Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹28.4 LAccepted-AOC | ₹28.4 L Quoted ₹28.6 L | 1 | Accepted-AOC Qualify in Financial Bid |
| 2 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
Tender Value
₹33.0 L
EMD Value
₹66,080
Closing Date
10 Feb 2025, 6:00 pmClosed
Chief Executive Officer, ADMA
Amber Development and Management Authority Old Vidhan Sabha Bhawan, Near Hawa Mahal, Jaipur
Repairing and AMC of VRF type HVAC systems installed at Albert Hall, Jaipur.
2025_Amber_445140_2
19/2024-25
Open Tender
Electrical Works
Percentage
365 days
Albert Hall
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Chief Executive Officer, ADMA
₹66,080
10 Mar 2025
29 Jan 2025
11 Feb 2025
29 Jan 2025
10 Feb 2025
29 Jan 2025
Amount
Replacement of Following Spare Parts of Existing 10 HP VRV Units of Hitachi Make Installed in Albert Hall
Main Printed Circuit Board Assembly
Noise Filter Assembly
Fan Protection Assembly
Fuse Assembly
Voltage Protection Assembly
Power Terminal
Wired Remote Controller
Compressor for 10 HP ODU
Replacement of Following Spare Parts of Existing Indoor Units of Hitachi Make Installed in Albert Hall
Fan Motor for Floor Standing Unit
Fan Motor Gromit for Floor Standing Unit
Printed Circuit Board Assembly for Ducted type Unit
Dismantling & Installation of Compressor for 10 HP VRF system including Nitrogen test flushing, vacuumizing, gas charging & re- commissioning etc. as required.
Leakage rectification work for 10 HP VRF system including N2 testing, flushing, vacuuming, Gas Charging & Re- commissioning etc. as required.
ReInstallation for VRF system including N2 testing, flushing, vacuuming, Gas Charging & Re- commissioning etc. as required.
SITC of Copper Piping for VRF System including 19/13 MM nitrile insulation along with All necessary supports & Fitting Etc.- 28.6 mm - 12.7 mm) - (Make- Maxflow)
SITC of Transmission Wiring between Indoor & Outdoor units for VRF System including 20mm PVC Conduiting with All necessary supports & fitting etc.- 1.0-1.5 Sq. MM X 2 Core (Make- Polycab)
Wet Servicing of Indoor Units with Jet washer Pump
Wet Servicing of Outdoor Units with Jet washer Pump
Replacement of 1.5 TR Split AC Indoor Unit
Comprehensive Annual Maintenance of Existing centralized HV Air conditioning system , AHU, Air Curtains, etc. Installed at Central Museum Albert Hall as per Special Terms & Conditions of Tender Document.
Comprehensive Annual Maintenance of Existing centralized HV Air conditioning system ( Daikin Make , A 14 HP VRV model) at Interpretation centre of Jantar Mantar , as per Special Terms & Conditions of Tender Document.
Replacement of Following Spare part 1. PCB, Contactor, Fan Motor, Copper Piping etc. of Existing Cassette type Split AC of Sisodiya rani ka Bagh
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .