr below of normal ground level with top edge of earth plate should not less than 1.5 mtr below normal ground level and connected to galvanized iron earth lead wire of size 4 mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate No.3 of MES SSR Part I connecting to earthing test point on completion with and including 15 mm bore GI light grade protection pipe (7.5 mtr long) for earth lead GI lead wire 4mm dia (7.5 mtr long), PCC pit with cover in PCC 1:2:4 type B-1 reinforced with 8 mm dia tor bars @ 80mm C/C, 20mm dia medium grade watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work, complete all as specified and directed.
M/s JS Constructions
Shri Tirupati Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .